Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | -37.44% | ₹4.6 L | L1 | Admitted-Finance |
| 2 | L2₹4.7 LAdmitted-Finance NONE | -36.40% | ₹4.7 L | L2 | Admitted-Finance |
| 3 | L3₹5.6 LAdmitted-Finance 205 0 8 110092 | SHAHDARA | DELHI | 110092 | -24.00% | ₹5.6 L | L3 | Admitted-Finance |
Tender Value
₹7.3 L
EMD Value
₹14,641
Closing Date
5 Mar 2026, 3:00 pmClosed
EE(E)
North Electrical Division, PWD, Dr. BSA Hospital, Sector -6, Rohini, Delhi - 110085
Supply Installation Testing Commissioning of water cooler with inbuilt ROs LED fittings street lights and Flood Lights in Asha Deep Home Delhi
2026_PWD_287890_1
112/NED/PWD/M-352/2025-26
Open Tender
Electrical Works
30 days
as per nit
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹14,641
Yes
9 Mar 2026
27 Feb 2026
5 Mar 2026
27 Feb 2026
5 Mar 2026
27 Feb 2026
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm
b) 3 x 4 sq. mm
c) 6 x 4 sq. mm
d) 3 x 6 sq. mm
e) 6 x 6 sq. mm
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 40 watt
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 90 watt
Supply of one number PVC insulated and PVC sheathed / XLPE with Al. conductor armoured power cable of 1.1 kV grade of following size complete as required. a) 4x16 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Provision for pole / wall mounted box (300x200x105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required. a) 32 Amp 5 Way connector with bakelite base. b) 6 Amp SP MCB 'C' Curve (10 KA) - 1 No. c) Earth Studs - 2 Sets. d) 40 x 5 mm clamp with 2 Nos. 3/8" Nut & Bolts - 1 Set as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying & fixing suitable size GI box with modular late and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C
Supply, Installation, Testing and Commissioning of heavy duty exhaust fan of 380 mm sweep 1400 rpm in the existing opening, i/c connection testing commisioning with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd
Making hole for installation of exhaust fan of size upto 450mm sweep by demolishing brick work manually/by mechanical means including disposal of malba within 50 meters lead and making good the wall by plastering etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 12 way , Double door
Provision for pole / wall mounted box (400 x 300 x 190) mm size made out of (SMC) sheet moulding compound dust & wheather proof with front openable hinged type cover with locking arrangement i/c providing and fixing of following accessories mounted on 6 mm thick bakelite sheet i/c connection with suitable size of copper wire and fixing the box on the existing pole / wall with suitable size/capacity 4 strip (3 phase + neutral) busbar arrangement as required: a) 63A 4 pole MCB - 1 No. b) 40 A 4 pole MCB - 2 Nos. c) Digital Timer - 1 No. d) 3 pole 50A MNX Contactor-1 No. e) Auto manual Switch- 1 No. f) SPMCB -1 No. Note:- The cables glands shall be interconnected with suitable size metalic strip having suitable size stud for termination of earth wire, all bus bar must be cover with suitable insulation materials, no current carrying conductor should be open.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Al. conductor armoured/unarmoured power cable assorted size
SMC Box, GI Box
Assorted size SP, SPN MCB
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_381656.pdf
techsummary_381656.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_381656.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid