| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.6 L+₹3.0 L (21.0%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹18.8 L+₹4.3 L (29.8%)Rejected-AOC | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹24.2 L+₹9.7 L (66.8%)Rejected-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
23 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR/REPLACEMENT OF INTERNAL WIRING, DBS, MCBS, SUBMAIN WIRING AND OTHER CONNECTED ITEMS AT AF STN THOISE UNDER GE AF THOISE
2022_MES_542259_1
GEAF/T-23/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
As per Tender Document
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹44,000
Yes
28 Sept 2022
1 Aug 2022
25 Aug 2022
1 Aug 2022
23 Aug 2022
8 Aug 2022
60 days
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed by Engineer-In-Charge.
Taking down unserviceable any type of submain wiring etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and as directed by Engineer-In-charge.
M&L for point wiring with 1.5 sqmm copper conductor FRLS (multistranded) PVC insulated and unsheathed electric cable 1100 volt (ISI Marked) with proper color coding in and incl PVC casing and caping and accessories (ISI Marked) with all fittings/accessories and incl PVC insulated and unsheathed electric cable 1100 volt 1.5 Sqmm FRLS (multistranded) copper conductor cable(green color) as continuous earth wire connected to common earth dolly incl hard PVC boards of required size and shape and fittings etc covered with 3mm thick plastic laminated sheet (Make: Hylum) for one light point controlled by one,one way switch, and complete all as specified and directed at site by Engr-in-charge. Make of wire: Anchor/Polycab/Finolex/ Havells
All as per BOQ serial item No- 3.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board complete all as specified and as directed by Engineer-In-charge.
All as per BOQ serial item No- 3.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board complete all as specified and as directed by Engineer-In-charge.
All as per serial item No- 3.00 here-in-before but for one light point controlled by two way switches complete all as specified and as directed by Engineer-In-charge.
All as per BOQ serial item no 3.00 here in before, but 2.5 Sqmm copper conductor FRLS (Multistranded) PVC insulated and unsheathed electric cable 1100 volt (ISI marked) and 2.5 Sqmm copper conductor as continuous earth wire for 3 pin socket multipurpose 15 Amps on independent board, and complete all as specified and directed at site by Engr-in-charge. Make of wire: Anchor/Polycab/Finolex./ Havells
M&L in replacement of Sub main wiring (in existing concealed conduits to surfaces) for circuits/ sub main wiring alongwith earth wire with two run of 4.5 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC Casing caping, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ serial item No- 8.00 here-in-before but for sub main wiring (in existing casing caping to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts complete all as specified and as directed by Engineer-In-charge.
M&L in replacement of 1.5 Sqmm Copper cable single core complete all as specified and as directed by Engineer-In-charge. Make : Polycab/finolex/Anchor/Havells
M&L in replacment of 2.5 Sqmm Copper cable single core complete all as specified and as directed by Engineer-In-charge. Make : Polycab/Finolex/Anchor/Havells
M&L in replacement Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Switch piano, flush type, single pole, two way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement of Switch socket combination 2 in 1, 5 A , ( Box Type) and complete all as specified and directed by Engr-in-charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement of Switch Socket combination 2 in 1 , 3 Pin 5 and 15 Amp Flush ( Box Type) type universal complete all as specified and directed by Engr-in-charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Bell push switch, single pole, one way, flush type, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Door bell, AC, 230 Volts, single pole, ding-dong type sound, complete all specified and as directed by Engineer-In-charge. Make: Cona/SSK/Leader/ Anchor/Havells
M&L in replacement Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement MCB, Single Pole and Neutral, 20 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement MCB, Single Pole and Neutral, 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement MCB, Single Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement MCB, Triple Pole and Neutral, 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement MCB, Triple Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement MCB, Triple Pole and Neutral, 100 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider/L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen
M&L in replacement Replacement of old unserviceable/ damaged MCB with new MCB, TPN, 415 Volts, adjustable thermal and fixed magnetic setting, 125 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
M&L in replacement Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
M&L in replacement LED retrofit lamp, T-shape, capacity 12 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ cool white light, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- NU Bulb Plus 12 W 865 B22 3 Star (Ordering code-LHLDEUECNL8R012)/ Philips/ Osram/ Crompton/SYSKA.
M&L in replacement LED tube light fitting, 20 watt, indoor decorative high lumen batten, including LED lamp 20 Watt (yellow/white) and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Curve LHEXACP7IN1S024 or equivalent in Cromtopn/ Philips/SYSKA.
M&L in replacment Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 15 Watt, complete all as specified. Make: Crompton/ C&S/ Bajaj/Havells/Philips/SYSKA.
M&L in replacment LED tube light fitting, 1-feet long, indoor decorative high lumen batten, including LED lamp 5 Watt (yellow/white) and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed. Make: C&S cat part No- LTTB1F5WLED/W or equivalent in Bajaj/ Philips/ Wipro/Crompton Greaves/SYSKA.
M&L in replacment Ceiling light, size 600x600mm, with bright LEDs of 36 Watt, having superior illumination, complete all as specified and directed by Engineer-In-Charge. Make: Crompton cat part No- CCR-127-36-57-SL-NWH (Aura-I) or equivalent in Phillips/ Havells/ Wipro/BAJAJ/SYSKA.
M&L in replacment Bldng Security light fitting, Pressure die-cast IP 66 LED street light, including LED lamps of 30 to 36 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- Endura Pearl SL30WLED757SASYTOPCMP/ Philips ordering code No- 910925863567 (Product Code: 871869637692800)/ Bajaj cat part No- 16991or equivalent in BAJAJ/SYSKA/Crompton Greaves/Wipro .
M&L in replacment of service wire of Aluminium conductor of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-In-Charge. Make : Kalinga/ Plaza/ Havells/Polycab
M&L in replacment of service wire of Aluminium conductor of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-In-Charge. Make : Kalinga/ Plaza/ Havells/Polycab
M&L in replacmentof old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes/ laid along the road, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ serial item No- 44.00 here in before but for cross-sectional area 16.0 Sqmm, 2.0-core complete all as specified and as directed by Engineer-In-Charge.
M&L in replacment Modular switch piano, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacment Modular socket outlet, 2-in-1, 3-pin, 5-Amps, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacment Modular Switch socket combination 6Amps/ 16Amps, 2/3-pin combined, one-module, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacment Modular white cover plate, 2 to 4 module, complete all as specified and as directed by Engineer-In-Charge.
M&L in replacment Modular metal boxes suitable for modular wiring, 2 to 4 module, complete all as specified and as directed by Engineer-In-Charge.
M&L for attending Breakdown Complaint of Bldng /No light / Fuse / any type of fault rectification with out repalcent of parts excluding sundry items complete all as specified and as directed by Engineer-In-Charge.
Supply only Insulation tape Roll of Size 20 MMx25 Mtr complete all as specified and as directed by Engineer-In-Charge.
SANJEEV ENTERPRISES
Ms Salaria Builders
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .