Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹24.5 L+₹58,013 (2.43%)Rejected-Finance | L2 | Rejected-Finance Not being a
lowest
tenderer | |
| 3 | L3₹25.0 L+₹1.1 L (4.57%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L3 | Rejected-Finance Not being a
lowest
tenderer | |
| 4 | L4₹27.4 L+₹3.5 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Not being a
lowest
tenderer | |
| 5 | L5₹28.3 L+₹4.4 L (18.2%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L5 | Rejected-Finance Not being a
lowest
tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
REPAIR/ MAINT AND COMPREHENSIVE MAINT TO SECURITY LIGHTS WITH LED LIGHTS AUTOMATICS SWITCHES POLES, DISTRIBUTING CABLE AND OTHER MISC WORKS AT SAF CAMP, AMN DUMP, TANKODROM, AND ADJOINING AREA UNDER GE BABINA
2022_MES_503042_1
GE/BAB/TOKEN/64 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
184 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹50,000
Yes
14 Mar 2022
21 Jan 2022
19 Feb 2022
21 Jan 2022
17 Feb 2022
5 Feb 2022
60 days
Amount
Excavation in trenches in any type of soil not exe 1.5 mtrs wide and not exe 1.5 mtr in depth for laying of pipe/cables/erection of pole etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
Excavation in trenches in any type of soil not exe 1.5 mtrs wide and exe 1.5 mtr in depth for laying of pipe/cables/erection of pole etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed.
M&L for dry clean sand (river sand) free from sharp materials laid for under ground electric cable cushioning laid in trenches in layers complete all as specified and directed
Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed. Make: M/S MEHATAB TILES, Rani Shopping Centre, Bhanwar, Indore,(B) M/S SAP PAVERS JODHPUR (C) SAGAR TILES Saharanpur ( D) SUPREME TILES (E) NITCO (F) NAVYA TILES JODHPUR
M&L for PCC 1:3:6 type C 2 using 40mm graded stone agg as in filling and mass concrete etc complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping of pole inclding providing form work where necessary complete all as specified and as directed. Note : Cost of form work deemed to be included in unit rate quoted by the tenderer.
Supply , laying , connecting and testing in replacement of cable XLPE insulated screened , PVC bedded , galvanised steel iron strip or wire armoured electric power cable heavy duty 1100 volt grade with multi stranded aluminium conductor of size 16 sqm 4 Core as per IS -7092 Pt-I etc complete including taking down/out old unsv UG cable/ACSR conductors from any location as direcetd etc complete all as specified as dircted.Make of conductor for all similar items of BOQ : Plaza/Paragon/Grandlay/HPL/ KEI/Finolex/Asian Cable Co /Universal/RPG Cables
Supply , laying , connecting and testing in replacement of cable XLPE insulated screened , PVC bedded , galvanised steel iron strip or wire armoured electric power cable heavy duty 1100 volt grade with multi stranded aluminium conductor of size 10 sqm 4 Core as per IS -7092 Pt-I etc complete including taking down/out old unsv UG cable/ACSR conductors from any location as direcetd etc complete all as specified as dircted.Make of conductor for all similar items of BOQ : Plaza/Paragon/Grandlay/HPL/ KEI/Finolex/Asian Cable Co /Universal/RPG Cables
Supply , laying , connecting and testing in replacement of cable XLPE insulated screened , PVC bedded , galvanised steel iron strip or wire armoured electric power cable heavy duty 1100 volt grade with multi stranded aluminium conductor of size 10 sqm 2 Core as per IS -7092 Pt-I etc complete including taking down/out old unsv UG cable/ACSR conductors from any location as direcetd etc complete all as specified as dircted.Make of conductor for all similar items of BOQ : Plaza/Paragon/Grandlay/HPL/ KEI/Finolex/Asian Cable Co /Universal/RPG Cables
M&L for replacement of new generation energy saving and environmental friendly long life LED street light of capacity 45 watt made up of innovative die cast aluminium housing with toughened glass high power individual LED with secondary optics as lighting source with IP 66 protection, pf not less than 0.95, of capacity 45 watt, input voltage of 150-240 volt (nominal rated voltage 240 Volt) with complete including taking down of old unserviceable street light any type/ any capacity all as specified and directed. Make Crompton/C&S/Syska/Jaguar & Co Pvt Ltd/ Philips/ Wipro/ Siemens
M&L for replacement of new generation energy saving and environmental friendly long life LED street light of capacity 70/72 watt made up of innovative die cast aluminium housing with toughened glass high power individual LED with secondary optics as lighting source with IP 66 protection, pf not less than 0.95, of capacity 45 watt, input voltage of 150-240 volt (nominal rated voltage 240 Volt) with complete including taking down of old unserviceable street light any type/ any capacity all as specified and directed. Make Crompton/C&S/Syska/Jaguar & Co Pvt Ltd/ Philips/ Wipro/ Siemens
M&L for replacement of new generation energy saving and environmental friendly long life LED street light of capacity 90 watt made up of innovative die cast aluminium housing with toughened glass high power individual LED with secondary optics as lighting source with IP 66 protection, pf not less than 0.95, of capacity 45 watt, input voltage of 150-240 volt (nominal rated voltage 240 Volt) with complete including taking down of old unserviceable street light any type/ any capacity all as specified and directed. Make Crompton/C&S/Syska/Jaguar & Co Pvt Ltd/ Philips/ Wipro/ Siemens
S&F high performance LED FLOOD light fitting 50 Watts power consumption made of pressure die cast housing with IP 66 rating input voltage range 110-240 Volts ( nominal voltage range -240 Volts ) etc complete as specified and as directed. Make: – Bajaj, Havells, Philips,Crompton, Wipro
S&F high performance LED FLOOD light fitting 100 Watts power consumption made of pressure die cast housing with IP 66 rating input voltage range 110-240 Volts ( nominal voltage range -240 Volts ) etc complete as specified and as directed. Make: – Bajaj, Havells, Philips,Crompton, Wipro
S&F in replacement of GI bracket for fixing of LED street light fitting fabricated out of GI tubing 32 mm dia medium grade 1.2 mtr bend at 120 degree angle and to shape as directed incl cutting, welding and finishing and including providing mild steel flat iron clamp made of 32x4 mm with nut, bolts, washers etc complete as specified and as directed. Make: Jindal/Tata/ BST.
S&F MCB SP 40 Amp 240 V ,10KA ,'C' series,complete all as specified and as directed with copper lugs. Make : Standrad/ L&T/ Havells/Indoasian/HPL/Schneider/ABB/C&S
S&F MCB SP 63 Amp 240 V ,10KA ,'C' series,complete all as specified and as directed with copper lugs. Make : Standrad/ L&T/ Havells/Indoasian/HPL/Schneider/ABB/C&S
Supply & Erection Prestressed concrete pole 9 mtr long , 102 mm x 172 mm at top and 102 mm x 279 mm at bottom Class 10 and including making strip alternately in white and black colour of 30 cms wide ( Total 05 Nos strips) and numbering the poles with 2" height letters in synthetic enamel paint tint as directed complete all as specified and directed. Note: (i) The Excavation /earth work & PCC shall be measured and paid seperately under relevant items of BOQ (ii) The cost of RFR ,Removal & Form work shall deemed to be included in unit rate quoted by the tenderer. Make: M/s Hindustan Pre stressed Concrete structure Faridabad/ M/s Cement Fabrics India Jodhpur/M/s Sankla Udyog Jhansi / M/s Mohan Concrete Udyog Lucknow
Supply , fixing , commissioning & testing of outdoor type bus bar panel pedestal type weather proof CPRI approved MS cubical panel board made of 3 mm thick CRCA sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 200 Amp capacity , 25 KA , 4 pole (Ics = Icu = 100%) including powder coated painting as per practice , mounted on angle iron of size 50x50x6 mm thick and fdn of plateform for the panel with lean concrete in PCC 1:4:8 type D-2 with 40 mm graded crushed stone, Base of plateform shall be in PCC 1:2 :4 type B-2 using 40 mm gradded stone aggregates,upto 300 mm height bolt shall be grouted monolithecally with PCC . Total height from Avg GL shall 450 mm for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. :- Make of Panel :- JUHI ELECTRICALS /SHALABH/ C&S ELECTRIC LTD /ACCURTAE /UNIVERSAL SWITCH GEAR / BSPL BHOPAL/MCLAYERS BHOPAL Make of MCCBs : Make : Standrad/ L&T/ Havells/Indoasian/HPL/Schneider/ABB/C&S Note (i) :- Panel drawings & make of MCCB/SDFU will be submitted by contractor for approval from Accepting Officer before ordering the panel Note (ii) The above makes are subject to their possessing of CPRI test report for equivalent rating. : Note (iii) : Pr voucher/ Tax invoice required to be submitted by the contractor at the time asking payment against item
S&F replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of 4 pole copper connectors of 16 Amps capacity with 6 Amp MCB ,SP, of minimum size 300x200x125mm,fixed on pole with MS, clamps of size 30x5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box and incl 3 core copper conductor cable 1.5 sqmm ISI Marked from kiosk box to security light complete all as directed.Note: The quoted rate deemed to be included cost for copper cable of 3x1.5 Sqmm , painting & MS clamp at site . Make of kiosk box : Sintex/Hensal/Supreme Industries
Supply and fix precast RCC cable path indicator indicator of size 900x300x40mm casted in RCC (1:1:1/2 :3) type B-0 using 12.5 mm graded stone aggregates and using 6 mm dia TMT bars ,finish smooth , duly painted with synthetic enamel paint of red/yellow as direcetd and marked as LT cable as directed and installed 600 mm above the and 300mm below the avg GL and grouted in PCC 1:2:4 type B_1 using 20 mm graded stone aggregates etc complete and as directed. Note : Quoted rate shall deemed to be included of all materials requied for casting nad finishing work
M & L for road cutting ( Bituminious road ) by necessary excavation 45 cm wide and .60 cm in depth as in trenches in any type of soils/rock for laying cables /tubes the pipe laid in trenches and filling top 30 cm with PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 10 cm thick hard core of broken boulders , 63 mm gauge over 15 cm thick bolders of 100 mm dia size filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
Supplying and laying GI pipe 50 mm bore medium grade including providing fittings such as elbow, Tee, socket etc laid on floors/trenches/walls with complete fixing arrangements and testing etc complete all as specified and directed .Make: Jindal/Tata/ QST
Disconnecting power supply from defective /unserviceable street light/ security light/ high mast light/flood light fitted on 11 mtr/9 mtr/8.5 poles and testing / checking for defects, testing LED drivers, fuse, testing kisok box, over head line connection, tightening of loose nuts bolts of GI brackets on pole, checking connecting wire from pole etc and fixing the repaired / services light fittings on poles and testing & commisining of light. Note :- (i) All spare like LED drivers, connecting cable, pole box, MCB in pole box etc and refixing in replacement will be measured & paid separately under relevant item. (ii) All necessary T&P (like ladder of suitable height and safety belt) for testing & repair of light fitting will be provided by contractor with out any extra cost. (iii) Contractor will depute one technician and one helper daily repairs & maintenance of security lights as directed (iv) Contractor will carry out daily repair & maintenance of security light as directed. Contractor has to understand the nature of wks under this item & quote his rate accordingly. (v) Complaints of unserviceable light fittings will be given by JE E&M to contractor/contractor’s rep to technician on mobile phone followed by writing. Contractor has to arrange required material, T&P & safety equipments to repair the security light within 72 hours from the time of intimation failing which a penality of Rs. 500/- per light per day (beyond 72 Hrs) will be charged and recovered from contractor dues.
S&F in replacement of LED drivers of LED streeet light /flood light of any make , of capacity 30 watts to 60 watts including replacement of burnt drivers carefully and as direcetd
Description all as per item no. 27 above but 70 watts to 90 watts and ditto-
Description all as per item no. 27 above but 100 watts to 150 watts and ditto-
Supply , fixing and testing of LED bulb panel inside the LED flood/Security light of capacity 30 watts to 70 watts including taking down old unserviceable LED panel including repalcement through soldering etc complete . Note: Quoted rate includes necessary parts required for replacement for commissioning of LED lights
Description all as per item no. 30 above but 90 watts to 150 watts and ditto-
Supply and fixing of single phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is < 30 LUX and for switching OFF >10 Lux level. The sensor (nature switch) along with suitable power contractors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress single phase 8KW lightning load capacity including mounting bracket, cable glands, front openable door fitted with hinges & locking arrangement complete all as specified and directed. The contractor MCB and circuit wiring should suitable enough to take load of 8 KW equally distributed over three phase and street light timer should be comprising of following :- (a) Input MCB rating 63 Amps (b) Contactor MCB rating 63 Amps (c) Out put MCB rating 63 Amps (d) Single phase circuit wiring minimum 16 Sqmm multistranded copper wire. (e) Model No : SWADEEP-02EC 8KW1P. Make :- Kakatiya Energy Systems Ltd
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 3.0 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 3.0 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead of GI flat 32x6 mm thick by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M/S S K AGARWAL
AUTOMATION AND SWITCHGEAR CONTROL
m/s gupta trading
M/S Kharya Associates
M/s BRIJ KUMAR RAI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .