Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83,160Accepted-Finance | ₹83,160 | L1 | Accepted-Finance 1st Lowest Bidder |
| 2 | L2₹84,700Rejected-Finance | ₹84,700 | L2 | Rejected-Finance 2nd Lowest Bidder |
| 3 | L3₹1.2 LRejected-Finance DHARAM KHOR BABU BHATNI BHATARPUR RANI DEORIA U P 274705 | DEORIA | DEORIA | UTTAR PRADESH | 274705 | ₹1.2 L | L3 | Rejected-Finance 3rd Lowest Bidder |
| Sl No | Description | Qty | Unit | R.T.K POWER ENGINEERS L3 | K. D AND GUPTA ELECT. AND ENGG. WORKS L1 | M/s Radha Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.00 | Complete rewinding of 0.5 KW, 3-ɸ, 415 V, 0.9 Amp cooling fan motors of 160 MVA Power transformers. The work covers lowering of fan from radiator bank, complete dismantalling of all parts of fan motors, its rewinding by super enamel copper wire of same specification & gauge, varnishing of complete motor body, replacement of damaged front and rear side bearing with new ones of same size and standard make, oiling & greasing of all moving parts, reassembling of motor & testing for normal running of cooling fan with all cost of men, material, carriage and T&P required for the job. | 8 | Nos. | 8,500 ₹68,000 | 4,455 ₹35,640 Lowest | 4,500 ₹36,000 |
| 2.00 | Complete rewinding of 0.24 KW , 3-ɸ, 415 V, 0.6 Amp cooling fan motors of 20 MVA Power transformer. The work covers lowering of fan from radiator bank, complete dismantalling of all parts of fan motors, its rewinding by super enamel copper wire of same specification & guage, varnishing of complete motor body, replacement of damaged front and rear side bearing with new ones of same size and standard make, oiling & greasing of all moving parts, reassembling of motor & testing for normal running of cooling fan with all cost of men, material, carriage and T&P required for the job. | 4 | Nos. | 4,500 ₹18,000 | 2,970 ₹11,880 Lowest | 3,100 ₹12,400 |
| 3.00 | Repairing, rectification and Rewiring of local marshalling box of 160 MVA Power Transformer's cooling fan control circuit, the work including replacement/ repair of damaged connectors, MCCB , MCBs, ON/OFF selector switch , Group Selector switch, Contactors, push button, fuse base, Terminal Blocks, Thermal over load relay, starter in the marshaling box and all other associated works. (All consumable materials shall be provided by Contractor) | 3 | Job | 10,000 ₹30,000 Lowest | 11,880 ₹35,640 | 12,100 ₹36,300 |
Tender Value
Refer Docs
EMD Value
₹1,000
Closing Date
23 Jun 2026, 5:00 pmClosed
Executive Engineer
Office of Executive Engineer Electricity 400 KV Sub Station Division Motiram Adda, Gorakhpur.
Estimate for the work of Rewinding and Servicing of Cooling fans and replacement of defective contactors, relay, MCBs etc. in the M.Box of 220/132kV, 160MVA T/Fs and 132/33kV 20 MVA T/F at 220 KV S/S Motiram Adda, GKP, under Electy. 400 KV S/s GKP
2026_UPTCL_1152442_1
E-TENDER No. 01/400KV/SSD/GKP/2026-27
Open Tender
Electrical Works
Item Rate
60 days
E 400 kV S/S Motiram Adda
Please Refer Tender Documents
2 documents required · 2 mandatory
₹590
Yes
EE E400 S/S Division Motiram Adda, Gorakhpur
₹1,000
Yes
29 Jun 2026
23 May 2026
24 Jun 2026
23 May 2026
23 Jun 2026
23 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Complete rewinding of 0.5 KW, 3-ɸ, 415 V, 0.9 Amp cooling fan motors of 160 MVA Power transformers. The work covers lowering of fan from radiator bank, complete dismantalling of all parts of fan motors, its rewinding by super enamel copper wire of same specification & gauge, varnishing of complete motor body, replacement of damaged front and rear side bearing with new ones of same size and standard make, oiling & greasing of all moving parts, reassembling of motor & testing for normal running of cooling fan with all cost of men, material, carriage and T&P required for the job. | 8 | Nos. | - | - |
| 2 | Complete rewinding of 0.24 KW , 3-ɸ, 415 V, 0.6 Amp cooling fan motors of 20 MVA Power transformer. The work covers lowering of fan from radiator bank, complete dismantalling of all parts of fan motors, its rewinding by super enamel copper wire of same specification & guage, varnishing of complete motor body, replacement of damaged front and rear side bearing with new ones of same size and standard make, oiling & greasing of all moving parts, reassembling of motor & testing for normal running of cooling fan with all cost of men, material, carriage and T&P required for the job. | 4 | Nos. | - | - |
| 3 | Repairing, rectification and Rewiring of local marshalling box of 160 MVA Power Transformer's cooling fan control circuit, the work including replacement/ repair of damaged connectors, MCCB , MCBs, ON/OFF selector switch , Group Selector switch, Contactors, push button, fuse base, Terminal Blocks, Thermal over load relay, starter in the marshaling box and all other associated works. (All consumable materials shall be provided by Contractor) | 3 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
TECHNICAL_01.pdf
Tender Documents • 1.09 MB
BOQ_2158870.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].