Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹82.6 LAccepted-AOC PLOT NO 172 22 GALI NO 09 GANDHI NAGAR GURGAON 122001 | GURGAON | GURUGRAM | HARYANA | 122001 | ₹82.6 L | 1 | Accepted-AOC AOC |
| 2 | 2₹83.5 L+₹86,249 (1.04%)Rejected-Finance VILLAGE DUMERKHA KALAN POST OFFICE DUMERKHA KALAN TEHSIL UCHANA DISTRICT JIND 126115 HARYANA | DUMERKHA KALAN | JIND | HARYANA | 126115 | ₹83.5 L+₹86,249 (1.04%) | 2 | Rejected-Finance 2 |
| 3 | 3₹84.6 L+₹2.0 L (2.41%)Rejected-Finance B 85 1 NEAR SECTOR 4 BLOCK B SURYA VIHAR GURUGRAM HARYANA 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹84.6 L+₹2.0 L (2.41%) | 3 | Rejected-Finance 3 |
| 4 | 4₹85.8 L+₹3.2 L (3.85%)Rejected-Finance AMBALA CANTT | ₹85.8 L+₹3.2 L (3.85%) | 4 | Rejected-Finance 4 |
| 5 | 5₹97.4 L+₹14.8 L (17.9%)Rejected-Finance GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹97.4 L+₹14.8 L (17.9%) | 5 | Rejected-Finance 5 |
| Sl No | Description | Qty | Unit | Shanti Electrical Co. L3 | N D ELECTRICAL L5 | SANDEEP KUMAR CONTRACTOR L4 | DHEERAJ ENTERPRISES L2 | Fortune Enterprises L1 |
|---|---|---|---|---|---|---|---|---|
| 2.00Providing and fixing of 12.5 mtr High mast, 9 mtr Mini High mast, 8 mtr long GI pole in ward no-15 at Zone-1 under limit of Municipal Corporation Gurugram | ||||||||
| 3.00 | Supply and erection of 2.5 sqmm 3 core unard FRLS PVC insulated ISI Marked copper conductor cable complete as per entire satisfication of engineer in charge.Make RR / Havells / Polycab/Grandley. 2.5 Sq. mm 3 Core Cable. | 1,000 | Metre | 112 ₹1,12,000 | 65 ₹65,000 Lowest | 92 ₹92,000 | 110 ₹1,10,000 | 110 ₹1,10,000 |
| 4.00 | Providing trench less boring below existing road / pavement including laying of 65 mm dia GI pipe B class required to complete the job in all respect | 200 | Metre | 250 ₹50,000 | 600 ₹1,20,000 | 700 ₹1,40,000 | 50 ₹10,000 | 40 ₹8,000 Lowest |
| 5.00 | Restoring the road cut, in level with the existing road surface, including preparation of subgrade laying and relaying of soiling and laying and consolidation of wearing coats to water bound macadam specification and laying 20mm thick premix carpet, on top including cost of tack and sealcoat complete in all respects... | 250 | Sqm | 210 ₹52,500 | 200 ₹50,000 | 274 ₹68,500 | 50 ₹12,500 | 40 ₹10,000 Lowest |
| 6.00 | Providing trench less cuttting by Hydraulic Drilling Device boring/ Manual OR through some suitable alternate method with insertion of HDPE Pipe including supply, Delivery of HDPE pipe at work site and laying of 50mm internal diameter HDPE pipe inside road for road corssing of cable by Hydraulic Drilling Device without opening of the road top surface, laid at a depth of at least 900mm below the road surface from the feeding point to the feeder pillar box in median (OR) from feeder pillar to respective street light pole including cost of all accessories for road crossing for laying of cables.. | 350 | Metre | 150 ₹52,500 | 450 ₹1,57,500 | 320 ₹1,12,000 | 50 ₹17,500 | 45 ₹15,750 Lowest |
| 7.00 | Digging of pucca road in required width for laying of cable/pipe complete in all respect upto the entire satisfaction of Engineer-in-charge.. | 100 | cum | 80 ₹8,000 | 200 ₹20,000 | 224 ₹22,400 | 50 ₹5,000 | 40 ₹4,000 Lowest |
| 8.00 | Supply and Erection of Timer Contractor, DP, MCB mounted on Bakelite sheet and Installed in water proof CRCA Sheet 18 SWG duly painted with powder coated paint Box of Size 12``x15``x5`` duly lockable including Input and Out Put Connectors Bakelite/Porclein of 63A Rating and neccessary service cable up to 10 mtr complete with internal copper wiring and installing the same on pole/pedestal with suitable means at height desired by Engineer in charge to aviod theft upto entire satisfication of engineer incharge with following specification. Timer :-Quartz Analog 24 Hour Operation (G.E/LandT/Siemens/Indoasian/CandS) Contractor :- 3Pole 32A, 415Volt. (Schnider/LandT/Siemens/Indoasian/CandS) DPMCB :- 40A 2pole. (G.E/LandT/Siemens/Schnider/CandS).. | 15 | Each | 7,500 ₹1,12,500 | 15,000 ₹2,25,000 | 6,150 ₹92,250 Lowest | 7,500 ₹1,12,500 | 7,500 ₹1,12,500 |
| 9.00 | Erection Testing and commissioning of Three phase CCMS panel petty material required for installation of ccms panel i.e clamp,nut and bolts,thimble ,wire etc complete in all material required for installation on PCC pole or Pedstal. complete in all material required for installation on PCC pole or Pedstal. | 4 | Each | 2,000 ₹8,000 | 5,000 ₹20,000 | 1,640 ₹6,560 Lowest | 2,000 ₹8,000 | 2,000 ₹8,000 |
| 10.00 | Providing and fixing of 4G/5G Sim Card and recharse fees per month for street lights CCMS panel Compelte in all respect required for proper operation of CCMS panel. 500 Nos x 60 | 192 | Each | 77 ₹14,784 | 2,000 ₹3,84,000 | 63 ₹12,096 Lowest | 77 ₹14,784 | 77 ₹14,784 |
| 11.00 | Supply and eraction of 9 meter long high mast IS, 2062 E250A single saction 3mm thick sheet GI sheet, top dia 150mm bottom dia 360mm hot dip galvanized thickness of galvanized 70 micron as per IS 2629 opening door at base 900x305mm closed, fitting, door with ALLEN KEY thickness and diameter of base plate 25 mm, 520mm, (O.D) IS 2062 E250A size of anchor plate and thickness 3 mm with uniform PCD of 460mm (IS 2062 E250A, no of arm 6nos. double drum type, permanent oil bath lubrication arrangment, 500kg loading capacity still core , 3 plus 2 nos. ropes , braking capicity load 1750 kg for core PVC insulatted 2.5 squre mm coper wire with 6nos foundation bolts length 850mm dia meter 24mm input supply 3 phase 415 balts and motor required as per capicity and Supply and erection of RCC foundation 1.5.3 of size 0.7 M x 0.7M × 1.8 M with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8mm dia not more than 200 mm C.C. for fixing the High Mast with all labour and material required of complete in all respect ( design of high mast, bracket, light fiting as per attached drawing ) | 12 | Each | 1,30,692 ₹15,68,304 | 35,000 ₹4,20,000 Lowest | 1,13,000 ₹13,56,000 | 1,24,500 ₹14,94,000 | 1,24,000 ₹14,88,000 |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
22 May 2026, 12:00 pmClosed
SACHIN YADAV
Municipal Corporation Gurugram
Providing and fixing of 12.5 mtr High mast, 9 mtr Mini High mast, 8 mtr long GI pole in ward no-15 at Zone-1 under limit of Municipal Corporation Gurugram.
2026_HRY_520727_1
20261052BED9 26EF 4627 8582 D7857EF15D72285ULB
Open Tender
Civil Works
Works
150 days
Gurugram
Providing and fixing of 12.5 mtr High mast, 9 mtr Mini High mast, 8 mtr long GI pole in ward no-15 at Zone-1 under limit of Municipal Corporation Gurugram.
2 documents required · 2 mandatory
₹15,180
Yes
₹2.1 L
Yes
29 Jul 2026
11 May 2026
22 May 2026
11 May 2026
22 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Providing and fixing of 12.5 mtr High mast, 9 mtr Mini High mast, 8 mtr long GI pole in ward no-15 at Zone-1 under limit of Municipal Corporation Gurugram | - | - | - | - |
| 3 | Supply and erection of 2.5 sqmm 3 core unard FRLS PVC insulated ISI Marked copper conductor cable complete as per entire satisfication of engineer in charge.Make RR / Havells / Polycab/Grandley. 2.5 Sq. mm 3 Core Cable. | 1,000 | Metre | - | - |
| 4 | Providing trench less boring below existing road / pavement including laying of 65 mm dia GI pipe B class required to complete the job in all respect | 200 | Metre | - | - |
| 5 | Restoring the road cut, in level with the existing road surface, including preparation of subgrade laying and relaying of soiling and laying and consolidation of wearing coats to water bound macadam specification and laying 20mm thick premix carpet, on top including cost of tack and sealcoat complete in all respects... | 250 | Sqm | - | - |
| 6 | Providing trench less cuttting by Hydraulic Drilling Device boring/ Manual OR through some suitable alternate method with insertion of HDPE Pipe including supply, Delivery of HDPE pipe at work site and laying of 50mm internal diameter HDPE pipe inside road for road corssing of cable by Hydraulic Drilling Device without opening of the road top surface, laid at a depth of at least 900mm below the road surface from the feeding point to the feeder pillar box in median (OR) from feeder pillar to respective street light pole including cost of all accessories for road crossing for laying of cables.. | 350 | Metre | - | - |
| 7 | Digging of pucca road in required width for laying of cable/pipe complete in all respect upto the entire satisfaction of Engineer-in-charge.. | 100 | cum | - | - |
| 8 | Supply and Erection of Timer Contractor, DP, MCB mounted on Bakelite sheet and Installed in water proof CRCA Sheet 18 SWG duly painted with powder coated paint Box of Size 12``x15``x5`` duly lockable including Input and Out Put Connectors Bakelite/Porclein of 63A Rating and neccessary service cable up to 10 mtr complete with internal copper wiring and installing the same on pole/pedestal with suitable means at height desired by Engineer in charge to aviod theft upto entire satisfication of engineer incharge with following specification. Timer :-Quartz Analog 24 Hour Operation (G.E/LandT/Siemens/Indoasian/CandS) Contractor :- 3Pole 32A, 415Volt. (Schnider/LandT/Siemens/Indoasian/CandS) DPMCB :- 40A 2pole. (G.E/LandT/Siemens/Schnider/CandS).. | 15 | Each | - | - |
| 9 | Erection Testing and commissioning of Three phase CCMS panel petty material required for installation of ccms panel i.e clamp,nut and bolts,thimble ,wire etc complete in all material required for installation on PCC pole or Pedstal. complete in all material required for installation on PCC pole or Pedstal. | 4 | Each | - | - |
| 10 | Providing and fixing of 4G/5G Sim Card and recharse fees per month for street lights CCMS panel Compelte in all respect required for proper operation of CCMS panel. 500 Nos x 60 | 192 | Each | - | - |
| 11 | Supply and eraction of 9 meter long high mast IS, 2062 E250A single saction 3mm thick sheet GI sheet, top dia 150mm bottom dia 360mm hot dip galvanized thickness of galvanized 70 micron as per IS 2629 opening door at base 900x305mm closed, fitting, door with ALLEN KEY thickness and diameter of base plate 25 mm, 520mm, (O.D) IS 2062 E250A size of anchor plate and thickness 3 mm with uniform PCD of 460mm (IS 2062 E250A, no of arm 6nos. double drum type, permanent oil bath lubrication arrangment, 500kg loading capacity still core , 3 plus 2 nos. ropes , braking capicity load 1750 kg for core PVC insulatted 2.5 squre mm coper wire with 6nos foundation bolts length 850mm dia meter 24mm input supply 3 phase 415 balts and motor required as per capicity and Supply and erection of RCC foundation 1.5.3 of size 0.7 M x 0.7M × 1.8 M with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8mm dia not more than 200 mm C.C. for fixing the High Mast with all labour and material required of complete in all respect ( design of high mast, bracket, light fiting as per attached drawing ) | 12 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
BOQ_599623.xls
BOQ • 0.28 MB
AD0162926.pdf
Additional Documents • 0.97 MB
OT0162926.pdf
Other Document • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .