Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1ST₹13.3 LAccepted-Finance SARBERIA NARAYANDARI PURBA MEDINIPUR 721655 | NARAYANDARI | PURBA MEDINIPUR | WEST BENGAL | 721655 | 1ST | Accepted-Finance 1st lowest bidder | |
| 2 | 2nd₹13.3 L+₹2,436 (0.18%)Rejected-Finance SARBERIA NARAYANANDARI BHAGWANPUR PURBA MEDINIPUR 721655 | NARAYANANDARI | PURBA MEDINIPUR | WEST BENGAL | 721655 | 2nd | Rejected-Finance 2nd lowest bidder | |
| 3 | 3rd₹13.3 L+₹3,086 (0.23%)Rejected-Finance CHATAPADMAPUR BATTALA RAMNAGAR CONTAI DIST PURBA MEDINIPUR PIN 721 433 WEST BENGAL | CONTAI | PURBA MEDINIPUR | WEST BENGAL | 721433 | 3rd | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹26,590
Closing Date
24 Sept 2024, 1:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER, PWD ,SOUTH-WEST ERN ELECT
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Electrical Installation work for construction of rest room of doctors,Nurses, Gr.D in Different places and installation of Compound light and pole at Contai SD Hospital, Nandigram HD
2024_WBPWD_752175_1
WBPWD/SE/SWEC/NIQ33/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Purba Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹26,590
5 Oct 2024
17 Sept 2024
26 Sept 2024
17 Sept 2024
24 Sept 2024
17 Sept 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. Avg Run 9 Mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Board
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x 100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite /perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as require.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand -Myrius/North west), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ for Split AC m/c]
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand -myrius/North west) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch boardand cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ for Split AC m/c]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand -myrius/North west) & necy.Connections.
Supplying and fixing 230V 6/10A, 2+8 way SPN MCBDB (Make: Legrand) comprising of 1no. 40A DP Isolator & 8nos. 6/10A SPMCB double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Supplying and fixing 415V 6/10A, 4 way TPN MCBDB (Legrand make) comprising with of 1no. 63A FP Isolator and 12 nos.,(6- 32)A SP MCB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS ( Make - Legrand ) 8 Way ( Up to 160 A )
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. 160A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 63A TP [ 7 / D- 6]
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991
S & D of Single LED Tube light fitting [Make - Philips cat no. TMC 502 1 x T-LED / Crompton cat no. IGP161 LT8-16] making connection as to GS
S & D of Twin LED Tube light fitting [Make - Philips cat no. TMC 502 2x T-LED/Crompton cat no. IGP162 LT8-1] making connection as to GS
S& D of 215V, 18/20 W, 4 feet long Single LED Tube light [Make - Philips Master LED tube model no.18W 865 T8 I 2100lm ]
Fixing only single/twin fluorescent light fitting in the ceiling fixed with “L” type MS clamp as per GS [17/C-2]
Extra for suspension exceeding 25cm with s & f additional 2 no. 20mm dia conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as reqd. by 2 x 24/ 0.20 mm (1.5 sqmm) flexible copper wire of 1.10mt. Length [C-2/16]
Supply & delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent make of Crompton Greaves and as per direction of EIC as per direction of EIC.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[C-3/21(a)]
S&F 240V, 100W rotary step type electronic fan regulator on board with making necy. Connection .(make Anchor)[E-6/18(a)]
Supply and delivery of 230V 300 mm (12") Speed 1420 RPM Heavy Duty Exhaust fan with all necessary accessories [Make: EPC/Usha/ CG or equivalent Make]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:(a) 23 cm (9") [C-4/28 (a)]
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 23 cm Exhaust fan (9") [D-14/32 (a)]
Supply & fixinng 240 V, interval timer for exhaust fan consistung ON/OFF toggle switch, indicator, 4 way connector & 2 hrs ON & 30 minits off condition fixed in 7 '' x 4'' PVC board including s & f pvc board as per direction of EIC. (Elektra)
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.[D-13/22]
Supply and Fixing 9W LED bulb ( make- Philips/Crompton/Orient electric)
Supply and Delivery of Timer DB :- 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch(Make- L&T-AUTS03ANA00/Legrand/ABB) 2) 2 Pole Power Contrcator (L&T-MNX 22-2P Cat No-CS90238/Legrand/ABB), 3) 20A SP MCB. (Legrand/ABB/Siemens) 4) 32A DP Isolator. (Legrand/ABB/Siemens) 5) Toggle Switch. (Make- L&T or equivalent make) 5) (2+12 Way) SPNDB (Legrand/ABB/Siemens) Suitable Size Copper Stranded Wire. 6) LED INdication Lamp--- 02 Nos. 7) Push Button --- 01 Nos 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / ABB ) (For Single Air Conditioner Machine )
Distn. Wiring in 1.1 Kv gr. Single core stranded ‘FR’ PVC insulated & unsheathed cu. wire (Havells / RR Kable / Polycab) in 20/32/40 mm size PVC rigid conduit ‘FR (precession) incl. necy. Fitting as reqd.
a) 2 x1.5 sqmm + 1x 1.5sqmm for ECC
b) 2 x2.5 sqmm + 1x 1.5sqmm for ECC
c) 2 x 4 sqmm + 1 x 2.5 sqmm for ECC
d) 2 x 6 sqmm + 1 x 4sqmm for ECC
e) 4 x10 sqmm + 2 x 6 sqmm for ECC
Finishing end of copper wire and PVC/Al cable of the following sizes by crimping method as per GS
Supply and fixing compression type gland complete with brass gland brass ring and rubber ring for dust and moisture proof entry of XLPE/PVC armoured cable. For 4 core 70 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials. For 4 core 70 Sq.mm
S & F of outdoor luminaire ( IP 66 ) with pressure die cast housing with toughened glass and high power LEDs with secondary optics , 10KV SPD, THD < 10%, PF> 0.95, BIS approved, minimum LPW: 110 lumen/ Watt, 230Volt, 50Hz. [Make: Philips:- BRP033 LED100 CW SLR GR PSU SPD/ Crompton/Wipro]. [Warranty period for this item: Minimum 05 (five) years.]
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe(ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting &making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire andmaking connections as required and mending good damages to wall and painting.[C-3/19]
Supply and Fixing SMC Junction Boxes of dimention (250x200x105)mm with IP 67 protection (Sintex / Hensel )make for compound light. With 4 pole terminal stud and 6A 10KA C curve SP MCB Legrand make.
Supplying and delivery of 1.1 KV grade 2 core 4 sqmm armoured Alminium XLPE cable (Make: Gloster/Havells/RR Kable/Polycab)
Laying 2 core 4 sqmm on Wall / surface with Saddles / clamps.Laying of following cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.[F-1/2(a)]
Laying of one No. cable upto 2core 4sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.[F-2/1(a)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 core 4 sqmm[F-4/7(a)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :2 core 4 sqmm[F-5/8b(i)]
Inter connection of compound light fittings by 3 x 1.5 Sq. mm. PVC insulated copper wire (RR Kable /Polycab /Havells)from loop box & bracket with Pricision MMS PVC pipes as per direction of EIC[E-14/1a(i)]
Supply & delivery of hot dip galvanized (As per IS: 2629/IS 2633/IS 4759 & with its latest amendment) 8 mtrs length decorative octagonal pole made of HT steel( Sheet thickness- 3 mm) conforming to grade S355JO/JR of BSEN 10025 along with a welded base plate of required size stud of termination of 4 core 10/16/25/35 sq. mm al (Ar) cable incl S&F 1 no 6 amp SP MCB (c-series) with 4 way stud for each outgoing circuit to the fittings with proper pad locking arrangement for the pole. [Top dia (A/F)-70 mm Bottom dia (A/F)- 155 mm] Base plate size: 260 mm (L)x 260 mm(W) x 16 mm(Thickness). Foundation Bolt- 4-M24 x 750 mm(L) x 4 nos 'J' type bolts. (Make-Transrail / Valmont/Lysaght/Bajaj) (T.C & G.C must be submitted to EIC before execution) N.B: Specification of poles may be changed as per manufacturer standard, the agency must approve the material from the EIC before execution and should visit the site physically.
Erection of the following decorative octagonal pole by designing & casting RCC(M-16)foundation of suitable size as specified below considering the safe soil bearing capacity at the site as 10 T/sq m incl excavation of earth providing cutting bending and placing in position reinforcement as per drawing & providing pipe for cable entry & exit as per required & providing and fixing of 4 nos foundation bolt (J type) as specification below & as per drawing on ground surface incl backfilling cleaning extra earth---up to 9 meters. [Foundation size-500mm(L)x500mm(W)x1200mm(H), J Bolt size-M24 x 750mm [L].
S&F 50 mm. dia 1.5 Mtr. long detachable type Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (Make-Transrail / Valmont/Lysaght/Bajaj)
Supply & fixing 50mm dia medium gauge 1.5mtr long detachble type GI double arm bracket arm bracket shall be properly welded with 15 mm thick stiffner plate of pole sleeve for strengthening incl.proper fixing arrangement with the pole by bolt,nuts and washers as per direction of EIC. (Make-Transrail / Valmont/Lysaght/Bajaj)
Supply & Fixing of Weatherproof enclosure Conform to EN 60439-3, IP 65 - IK 09 with necessary clamping arrangement for fixing on the pole comprising and the enclosure size should be as that the all below installations items are properly accommodated and can maintenance properly : (i) 230 V, 50 Hz, Astronomical time switch. (Make - L&T- AUTS02AST00/Legrand/ABB ) – 01 Nos. (ii) Supply and Fixing of AC3- 12A , AC1- 30A 2 Pole Power Contactors 1 NO (Make- L&T- MNX 12-2P /ABB/SIEMENS)--- 01 Nos. (iii) Toggle Switch -01 No. (Reputed Brand) (iv) 240V, 16A DP MCB Isolator including necessary connection by required size Cu wire-- 01 Nos(L&T/LEGRAND/ABB/SIEMENS) (As a incomer) (v) 240V, 10 A SP MCB including necessary connection by required size Cu wire------- 01 Nos (L&T/LEGRAND/ABB/SEIMENS) ((As a Outgoing)
Supply of Single-Phase timer for controlling. Consisting of the following: a) (2+10) way SPN DB-1 No.-Double Door(Make: L&T/Legrand/ABB) b) 230 V, 50 Hz, Astronomical time switch. (Make - L&T- AUTS02AST00/Legrand/ABB ) – 01 Nos. c) Supply and Fixing of AC3- 22A, AC1- 32A ,2 Pole Power Contactors 1 NO (Make: L&T-MNX 22-2P )/ABB/SEIMENS) d) 240V, 32A DP MCB isolator including necessary connection by required size Cu wire-- 01 Nos (L&T/LEGRAND/ABB/SIEMENS) (As an incomer) e) 240V, (6-16A)SP MCB including necessary connection by required size Cu wire-- 01 Nos (L&T/LEGRAND/ABB/SIEMENS) (As an incomer) f) Push the Botton ON/OFF switch on the individual outer sides of the DB g) Toggle Switch--- 01 Nos h) Indication for ON/OFF by indicating LED Lamp--- 02 Nos i) The complete arrangement must be wired by 1.5/ 2.5/4 Sq.mm Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / ABB ) (For Compount light)
Supplying and fixing 32A,240V,DP Sheet steel Main Switches ( L&T/ Havells) on flat iron frame on wall.[D-1/1(a)]
Earthing with 50 mm dia GI pipe (ISI-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts below the ground level. [PWD /GS, Item no. 2( a), Page no. G-1]
Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cmx86.36cmx46cm deep (below ground level) complete with cemented brick work (1:6) of 25cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56cmx35.56cm with locking arrangement ,GI reducer including drilling of 46 nos. 12mm dia holes on the GI pipe.[G-2/3(a)]
Excavation of soil for insulation of earth electrode and filling & ramming for soft soil. [G-1/1(a)]
supplying & fixing earth bus bar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per G.S. [G-2/4(a)]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials as required 32 mm dia
Dismaintaling the all old VTPNDB,cables & all the old electrical equipments of and all material goes to section store inluding temporary arrangement as per EIC.
CHANDIMATA TRADERS (BID ID -5616457)
TAPAN ELECTRICS (BID ID -5595912)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .