AGE I AF coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
REPAIR REPLACEMENT TO LT PANELS CIRCUIT BREAKERS AND OTHER CONNECTED WORKS
2026_MES_787460_1
8204_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Coimbatore
Class-E category-b (i)(see NIT for detail)
8 documents required · 8 mandatory
₹500
AGE I AF Coimbatore
₹32,000
Yes
2 Sept 2026
2 Sept 2026
17 Sept 2026
2 Sept 2026
15 Sept 2026
7 Sept 2026
2 Sept 2026 - 5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out in hard/dense soil for laying of UG cables/taking out cable covers all as specified and as directed. Note : During the time of excavation any damge in existing structure/pipes/cables the contractor rectify the same without any extra cost | 65 | Cum | - | - |
| - | Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thickness with hard/dense soil all as specified and as directed. | 34 | Cum | - | - |
| - | Removing excavated materials (soils) to a distance not exc 50m and depositing where directed at a level not exc1.5 m above the starting point all as specified and as directed. | 31 | Cum | - | - |
| - | Earth cushioning to UG cables using excavated soil riddled by using large sieve to separate the composite particles/roots etc and refilling in trenches all as specified and as directed. Notte: Punned thickness will be measured for payment. | 24 | Cum | - | - |
| - | Supply and lay reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm all as directed. | 1,500 | Each | - | - |
| - | Relaying reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm obtained durinbg excavation all as directed. | 600 | Each | - | - |
| - | Supply, layig, connecting, testing and commissioning of 185 Sqmm 3.5 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed.
Make: Havells/Polycab/Finolex/Paragon/Gloster/Nicco | 90 | RM | - | - |
| - | All as per item No 7 above but 3.5 core 120 Sq mm | 60 | RM | - | - |
| - | All as per item No 7 above but 3.5 core 95 Sq mm | 80 | RM | - | - |
| - | All as per item No 7 above but 3.5 core 50 Sq mm | 100 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_882529.xls
BOQ • 0.40 MB
General_pages_.pdf
Tender Documents • 0.47 MB
Particular_Specifications.pdf
Tender Documents • 0.33 MB
credit_exc.pdf
Tender Documents • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .