Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical PLOT NO 1076 BEHERA SAHI NAYAPALLI BHUBANESWAR 751012 | KHORDHA | ODISHA | 751012 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 2RA 135 PRESS COLONY KHARVEL NAGAR UNIT III BHUBANESWAR 751001 | BHUBANESWAR | KHORDHA | ODISHA | 751001 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹14.8 L
EMD Value
₹29,532
Closing Date
6 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR NISER
NISER Bhubaneswar, Jatni
Provision of flood light arrangement in New football field and Kho Kho Ground inside NISER campus, Jatani
2026_NISER_929696_2
NISER/IWD-ELECT /SL/2026-27/06
Open Tender
Electrical Works
Works
60 days
NISER Bhubaneswar, Jatni
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹29,532
Yes
9 Nov 2026
30 Oct 2026
9 Nov 2026
30 Oct 2026
6 Nov 2026
31 Oct 2026
75 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 10 Meter GI Pole:
Supply, installation, testing & commissioning of Round top 10 m octagonal galvanisedtaperedpole(abovegroundlevel),fabricated out of 3mm thick sheet complete with in built junction box,baseplate size 300x300x20mm,two arm of ERW galvanised pipe of 60mm dia and 1min length on two side of pole shaft as per detailed specifications. Pole should be made of BSEN 10025 grade mild steel, polygonal and continously tapered in three sections, hot dipped galvanised (as per BSENISO1461and suitable for wind velocityof 200Km/Hr design life 25 years, terrain category -2. Juncion box should be provided 500 mm above base plate with 4 Nos terminals on epoxy insulators, 2 No.6A SP MCB &1 no.neutral link.Base plate should have 4 Nos holes on each side suitable for mounting on RCC foundation 250 mm above FGL. General specifation and drawing should be approved from EIC before manufacturing) | 8 | Each | - | - |
| 2 | RCC Work for foundation
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm
nominal size) | 24.19 | Cum | - | - |
| 3 | Centering and shuttering for foundation
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns | 96 | Sqm | - | - |
| 4 | PCC Work for foundation
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) | 4 | Cum | - | - |
| 5 | Steel reinforcement Work for foundation
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hot rolled deformed bars | 480 | Kg | - | - |
| 6 | GI Wire Earthing for foundation
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 120 | Meters | - | - |
| 7 | Cable Laying and cable route marker with foundation Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering with brick on 3 side and refilling the trench etc as required along with cable route marker of 1 feet height above ground with PCC foundation. | 300 | Meters | - | - |
| 8 | SITC of 350W LED FLOOD LIGHT Supply, installation, testing & commissioning of 350W led Flood light Fixture as per specification mentioned in Annexure-5 of NIT | 16 | Nos | - | - |
| 9 | WIRING FOR FIXTURE Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable insurface/recessedsteelconduitasrequired.(2X1.5sq.mm+1 X1.5sq. mmearth wire) | 300 | Meters | - | - |
| 10 | Cable end Termination Supplyingandmakingendterminationwithbrasscompressionglandand aluminium lugs for following size of PVC insulated and PVC sheathed / XLPEaluminiumconductorcableof1.1KVgradeasrequired.4CX16sq. mm Cable | 10 | Set | - | - |
stage.html
html • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.74 MB
Tendernotice_2.pdf
PDF • 0.73 MB
BOQ_979980.xls
BOQ • 0.25 MB
corrigenduminTechnicalBid.pdf
Additional Documents • 0.71 MB
TenderNotice.pdf
Tender Documents • 2.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .