Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.0 L+₹31,704 (4.76%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L2 | Rejected-AOC Rejected | |
| 3 | L3₹7.4 L+₹78,314 (11.8%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹8.0 L+₹1.3 L (19.5%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L4 | Rejected-AOC Rejected |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
26 May 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I TALBEHAT
AGE I TALBEHAT LAKE VIEW CAMP TALBEHAT PIN-284125
REPAIR/CLEANING OF SEWAGE LINE AND ITS CONNECTED WORKS IN ZONE A AT MIL STN TALBEHAT
2020_MES_341926_1
AGE(I)/TBT/TOK-06/2020-21
Open Tender
Civil Works
Item Rate
180 days
AGE I TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
₹16,000
Yes
9 Jul 2020
30 Apr 2020
30 May 2020
30 Apr 2020
26 May 2020
14 May 2020
90 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil etc. including trimming bottom and sides of trenches, levelling/ grading and ramming bottom of excavation complete all as specified and directed by Engineer-in-Charge
Demolition and breaking up 50-100 mm a dia (Salt glazed ware ,AC / CI or reinforced concrete)drain pipe, jointed set in cement mortar and taking out of trenches, floor, if required complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up 150 mm dia (Salt glazed ware ,AC / CI or reinforced concrete) set in cement mortar drain pipe, jointed set in cement mortar and taking out of trenches, floor, if required complete all as specified and directed by Engineer-in-Charge.
S&F 100mm dia Sand Cast iron soil waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F 100mm dia Sand Cast iron soil waste and vent pipes, in any length with or without ears, with cement joints and fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F 100mm dia Branch piece, single (equal or unequal) , ordinary or inverted, spigot or socket type or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia Sand Cast iron soil waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 100mm dia Cast iron bend diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia Cast iron bend diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge.
S&F 100mm dia Cast iron bend with oval access door diminishing pieces or tapers complete all as specified and directed by Engineer-in-Charge.
M&L for concrete bed for 100 mm bore pipe in PCC 1:3: 6type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed by Engineer-in-Charge.
M&L for concrete bed for 150 mm bore pipe in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed by Engineer-in-Charge.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance exc 250m but not exc 500m and depositing where directed complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone / boulder masonry , built in cement mortar incl all quoins , pillars etc complete all as specified and directed by Engineer-in-Charge.
M & L brick work with fly ash bricks straight or curved on plan exec 6 M mean radius with old size bricks in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc incl racking out joints, hacking for key, scrubbing down with water etc. Note: All debris obtained from taking shall be removed 1.5km to 2km complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm on fair faces of brick work finished even and smooth without using extra cement in CM (1:4) mixed with liquid water proofing compound @ 0.25% by the weight of cement or as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge. Note:- Liquid water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound.
Material and labour for PCC 1:4:8, type D2 using 40mm graded stone aggregate as in foundations, fillings, mass concreting complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC 1:2:4, type B1 using 20mm graded stone aggregate as in coping/channel benching of manhole, laid to shape and slope surfaces finished even and smooth using extra cement including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and directed by Engineer-in-Charge.
Providing precast cement concrete type B1 1:2:4 20 mm graded aggregate as in cover slabs for septic tank/ manholes/drains set in cement Mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L TMT bars 10 mm dia and over cut to length bend to shape required incl. cranking hooking ends and binding with and incl. MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
S & F MS round bar of 10mm dia and over as in rungs/handle for manhole cover conforming to Fe-410-W (Gde. E-250) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
M & L for 75 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) finishing concrete surface even and smooth using extra cement complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC waste pipe, 32 mm dia for WHB or sink complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC waste pipe for urinal complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CP grating 110mm dia complete all as specified and directed by Engineer-in-Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., and removal complete all as specified and directed by Engineer-in-Charge.
S & F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S & F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S & F for 110 mm bore PVC (SWR) bends of any radius including door system complete all as specified and directed by Engineer-in-Charge.
S & F for 75 mm bore PVC (SWR) bends of any radius including door system complete all as specified and directed by Engineer-in-Charge.
S & F for 110 mm bore PVC (SWR) shoe of any angle complete all as specified and directed by Engineer-in-Charge.
S & F for 75 mm bore PVC (SWR) shoe of any angle complete all as specified and directed by Engineer-in-Charge.
Demolition of existing gully trap chamber and construction of half brick work chamber of size 450 x300mm in CM 1:4 including plastering in CM 1:4, PCC coping (1:2:4) type B0 with RCC cover slab of required size including disposal of waste/ sludge complete all as specified and directed by Engineer-in-Charge.
Cleaning, dislodging and Pumping out of water / liquid / sludge or any other waste/materials stagnated in septic tank / soak wells through mechanical through hose pipe or by other means upto distance of exc 250 mtr and not exc 1.5KM depositing the same into a pit and covering with a excavated earth layers. Finally top position to be covered by a layer of each earth spreading bleaching powder @ 200 gms per Sqmt for disinfections purpose complete all as specified and directed by Engineer-in-Charge. Note- Excavation of pit is deemed to be included in this item.
Cleaning and removing of blockage of any type of sludge /effluent etc in sewage line any dia including affected manholes and disposal of waste materials / spoils upto a distance of 50 mtrs by any means manually with the help of green bamboo or any other mechanical method including washing out manhole and sewage line and disposal of waste / sludge in pits complete all as specified and directed by Engineer-in-Charge. Note:- Each time cleaning of blockage shall be paid and measured separately
Cutting into existing manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed by Engineer-in-Charge.
M & L for attending of sewage complaints for blockage of WHB, WC, Urinals, Sinks, bottle trap, floor trap, Nahani traps, WC gully trap, vertical CI pipe/PVC pipes of any dia including junction holes of any description in the AOR of AGE(I) Talbehat. with and including petty repairs items/materials i.e. screws, washers, plugs, grease etc, cutting of grass, vegetation, shrubs etc, digging out roots completely by crow bars, chisel etc, cleaning of sewer/rain water pipelines with manholes laid in any situation for cleaning and removing blockage from entire system and making it fully functional and removal of sludge / mud, complete all as specified and directed by Engineer-in-Charge. Note : Any major item/material which are required to be replaced shall be paid under respective item of this schedule. The cost of minor items like nails / screws / hexa blades / washers / plugs / grease etc shall be deemed to be inclusive in the quoted rates only. NOTE - All the complaint(s) will be addressed and rectified within 60 minutes from the time of receipt of complaint. If, contractor or his tradesmen fails to attend and rectify the complained within 02 hrs from the time of receipt of complaint, the compensation/penalty of Rs. 50.00 (Rupees Fifty only) per complaint per hr for first 02 hrs and after that Rs. 100.00 (Rupees One Hundred only) per complaint per hr shall be recovered from the contractor’s dues. Note:- Each time cleaning of blockage shall be paid and measured separately.
HARNAM SINGH ANIL SINGH
M/s Indu Enterprises
M/S Kharya Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .