| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.3 L+₹44,948 (2.39%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹20.0 L+₹1.2 L (6.22%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹22.5 L+₹3.7 L (19.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹22.7 L+₹3.9 L (20.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
19 Jan 2022, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPECIAL REPAIR TO BLDG NO T-16, T-61 AND T-62 (M ZONE) IN FD HOSP AT POONCH UNDER GE 881 EWS
2021_MES_497094_1
GE/PNH-60/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹52,000
Yes
16 Mar 2022
23 Dec 2021
21 Jan 2022
23 Dec 2021
19 Jan 2022
6 Jan 2022
Amount
B&R PORTION:- Demolition of cement concrete (unreinforced) as in ground floor and pavings n.exc 15cm thickness below or above ground level complete all as specified and directed.
M&L For PCC 1:4:8, type D-2 using 40mm graded crushed aggregates as in floor surface complete all as specified and directed.
M & L for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for Reinforced cement concrete(nominal mix) 1:2:4 type B1 using 20mm graded crushed stone aggregate as Beams, cantilevers, bressummers, lintels over 1.5m span in slabs, complete all as specified and directed.
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, with Fair finished surfaces, complete all as specified and directed.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) ot less than 0.9mm dia or securing with clips, complete all as specified and directed.
All as per item No 07 above but 8mm to 10mm dia bars as in stirrups, spacers and binders complete all as specified and directed.
S&F glazed colored digital ceramic colored/printed digital tiles size 300x200x6 to 7 mm thick as in vertical surfaces such as skirting, dados & repairs to step, including rendering 10mm thick in CM 1:4 as Backing coat etc complete all as specified and directed.
M&L for non skid ceramic coloured tiles of size 400x400x7mm thick in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including cement screed bed 15 mm thick in cement mortar 1:4 base complete all as specified and directed.
M&L for glazed digital ceramic coloured tiles of size 450 mm x 350 mm x 7mm/ 350x 250x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Note:- Shade/Colour of tile shall be approved by the GE.
M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not less than 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match (light shade) including Screed bed or bedding layer of mortar 15 mm thick CM 1:4 for laying floor/wall finishes complete all as specified and directed.
M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not less than 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match (light shade) including rendering of mortar 10 mm thick CM 1:4 for laying floor/wall finishes complete all as specified and directed.
Taking down cement plaster on wall of any desription incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1: 6 on other than fair faces of brick work or stone masonary surfaces, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Rendering 20 mm thick in cement mortar 1: 4 on other than fair faces of brick work or stone masonary surfaces, chajja and suspended work finished even and smooth without using extra cement using WPC @ 3% of cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately
Supply only Water proofing compound complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
M&L for Preparation of new plastered or un-plastered surfaces of walls and applying two coats of OBD on walls complete all as specified and directed.
M&L for Preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint on walls complete all as specified and directed.
Taking down chowkat or frame n.exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkat or frame exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description exc 2 sq. m each complete all as specified and directed.
S&F 35mm thick 2nd class hardwood, Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S&F for 35 mm thick 2nd Class Hard Wood gauged and skeleton shutters, open rebated and prepared to receive gauge etc (with sash bars), edges of raming plain, chamfered or grounded, fitted with cut of and mitred beads for securing gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and directed.
S&F 2nd class hard wood, 30 mm thick, glazed and skeleton shutter, divided into square, with plain, chamfered or rounded mitered and rebated sash bars, any number of panels, prepared to receive glass, gauge etc. edges of frames chamfered or rounded, fitted with cut and mitered beads for securing glass etc. size of members as specified in SSR Part I clause 8.24 (b) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and directed.
S&F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for Reinforced cement concrete Type B1 1:2:4 ( Nominal mix) (using 20mm graded crushed stone aggaregate) as in slab etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F Rotational moulded PVC water tanks of 500 Ltrs capacity, cylindrical vertical with closed top hoisted and fixed in position including dismantling existing tank and removing from site complete all as specified and directed.
S&F in repair 20mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified and directed.
S&F in repairs Stop cock/Gate Valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified and directed.
S&F in repair Bib tap 15 mm bore, Brass CP, fancy type (long shank). with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F GI tubing medium grade 15mm bore pipe and including all accessories complete all as specified and directed.
M&L for Chequred cement concrete tiles, 30cmx30cmx25cm thick, with white cement and pigment, set jointed and pointed in near cement slurry in floors complete all as specified and directed.
S&F 100mm butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 75mm butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 150mm long aluminium anodised tower bolts complete all as specified and directed.
S&F 150mm size aluminium anodised door handles complete all as specified and directed.
S&F 300mm long alluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded section and fixing bolts and sliding of extruded section complete all as specified and directed.
S&F for 300 mm, mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for Two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces over 10 cm in width or girth including preparation of new or previously untreated surfaces of wood complete all as specified and directed.
S&F for 2nd class soft wood (kail) as in scantling clean sawn and fitted in unframed works complete all as specified and directed.
Dimantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F in position suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 3mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips complete all as specified and directed. Make:- Everest Industries Ltd or make as specified in PS.
M&L for 25mm thick PCC (1:2:4) type B-0 with using 12.50 mm graded stone aggregates as in sub base of flooring, finished even and rough to receive the top layers complete all as specified and directed.
S&F 10mm thick toughened glass in door with both side rotating floor spring, stainless steel hinges, 300mm long stainless steel handle, rubber strip all around incl all necessary fitting required for fixing the door complete all as specified and directed.
S&F 10mm thick toughened glass in fixed window with aluminium frame all around incl all necessary fitting required for fixing the window complete all as specified and directed.
M&L for cement concrete 1:2:4 Type B-0 12.5mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:5:10, type E2 (using 40mm graded agg) as in surfaces of concrete in sub-floors, sub-base complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings, guard bar etc with ends of bars shouldered or riveted or for forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290. Gde -E- 165 complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 18-20 mm thick over cement screed bed laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including and polishing complete over 20 mm screed in cement mortar 1:4 complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge, thickness, including Nainital or similar pattern roof coverings including ridges complete all as specified and directed.
S & F 0.63 mm thick, Galvanized, corrugated mild steel sheeting with two corrugations side lap, fixed with L type or J type or cranked hook bolts, in roofs, covering wall etc with grade of zinc coating and bent to curved of any radius complete all as specified and directed.
All as per item No 58 above but except sheets complete all as specified and directed.
S & F 0.80 mm thick, plain galvanized,mild steel sheeting in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed) with L type or J type or cranked hook bolts, in roofs, covering wall etc with grade of zinc coating and bent to curved of any radius complete all as specified and directed.
M & L for preparation of new steel surfaces applying two coats of synthetic enamel paint over 10 cms width or girth over a coat of red oxide primer etc. complete all as specified and directed.
M & L for preparation of old painted steel surfaces removing of paints by blower lamp & applying one coats of synthetic enamel paint over 10 cms width or girth complete all as specified and directed.
M&L for one coat of OBD on old treated plastered surfaces including preparation of wall complete all as specified and directed.
M&L for one coats of cement base paint on old surfaces including preparation on Walls complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from matel frame including punching or drilling out old glazing pins/spribng clips and providing and fixing new onces exc 1.5 Sqm complete all as specified and directed.
Dismantling mild steel work as in wind tie grill gratings as it is complete all as specified and dircted
Fixing only hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters bars, for doors, balusters, nosing tosteps including embeding in concrete and screwing etc. wind ties for roof including security bolts, posts and struts in fencing lincluding cutting tops to shape as dircted, drilling holes, notching for wire, etc. Flat iron fillets (for security wire mesh etc) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling timber scantling 40 Squcm and over in section in any position as in unframed work, complere all as specified and directed.
M&L Rolled mild steel works as in roof trusses, purlin (Beam, Channel, Angle) complete all as specified and directed.
M&L walling of random rubble, brought upto course well bonded bedded, and solidly hearted, built in CM 1:6 complete all as specified and directed.
All as per item No 70 above but except stone complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc for one light/ bell point controlled by one way switch 6 Amp complete all as specified and as directed.
All as per item No 74 above but one fan point (Ceiling and exhaust) controlled by one way switch 6 Amp complete all as specified and directed.
All as per item No 74 above but one 5 pin, 6 Amp socket outlet on the same board complete all as specified and directed.
All as per item No 74 above but one 5 pin, 6 Amp socket outlet on the independent board complete all as specified and directed.
All as per srl item No 74 above but for one 3 pin socket outlet 15 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair Ceiling rose, 3 phase PVC/poly carbonate, insulated body, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge. Make:-Havells/Anchor/Legrand
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Tube light fitting box type suitable for LED 20W tube rod made out of ultra bright, glass shell, glare free, wide angle, single side connection retofit LED tube with G13 lamp holders complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting including 20LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LHFXCEP1TNNW020 for batten fittings or Equivalent cat part of make as specified in PS. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair LED building security light fittings 35W made up of pressure die cast aluminium housing LED Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Deviceas lighting source seperate driver compartment with IP66 protection complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:- ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or Equivalent cat part of Make specified in PS
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 16 sqmm including taking down complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed.
Removal of excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M&L for Approved quality clean dry sharp sand as in cushioning to under ground cable laying 15cm thick before laying and 8cm after laying the cable in trenches for cable cushioning, complete all as specified and directed.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Supply and laying GI tubes light grade ISI marked , galvanized, 40mm bore laid in trenches or under floor or fixed with poles/ walls for protection of electric cable including taking down complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 2.5 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 2.5 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 2.5 sqmm, 1 wire of 2.5 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
S&F in repair LED lamp CDL 10 watt with holder base (B22) type, complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDEUEEML8R010 or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 20 Amps MCB SP complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 4 sqmm, 1 wire of 4 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
SUNIL KUMAR SANGEET KUMAR AND SONS
M/S BADRI NATH GUPTA
Modh Hafiz Khan
M/S FAIZ AHMED KHAN
BALVINDER SINGH AND SONS
M/S BONA CONSTRUCTION
JAMWAL CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .