| 1 | L1₹40.3 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹46.2 L+₹5.0 L (12.1%)Rejected-Finance FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical not enlisted in cat c(vi)as per NIT |
| Sl No | Description | Qty | Unit | sapana enterprises L1 | M/s ASPIRE ENGINEERING ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed. | 0.5 | Qtl | 350 ₹175 Lowest | 2,000 ₹1,000 |
| 2.00 | Dismantling / taking out insulator of any size / type from existing electric LT lines complete all as specified and directed. | 24 | Each | 15 ₹360 Lowest | 200 ₹4,800 |
| 3.00 | Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed. | 1 | Each | 200 ₹200 Lowest | 400 ₹400 |
| 4.00 | Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as specified and directed. | 0.5 | Qtl | 450 ₹225 Lowest | 1,000 ₹500 |
| 5.00 | Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed..( Excavation and earth work will be measured seperately) | 2,410 | RM | 20 ₹48,200 Lowest | 60 ₹1,44,600 |
| 6.00 | M&L for scrapping of old alum paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces and painting with two coats of alum paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed. | 150 | Job | 290 ₹43,500 Lowest | 600 ₹90,000 |
| 7.00 | Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete all as specified and directed. | 25 | Each Job | 900 ₹22,500 Lowest | 1,200 ₹30,000 |
| 8.00 | Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete all as specified and directed. | 6 | Each | 1,200 ₹7,200 | 1,000 ₹6,000 Lowest |
| 9.00 | All as per item No.08 above but single phase and neutral conductor complete all as specified and directed. | 40 | Each | 1,100 ₹44,000 | 400 ₹16,000 Lowest |
| 10.00 | Cutting/trimming of trees upto 150 mm girth including cutting of upper portion of branches above pole clearance up to 10 mtrs and disposal of same at a distance not exc 50 mtr and clearing of site complete all as specified and directed.
(Note:Tools/ladder required for cutting/trimming of trees of any height will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.)
Note:Each Span will be measured from one pole to another pole | 60 | Each Job | 500 ₹30,000 Lowest | 1,000 ₹60,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Aug 2025, 6:00 pmClosed
GE AF LOHEGAON
Garrison Engineer Airforce Lohegaon PIN - 411032
Rep and Maint of LT distribution system feeder piller boxes Lt UG cable and misc items in viman Nagar 509 area burma shell 7 tettra and Akash Nagar area and maint rep replacement of def items of Fire Alarm system in 2 wg at AF stn pune under GE AFLoh
2025_MES_718943_1
8952
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Airforce Lohegaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹90,000
Yes
2 Dec 2025
7 Jul 2025
14 Aug 2025
7 Jul 2025
7 Aug 2025
25 Jul 2025
Amount
Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed.
Dismantling / taking out insulator of any size / type from existing electric LT lines complete all as specified and directed.
Dismantling of existing stay assembly any type / size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.
Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as specified and directed.
Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed..( Excavation and earth work will be measured seperately)
M&L for scrapping of old alum paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces and painting with two coats of alum paint on pole , brackets old junction boxes channels etc incl alternate 30 cm wide white and blue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed.
Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete all as specified and directed.
Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete all as specified and directed.
All as per item No.08 above but single phase and neutral conductor complete all as specified and directed.
Cutting/trimming of trees upto 150 mm girth including cutting of upper portion of branches above pole clearance up to 10 mtrs and disposal of same at a distance not exc 50 mtr and clearing of site complete all as specified and directed. (Note:Tools/ladder required for cutting/trimming of trees of any height will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.) Note:Each Span will be measured from one pole to another pole
Removing LT over head conductor from insulator where ever required and restretching the same without any kink / bend upto premissible sag, binding it on insulator by means of binding wire including fixing line seprator at 3 places in span of 30 mtrs and directed and testing LT over head line on completion and complete all as specified and directed.
Provn of services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below complete all as specified and directed.
25 to 50 sqmm 3.5 core complete all as specified and directed.
70 to 150 sqmm 3.5 core complete all as specified and directed.
185-240 sqmm 3.5 core complete all as specified and directed.
300-400 sqmm 3.5 core complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm complete all as specified and directed.
Taking down old unsv/broken pole and Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of pole complete all as specified and directed.
Material and labour for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections, including nut bolts, washer welding bending cold/ hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one premer coat of red oxide primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Material and labour for replacement of old broken ACSR with aluminium conductor steel reinforced streching without kinks / bends and binding with insulators on street poles complete all as specified and directed. ( Taking down shall be paid under separate item of BOQ)
S&F shackle type insulator vitreous procelain white / brown / green with and including galvanised mild steel straps, washer insulator, bolts and nuts, insulator of size 100mm height and 115 mm max dia with working pressure 1100 volt and galvanised steel straps 3 to 5 mm size and suitable size nut and bolts complete all as specified and directed.
M&L for providing pin type procelain white / brown / green / insulator including galvanised mild steel spindle, two galvanised iron. Washer and one galvanised iron nut, 100mm height 65 mm dia for 1100 volts grade complete all as specified and directed.
M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm all as directed
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation or as required on site etc complete all as directed by Eng-in-Charge
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as required on site etc complete all as directed by Eng-in-Charge
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles, PCC around LT/HT panels along with form work, excavation to depth upto 0.1 mtr all incl necessary form work using 20 mm graded stone aggregate etc or as required on site etc complete all as specified and directed.
Supplying, spreading & leveling stone aggregate size of 40 mm grade to the existing sub station or complete all as specified and directed.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified for following size:-
16 sqmm 4 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
150 sqmm 3.5 core
300 sqmm 3.5 core
16 sqmm 2 core
10 sqmm 4 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc complete all as specified and directed.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil complete all as specified and directed.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed.
Material and labour for crushed stone sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and punned down to 18 cm total thickness jointing and testing the cable complete all as specified and directed. [Note : Measuremenet will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks old size complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 630 Amps Adjustable type with breaking capacity 50 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 250 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 200 Amps Adjustable type with breaking capacity 25 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 160 Amps Adjustable type with breaking capacity 25 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity 25 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity 25 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 63 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning incl taking out unserviceable complete all as specified and directed.
Taking down old LT panel and Supply install, test and commissioning of Powder coated LT panel cubical Outdoor type double door, free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomer ACB/MCCB and outgoing feeders with MCCB/MCB. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The cubicle shall have free standing bottom frame/stand of height 700mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 Tank Process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation and making good as per existing, complete all as specified and directed.
Supply and fixing SP 5 To 32 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
All as above but SPN 32 Amps
All as above but TP 25 to 63 Amps 415 Volts
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed.
Opening/disconnecting the electrical connection of defective/burnt out underground LT Cable of any size 2 to 4 core from main switch/DB/ junction box / LT panel /LT OH line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable, providing required thimbles/ connectors at cable end and reconnecting the cable in previous location with existing main switch/ DB/Junction box /LT Panel/ OH line etc complete all as specified and directed.
Material and labour for getting out removing of grass and vegetation grown around the electrical installations like transformers, LT panels, 2 pole structure, HT panels and complete area inside the fencing complete all as specified and directed. Note : Item may be measured and paid more than one time as per detailed videography during execution at site as per site requirement to clean the E/M Installations
M&L for comprhensive mainenance of fire alarm system installed at various tech Bldgs of 2 wing comprehensive maintenance the following works including:- Note:- (i) The maintenance cost of fire alarm system shall deemed to comprises of cost of labour emplyed for the purpose , T&P used and other petty items such type and other cleaning materials, programming , re-programming etc. (ii) The scope includings programming, commissioning of accessories of fire alarm system to suitable for existing syste. (iii) Non attending the complaint with in 48 hrs @ 500.00/day shall be recovered for te fourth day by the contrator. (iv) Keep the complaint pending after 96 hrs @ Rs 1000.00/Day shall be recovered by the contractor. (v) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-in-Charge (v) Servicing of quaterly basis of fire alarm system installed in following Bldg including first hand repairs, consisting of normal repairs and cleaning of all components such as smoke detectors/manual call point sounder/translator/expendor/input/output module etc of any type installed in Bldgs using proper method and tools, replacement of unserviceable spares of connected system, tightening of all connections as repuired including replacements of defective spares and required calibration of control pannel and connected items check and maintain the system for efficent functiong of entire system including troubleshooting and clearance of all faults from the panel. testing of each Fire alarm system in presence User and MES Rep and give quaterly basis serivicibility report complete all as specified & directed by Engineer-in-Charge . Note major items i required for Repair shall be measured & paid seperaely unde respective item..
a) Base Ops b) FSS (avoinic lab) c) Tech Fly Hanger d)30 Sqd Hanger e) JTF Hanger f) 20 Sqd Hanger g) RT Cabin h) GCA Bldg (j) Logistic Bldg k) SRE Tower l) SSC m) SMC n) LDP Lab Bldg o) Simolator p) PTT
Taking down exising Beam Detector in replacement S&F Supply, Installation, Testing and Commissioning of Approved Projected Beam Detector 100 mtr range transreceivers type Complete set with all required module to be make it suitabe for existing fire alarm system • Should be Microprocessor based complete all as specified and directed by Engr-in-Charge. • Signal strength LED's • Should Provide linear protection • Automatic compensation for signal drift or dirty lens • Minimum Three field adjustable sensitivity settings • Form A alarm and Form B trouble contacts • Calibrated filters shall be vailable to verify sensitivity • Emitter and Receiver type
Taking down carefully from trench/wall/roof/trench of hanger/ building loose/hanging/deshaped of any size unserviceable cable etc complete all as specified and as directed.
Material and labour for supply and fix armored fire cable copper conductor of size 2 Core 1.5 sqmm two core FRLS in Red colour fixed on wall / roof with GI saddle complete all as specified and directed.
Supply only Hybrid Wireless Optical Smoke Sensor with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, in-built magnet test, operating on 865-868 MHz with communication range up to 1000 m in open air, 95% RH (non condensing), Primary & Secondary Power Supply LPCB Approved, Approved to EN54-7 & 25Bcomplete all as specified and directed. Make:- Hochiki to be compatible with Existing Fire Alarm System
Supply only Compatible Batteries for wire less detectors & MCP etc to be used in existing system installed complete all as specified and directed.
Supply only Wireless Translator Module with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, Loop Powered, allows the connection of up to 126* radio field devices to an addressable fire detection loop, Incorporates a Loop Short Circuit Isolator and an OLED display, operating on 865-868 MHz with communication range up to 1000 m in open air, 95% RH (non condensing), RED compliant, LPCB Approved, Approved to EN54-17, 18 and 25. complete all as specified and directed. Make:- Hochiki to be compatible with Existing Fire Alarm System
Supply only Wireless Expander Module with Bi-directional wireless communication, Self optimising wireless amplitude and frequency,Up to 126 Expander Modules may be configured to any one Translator Module, Supports MESH communications, operating on 865-868 MHz with communication range up to 1000 m in open air, 93% RH (non condensing), RED compliant, LPCB Approved, Approved to EN54-18 and 25 complete all as specified and directed.
Supply only Wireless Manual Call Point with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, Resettable Element, fully addressable and intelligent monitoring functionality operating on 865-868 MHz with communication range up to 1000 m in open air, 95% RH (non condensing), Up to 10 year battery life Dependant on operational usage, Primary & Secondary Power Supply, LPCB approved, Approved to EN54-11 & 25. complete all as specifed and directed by Engineer-in-Charge. Make:- Hochiki to be compatible with Existing Fire Alarm System
Supply only Wireless Sounder with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, 4 Tone Settings, fully addressable and intelligent monitoring functionality operating on 865-868 MHz with communication range up to 1000 m in open air with Max. sounder output 93 dB(A) @ 1 metre, 95% RH (non condensing), Up to 10 year battery life Dependant on operational usage, Primary & Secondary Power Supply, LPCB approved, Approved to EN54-3 and 25complete all as specified and directed. Make:- Hochiki to be compatible with Existing Fire Alarm System
Supply only Sealed lead Acid Battery CS 7-12, 12 V, 7 AH Chrge parameters, Constant Voltage Charge with voltage reguation (27 degree C) stanby use 13.6V -13.8V, cycle use -14.1 V-14.4V, Max initia current 1.4 A suitabe for Existing fire Alarm panel complete all as specified and directed.
Supply only Hybrid wireless input/output modle with BI directioal wireless cummunication self optimisng wireless communication self optimising wireless aplitude frequency upt oto radio field deice iput/output module an addressable fire ditection loop operating on 865-860 MHZ with commuication rage up to 100 m in open air 95% RH (Non condensiing LPCB PCB approved to EN54 , Make hochiki
M/s ASPIRE ENGINEERING ENTERPRISES (BID ID -3386498)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .