Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.7 L+₹1.6 L (6.19%)Rejected-Finance GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance NOT BEING A LOWEST BIDDER | |
| 3 | L3₹26.8 L+₹1.7 L (6.80%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance NOT BEING A LOWEST BIDDER | |
| 4 | L4₹26.9 L+₹1.8 L (7.23%)Rejected-Finance DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L4 | Rejected-Finance NOT BEING A LOWEST BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in the required category |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
2 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BRICHGUNJ
GE BRICHGUNJ PORT BLAIR - 744 103
REPAIR AND MAINTENANCE OF CERTAIN EXTERNAL ELECTRICAL SUPPLY WORKS UNDER GE BRICHGUNJ
2023_MES_624690_1
8400
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Brichgunj
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE BRICHGUNJ
₹50,000
Yes
1 Jan 2024
23 Oct 2023
4 Dec 2023
23 Oct 2023
2 Dec 2023
6 Nov 2023
Amount
Material and Labour for Jointing in repairs straight through compound joint, tapex joint, suitable for HT, XLPE cable with aluminium conductor of size 95 Sqmm, 11 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for Jointing in repairs straight through compound joint, tapex joint, suitable for HT, XLPE cable with aluminium conductor of size 95 Sqmm, 33 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for loose filling of 40 mm graded stone aggregates in plinths of out door transformer, sub stns, panel boards yard complete all as specified and as directed.
Filling fresh new EHV grade-II for topping up transformer oil duly filtered, ISI marked as per IS:335/93 with amdt. No.1 (Reaffirmed : 2005) dehydrated to give BDV value not less than 50 KV when tested with 2.5 mm gap electrode complete all as specified and as directed.
Supplying, laying, Jointing, testing and commissioning of HT UG cable, XLPE insulated, screened insulated, armoured and PVC bedded, 11 KV grade (heavy duty) suitable for earthed system with aluminium conductor of size 3 core 95 sqmm conforming to IS-7098 Part II laid in trenches, fixed to walls or passing through pipes and connecting up including taking out unserviceable cable complete all as specified and as directed. Note : Earth work excavation shall be measured and paid seperately under relevant item
Supplying , laying, Jointing, testing and commissioning of HT UG cable, XLPE insulated, screened insulated, armoured and PVC bedded, 33KV grade (heavy duty) suitable for earthed system with aluminium conductor of size 3 core 95 sqmm conforming to IS-7098 Part II laid in trenches, fixed to walls or passing through pipes, properly fixed with suitable cable glands and connecting up including taking out unserviceable cable complete all as specified and as directed.
Supply and fix in repairs terminal clamp along with bimettalic strip made up of aluminium along with bolts, nuts and washers suitable for ACSR Conductor to be fixed on 33 KV AB Switch all as directed and as specified.
Material and Labour for single phase potential transformer (PT's) conforming to IS-3156, Ratio:33kV/R3/110V/R3, Burden - 50VA, class of accuracy - 0.2, Frequency:50 Hz, Voltage factor: 1.2 continuous & 1.5 for 30 sec, Ins Level: 70kV/170kVp, INS class-A,Vk> 50V( core 1 & 4) Type of C, complete including first fill of transformer oil all as specified and as directed.
Material and Labour for 33 KV single phase current transformer (CT's) conforming to IS-2765, Ratio:50/1-1-1-1A, Burden - /15VA/15VA/-, class of accuracy - PS/0.5/5P-10 / PS, Frequency:50 Hz, INS level: 36/70/170 Kvp, STC:26kA for 15 sec, INS class-A,Vk> 50V (core 1 & 4) Type of C, complete including first fill of transformer oil all as specified and as directed. Make. Kappa or Pragati or Kalpa.
Supply and fix in replacement Copper Tube for bus bar of size min 20mm outer dia on 33 KV tower including bracing and jointing tube, connecting clamps and tightening the bus bars over the insulators including disconnecting the old copper tube bus bars all as specified and as directed. Note: Thickness of the bus bar shall be as per the sample or as decided by Engineer in Charge.
Supply & fix in repairs male /mooving contact / rotating blade of HDE copper silver plated of air brake off load isolator switch rotating type 33 KV, of 600 Amps capacity with all fixing nuts bolts etc. Make : Kurgg/Pactil / Jaipuria/BHEL all as specified and directed.
Supply & fix in repairs fixed female contact made of HDE copper silver plated of air brake off load isolator switch rotating type 33 KV, of 600 Amps capacity with all fixing nuts bolts etc all as specified and directed.
Supply and fix in replacement outdoor type 400 Amps nominal current rated, 33 KV, 3-phase, triple pole, double break, gang operated, centre rotating type Isolator with gang operated Earth switches, including Insulators and complete in all respects with arcing horns , bimetallic connectors, operating mechanism devices, fixing complete with GI operating pipe of heavy duty complete all as directed. Note: Rate is inclusive of following:- (a) Each pole unit of the multipole Isolators shall be of identical construction and mechanically linked for gang operation (b) All isolators as given in the schedule of requirements shall be suitable for horizontal upright mounting on structure (c) Moving contacts of all isolators shall rotate through 90 degree from their “Fully Closed Position” to “fully open position” so that the break is distinct and clearly visible from ground level. (d) Fixed guides shall be provided so that even when the blades are out of alignment by one inch (maximum) at the time of closing of switches, proper seating of the blades in between the contacts and adequate pressure to give enough contact surface are ensured, whenever possible, the blades shall be counter balanced by weights & springs at the end of the travel both on opening and closing of the isolator. The springs shall be made of durable and non-rusting type alloy. The isolator shall comply the following: i ) System frequency with + 3 % variation ( Hz) : 50 ii) Nominal system voltage (KV r.m.s.) : 33 iii) Maximum system voltage (KV r.m.s.)/ Rating Voltage : 36 iv) Maximum continuous current rating (Amps.) : 400 v) Rated short time current for 3 seconds (KA r.m.s) : 28.8 vi) Rated peak withstand current (KA peak) : 72 vii) 1.2/50 micro-sec lightning impulse withstand voltage (KV peak) a) To earth and between poles : 170 b) Across the isolating distance : 195 viii) Rated one minute power frequency withstand voltage ( KV r.m.s.) a) To earth and between poles : 70 b) Across the isolating distance : 80 ix) No. of poles : 3
Material and labour for 7Core 1.5sqmmcontrol cable for 33kv CT to existing control panel complete all as specified and as directed.
supply and fixing Lightning arresters for 33KV expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specoed and as directed.
Material and Labour for 33 KV Pin type insulator procelain vitreous white or Brown or green including galvanised mild steel straps all as specified and as directed.
Material and Labour for 33 KV Disc type insulator procelain vitreous white or Brown or green including galvanised mild steel straps all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed
Supply and lay HDPE double wall corrugated pipes and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 120mm and inner dia of 103.5mm polyethylene with smooth internal and profile external surface for non pressure under ground cable complete all as speciedd and as directed by Engineer-in-Charge.
Material and Labour for shifting of Transformer to main land/out side to work shop for repair , after disconnecting HV/LV connections of transformer upto 2000 KVA , shifting from any location from Brichgunj and connecting Hv/Lv side to provide power supply at other location as directed by Engineer in Charge.
BABBAR ENGINEERS
A. R. ELECTRICALS
PTech Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .