Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹51.7 L+₹2.2 L (4.42%)Rejected-Finance BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹52.1 L+₹2.6 L (5.20%)Rejected-Finance SHOP NO 04 AKBAR ARCADE NEAR INDRAYANI BRIDGE LONAVLA PUNE 410401 | PUNE | MAHARASHTRA | 410401 | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹52.5 L+₹3.0 L (5.98%)Rejected-Finance | L4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L5₹53.4 L+₹3.8 L (7.71%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L5 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹49.0 L
EMD Value
₹98,000
Closing Date
27 Mar 2024, 6:00 pmClosed
Shri Gaurav Tiwari, IDSE, EE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPL REPAIRS TO CHAIN LINK FENCING IN OMA (BLDG NO P-273, P-274, P-275, P-276 and P-277) IN RAJENDRA NAGAR and ROOF OF SAGAR COMMUNITY HALL (BLDG NO P-465) AT NSB AT INS SHIVAJI LONAVLA
2024_MES_644681_1
GE/LONAVLA/8222/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹98,000
Yes
15 Apr 2024
29 Feb 2024
29 Mar 2024
29 Feb 2024
27 Mar 2024
14 Mar 2024
29 Feb 2024 - 13 Mar 2024
Amount
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for cement concrete type D-2 1:4:8 using 40 mm graded stone aggregate in filling foundation , sub base of floor and mass concrete complete all as specifed and directed. .
Material and labour for cement concrete type C2 1:3:6 (20mm graded stone aggregate) foundation filling of mass concrete complete all as specified and as directed
Material and labour for providing 75mm thick plain cement concrete (1:3:6) type C-2 , using 20mm graded stone aggregate , laid in 1:20 slope in alternate bays as in plinth protection, surface finished even and smooth without using extra cement, complete all as specified.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specifed and directed. .
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6 including demolition.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified.
Material and labour for prepration of newly plastered surfaces on walls and applying two coat of cement base paint with priming coat of plastered surface area and other surfaces with chalk whiteing complete all as specified .
Dismantling posts or struts (wood ,steel or RCC ) any section ,including taking out embaded portion concrete ,brick work ,masonary,etc and making good disturbedground.
S&F joist channel,angle,or tee sections fixed indipendently,with out connecting plates ,etc. cut ordinary length ie., with in 20 mm of length indicated conforming to Fe410-Wgde-E-250 Quality A complete all as specified.
S & F hand rail other steel section or core for wooden hand rail stright portion ,drilled andcountersunk for blasters running bars for doors balusters,nosing to steps including embading in concrete and screwing etc wind ties for roofing including securing bolts for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165
M&L for two coats of synthetic enameled paint on steel and iron surface over 10 cm width or girth including preparation of new surface over a coat of red oxide primer complete all as specified and directed.
Dismantling of barbedwire wire mes of any type etc complete all as specified
Fixing for chain link fencing including line wires, any mesh, size, rails, straining bolts, etc. including provision of binding wire. (Chain link fencing and line wire shall be paid at supplied only rate) complete all as specifed and directed.
Supply only chain link fencing & line wire, MS galvanised of any size and type complete all as specified and as directed.
Dismantling of manglore pattern roofing/ tiles or terracing tiles, single layer on roofs including concrete bed frame for eracting tiles of size 50mmx75mm etc,complete all as specified and as directed by EIC.
Roughening surfaces of concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3kg / sqm over cleaned roof surfaces complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type BO (using 12.50mm graded stone aggregate) for roof ,kerbs or mud stops,rounded or chamfered on eds etc including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cement over existing roof and in padding concrete to maintain required slope and minimum thickness being 25 mm complete all as specified and as directed by Engr-in-charge. Note:- Admixture SP-430 chemicals will be measured and paid separetly under respective item.
Supply only of admixture fosroc SP 430 Chemical all as specified and as directed by the Engineer-in-Charge.
Material and labour for screed bed layer 5mm thick in CM 1:4 on concrete surfaces of roof, mixed with integral water proofing compound @ 3% by weight of cement, finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured and paid separetly under respective item.
Supply only Liquid water proofing compound
Material and labour for cleaning the entire roof surface thoroughly to remove all loose particles,dust/dirt particles and applying with one coat of industrial bitumen 85/25 grade at the rate of 1.20 kg/sqm over the plastered surfaces of roof over APP based polymeric membrane minimum weighing 3kg/sqm and minium 3mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/ sqm) laid on primed surfaces by gas flame torch application and applying evenly industrial bitumen 85/25 grade at the rate of 1.20kg/sqm over APP membrane complete all as specified and as directed by Engr-in-charge. Note:- Make/ brand of APP modified membrane with all associated items shall be any one of Super Thermolay of STP Ltd or Torch Sheild 'P-3160' of Pidilite Industries Ltd or Hyper Plas Polyster of IWL (INDIA) Limited or Super Sheild of M/s Shalimar Bituchem India Pvt Ltd or Torch Tor of Torch Tor Membranes and Bitumen Products Pvt Ltd.
Material and labour for two coats Aluminium paint over APP based polymeric membrane complete all as specifiedand as directed by Engineer -in -charge.
Removing of excavated material /demolised building materials/ debris etc to a distance exc 1.50km but not exc 5km and deposited where Defence land area or as directedby Engr-in-charge.
Dismantiling of water tanks exc 500 ltrs but not exc 1000 Ltrs from store / site complete all as specified
S&F in repairs 1000 ltrs Rotational mould polyethylene water storage tanks triple layered (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed.
M&L for, ‘ GI tubes medium grade’ galvanised, 15 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors including taking down existing GI pipe 15 mm and removing from site all as specified and as directed.
M&L for GI tubes, ‘medium grade’ galvanised, 20 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors including taking down existing GI pipe 20 mm and removing from site all as specified and as directed.
S&F in repairs Bib taps, fancy type, chromium plated with crutch sc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed.
S&F in repairs Stop valves, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch , screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs Angle cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S/F in repair Ball valve of size 20 mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed ( Make:- PRAYAG / SYMET).
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20 mm bore complete all as specified and directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repairs Low / high level flushing cistern 10 ltr capacity, PVC valveless, syphonic action incl waste pipe, pair of CI brackets and all accessories complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, and thickness including Nainital pattern or similar roof covering, etc complete all as specified.
Supply and fix for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in framed roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-charge.(colour as approved by GE)
Supply and fixing Pre -painted galvatume aluminum Zinc coating GI based Plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covring /cladding to wall , and valley gutter fixed with self tapping screws as specifiedand as directed by Engr-in-charge.
Supply and fix gratings doom 110 mm dia of stainless steel fixing with white cement (minimum weight of 30grm)complete all as specified and as directed by Engineer-In-charge.
m&l for PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixing of walls 75 /110mm bore complete all as specified.
S&F Cast iron work grade FG 150 , unmachined in bracket, over head tank covers, fire and soot doors, dampers, stop valve boxes,gate stop, parts of ranges, bausters exc 5 kg each and similar articles all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles and rubbish off the premises etcand removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (desined pattren) (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors laid over 15mm thick screed bed in CM 1:6 . set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Glazed (Coloured) ceramic tiles in vertical surfaces 300 x 450 x 8 to 9 mm/ 450 x 350 x 8 to 9 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match etc,including rendering 10 mm thk in CM (1:4) as in backing coat of cement plaster for laying of wall complete all as specified and directed.
Taking down cement or cement lime plaster on brick masonary or concrete surface in wall and ceiling etc including raking out joints, hacking for keys, scrubbing down with water etc and removing rubbish outside MD land etc complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified.
M&L for 15 mm thick rendering in CM 1:4 on stone / Brick masonry of wall ,chajjas , etc finishing the surface even and smooth without using extra cement complete all as specifed and directed
Material and labour for preparation of plastered or unplastered old decorated surfaces of celings including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and grease spots, washing etc. and applying one coat of white lime wash complete all as specified.
Material and labour for complete removal of existing treatment of old ,new platered surface of wall surfaces and praparing and applying two coat of acrylic distember 1 quality (ready mix) having VOC content less than 50gms/litr ,of approved manfacturer,of required shade and colour complete as per manfacturer's specification over alkali resistance primimg paint primer over 3.00 mm thick white cement based wall care putty smooth finish etc complete all as specified and as directed. Note:necessary saftey precautions , ladder/scaffoliding etc arranged by contractor.
Material and labour for complete removal of existing treatment of old,new platered surface of wall surfaces and praparing and applying two coat of weather coat paint over alkali resistance primimg paint one coat of primer smooth finish etc of approved make & shade on walls and other places complete all as specified and as directed. Note:necessary saftey precautions , ladder/scaffoliding etc arranged by contractor.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. (a) One light point or one fan point controlled by one switch
(b) One 3 pin socket outlet, 5 Amp independent
(c) One 3 pin socket outlet, 5 Amp on the same board with other switches
All as per item No.2 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
Supply and fixing Batten 1x18W(single side supply)for LED TUBE LIGHT pre -coated CRCAA sheett, end caps made up with engineering plastic all as specified and directed.Make : Bajaj (BLRB - DB 118) or equivlent PhilipsHavells.
Supply and fixing ROD 1x18W (single side supply)for LED TUBE LIGHT T8 tube with polycarbonate body all as specified and directed.Make : Bajaj (BLRB - 20W LED) or equivlent PhilipsHavells.
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
Supply and fixing LED Building light/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.Note:- Cost of making hole for Exhaust fan of required size at site is deemed to be included in qoted rates.
M&L for earthing complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
S&F MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed Make:Havells QVE series or equivlent legerend/standard/indoasian
S&F MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed Make:Havells QVE series or equivlent legerend/standard/indoasian
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA ''C''&''B'' curve , as per site requirment,Complete all as specified and directed.
S&F in repairs MCB SPN 6-32 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
Supply and fixing MCB TPN/FP 40 To 100 AMP 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
Supply lay and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 35 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed.
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x4.0 sq. mm +1 x4 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:-Two run of 4 sqmm wire and One run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter, and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of quarter after repair works completed.
Supply and fixing Higher wattage flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 50W LED ) or equivalent philips/Havells.
Supply and fixing wall mounted fan size 450 mm , 100w air delivery for commercial uses rpm not less than 1400 all is specified and directed by engr-in-charge.(Make:Havells /philips/bajaj)
Removing of existing lighting protection system with including air termination aluminium rod, connecting strips, test point terminal block,bolts,nuts etc complete all as specified and as directed.
Supply & fixing air termination, GI LA with base plate, 16mm dia and 1 mtr in length ,cylindrical type 4 spike (solid) long on aluminium/copper strip including provison holes & bolts for fixing complete all specified and directed.
M&L for fixing Aluminium strip 25 mmx 3 mm complete with saddles and fixing screw for fitting the strip complete all as specified and as directed. (Note:-Qoted rates are inclusive of drilling and new GI screws/nut bolts).
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and as directed
M&L for fixing of insulator BMD 40 for mounting of earth continuity conductor complete all as specified and as directed.
M&L for 40mm dia MS pipe bracket 450mm long with flange welded at the one end and arrangement for mounting of air termination rod at the other end complete all as specified and as directed.
M&L for cement concrete Type B1 (1:2:4) 20 mm graded stone aggregate as in support blocks of size 150x150x150mm complete all as specified and as directed by EIC at site.
seema enterprises
KGN builders
RK AND SONS CREATION
SAI SAMARTH ENTERPRISES
Durga Enterprises
United Engineers and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .