Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.6 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹72.1 L+₹1.3 L (1.79%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹72.5 L+₹1.7 L (2.38%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹73.0 L+₹2.2 L (3.04%)Rejected-Finance 203 NIVAAN LAXMI SOCIETY PLOT NO 169 SECTOR 19 KHARGAHAR NAVI MUMBAI 410210 | RAIGAD | MAHARASHTRA | 410210 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹74.6 L+₹3.7 L (5.25%)Rejected-Finance 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | M.K Enterprises | M.K Enterprises L3 | Mahadev Enterprises L5 | Shri Krishna Trading Corporation L2 | Sagar Electricals L6 | BALAJI TRADERS L4 | DIGITAL SERVICES L7 | OM ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Notes:- 1. Supplying & erecting steel scaffolding upto required height with top platform with support railing at top etc. The Scaffolding should be secured properly in position, complete as per site requirement & directions of Engineer-in-Charge.
2. Supply & fixing of dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair works in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system at shown area before start of work, removal after completion of work, carrying out regular cleaning etc. complete as per site requirement & directions of Engineer-in-Charge.
3. Supporting the structural components temporarily during repair and strengthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonally at centre with each other using suitable heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration, complete all as specified and directed by Engr-in-charge.
4. Structural rehabilitation work shall be got executed through one of the specialist firm(s) listed below as approved by GE prior to commencement of work :-
(a) Rebuild Technologies Services Pvt Ltd 602, 6th Floor, Tulsee Chamber, Teen Petrol Pump, Thane (W) E
(b) Techton Buildcons Pvt Ltd 203, Plot No 6, Millenium Plaza, Sakinaka Telephone Exchange Lane, Off AK Road Andheri E-Mumbai 72
(c) Sanrachana Structural Strengthening Pvt Ltd 103, 104, Monalisa CHS, Hariniwas Circle, Thane West - 400602
(d) USHTA Infinity Construction Co Pvt Ltd Ushta House, C-17/79 Krishna Industrial Estate, Gorwa, Vadodara - 390016 India
(e) Gubbi Civil Engineers 18/26 Dev Prayag CHS, Opp Thanawala garage, Bhakti Mandir Road, Near Hari Nivas Circle Thane (W), Thane, Maharashtra 400602 | - | - | - | - | - | - | - | - | - | - |
| 2.00 | Removing, chipping and cleaning of existing loose and damaged concrete carefully upto 60mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete including cleaning the surface by air jet and stacking & disposal of unserviceable materials outside the premises, etc. complete all as specified and as directed by Engr-in-charge. | - | - | - | - | - | - | - | - | - | - |
| 2.01 | (a) Upto 4th floor | 350 | Sqm | 69 ₹24,150 | 69 ₹24,150 | 70 ₹24,500 | 75 ₹26,250 | 250 ₹87,500 | 210 ₹73,500 | 56 ₹19,600 | 50 ₹17,500 Lowest |
| 2.02 | (b) 5th floor to 8th floor | 125 | Sqm | 79 ₹9,875 | 79 ₹9,875 | 72 ₹9,000 Lowest | 75 ₹9,375 | 200 ₹25,000 | 240 ₹30,000 | 72 ₹9,000 Lowest | 75 ₹9,375 |
| 2.03 | (c) above 8th floor | 50 | Sqm | 99 ₹4,950 | 99 ₹4,950 | 76 ₹3,800 | 75 ₹3,750 Lowest | 180 ₹9,000 | 235 ₹11,750 | 96 ₹4,800 | 100 ₹5,000 |
| 3.00 | Providing and applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/litre and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation works, etc. complete all as specified and as directed by Engr-in-charge. | - | - | - | - | - | - | - | - | - | - |
| 3.01 | (a) Upto 4th floor | 350 | Sqm | 349 ₹1,22,150 | 349 ₹1,22,150 | 324 ₹1,13,400 | 350 ₹1,22,500 | 300 ₹1,05,000 Lowest | 300 ₹1,05,000 Lowest | 346 ₹1,21,100 | 350 ₹1,22,500 |
| 3.02 | (b) 5th floor to 8th floor | 125 | Sqm | 399 ₹49,875 | 399 ₹49,875 | 356 ₹44,500 | 350 ₹43,750 Lowest | 350 ₹43,750 Lowest | 420 ₹52,500 | 366 ₹45,750 | 400 ₹50,000 |
| 3.03 | (c) above 8th floor | 50 | Sqm | 449 ₹22,450 | 449 ₹22,450 | 428 ₹21,400 | 350 ₹17,500 Lowest | 400 ₹20,000 | 440 ₹22,000 | 386 ₹19,300 | 450 ₹22,500 |
| 4.00 | Cleaning all existing reinforcement bars with wire brush/ rotary wire brush to make entire surface of bars free from rust scales, loose material, dirt etc. and applying alkaline rust converting primer on the existing rebars and allowing it to react with rust and form a corrosion resistant, insoluble protective layer, as per manufacturer’s instructions, etc. complete all as specified and as directed by Engr-in-charge. | - | - | - | - | - | - | - | - | - | - |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
19 Jul 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
REPAIRS AND RESTORATION OF STRUCTURAL MEMBERS LIKE COLUMN, BEAM, SLABS, ROOF PROJECTION OF OTM AND MARRIED ACCN INCLUDING E/M WORKS IN NOFRA AREA, CHUNABHATTI AND CIVILIAN OFFICERS MD ACCN AREA UNDER AGE B/R-I AT NAVAL STATION KARANJA
2025_MES_716112_1
84449-K/E8
Open Tender
Civil Works
Item Rate
180 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹1.4 L
20 Sept 2025
21 Jun 2025
21 Jul 2025
21 Jun 2025
19 Jul 2025
12 Jul 2025
Amount
Notes:- 1. Supplying & erecting steel scaffolding upto required height with top platform with support railing at top etc. The Scaffolding should be secured properly in position, complete as per site requirement & directions of Engineer-in-Charge. 2. Supply & fixing of dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair works in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system at shown area before start of work, removal after completion of work, carrying out regular cleaning etc. complete as per site requirement & directions of Engineer-in-Charge. 3. Supporting the structural components temporarily during repair and strengthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonally at centre with each other using suitable heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration, complete all as specified and directed by Engr-in-charge. 4. Structural rehabilitation work shall be got executed through one of the specialist firm(s) listed below as approved by GE prior to commencement of work :- (a) Rebuild Technologies Services Pvt Ltd 602, 6th Floor, Tulsee Chamber, Teen Petrol Pump, Thane (W) E (b) Techton Buildcons Pvt Ltd 203, Plot No 6, Millenium Plaza, Sakinaka Telephone Exchange Lane, Off AK Road Andheri E-Mumbai 72 (c) Sanrachana Structural Strengthening Pvt Ltd 103, 104, Monalisa CHS, Hariniwas Circle, Thane West - 400602 (d) USHTA Infinity Construction Co Pvt Ltd Ushta House, C-17/79 Krishna Industrial Estate, Gorwa, Vadodara - 390016 India (e) Gubbi Civil Engineers 18/26 Dev Prayag CHS, Opp Thanawala garage, Bhakti Mandir Road, Near Hari Nivas Circle Thane (W), Thane, Maharashtra 400602
Removing, chipping and cleaning of existing loose and damaged concrete carefully upto 60mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete including cleaning the surface by air jet and stacking & disposal of unserviceable materials outside the premises, etc. complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Providing and applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/litre and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation works, etc. complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Cleaning all existing reinforcement bars with wire brush/ rotary wire brush to make entire surface of bars free from rust scales, loose material, dirt etc. and applying alkaline rust converting primer on the existing rebars and allowing it to react with rust and form a corrosion resistant, insoluble protective layer, as per manufacturer’s instructions, etc. complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Material and labour for drilling Holes of 12mm dia up to 100 mm deep in structural members at the interval of 300 mm in staggered manner or along the crack line in RCC structural member including cleaning of the holes by air blower and inserting 12mm dia NRV nozzles compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix the nozzles inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 hrs before grouting; Cut and remove nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc., complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Material and labour for providing and injecting two part, low viscous, high strength epoxy resin based moisture insensitive liquid using pressure injector with accessories till nozzle refuses to accept the grout including mixing of grout material components in adequate proportions as per manufacturer's instructions by weight batching and grouting the mixed material into the structural member by grouting gun, maintaining desired pressure in the gun by air compressor and maintaining pressure at exit about 2 to 3 kg/sqcm by monitoring pressure gauge at exit, complete all as specified and as directed by Engr-in-charge. The mixed grout should have following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Material and labour for MS TMT bars for additional reinforcement and shear keys, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed by Engr-in-charge.
(a) For bars above 10mm dia.
(b) For bars of 6mm to 8mm dia.
Anchoring reinforcement bar (shear bar 150 mm length approximate) in existing RCC member in drilled holes and grouting in position with Epoxy resin anchor grout of approved brand, including drilling of holes, cleaning etc, complete all as specified and as directed by Engr-in-charge. (Bar shall be measured separately)
Material and Labour for providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in two coats to the entire circumference surface of bars. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement : per sqm of application area of concrete) complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Material and labour for providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or micro-concrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc, complete all as specified and as directed by Engr-in-charge. The product should comply with ASTM C 881 Type II Grade 2 Class B+C
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Material and labour for rebuilding the section of damaged RCC elements to its original size in thickness upto required thickness by providing and casting with ready to use non-shrink, cementitious free flow micro-concrete having compressive strength > 60 N/sqmm (28 days) according to ASTM C 1107-99 including, drilling holes and fixing shear connectors, mixing the micro-concrete with adequate quantity of water, placing, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any and curing complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Providing watertight formwork of timber planks so as to give a rough finish including centering, shuttering, strutting and propping etc., all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engr-in-charge.
(a) Upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Providing and applying ready to mix Cement plaster with high quality polymer additives with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc. complete as specified and as directed by Engr-in-charge.
(i) For 12mm thickness :- (a) upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
(ii) For 10mm thickness (Internal) (a) upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
(iii) For 5mm thickness (Ceiling) (a) upto 4th floor
(b) 5th floor to 8th floor
(c) above 8th floor
Material and Labour for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water & allow to dry. Fill visible cracks/ joints by caulking compound (chemistik crackseal or equivalent) & allow to dry for 24 hours. Apply a primer coat of water base primer (chemistik prime M seal or equivalent) and allow to dry for 6 hours. Thereafter apply 02 coats of WB high build anti carbonating coating cum waterproofing (chemistik PDS-50 or equivalent) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc, complete all as specified and as directed by Engr-in-charge.
Material and Labour for Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper on walls over a coat of chalk whiting primer, complete all as specified and as directed by Engr-in-charge.
Material and Labour for Preparation of new plastered surfaces and applying three coats of white wash on ceilings, complete all as specified and as directed by Engr-in-charge.
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by Engr-in-charge, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continuous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including 3mm hylam /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge, for one light point or one fan point controlled by one switch. Note : Wiring to be done as per approved colour code.
-Ditto - all as per item No 19.00 here-in-before but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
-Ditto - all as per item No 19.00 here-in-before but one 5 amp socket point on same board
-Ditto - all as per item No 19.00 here-in-before but one 5 amp multi socket, independent
-Ditto - all as per item No 19.00 here-in-before but using 2.5 sqmm ( nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi-purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
-Ditto - all as per item No 19.00 here-in-before but using 4 sqmm (nominal area) FRLSH multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano type flush button type single pole one way 5 Amps 240V front operated, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Switch socket combination 2 in 1, 3 pin, 5 A and 15Amp flush type universal, complete all as specified and directed by Engr-in-Charge.
Supply and Fix socket 3 pin 5 A flush type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell buzzer 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell push 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket type EME fan 5 step regulator switch/socket type for ceiling fan of suitable size, complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Lamp holder/angle holder insulated body with black/white plate for batten fittings, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular step type fan regulator 120 watt, AC, 220V, 50Hz ,ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular switch 1 module 6 amp one way ISI marked all specified and directed.
Supply and fix in repair/replacement modular switch 1 module 16 amp one way, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular socket 2 module universal type 5/6 amp one way, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular socket 2 module universal type 6/16 amp one way, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular bell push 6A 1 module, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement Bell buzzer, ding dong AC, 230V, 50 Hz single pole, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular cover plates with frame up From 1 /2 to 3 module as per site requirements, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular cover plates with frame up from 4 to 12 module as per site requirements, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular metal flush box as per site requirements from 1/2 to 3 modules, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular metal flush box as per site requirements from 4 to 12 modules, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/ suitable size , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/ recess complete including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/ recess complete including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in complete including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in complete including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in complete including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash, complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 W, IP 66 protection LED, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED batten with 20/22W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 8 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series), complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement SPN 32 AMP, 240V 10 KA (C-Series) , complete all as specified and directed by Engr-in-Charge.
Supply and fix LED recess/surface mounted 2x2 luminaire 36W fitting, 220 V, AC, 50Hz suitable surge protection, high power factor, driver etc complete including flexible wire and connected accessories, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC,50HZ connecting up with three core flexible copper conductor cable of suitable size complete with all accessories, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement LED tube rod 20 watt, 220V, AC, 50Hz change with existing any tube rod including flexible wire and connected accessories, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement Batten MS suitable for 18/22/24W LED rod 220V, AC, 50Hz with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten 10W, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fixin repair/replacement MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Material and Labour for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement three pin top of capacity 15 amp, AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement PCRD plug of capacity 15 amp, AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement emergency bulb LED 10W, 230V, 50Hz, with 2/4 hour backup, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement round/square type, recessed /surface 12W/14W warm white LED downlight dimmable with high lumen 230V, compatible with Legrand Dimmer as per sample as directed by Engr-in-charge.
Supply and Fix in repair/replacement RCCBs 63 Amps double pole 100mA breaking capacity, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement RCCBs 40 Amps double pole 100mA breaking capacity, complete all as specified and directed by Engr-in-Charge.
Supply and fix decorative light suitable for holder B-22/E-27, complete all as specified and directed by Engr-in-Charge.
Material and Labour for taking out and refixing of tube light, mirror light etc after cleaning and any type rectifying defect, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten with 20/22W LED tube light (four feet) with sensor in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix in repair/replacement LED batten with 9/10 W LED tube light two feet mirror type with sensor in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix in repair/replacement LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED bulb of 9/10 watt, complete all as specified and directed by Engr-in-Charge.
Material and Labour for servicing and cleaning of geyser of any capacity including taking out from existing position and refixing, complete all as specified and directed by Engr-in-Charge.
Material and Labour for checking ceiling fan of size 1200/1400mm and change defective part cotter pin/ nut bolt etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair GI strip 32mm x 6 mm saddle in wall for loop earthing and ground grid, complete all as specified and directed by Engr-in-Charge.
Supply and fix fan rod of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400, complete all as specified and directed by Engr-in-Charge.
Supply and fix flexible wire 1 sqmm x 2 core including taking out, complete all as specified and directed by Engr-in-Charge.
Supply & fixing, jointing, connecting & testing in saddle on wall 10 sqmm x 2 core, XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts/ including taking out cable cover & cable, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement modular type AC box with three pin socket and plug top and 20 amp single pole MCB, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 1000 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply and Fix test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator in wall as in repairs, complete all as specified and directed by Engr-in-Charge. Note :- Porcelain insulator will be measured & paid for separately.
Supply and Fix vitreous china porcelain insulator with busbar support white type, complete all as specified and directed by Engr-in-Charge.
Material and Labour for testing of Lightning Conductor & earthing except new earthing under item No 94 & 95 here-in-before of various Tech Accn in NAD area & Tunir Area in the presence of users representative & Engineer-in-Charge & maintaining record of tests for lightning conductor as per IAFW -2215 by removing all connection and the resistance of earthing & lightning protection network should not exceed 5 Ohm in every technical building showing the details of defective earthing & lightening protection system. Items to be repaired/renewal during record of sets for lightening conductors as per IAFW 2215 & also test results to be recorded after repair/renewal and should be signed by users, complete all as specified and directed by Engr-in-Charge. Notes :- (i) The earthing showing result beyond 10 ohm to be renewed and shall be measured & paid for separately under relevant item of Sch 'A'. (ii) The test result after renewal of earthing and replacement of defective conductor also be recorded in earthing test book as per IAFW-2215 for lightening conductor & cost for the same is deemed to be included in unit rate of above item. (iii) The unit rate quoted shall be deemed to be included for the test results of all existing earthing point, date of testing and renewal etc to be written on wall of each building in clear format like stencil etc as per direction from engr-in-charge with out any extra cost. (iv) The testing of new earthing covered under item No 94 & 95 here-in-before are not covered in this item.
Removing existing worn out CI cover with angle iron frame of earth chamber and supply and fix new CI cover of size 30 cm x 30 cm x 6 mm thick fixed in frame made out of mild steel angle iron 40 mm x 40 mm x 6 mm thick with and including locking and lifting arrangement, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 40 mm dia GI pipe medium grade for post not exceeding 3 metres in length truly vertical position embedded in PCC including not exc and earth work as in repairs, complete all as specified and directed by Engr-in-Charge. Note : PCC of pole embedded will be measured and paid separately under relevant items of Sch.
Material and Labour for PCC (1:2: 4) type BO, using (12.5 mm graded stone aggregate) of blocks size and IE rules including necessary use and waste of form work as in grouting of porcelain insulator, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC (1:2:4) type B1, using (20 mm graded stone aggregate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance not exc 50 metre and deposing where directed, complete all as specified and directed by Engr-in-Charge.
Removing & refixing of air termination single pointed aluminium rod 12 mm dia and 300 mm long by tightening with necessary fixing arrangement fixed on existing/new PCC blocks on roof and making good, complete all as specified and directed by Engr-in-Charge.
Supply and Fix aluminium strip of size 25 x 3.15 mm fixed with suitable saddle. Supply and Fixing screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, complete all as specified and directed by Engr-in-Charge.
Re fixing in repair only aluminium strip of size 20/25 mm x 3.15 mm fixed to porcelain insulator fixed with suitable saddle Supply and Fixing screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB, complete all as specified and directed by Engr-in-Charge.
Shri Krishna Trading Corporation (BID ID -3364083)
M.K Enterprises (BID ID -3364054)
BALAJI TRADERS (BID ID -3364334)
Mahadev Enterprises (BID ID -3364069)
Sagar Electricals (BID ID -3364807)
DIGITAL SERVICES (BID ID -3364734)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .