Executive Engineer University of Kashmirq
Construction Division
Supply, fixing, testing and commissioning of wall mount Split ACs in Automation Section at Examination Block, Main Campus, University of Kashmir
2026_UDJK_319538_1
F(E.Tend)(S/F/T/C AC Auto. Sec.)(UCD)/KU/13/26
Open Tender
Electronics Equipment
Percentage
20 days
Main Campus
As per NIT
4 documents required · 4 mandatory
₹200
Registrar University of Kashmir
₹8,640
31 Aug 2026
8 Aug 2026
18 Aug 2026
8 Aug 2026
17 Aug 2026
8 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, fixing,testing and commissioning of 2TR wall mount Split AC Hot & Cold, COP cooling 3.04, COP heating 3.54, Maximam power 2.220KW, Current cooling/ heating not more than 9.06A Maximam Operating pressure Hi 42.9/Lo22.6 bar (3 and above star Ratting) wall mounted split fully inverter type AC with Heat Pump, fan coil unit and condensing unit Hot and Cold operation temperature range should be minimum -10(minus) to 46 degree C Inverter technology . including control wiring, AC remote with cells, Refrigerant Gas filling comlete in all respects. (Mitsubishi, O General, Toshiba or equivalent) | 4 | EACH | 83,000 | ₹3,32,000 |
| 2 | SITC of 2x copper piping (soft ) with 9mm nitrite rubber insulation on both pipes with steel clamps and including fully GI clamps & Tapping | 28 | R.M | 1,490 | ₹41,720 |
| 3 | Supplying and fixing of medium class PVC pipe of requied size along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | 8 | R.M | 145 | ₹1,160 |
| 4 | SITC of control and power cable for connection of indoor and outdoor units as per specifications of OEM | 15 | R.M | 250 | ₹3,750 |
| 5 | Supply and fixing of M.S Stands for outdoor units as per specifications of OEM | 4 | EACH | 1,200 | ₹4,800 |
| 6 | Supply of 5KVA Automatic Voltage Regulator (AVR) Air cooled wall mounted having input line voltage from 90 volts to 260 volts with tme hi, low cut and time delay protections. Including required length of recommended leads of reputed make | 4 | EACH | 9,900 | ₹39,600 |
| 7 | Providing and fixing of AC points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 32 Amp. of Modular MCB, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all respetsnote: all items included like Conduit/ CHANNEL, wire, PVC/MS box, switches etc. | 2 | POINT | 4,500 | ₹9,000 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_1058776.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .