Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | ₹22.0 L Quoted ₹22.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.6 L+₹28,358 (1.27%)Rejected-Finance | ₹22.6 L+₹28,358 (1.27%) | L2 | Rejected-Finance Not being Lowest |
| 3 | L3₹22.8 L+₹49,349 (2.21%)Rejected-Finance | ₹22.8 L+₹49,349 (2.21%) | L3 | Rejected-Finance Not being Lowest |
| 4 | L4₹22.8 L+₹51,100 (2.29%)Rejected-Finance | ₹22.8 L+₹51,100 (2.29%) | L4 | Rejected-Finance Not being Lowest |
Tender Value
₹30.3 L
EMD Value
₹60,600
Closing Date
7 Oct 2022, 6:00 pmClosed
GE Chandimanidr
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-60/2022-2023 SPL REPAIR TO CHAJJA, BALCONY, ROOF TREATMENT, PROVN OF TOILET AND OTHER WORKS UNDER AGE B/R II AT CHANDIMANDIR
2022_MES_548359_1
GE/CHM-60/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹60,600
Yes
17 Nov 2022
29 Aug 2022
14 Oct 2022
29 Aug 2022
7 Oct 2022
23 Sept 2022
Amount
Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement or any mortar complete all as specified & directed.
Dismantling wrought iron or mild steel as in gates, grills, posts etc or in any description not otherwise provided for, complete all as specified and directed
Demolition of mud phuska as in roof of any thickness incl plastering and leeping etc (whether full thickness removed or only a part thereof) complete all as specified & directed.
PCC 1:2:4 type B-0 (using 12.5m graded crushed stone aggregate) , as in padding over roof, mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. NOTE : (water proofing compound to be measured and paid separately)
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm over clean RCC/plastered roof surfaces and adjoining vertical surfaces complete all as specified.
40mm thick brick tiles with including 20mm thick cement mortar 1:4 jointed grouted and pointed complete mixed with crude oil 5% by weight of cement complete all as specified and directed.
All as per serial item No 6 herein before but except tiles –ditto-
Rendering 20mm thick (average thickness) plaster in cement mortar 1:4 mixed with WPC on concrete roof surfaces including flashings and junction of parapets etc , finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only).
Demolition of brick work, stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles all as specified & directed by Engineer-in-charge.
Brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed.
Brick work with sub class ‘B’ bricks of class designation 10 (min. compressive strength 100Kg/sqcm) old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed.
Demolition of plain cement concrete in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
PCC 1:2:4 type B-1 (20 mm graded stone aggs) as in coping, roof padding, roof kerbs rounded or chamfered on edges complete all as specified and directed.
Supply only integral water proofing compound (ISI Marked) complete all as specified & directed.
Material and labour machine cut Kota Stone Slab flooring, 18 to 20mm thick, best quality (one piece in stair case tread) over and including cement screed bed 20mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab, cutting, rubbing, grinding and polishing (mirror finish) complete all as specified and directed.
Machine cut kota stone slab flooring 15-18mm thick of one piece in stair case, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as in in skirting, dados, risers to steps, pillar etc, laid over and including 10mm screed layer in cement mortar 1:4, cutting, rubbing, grinding and polishing complete, all as specified.
Demolition of RCC water tank of any description at any position removing all the rubbish and making good the distured surface portion with cement concrete 1:2:4 complete all as specified and directed
500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, PTMT 20mm dia ball valve, including dismantling of existing water tank and removing from site all as specified in SSR Part-I and all as directed by Engineer-in-charge.
500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, PTMT 20mm dia ball valve, complete all as specified in SSR Part-I and all as directed by Engineer-in-charge.
1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, complete all as specified in SSR Part-I and all as directed by Engineer-in-charge.
Dismantling of cast iron pipes with all fittings and fixing acessories, jointed in cement mortar 75-100 mm bore, at any location, complete all as specified.
Cast iron soil, waste and vent pipe 100mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, with and including lead joint, fixed to wall, using Flat iron clamp 25 x 3mm complete all as specified and directed.
All as per item No. 23 hereinbefore but except pipe using old pipe retrieved
Cast iron soil, waste and vent pipe 75mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, with and including lead joint, fixed to wall, using Flat iron clamp 25 x 3mm complete all as specified and directed.
All as per item No. 25 hereinbefore but except pipe using old pipe retrieved
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc and cutting chases for concealed water tubing & making good, cutting not exc 10 cm girth, in brick walls complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store of 15 mm bore complete all as directed by Engineer-in-charge.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store of 20 mm bore complete all as directed by Engineer-in-charge.
15mm dia concealed GI tubing medium grade with all fittings to walls, ceiling or laid under floors including cutting chases and making good in cement mortar 1:3 complete all as specified and directed.
All as per item No. 30 hereinbefore but except GI pipe using old pipe retrieved
20mm dia concealed GI tubing medium grade with all fittings to walls, ceiling or laid under floors including cutting chases and making good in cement mortar 1:3 complete all as specified and directed.
All as per item No. 32 hereinbefore but except GI pipe using old pipe retrieved
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. at the places out side the premises complete all as specified and directed.
Rendering 15mm thick plaster in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces and finishing the surface fair and even without using extra cement complete all as specified and directed.
Rendering 15mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick plaster in cement mortar 1:4 mixed with WPC on concrete roof surfaces and finishing the surface even and fair without using extra cement, all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only).
Rendering 10mm thick in CM 1:3 on fair faces of concrete/brick surfaces as in ceiling, chajja, etc. finished fair and smooth complete all as specified and directed.
Three coats of white wash on wall surfaces including preparation of new plastered surfaces complete all as specified and directed
Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed
Preparation of new plastered surfaces of walls and applying two coats of cement base paint , complete all as specified and directed.
Complete removal and preparation of old surfaces of walls and applying two coats of cement base paint on external walls , complete all as specified and directed
Preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 complete all as specified & directed by Engineer-in-charge.
Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings and removal, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating (AZ 70) GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engineer-in-charge.
Two coats of synthetic enamel paint on steel and iron surfaces over 10 cm width or girth over a coat of red oxide primer including preparation of new surfaces complete all as specified & directed.
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed.
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
PVC (SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
110mm bore PVC (SWR) bends any radius complete all as specified and directed.
75mm bore PVC (SWR) bends any radius complete all as specified and directed.
Taking down, chipping and removing the loose, split, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforcement, wire brushing and cleaning the exposed steel reinforced bar, apply rust remover over the cleaned re-barsurface wash the re-bar with clean water for removing all rusts fromthe old re-barsurfaces, fixing new reonforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified cement and quartz sand mortar in CM 1:3 mix, 40mm average thick in two coats, with and including polymer @10% by weight of cement, including erecting and dismantling steel scafoldingfor carrying out the work upto height of 10 metre (Appx) complete all as specified and as directed. Note:- Make;- Dr fixit/ Sunanda/chemestik/fosrock.
Welded steel wire fabric, fixed complete to steel members , Weight per square n.exc 4Kg metre complete all as specified and directed.
Factory made coloured chequered cement concrete tiles 300mm x 300mm x 22-25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Concrete interlocking paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, and including laid over 25mm thick sand cushioning, complete all as specified and directed
Concrete interlocking paver block, with grey cement and no pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, and including laid over 25mm thick sand cushioning, complete all as specified and directed
Plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protections, 75MM thick, finished fair and even without using extra cement, with 10mm wide joints to full depth @ 3m c/c and at corners, filled with mastic mortar, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, sub base and mass concrete complete all as specified & directed.
40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring, finished even and fair including finishing surfaces by brooming/ Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, all as specified and directed.
Material and labour, plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, sub base and mass concrete complete all as specified & directed.
75mm thick PCC 1:4:8 type D-2 (using 40m graded crushed stone aggregate) as in sub base flooring, finished even and rough to receive top layer, all as specified and directed.
Cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore, including jointing to waste pipe set in cement concrete type , fixed as in repair, complete all as specified.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement 100 mm bore, including jointing to waste pipe set in cement concrete type , fixed as in repair, complete all as specified.
Vitreous china squatting pan "orissa" pattern, size 580 x 440 mm white, with integral foot rest (excluding flushing cistern and flush pipe) and making good to the floor, fixed as in repair complete all as specified & directed by Engineer-in-charge.
Vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, set with cement concrete, complete all as specified & directed.
Cast iron 'P' or 'S' trap, ISI marked, suitable for 100 mm bore CI spun pipes complete all as specified and directed.
Vitreous china, wash down water closet pan, Pedestal pattern coloured with ‘P’ or ‘S’ trap in and, including PVC flushing cistern 10 ltrs capacity with seat cover, complete set, complete all as specified and directed.
Non skid ceramic coloured tiles, joint free, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 Square metre but not exceeding 0.18 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and 15mm thick screed bed in cement mortar 1:6, including dismantling of old tiles complete all as specified and directed.
Material and labour glazed ceramic tiles, coloured in vertical surface 300mm x 450mm x 7mm, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles, joint free, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 Square metre but not exceeding 0.18 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of black japan paint complete all as specified & directed by Engineer-in-charge.
PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC long bend, set with concrete and making good to floor, complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Removal of excavated material to distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Reinforced cement concrete (M-25 design mix, using crushed stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Reinforced cement concrete (M-25 , using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Mild steel hight stength deformed TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Mild steel hight stength deformed TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed.
Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed.
Use and waste, form work to flat surfaces of suspended slabs such as roof slab, floor slab, landing, shelves etc not exceeding 200mm thick, including edges in any position, rough finished surfaces, complete all as specified and directed.
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil boubd bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/sqm on top of membrane, complete all as specified & directed.
Viterous china bowl urinal flat back, size of 465 x 355 x 265mm white (Minimum) with grating and union for discharge pipe including providing & fixing plugs, waste pipe , bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixed as in repair complete all as specified & directed by Engineer-in-charge.
Supply and fix 20mm bore ball valves high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210gms) , complete all as specified and directed.
Stop valve, fancy type, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
Angular stop cock, brass, cast copper alloy, chromium plated fancy type, screwed both ends for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
Bib taps brass, fancy type, short body with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, complete all as specified and directed.
Solid PVC frame having profile 105mm x 60mm , single rebate, made out of solid PVC foam with homogenous fine cellular structure having density not less than750Kg/ cum, smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws , complete all as specified and directed. Note :- Door frame shall be water proof, teRunning Metreite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing mentioned on Srl Page No. 134, 135 and 146 of SSR Part-II including aluminum iron mongery.
200 mm size aluminium , barrel tower bolt of extruded section and fixed complete all as specified and directed.
150 mm aluminium handles cast type complete all as specified and directed.
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed,complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel and fixed with screws or with welding to existing MS frames, 100 mm size, ISI marked, complete all as specified.
100mm butt hinges , extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed for PVC door, type B-21 complete all as specified and directed.
Vitreous china, table top wash hand basin, of size 600x 400mm white colour including waste coupling and waste pipe, complete all as specified and directed. MAKE : CERA Cat Part No Calida 1043 or equivalnent in Appx 'C'
Central hole Basin Mixer, without popup waste system with 450mm long copper pipes and brass nuts, cast copper alloy, chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
15mm dia PVC connection with PTMT nut, of length 450mm, fixed as in repairs complete all as specified and directed.
Supply and fix, mild steel framed work as in doors or gates etc of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-290-O or Fe-165 and fixed at site, completeall as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in hard/dense soil, complete all as specified and directed.
Hard core of broken stone or boulders gauge not exc 63 mm deposited spread and lavelled in layers n.exc 15 cm thick, watered & rammed to a true surface complete all as specified.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
All as per serial item 108 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed
All as per serial item 108 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 108 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting including 9 watts LED lamp complete all as specified and directed.
Indoor decorative extruded aluminium anodized housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaries' (LED batten shall be prewired box type, T8 retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage not more than 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glare free, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 1.0 sq mm complete all as apecified and directed.
MCB DB, with provision for incoming 2 pole (MCB / Isolator ) and single phase outgoing, suitable for surface and flush mounting, IP 43 protection, of metal 8 way complete all as specified and dircted.
MCB, SPN, 240 volt, 40Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB, SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
GI bracket made of GI pipe medium grade of 40mm dia, 1.5 mtr long, bend to shape of 120 degre ,fixed on pole/wall with clamp of size 50x6 of suitable length fixed with nuts/ bolts and 1.5 sqmm 2 core, 1.5 metre long flexible wire from connector / ceiling rose to light fitting complet,e fixed in repairs, all as specified and directed.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Exhaust fan metalic body 300mm sweep, 240 volt, 50 Hz, with louvers heavy duty, 1400 RPM, single phase including making connection with suitable size twin core cable complete all as specified and directed.
Cutting openings, through brick walls in round shape , for 300mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge.
Supply, laying & fixing along the poles/walls or passing through pipes or laid in trenches under floor or through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable, 1100 volt grade heavy duty with aluminium conductor overall served with an outer sheath of PVC complete of size 10 Sqmm 2 Core all as specified & directed by Engineer-in-charge. (Note:- Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately).
Supply and fix 25mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed Make : Finolex / Duraline /Rex
Standard Const. Co.
M/S Dhanpati Construction
KUNDRA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .