Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹1.1 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹1.2 Cr+₹12.0 L (11.0%)Rejected-Finance 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹1.2 Cr+₹12.0 L (11.0%) | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | L3₹1.2 Cr+₹14.1 L (12.9%)Rejected-Finance | ₹1.2 Cr+₹14.1 L (12.9%) | L3 | Rejected-Finance Being other than lowest tenderer |
| 4 | L4₹1.2 Cr+₹15.7 L (14.4%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹1.2 Cr+₹15.7 L (14.4%) | L4 | Rejected-Finance Being other than lowest tenderer |
| 5 | L5₹1.3 Cr+₹19.8 L (18.1%)Rejected-Finance | ₹1.3 Cr+₹19.8 L (18.1%) | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
10 Aug 2021, 6:00 pmClosed
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
87638E8 ADDITION / ALTERATION TO BLDG NO.60, 61 AND 66 AF STN UNDER GE AVADI CHENNAI
2021_MES_455649_1
87638E8
Open Tender
Civil Works
Item Rate
180 days
AVADI CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AVADI CHENNAI
₹2.0 L
Yes
22 Oct 2021
29 Jun 2021
12 Aug 2021
29 Jun 2021
10 Aug 2021
29 Jul 2021
29 Jun 2021 - 6 Jul 2021
Amount
REVISED BOQ UPLOADED ON 24 JUL 2021, BOQ UPLOADED ON 29 JUN 2021 CANCELLED
SCH "A" PART-I (CIVIL WORKS)
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, etc including cleaning for refixing or removal to store (measured overall as fixed along centre line over fittings and accessories) and taken on credit complete all as specified and as directed.
Taking down cement plaster any description on brick or stone walls, concrete surfaces, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Dismantling existing water tanks, exceeding 250 litres and not exceeding 500 litres, and taken on credit complete all as specified and as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removal of unserviceable debris outside of MD land complete all as specified and as directed.
Demolition of stone slabs / tiles of any description or thickness in floors or vertical surfaces, as in ceramic tiles laid, bedded and pointed in any mortar including bedding screed and backing in vertical surfaces and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Dismantling of stone slabs / tiles of any description or thickness in floors or vertical surfaces, laid, bedded and pointed in any mortar including bedding screed and backing in vertical surfaces and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 150mm thickness (below or above ground level) and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of unserviceable debris to outside of MD land complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and taken on credit complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets and kept aside for refixing after repairing damage complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
Spreading and levelling sand below interlocking paver block paving as cushioning, complete all as specified and as directed.
Excavating over areas, not exceeding 1.5 m deep and getting out in any type of soil complete all as specified and as directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Moorum/red bajri filling as in berms, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
The cubical measurement shall be after consolidation.
Hardcore of gauge not exceeding 63mm of broken stone aggregate, deposited, spread and levelled in layers not exceeding 150mm thick, watered and rammed to a true surface complete all as specified and as directed.
Plain cement concrete, type D2, 1:4:8, using 40mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
Plain cement concrete, type B1, 1:2:4, using 20mm graded stone aggregate as in bed blocks, coping and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed.
Pre-cast reinforced cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in cover slabs with plain fair faces, including chamfers, weatherings, throating etc., and setting in cement mortar (1:6) complete with joints to match complete all as specified and as directed.
Notes:-
(a) The rate is inclusive of finishing the exposed surfaces as per clause 4.11.16 of MES Schedule Part-I.
(b) Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, shelves and the like complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Brickwork with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, shelves and similar work not exceeding 200mm thick (horizontal or sloping) rough finished surfaces of concrete complete all as specified and as directed.
Butt hinges, medium weight, cold rolled mild steel and fixed / welded to frame of size 100mm complete all as specified and as directed.
Ordinary rat tail rod pattern springs, 300mm, mild steel, including roller and roller plate complete all as specified and as directed.
Extruded aluminium alloy handles, fabricated type, anodised of size 150mm complete all as specified and as directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 150mm, including fixing on floor complete all as specified and as directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Aluminium frame for doors, sliding windows, ventilators with one or more rebates including joining cleat for fixing etc. powder coated to minimum 50 micron thickness complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet as in roof covering / cladding to wall, fixed with self tapping screws but except sheeting (any thickness) complete all as specified and as directed.
The serviceable steel sheeting obtained from BOQ item No 11.00 shall be reused in this item.
Mild steel sheet 1.25mm thick, eaves gutters, galvanised class 3, half round of dia 150mm, with rounded edges complete all as specified and as directed.
Prelaminated particle board minimum 9mm thick, exterior grade, one side prelaminated with decorative choice lamination and other side balancing white fixed with screws to timber framework complete all as specified and as directed.
Machine cut, polished, kota stone slab flooring, 18-20mm thick laid over cement screed base in CM 1:4, 20mm thick, laid and jointed with grey cement slurry at the rate of 4 kg per SQUARE METRE, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
BLANK
Plain cement concrete, 1:5:10, type E2, using 40mm graded stone aggregate, 100mm thick as in sub-base complete all as specified and as directed.
Plain cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate, 100mm thick as in hardstanding complete all as specified and as directed.
Wear proof topping 20mm thick (incorporating an approved metallic floor hardener), laid on concrete floors and pavings, and finished even and smooth (except metallic hardener) complete all as specified and as directed.
Metallic hardener as required shall be measured and paid separately as supplied only.
Supply only of metallic hardener to be incorporated in wear proof topping complete all as specified and as directed and as per manufacturer's instructions.
Granite (of any type) work, of thickness 22mm to 25mm, (table rubbed and polished) in wash basin platforms, cooking platforms, steps, jambs, pillars, windows and the like set in cement mortar 1:4, 20mm thick, including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stone complete all as specified and as directed.
Non-skid ceramic coloured tiles (matt finish), minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 square metre but not exceeding 0.11 square metre, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B1 quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / square metre complete all as specified and as directed.
Vitrified ceramic coloured tiles, light shade, 10mm thick (square / rectangular) polished, area of each tile exceeding 0.36 square metre but not exceeding 0.42 square metre in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / square metre complete all as specified and as directed.
Vitrified ceramic coloured tiles, light shade, 10mm thick (square / rectangular) polished, area of each tile exceeding 0.36 square metre but not exceeding 0.42 square metre in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed.
Glazed ceramic tiles coloured of size 350mm x 250mm / 450mm x 350mm / 300 x 450mm minimum 7mm thick in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as specified and as directed.
Rendering 10mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Forming V grooves in plaster not exceeding 10mm deep and not exceeding 10mm on face complete all as specified and as directed.
Preparing newly plastered surfaces of wall and applying two coats of colour wash over a coat of white wash including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Frosted sheet glass, 5.5mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 square metre in each pane complete all as specified and as directed.
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) , three layered hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres complete all as specified and as directed.
Plain cement concrete 1:4:8, type D2, using 40mm grade stone aggregate including necessary formwork as in concrete bed to RCC drain pipes including packing under, and completely surrounding pipes with concrete after securing the joints with suitable RCC collar for bore of pipe of 300mm after they are laid and tested all as specified and as directed.
Reinforced concrete pipes, class NP2, laid and jointed complete with collars of bore of pipe 300mm laid in trenches complete all as specified and as directed.
Earthwork and concrete bed as required shall be measured and paid for under relevant items of this schedule.
Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with "P" or "S" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed as in repairs complete all as specified and as directed.
(a) Flushing cistern, flush pipe, seat cover as required shall be measured and paid for under supply only separately.
(b) Supply pipes as required shall be measured and paid for separately.
Supply only PVC valveless, syphonic action type flushing cistern 10 litres capacity low level, white with inlet, ball valve, float and handle / push button, including brackets complete all as specified and as directed.
Supply only flush pipe of polyethylene of high density, 32mm dia for low level / high level flushing cistern complete all as specified and as directed.
Supply only of plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
Vitreous china urinal, half stall type, white (excluding waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and union for discharge pipe fixed as in repairs complete all as specified and as directed.
(a) Flushing cistern, flush pipe, waste fitting as required shall be measured and paid for under supply only separately.
(b) Supply and waste pipes as required shall be measured and paid for separately.
Supply only waste coupling of PTMT (half or full threaded) suitable for urinals fixed of bore of pipe 32mm (Minimum weight 32mm-45gms) complete all as specified and as directed.
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified and as directed.
Vitreous china wash basin, white, flat back, size 550mm x 400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets and including fixing of the following components viz. pillar taps, waste fittings and union, plugs and chains and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidary materials required for fixing including cutting for and pinning in ends of brackets but exclusive of fixing of supply and waste pipe as in repairs complete all as specified and as directed.
(a) Pillar taps and waste fittings as required shall be measured and paid for under supply only separately.
(b) Supply and waste pipes as required shall be measured and paid for separately.
Vitreous china wash basin, white, flat back, size 550mm x 400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets and including fixing of the following components viz. pillar taps, waste fittings and union, plugs and chains and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidary materials required for fixing including cutting for and pinning in ends of brackets but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
(a) Pillar taps and waste fittings as required shall be measured and paid for under supply only separately.
(b) Supply and waste pipes as required shall be measured and paid for separately.
Supply only pillar taps, swan neck with flange, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of bore of pipe 15mm complete all as specified and as directed.
Supply only waste coupling of PTMT (half or full threaded) fixed of bore of pipe 32mm (Minimum weight 32mm-45gms) complete all as specified and as directed.
Supply only waste coupling of PTMT (half or full threaded) fixed of bore of pipe 32mm (Minimum weight 32mm-45gms) as in repairs complete all as specified and as directed.
Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed of bore of pipe 15mm (Minimum weight 15mm-90gms) complete all as specified and as directed.
Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed of bore of pipe 15mm (Minimum weight 15mm-90gms) as in repairs complete all as specified and as directed.
Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and as directed.
PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
LDPE pipes, 32mm bore of pipe, of pressure rating 6 kgf/sqcm with polyethylene thread union and check nuts, fixed to walls as in waste pipe complete all as specified and as directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 75mm complete all as specified and as directed.
Earthwork as required shall be measured and paid for separately.
CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors outer diameter 20mm complete all as specified and as directed.
Removing old unserviceable insulation under Sch of Credit and providing underdeck insulation for galvalume roof with bonded fibre glass wool of density 48 Kg/Cum, 75 mm thick, suitably factory laminated with aluminium foil having flange on one side, backed up by scrim and kraft paper, comprising of the following (insulating material shall conform to BS - 476, Part 4,5, 6 & 7) complete all as specified and as directed.
(a) Slotted angles 50mm x 50mm or 75mm x 75mm, 50mm wide, fixed to roof purlins / rafters / truss work by means of suitable "J" bolts at 600 mm centre to centre.
(b) -BLANK-
(c) Aluminium foil, adhesive tape 50 mm for sealing of aluminium foil flanges.
(d) Providing additional support to the insulation with and including hard drawn steel wire fabric not exceeding 4 kg / sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm and fixed to wooden frame or steel members.
Seamless calcium silicate ceiling made out of 1800mm x 1200mm x 8mm thick size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specified and as directed.
Frame work for ceiling shall be measured and paid separately.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approximately 900mm centre to centre with Gl cleat and "J" bolts with and including ceiling section (not exceeding 1.20m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.
Preparing new surfaces of calcium silicate as in false ceiling of any description over 10cm girth or width, not otherwise described and applying one coats of plastic emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Dismantling existing industrial roof vent and Fabrication, supply and installation of high performance industrial roof vent of neck dia 600mm of aluminium alloy designed to meet ASS - 2428 dated 28 Jan 1993 to withstand wind speed of 200 km / hr and to entry of wind driven rain at the range of 2.5 litres per second inclusive of base plate and accessories complete all as specified and as directed.
Preparing of damaged concrete surface by removing spalled concrete and damaged plaster, cleaning the surface, applying epoxy bonding agent and rendering the concrete surface with fibre reinforced, shrinkage controlled, cementitious repair mortar prepared by adding and mixing 25 kg of dry powder with 4 litres of water (or as recommended by the manufacturer) in plastic container of suitable size using paddle mixer for 3 to 5 minutes to attain a trowellable consistency complete all as specified and as directed.
(a) The bonding agent and cementitious mortar shall of brands Nitobond EP and Renderoc HS Xtra respectively of Fosroc firm or equivalent of makes listed here-in-after.
(b) The rate quoted is deemed to include all ancillary materials and tools required to carryout the work as per manufacturers instructions.
Preparing existing concrete surface / newly laid concrete surface and laying epoxy polyurethane flooring (EPU flooring) consisting of epoxy resin primer followed by epoxy underlayer of 2mm thick epoxy resin primer followed by epoxy self levelling layer of 2mm thick followed by polyurethane wear course of 75 microns complete all as specified and as directed.
(a) Make shall be as under or equivalent of makes as listed here-in-after.
(i) Epoxy resin primer of Fosroc Brand Name Nitoprime 25
(ii) Epoxy under layer of Fosroc Brand Name Nitoflor EU5
(iii) Epoxy self levelling layer of Fosroc Brand Name Nitoflor SL2000
(iv) Epoxy wear course of Fosroc Brand Name Trafficguard UL100
For all other mandatory requirements of EPU flooring, please refer under Particular Specifications here-in-after.
Preparing existing concrete surface / newly laid concrete surface and providing epoxy coving of size 75mm x 75mm consisting of epoxy priming coat, followed by three part epoxy mix followed by epoxy putty to bring to a smooth finish, finished by high build epoxy paint of approved shade complete all as specified and as directed.
(a) Make shall be as under or equivalent of makes as listed here-in-after.
(i) Epoxy resin primer of Fosroc Brand Name Nitoprime 25
(ii) Epoxy coving mortar of Fosroc Brand Name Nitoflor TF5000
(iii) Epoxy putty of Fosroc Brand Name Nitocote VF
(iv) High build epoxy paint of Fosroc Brand Name Nitoflor FC 150
For all other mandatory requirements of epoxy coving, please refer under Particular Specifications here-in-after.
BLANK
SCH "A" PART-II (INTERNAL ELECTRIFICATION)
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fitting etc., and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
Taking down carefully unserviceable sub main wiring aluminium conductor cables any number of runs of any cross section complete, including removal of batten / conduit and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
Taking out existing service cable any type of cross section upto 25 sqmm from wall / steel trusses connected to loadline DB and taken on credit complete all as specified and as directed.
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed FRLSH cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.89 here-in-before but for one ceiling fan point controlled by one switch and regulator
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.89 here-in-before but for one wall mounted fan point controlled by one switch.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.89 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.89 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.89 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor FRLSH green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.89 here-in-before but for point wiring with two 2.5 sqmm single core copper conductor multistranded FRLSH cable and one 2.50 sqmm PVC insulated single core multistranded cable as earth continuity conductor FRLSH green in colour for one heavy duty air circulator fan point controlled by one switch complete all as specified and as directed.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
Switch piano, flush type single pole, one way, 5 Amps complete all as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type complete all as specified and as directed.
Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed.
Stepped type electronic fan regulator, 300 W, flush type, including fixing on existing laminated sheet complete as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws complete all as specified and as directed.
Taking down existing light fitting and provision of Surface and wall mounted indoor decorative aluminium extruded T5 LED battens integrated type, 20 W, suitable to operate on AC 220 V / 230 V, 50 Hz supply, prd wired including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire complete all as specified and as directed.
(a) Make shall be C & S Cat No. NAKSHATRA/20W or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Taking down existing light fitting and provision ofRecess mounting powder coated white CRCA full glow backlit LED panel light 30 watt (2' x2') with integrated electronic driver suitable to operate on AC 220 V / 230 V, 50 Hz supply, pre wired including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire complete all as specified and as directed.
(a) Make shall be C & S Cat No. CYGNUS-C/30W/2X2/W or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Taking down existing light fitting and provision of Integral industrial SMD LED highbay fitting, 200 watt, IP-65 with pressure die-cast aluminium housing with integrated polycarbonate cover, with all accessories and integrated electronic driver suitable to operate on AC 220 V / 230 V, 50 Hz supply, pre wired including connecting up with suitable size cable complete all as specified and as directed.
(a) Make shall be C & S Cat No. CORVUS-E/200W or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Taking down existing light fitting and provision of SMD LED flood light 100 watt, IP-65 with pressure die-cast aluminium housing luminaire in single piece deep drawn housing with all accessories and glass cover with suitable bracket or with grouted spring pressure fastener / steel rawl plugs pre wired including connecting up with FRLSH PVC sheathed 2.5 sqmm 2 single core copper conductor flexible wire drawn through suitable flexible conduit complete all as specified and as directed.
(a) Make shall be C & S Cat No. GLOFLO/100W or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Taking down ceiling fan any sweep, dismantling and opening up, replacing bearings, bushes, condensors of same existing type and capacity, greasing, assembling back, painting of fans complete, with synthetic enamel paint by spraying including filling cavities with filler, coat after cleaning all dust, dirt, grease, rewinding motor etc., testing and writing MES No.20mm height with synthetic enamel paint black and hanging back in position with all accessories and connecting including 1.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing complete all as specified and as directed.
Taking down ceiling fan any sweep, dismantling and opening up, replacing bearings, bushes, condensors of same existing type and capacity, greasing, assembling back, painting of fans complete, with synthetic enamel paint by spraying including filling cavities with filler, coat after cleaning all dust, dirt, grease etc., testing and writing MES No.20mm height with synthetic enamel paint black and hanging back in position with all accessories and connecting including 1.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing complete all as specified and as directed.
Ceiling fan 1200mm sweep, without regulator, high speed, 3 star rating fan, with suitable down rod, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
Make shall be of Usha Cat No.TECHNIX PLUS 3 STAR or equivalent of makes as listed here-in-after.
Taking down air circulator any sweep, dismantling and opening up, replacing bearings, bushes, condensors of same existing type and capacity, greasing, assembling back, painting of fans complete, with synthetic enamel paint by spraying including filling cavities with filler, coat after cleaning all dust, dirt, grease, rewinding motor etc., testing and writing MES No.20mm height with synthetic enamel paint black and hanging back in position with all accessories and connecting including 1.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing complete all as specified and as directed.
Taking down air circulator any sweep, dismantling and opening up, replacing bearings, bushes, condensors of same existing type and capacity, greasing, assembling back, painting of fans complete, with synthetic enamel paint by spraying including filling cavities with filler, coat after cleaning all dust, dirt, grease etc., testing and writing MES No.20mm height with synthetic enamel paint black and hanging back in position with all accessories and connecting including 1.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing complete all as specified and as directed.
Air circulators metal heavy duty 600mm sweep, AC single phase, 240 Volts, 50 Hz including nuts and bolts and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
Make shall be of Usha Cat No. DOMINAIRE WALL FAN or equivalent of makes as listed here-in-after.
Wall fan 400mm sweep, AC single phase, 240 Volts, 50 Hz including nuts and bolts and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
Make shall be of Usha Cat No. MAXX AIR or equivalent of makes as listed here-in-after.
Taking down MCB DB including inner components and provision of MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, with 200 Amps rated bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
Taking down MCB DB including inner components and provision of Load line MCB DB TPN 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for MCCB TP, 125 / 160 Amps as incomer and MCB SP 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, blanking plates,earth link and connecting up complete all as specified and as directed.
(a) Make shall be as Havells Cat No. DHDLVDRWGOFO04 under or equivalent of makes as listed here-in-after.
(b) MCCB and MCB as required shall be measured and paid separately.
MCB 6-40 Amps, SP, 240 Volts, 50 Hz, AC supply, "B" curve, with breaking capacity of 10 kA complete all as specified and as directed.
(a) Make shall be Havells Cat No. DHMGBSPF006-032 or equivalent of makes as listed here-in-after.
MCB 40 Amps, SPN, 240 Volts, 50 Hz, AC supply, "C" curve with breaking capacity of 10 kA complete all as specified and as directed.
(a) Make shall be Havells Cat No. DHMGCSNF40 or equivalent of makes as listed here-in-after.
MCB 63 Amps, TP, 415 Volts, 50 Hz, AC supply, "C" curve with breaking capacity of 10 kA complete all as specified and as directed.
(a) Make shall be Havells Cat No. DHMGCTPF63 or equivalent of makes as listed here-in-after.
Sheet metal enclosures with socket plug top and MCBs, triple pole and earth with three pin and earth plug and socket complete one triple pole MCB 63 Amps, 10 kA, "C" Curve, 240 V as in repairs complete all as specified and as directed.
(a) Make of enclosure shall be Havells Cat No. DHDPUTN020 / DHDPUTN030 and MCB shall be Havells Cat No. DHMGCTPF063 or equivalent of makes as listed here-in-after.
MCCB 125 Amps, TP, 415 Volts, 3 phase, 50 Hz, 16 kA breaking capacity, with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLGNT125 or equivalent of makes as listed here-in-after.
MCCB 160 Amps, TP, 415 Volts, 3 phase, 50 Hz, 16 kA breaking capacity, with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLGNT160 or equivalent of makes as listed here-in-after.
MCCB 100 Amps, FP, 415 Volts, 3 phase, 50 Hz, 25 kA breaking capacity, with adjustable thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLASF0100 or equivalent of makes as listed here-in-after.
MCCB 200 Amps, FP, 415 Volts, 3 phase, 50 Hz, 25 kA breaking capacity, with adjustable thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLASF0200 or equivalent of makes as listed here-in-after.
Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm FRLSH conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable FRLSH (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
(a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length.
(b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmm FRLSH conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith two runs of 10 sqmm PVC insulated single core multistranded copper conductor cable FRLSH (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
(a) Four runs of 10 sqmm cable and two runs of 10 sqmm cable and one run of conduit will be measured as one length.
(b) Cutting chases on walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, fixed on walls / steel trusses of the following sizes complete all as specified and as directed.
Lugs and glands shall be used appropriately wherever required while connecting cables and the quoted rates are deemed be include for the same.
(a) 4 core, cross sectional area 16 sqmm.
(b) 4 core, cross sectional area 25 sqmm.
Earthing complete with copper earth plate electrode 600mm X 600mm X minimum 3mm thick, with and including earthing of copper strip 20mm x 3mm protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Taking out existing earthing materials and provision of Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Earth continuity conductor or main earthing lead of 20mmx 3mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as in repairs complete all as specified and as directed.
Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as in repairs complete all as specified and as directed.
SCH "A" PART-III (AIR CONDITIONING)
Supply, install, testing and commissioning of split AC, wall mounted hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2,0 TR complete all as specified and as directed.
The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units.
Supply, install, testing and commissioning of split AC, wall mounted hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and as directed.
The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units.
Supply, fix, testing and commissioning of automatic boost / buck transformer for low and high voltage correction, capacity of 5 kVA, complete with voltmeter and designed for an input voltage of 170 Volts to 250 Volts and a stabilised output voltage of 230 Volts with accuracy of + 2.5 % suitable to operate under 50 Hz, single phase air cooled wall mounting type complete all as specified and as directed.
The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units.
Supply, fix, testing and commissioning of automatic boost / buck transformer for low and high voltage correction, capacity of 4 kVA, complete with voltmeter and designed for an input voltage of 170 Volts to 250 Volts and a stabilised output voltage of 230 Volts with accuracy of + 2.5 % suitable to operate under 50 Hz, single phase air cooled wall mounting type complete all as specified and as directed.
The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units.
Supply, install, testing and commissioning of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 10-12 m/sec air velocity at floor level for door opening of size 52" x 78" specified. complete all as specified and as directed.
The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units.
Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, "C" Curve, 240 V complete all as specified and as directed.
(a) Make of enclosure shall be Havells Cat No. DHDPUSN020 / DHDPUDP020 and MCB shall be Havells Cat No. DHMGCSPF006-032 or equivalent of makes as listed here-in-after.
Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 25, 10 kA, "C" Curve, 240 V complete all as specified and as directed.
(a) Make of enclosure shall be Havells Cat No. DHDPUSN020 / DHDPUDP020 and MCB shall be Havells Cat No. DHMGCSPF006-032 or equivalent of makes as listed here-in-after.
pmv.enterprises
M/s Omm Muruga Enterprises
BKR Enterprises
HARI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .