Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹135.21Accepted-AOC PLOT NO 927 SECTOR 47 GURGAON 2022R6406 | GURGAON | ₹135.21 Quoted ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹60,946 (0.45%)Rejected-Finance DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | ₹1.4 Cr+₹60,946 (0.45%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.4 Cr+₹1.5 L (1.10%)Rejected-Finance TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | ₹1.4 Cr+₹1.5 L (1.10%) | L3 | Rejected-Finance L3 |
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
8 Nov 2024, 5:30 pmClosed
NAVIN KUMAR
ED - Gurgaon
Construction of new judicial courts complex Gurugram (Providing Audio System for block having G plus 6 floors)
2024_HRY_408281_1
2024E13BAC67 3D4A 4DFA B0C5 4954C1DFD7C8664BAR
Open Tender
Electrical Works
Works
240 days
Gurugram
2 documents required · 2 mandatory
₹15,000
₹2.5 L
Yes
24 Jan 2025
30 Oct 2024
11 Nov 2024
30 Oct 2024
8 Nov 2024
30 Oct 2024
30 Oct 2024 - 31 Oct 2024
Amount
Normal court room Supply, Installation, Tetsing & Commissoning of gooseneck microphone with hypercardioid / super cardioid/Unidirectional, lobar polar patetrn, Frequency response : 50Hz-18KHz , Impedance : 50 Ω or better, ON/OFF button with lighting indication etc complete required as per specification omplete in all respect upto the entire satisfaction of Engineer in charge of the work. Make Heinrich/Shure/Televic
Supply, Installation, testing and commissioning of 6.5 + 1.5" two-way coaxial thin edge ceiling loudspeaker, 100V transformer power taps : 40 - 30 watts, Conical dispersion : 142° or more, impedance : 8, low impedance RMS continous power : 40 Watts, frequency range : 70 Hz 90Hz- 20 kHz, frequency response : 100 - 20KHz, SPL 1W/1M : 90dB, Max. SPL 105dB etc complete required as per specifications complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make Heinrich/Shure/Televic
Supply, Installation, testing and commissioning of digital power amplifier, 4 X 120watt @ 100V & 8 ohm , Technology : Class-D, Protection : DC short circuit; Over load; over heating; signal limiting; temperature controlled fan, switching mode power supply, THD+N : < 0.2%, Frequency raesponse : 20Hz-20KHz etc complete required as per specifications. complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make : Heinrich/Shure/Televic
Supply Installation Testing and Commissioning of digital signal processor with minimum 6-channel Phantom Power Or more Mic / line input and 6- channel circuit Output or more line output, 1no. Or more USB input, 6no. Or more GPIO input, above and enable to make all required presets and control all the connectivity etc, Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD <0.003%, Channel Seperation >92dB,Seperate Mute Control each channel,CMRR>80dB, 6 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC,High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable.Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing. complete required as per specifications complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make Heinrich/Shure/Televic
Supply Installation Testing & Commissioning of 2c x 1.5 sqmm shielded Speaker Cable complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make : Polycab/RR/Finolex
SITC of shielded microphone cable complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make polycab/finolex/Henrich
SITC of 6 U rack having Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking,Welded Side Walls,1U Cable Manager (1), Hardware Packet (1 Pkt),6 Socket 5 Amp. Power Distribution Unit (1 No) Roof Mounted Fan Unit / 90 CFM /230V AC (1 No).Rack should be as per DIN41494 Standards.OEM must be ISO 9001,14001 certified complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work. Make:- Rittal/ D-Link/Hive Network/Comrack
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. (As per HSR item no. 23.7.6.2) PVC pipe of 25 mm dia.
Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work.(As per HSR item no. 23.23.6.1) MS perforated cable tray painted with powder coating 100 X 50 X 2 mm3
Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in charge of the work. (As per HSR item no. 23.23.7.1) GI cable tray cover suitable for cable tray of 100*50*2 mm
Supply and erection of PVC round sheathed multicore annealed bare copper conductor cable 1100 volts grade in pipe of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work 1.5 sq.mm 3 core copper wire
INDIAN SECURITY AND FIRE SAFETY (BID ID -1164508)
Prime Computers (BID ID -1164606)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .