EE(E)
Nawab Yusuf Road BSNL CTO Building 2nd floor Allahabad UP
Repairing and replacement of existing faulty electrical distribution system in staff colony TE CTX Allahabad.
2023_BSNL_170856_1
02/EE(E)/BED-AD/2023-24
Open Tender
Electrical Works
Item Rate
15 days
Allahabad CTX TE Colony
Please refer Tender documents.
2 documents required · 2 mandatory
₹177
AO (Cash)O/o GM BSNL Allahabad BA
₹1,385
17 Nov 2023
14 Oct 2023
27 Oct 2023
14 Oct 2023
25 Oct 2023
14 Oct 2023
Amount
Disconnection,dismentalling and cutting of existing damaged PVC insulated PVC sheathed armoured Al. cable from wall and reconnection the both end of cable with suaitable size lug/ferrules by a peice of new cable i/c testinge tc complete as reqd
S/F of meter board of size approx 300 mmx 400mm made out of 6 mm thick bakelite sheet & 3 nos. 100 A kit-kat with 100 amp neutral link i/c connection with suaitable size lug /ferrules etc as required.(Kit Kat make Havells/HPL or SS make)
Supplying & fixing of 100 amp capacity, 4 way TP&N copper busbar in sheet steel enclosure, the copper bus bar strip fixed on suitable size DMC / Porcelain Insulator etc as required. (Make Havells/HPL/L&T or SS make)
Supplying and fixing of DP sheet enclosure on surface/recess alongwith 25/32 Amp 240 V "C" curve DPMCB i/c connection with suaitable size lug/ferrules, testing etc complete as required.
Supplying and fixing of 25/32 Amp DPMCB in the existing meter panel i/c connection,testing etc complete as required.
Supplying and fixing of 100 Amp 415 volt DIN type HRC fuse in existing SDFU of feeder piller and meter panel i/c connection,testing etc complete as required.
Disconnection,dismentalling and cutting of existing damaged PVC insulated PVC sheathed Al. cables in feeder piller and reconnection with suaitable sizes lug/ferrules i/c testing etc complete as required.
Supplying and fixing following way, SPN/TPN sheet steel, MCB distribution board, 240 V/415V on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door SPNDB
4 way , Double door TPNDB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole/four pole, 240 V/415V isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.
63 A SPN Isolator
63 A TPN Isolator
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .