| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.6 L+₹27,410 (5.15%)Rejected-Finance CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹5.8 L+₹50,625 (9.52%)Rejected-Finance NOT FOUND | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹5.9 L+₹60,814 (11.4%)Rejected-Finance GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹5.6 L
EMD Value
₹11,300
Closing Date
16 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Sirsa
Military Engineer Services, Garrison Engineer (AF) Sirsa-125055
Addn/Altn to GCA Complex with allied works at AF Stn Sirsa
2023_MES_575500_1
GE/SRA/T-55/2022-23
Open Tender
Miscellaneous Works
Item Rate
150 days
GE (AF) Sirsa
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Sirsa
₹11,300
Yes
2 Mar 2023
17 Jan 2023
18 Feb 2023
17 Jan 2023
16 Feb 2023
31 Jan 2023
18 Jan 2023 - 25 Jan 2023
Amount
SCHEDULE 'A' PART-I (B/R WORKS) M&L Brick Work with fly ash bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only"
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
M&L preparing New Plastered Surfaces of Walls and applying Two Coats of Weather Coat Exterior emulsion Paint (in Camouflage/Plain pattern as ordered) with approved Tint over a coat of Primer (as per Manufacturer's instructions), complete all as specified and as directed.
M&L for Reinforced cement concrete (nominal mix) M-20 in Type B1 1:2:4 (20 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified.
M&L for Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for stirrups, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified.
M&L for Cement concrete 1:4:8 type D2 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F PVC (SWR) pipes, type 'A', single socketed in any length with rubber ring joints of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc, complete all as specified and as directed.
S&F Anodised Powder Coated (minimum thickness of Powder Coating is 50 micron) Aluminium Frame for Doors, Windows, Ventilators with one or more Rebates including Jointing Cleat for fixing etc.complete all as specified and as directed.
S&F Anodised aluminium door shutters powder coated (Thickness or powder coating not less than 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
M&L for ceramic Floor (paver) tiles 400x400x9.0 to 10mm, highly abrasive, anti-skid, impact resistance, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and as directed. Note : Cost of cement screed bed shall deem to be included in the quoted unit rate.
M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces not exc. 10 cm width or girth including preparation of surfaces complete all as specified and as directed.
S&F 5.5 mm thick plain sheet glass for Aluminium door/partition/ window complete all as specified and as directed.
SCHEDULE 'A' PART-II (E/M WORKS) Taking down Copper/Aluminium Point wiring any type in PVC casing caping/PVC Conduit (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any description and making good disturbed surfaces of walls, floors, etc so as to match with the existing finishes, complete all as specified and as directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly,.complete all as specified and directed. for one light point / bell point/ceiling fan/exhaust fan point controlled by one way switch. NOTE :- (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Point wiring shall be measured from switch board/DB to outlets only. Main circuit wire of the switch board/DB shall be measured and paid seperately as sub main wiring of required size depending upon the load of that switch board. (iii) Quoted rate shall be exclusive of the cost of terminal box and laminate cover which shall be measured seperately.
-do- all as per Item No. 21 here in before but for 6 Amps Socket Outlet on Independent board, complete all as specified and as directed.
-do- all as per Item No. 21 here in before but for 6 Amps Socket Outlet on same board, complete all as specified and as directed.
-do- as per item No 21 above but using 4.0 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 4.0 Sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
Taking down/out unserviceable wires only from the existing sub-main wiring of any type and any description without disturbing existing conduit, complete all as specified and as directed.
M&L for sub main wiring with 2 runs of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC conduit of suitable size complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring with 2 runs of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC conduit of suitable size complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit)
S&F Modular switch 1 way 6 Amp, 1 module, complete all as specified and as directed.
S&F Modular switch 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F Modular socket outlet 6 & 16 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular socket outlet 6 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular bell push button 6 Amp, 1 modular suitable for Call Bell and complete all as specified and as directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Call Bell Electric Single Pole 230 Volt, AC supply, ding dong type and complete all as specified and as directed.
S&F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
Taking down existing/serviceable fan, sealing cable end, dismantling blades and removing fan and blades and painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, oiling work, repair completely to serviceable and hanging only ceiling fan on same position and connecting up including provision of cable from ceiling rose or connector to fan, all as per specified and directed. Note : All unserviceable part will be replaced and deemed in quoted rates.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, lumen efficacy 110 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
-ditto- as per Item No. 39 but of 1 X 5 Watt capacity in polycarbonate housing with lumen output not less than 100 lumen per watt
S&F LED Bulkhead fitting 09/10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed.
S&F in repairs MCB Single Pole 5 to 32 Amp, 240 Volt, AC, 'B' series for fixing on MCB DB's, 10kA, 50Hz including connecting up complete all as specified and as directed.
S&F in repairs MCB Single Pole & Neutral, 40 Amp, 240 Volt, AC, 'C' series for fixing on MCB DB's, 10kA, 50Hz including connecting up complete all as specified and as directed.
S&F in repairs Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F in repairs Sheet Metal enclosure, single pole with a 2 pin and earth plug and socket with and including 1 No MCB single pole, 32 Amp, 240 Volt and connecting up complete all as specified and as directed.
S&F in repairs VTPN DB 4 way, double door, suitable for MCCB's upto 250 A complete, IP 54 protected, 4+4+4 modules with and including 4 pole, 160 Amps MCCB, 25kA and making good surfaces incl any touch up of the wall surface due to chaning of fitting shall be done by contractor with similar surface finish without extra cost to the department. All the cementing/civil work will be in deemed to be in quoted rates complete all as specified and directed. (NOTE: Cost of incoming MCCB shall be deemed to be included in the quoted rate. Outgoing MCBs shall be measured and paid seperately)
M/s Satguru Traders
shiv shanker enterprises
YESH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .