| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 43 SEC NO 5 GROUND FLOOR TRIKUTA NAGAR JAMMU JAMMU JAMMU KASHMIR 180012 | JAMMU | JAMMU AND KASHMIR | 180012 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
15 May 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer STD Kathua
Executive Engineer, Sub Transmission Division hatli Morh Kathua
Repair and Maintenance of 33by11 KV Receiving Stations, 33KV Lines, 66by11 KV Receiving Stations and 66 KV Lines falling under the jurisdiction of STD Kathua
2021_PDD_122143_1
STDK/eNIT/2021-22/02
Open Tender
Electrical and Maintenance Works
Item Wise
30 days
Anywhere in District Kathua
Please refer Tender Document
6 documents required · 6 mandatory
₹1,000
Executive Engineer STD Kathua
₹10,000
Kathua
8 Jun 2021
9 Apr 2021
17 May 2021
9 Apr 2021
15 May 2021
9 Apr 2021
9 Apr 2021 - 15 Apr 2021
19 Apr 2021
90 days
Amount
Annual Stage Contract for Repair and Maintenance of 66kV Lines falling under the jurisdiction of Sub Transmission Division(JPDCL) Kathua for the year 2021-2022 or till the next stage contract.The rates provided by the bidder are deemed to be inclusive of all taxes labour cess,GST etc and return of red material to divisional stores wherever applicable.
Transportation, Erection, testing and commisssioning of ST Poles including excavation of pit and back filling including fixing of Double x-arm, Top Disc Clamps, Insulators and braces as per REC construction Standard (Material to be supplied by department)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Dismantling of ST poles complete with allied accesories and subsequent return of same to the divisional Store
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Dismantling of DW poles of different sizes complete with allied accesories
Dismantling of ST poles complete with allied accesories and disposal of same
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Providing one coat of red-oxide and subsequent two coats of silver (aluminium) paint to the ST Poles before installation or at the time of replacement.
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Straightening of tilted ST poles (16Mtr/13 Mtr/11Mtr/9Mtr)
Fixing of P.G Clamps, 4-bolt type suitable for 0.2 ACSR, 0.15 ACSR and 0.1 ACSR (Material to be Supplied by the Department)
Transportation, Laying,stringing ,tensioning and binding of ACSR Conductor including removal of knots for ACSR Conductor of sizes as per REC Construction standard (material to be provided by the department)
Dismantling of old damaged/wornout conductor ( 0.2 ACSR, 0.15 ACSR and 0.1 ACSR)
Restringing of ACSR conductor 0.2 ACSR, 0.15 ACSR and 0.1 ACSR
Providing and Erection of 66 KV disc insulators set of 5 no. with suspension fittings including punching of locking pins complete.
Porcelain Type
Polymer Type
Transportation and Erection of 66 KV disc insulators set of 5 no. with suspension fittings including punching of locking pins complete (material to be provided by the department)
Porcelain Type
Polymer Type
Providing and Erection of 66KV disc insulators set of 5 no. with tension fittngs including punching of locking pins complete.
Porcelain Type
Polymer Type
Transportation and Erection of 66KV disc insulators set of 5 no. with tension fittngs including punching of locking pins complete(Material to be supplied by department)
Porcelain Type
Polymer Type
Installation,Testing and commissioning of 11KV Pin insulators Polymeric Type Composite pin type insulator .(material to be provided by the department)
Fixing of 66KV jumpers of all sorts.(Material to be Provided by the epartment)
Providing and fixing of Danger plates (6"x8") 4mm Thick, with clamps
Transportation and laying of new Earth wire in place of old worn out Earth wire including transportation of worn out to Divisional Store.
Re-fixing of Up-rooted Guys after opening of pits and refilling thereof.
Straightening of Tilted H-Frame after opening of half pits and refilling after straightening.
Providing and fixing of Anti climbing devices with clamps
Fabrication and fixing of Cross arms channel Iron(100x50x50x6mm)/50x50x6 Braces of angle Iron(65x65)as per site Requirement.with subsequent provision/application of one coat of red-oxide and two coats of silver (aluminium) paint to give even shade (Material other than paint to be Provided by the Department)
Extensive Branch cutting of trees coming in the coridor/close proximity of various 66KV line of Sub-Division. The job includes removal of branches etc with subsequent disposal of below mentioned 66kV lines Pertaining to Sub Transmission Sub Divison-I, Kathua
66kV Lines of Kathua & Hiranagar Sub-Divisions
Cement bottoming of ST poles (1:2:4 mix) as per REC standards( fom the base of the pole with planting depth of 1/6 th of the height of the pole) Material to be supplied by department
16 Mtr long ST poles (0.8 Cum/pole)
13 Mtr long ST poles (0.7 Cum/pole)
11 Mtr long ST poles (0.6 Cum/pole)
09 Mtr long ST poles (0.5 Cum/pole)
Transportation, Laying of guard netting per span with an average span of 40 Mtrs (Material to be supplied by the department)
Providing and fixing of Galvanised spiral Earthing (in a separate pit) of 8 SWG, G.I wire of 115 turns including fixing to the poles
Providing and fixing of earthing complete with GI pipe 40 mmm or GI rod 20 mm *(2.5 Mtr long through GI Strip)
Transportation and Fixing of 66 KV Galvanised Stay Set Complete (Material to be provided by the department)
Supply, transportation, Fixing installation testing and commissioning of 66 KV isolator set by way of replacement of damaged one (heavy duty)
Transportation, Fixing installation testing and commissioning of 66 KV isolator set by way of replacement of damaged one (heavy duty)(Material to be supplied by department)
Laying Testing and commissioning of 66 KV Grade Single Core Aluminum round wire armoured XLPE Cable, FRLS 1 Spare Cable
Annual Stage Contract for Repair and Maintenance 66/11 KV Receiving Stations falling under the jurisdiction of Sub Transmission Division (JPDCL) for the year 2021-22 or till the next stage contract. The rates provided by the bidder are deemed to be inclusive of all taxes, labour cess, GST, etc. and return of dismantled material to Divisional Stores where ever applicable.
Transportation, Installation, testing and Commissioning of Electronic Relay Overcurrent/Earth Fault by way of replacement of damaged/burnt of the same ratio,type , make and class already installed in the 11 KV panel conforming to IEC -61850 standard and operating voltage 30-36 V DC (Material to be supplied by department)
Supply, Installation, testing and Commissioning of Electronic Relay Overcurrent/Earth Fault by way of replacement of damaged/burnt of the same ratio,type , make and class already installed in the 11 KV panel conforming to IEC -61850 standard and operating voltage 30-36 V DC
Transportation, Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar (50 mm x 12 mm) Including nuts and Bolts.(Material to be supplied by department)
Transportation, and Replacement of Damaged 11 KV spout Bushing for 11KV VCB Panels of Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc (Material to be supplied by department)
Transportation and Replacement of 11 KV Vacuum interupters (Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc (Material to be supplied by department)
Transportation and Replacement of 11KV vacuum Interrupters Housing Assembly (Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc (Material to be supplied by department)
Transportation, Installation, testing and Commissioning of Electronic Differential Relay of different Make in 66KV C&R Panel (Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc (Material to be supplied by department)
Providing and Replacement of Tripping Coils/Closing coil 36 V DC (Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc
Replacement of Tripping Coils/Closing Coils 36 V DC (Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc (Material to be supplied by department)
Transportation, Installation, testing and Commissioning of 11 KV CT's Set I/D type cast Resin by way of replacement of damaged one of same ratio amd make already installed in panel for various 11 KV Panel makes Vijai, Siemens, , Alstom, Sudhir, Stelmec, Easun Reyrolle, Crompton,Electric Field conforming to IEC 60044-1-2000 standard (Material to be supplied by department)
Supply and Installation, testing and commissioning of 11 KV CT's I/D type of various types (Vijai,Stelmec ,Easun Reyrolle, Alstom, Sudhir, Electric Field,Crompton,Siemens etc
Routine Maintenance of 11 kv indoor VCB Panel
Transportation, Installation, testing and Commissioning of 11 KV PT's Set I/D (11KV/110 V) type cast Resin by way of replacement of damaged one of same ratio and make already installed in panel for various 11 KV Panel makes Vijai, Siemens, , Alstom, Sudhir, Stelmec, Easun Reyrolle, Crompton,Electric Field conforming to IEC 60044-1-2000 standard (Material to be supplied by department)
Supply,Transportation, Installation, testing and Commissioning of 66 KV CT's Set outdoor type conformong to IEC- 185 and IS 2705(Part 1 to 4) by way of replacement of damaged one of different Ratios
Transportation and Installation, testing and Commissioning of various 66 KV CT (Material to be supplied by department)
Routine Maintenance of 66 kv outdoor CT Set by of checking of oil level, IR Value, filling of oil if required, arresting of leakage, etc. (Oil to be provided by the Department)
Transportation and Installation, Testing and Commissioning of 66 KV PT , 20 VA, 3P- 66KV/110V√3 outdoor type conformong to IS 3156(Part 1 to 3) by way of replacement of damaged one (Material to be supplied by department)
Supply,Transportation and Installation/Testing and Commissioning of 66 KV PT , 20 VA, 3P- 66KV/110V√3 outdoor type conformong to IS 3156 (Part 1 to 3) by way of replacement of damaged one
Checking of oil level, measurment of IR value, filling of oil (if required) and tightning of jumpers including
Routine Maintenance of 66 kv outdoor PT Set by of checking of oil level, IR Value, filling of oil if required, arresting of leakage, etc. (Oil to be provided by the Department)
Routine maintenance of 66 KV outdoor SF6 by way of tightening of loose nuts and bolts, greasing/lubrication of movable parts, checking the movable alignment of different phases, cleaning of insulating chambers, etc
Repairing/Repalcement of 11 KV VCB's (Material to be supplied by department)
Tripping Mechanism
Modification of mechanism
Re-Setting Links
Replacement of operating shaft
Shower Contact
Isolating Sockets
Closing Mechanism (Replacement)
High Tension Spring
Tripping Shaft
Rollers
Latch Assembly
Deco Spray painting
Rectification, realignment and Setting right of 11 KV VCB (siemens, Easun Reyrolle, Vijai,Crompton,Stelmec,Sudhir,Electric Field, alstom) (Material to be supplied by the Contractor, if any)
Transportation, Installation, Testing and Commissioning of 11 KV Panels equipments/items by way of replacement of following items (Material to be supplied by department)
Voltmeter 11KV/110V
Ampere meter
LED panel Indicators
Push Button
Master Tripping Relay
HRC fuse with Base -16 Amps
Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc of C&R Panel
Connecting Ribs
Auxilary Switch
Auxillary Relay -30 A
TNC Switch
Trip Circuit Supervision Relay
Electronic Hooter/bell (Replacement)
Annunciator
Antipumping device
Transportation, Installation, testing and Commissioning of various 11 KV VCB Panel (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of 66 KV C &R Panel equipments/items (Material to be supplied by department)
Repairing of 66 KV C&R Panel
Replacement of Bucholz, Winding Temperature, Oil Temperature, Tripping Relay
Replacement of Bucholz, Winding Temperature, Oil Temperature, Alarm Relay
Replacement of Master Tripping Relay
Replacement of Closing Trip Switch
Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc
Deco Spray painting
MW Meter (Replacement)
Energy Meter (Replacement)
Electronic Hooter (Replacement)
Close/ Trip Switch
HRC fuse with Base -1 Amps
HRC fuse with Base -6 Amps
HRC fuse with Base -16 Amps
LED panel Indicators
Push Button
Annunciator
O/C and E/F relay
Restricted E/F relay
Transportation, Installation, testing and Commissioning of various 66 KV C& R Panel (Material to be supplied by department)
Repairing of 66 KV SF6 Breaker (Material to be supplied by department)
SF6 Gas filling
66 KV Porcelain Insulator (Replacement)
Operating Rods (Replacement)
Closing Coils with Housing (Replacement)
Tripping Coils wih Housing (Replacement)
Motor Charging 240 AC
Contactor (Replacement)
Gasket
Operating Shaft
Mechanism Housing
Gear Assembly
Auxillary Switch
Rollers
Charging Rod/Wheels
Replacement of SF6 gas meter
Transportation, Installation, testing and Commissioning of 66KV SF6 breaker (Material to be supplied by department)
Rectification, re alignment and Setting right of 66 KV SF6 breaker (ABB, crompton greaves etc)
66/11 KV Power Tranformer
Topping of oil including Trasportation
Replacement of 66KV Bushing including Trasportation
Replacement of 66KV Bushing Rods including Trasportation
Replacement of 11 KV Bushing including Trasportation
Replacement of 11 KV Bushing Rods including Trasportation
Transportation, Installation and fixing of Bi-Metallic Clamps of Bush Rod
Tap Changer Contact replacement
Tap Changer Contact Repairs
Gasket Set of Bushing replacement including Trasportation
Gasket Set of Tap Changer/Radiators replacement including Trasportation
Male contact (Replacement)
Female contact (Replacement)
Dehydration/Filteration of Power Transformer Oil
Buchloz Relay replacement including Trasportation
Winding Temperature Meter with Probe replacement
Repairing of leakage of radiators by way of gas welding
Trasportation and Replacement/Repairing of damaged cooling fans of radiators
Oil Temperature meter With Probe replacement including supply of material
Supply and Replacement of Silica gel
Transformer neutral Earthing complete with cu Strip replacement including supply of material
Installation & commissioning of Power Transformer including assembly fixing of bushes, radiator ,fans(if any), wiring of instrument
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Retrofitted 11KV VCB:-
Modification of Tripping Mechanism with Complete Assembly retrofitted from to new Mechanism of same make duly Modified in Order to Have reliable tripping mechanism as well as smooth operational functionalities.
Retrofitted 66KV Sf6 Breaker:-
Modification of Tripping Mechanism with Complete Assembly retrofitted from to new Mechanism of same make duly Modified in Order to Have reliable tripping mechanism as well as smooth operational functionalities.
66KV isolator
Trasportation, Installation,Testing and Commissioning of 66 KV Isolator without Earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60168 standard (Material to be supplied by department)
Trasportation, Installation,Testing and Commissioning of 66 KV Isolator with Earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60168 standard (Material to be supplied by department)
Checking of moving/fixed contacts, cleaning ,greasing of contacts,cleaning of post insulator,auxillary switches contacts ,tightning of clamps
Repair of damaged 66 kvisolator including replacement of mouth, post insulator, damaged blades,isolator pipe etc including supply of neccesary material.
66 KV Lightning Arrestor
Trasportation, Installation,Testing and Commissioning of 66 KV LA including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60099-4 standard (Material to be supplied by department)
Measurement of IR value, leakage current and tightning of droppers
Eathing Mat
Measurement of earth resistivity, checking of electrical continuity of equipment earthing, tightning of earthing connectors,removal of rust from bolted earth connections and retightning
Trasportation, Installation,Testing and Commissioning of 11 KV Panel (Material to be supplied by department)
Installation, testing and commissioning of 2' x 10 mm Copper Bus Bar (Material to be supplied by department)
Trasportation, Installation,Testing and commissioning of 100A MCCB with enclosure box (Material to be supplied by department)
Transportation and Installation of Enclosure Box for Bus Bar (Material to be supplied by department)
Battery bank and Battery Charger of 36 V
Transportation, Installation, Testing and Commissioning of 36 V automatic battery charger with Float cum Boost Charger (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 200 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment conforming to IEC- 60896 standard (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 100 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment conforming to IEC- 60896 standard (Material to be supplied by department)
Repair of Battery Charger of 36 V
Repair/replacement of Battery cell of 2V 100AH/2V 200AH including suply of battery cell
11 KV Power cables
Transportation, laying, Testing and Commissioning of 11 KV armoured XLPE power cable conforming to IS 7089(Part-II)-1895 by way of replacement and dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench making roll to safer sideoutside and carriage of same to store and laying in the power cable trench, peeling the cable , fixing the earth clamps and fitting the HS cable kit to both ends, fixing to panel and outgoing structure including testing and commissioning. (Material to be supplied by department)
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Replacement of 11 kv Damaged Cable kits
Transportation, Installation, testing and Commissioning of 11 KV , heat shrinkable cable kit Indoor type conforming to IS 13573/1993 with latest ammmentments if any by way of replacement and dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to panel and outgoing structure.complete job testing and commissioning. (Material to be supplied by department)
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Installation, testing and Commissioning of 11 KV , heat shrinkable cable kit outdoor type conforming to IS 13573/1993 with latest ammmentments if any by way of replacement and dismantling of damaged cable from the outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to outgoing structure.complete job testing and commissioning. (Material to be supplied by department)
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Laying and Fixing of 2-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 4-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 8-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 12-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Replacement of damaged 11 kv Post Insulator or providing additional post insulator (Material to be supplied by department)
Replacement of 66KV busbar of single condductor with size upto 0.4 sq. inch including replacement of disc insulators, tigtning of clamp, jumpers droppers if required. (Material to be supplied by department)
Replacement of damaged LED bulbs of control room building and switchyard lighting (Material to be supplied by department)
11KV Auxillary Transformer
Topping of oil (Material to be supplied by department)
Replacement of HT/LT bushing(Material to be supplied by department)
Replacement of HT/LT bush rods(Material to be supplied by department)
Replacement of HT/LT bushing gaskets(Material to be supplied by department)
Repair of Auxillary Transformer including (Material to be supplied by department)
Installation of Auxillary Transformer (Material to be supplied by department)
Replacement of LT cable 3½ core 120mm² for auxillary transformer (Material to be supplied by department)
Dragging (upto avg. 50 mtr) and rotation if required of Power transformer 66/11 kv
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Loading of Power Transformer to Sub Station Bed/Platform
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Unloading of Power Transformer to Sub Station Bed/Platform
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Supply and installation of new outgoing structures on PCC poles 9m with DO set, LA and other accessories.
Transportation and installation of new outgoing structures on ST poles 9m with DO set, LA and other accessories. (Material to be supplied by department)
Transportation and Installation/Testing and Commissioning of 11 KV Isolator, 800 A (with/without Earthing blade)conforming to IS 9921/IEC -129 601 standard (Material to be supplied by department)
Replacement of 11KV D.O set (Material to be supplied by department)
Replacement of 11KV LA set (Material to be supplied by department)
Earthing complete with GI pipe/flat (Material to be supplied by department)
Earthing complete with GI pipe/flat and GI Plate (Material to be supplied by department)
Fencing of Switchyard with Mesh fencing 2 Mtr. High,angle iron post complete along with cement bottoming of angle posts (Material to be supplied by department)
Installation of damaged/broken windows panes with fibre sheet of control room (Material to be supplied by department)
Deweeding of vegetation in outer yard
Removing of Stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation ,levelling of area with existing stone metal
Providing additional stone metal and its carriage and laying in outdoor yard
Repair and maintenance of AC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc including suppply of material.
Repair and maintenance of DC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc
Painting of internal/external walls and roof with approved brand of paint , doors and window of control room buiding with paint of approved brand like asian paint,nerolac etc including supply of material.
Painting of internal/external walls and roof with approved brand of paint , doors and window of control room buiding with paint of approved brand like asian paint,nerolac etc (Material to be supplied by the Department)
Fencing of Receiving Station with barbed wire 2 Mtrs High,angle iron post complete with 7 horizontal wires and 2 cross wires along with cement bottoming of angle posts including suppply of material.
Repair/Replacement of ceiling fan of control room building
Supply and Spray Painting of Power Transformers as per latest BIS
Supply and Spray Painting of outdoor breakers as per latest BIS
Supply and spray Painting of outdoor CT's as per latest BIS
Supply and Spray Painting of outdoor PT's as per latest BIS
Supply and Spray Painting of Control & Relay Panel as per latest BIS
Supply and Spray Painting of 20 MVA Power Transformer
Supply and Spray Painting of 10 MVA Power Transformer
Supply and Spray Painting of 6.3 MVA Power Transformer
Supply and Spray Painting of 5MVA Power Transformer
Cleaning of roof of Control room building as per PWD norms
Construction of foundation of different equipments like 66 KV CT's, 66 KV PT's, 66 KV SF6, 66 KV Isolators, etc. (As per the PWD Norms)
Erection of structure of different equipment
Watering of earthing at different Receiving Stations
Annual Stage Contract for Repair and Maintenance of 33kV Lines falling under the jurisdiction of Sub Transmission Division(JPDCL) Kathua for the year 2021-2022 or till the next stage contract.The rates provided by the bidder are deemed to be inclusive of all taxes labour cess,GST etc and return of red material to divisional stores wherever applicable. The detail of Lines is as under:-
33 kV Lines of Billawar Sub-Division
Transportation (From Divisional Store, Kathua), Erection, testing and commisssioning of given below Poles including excavation of pit and back filling including fixing of Double x-arm, Top Disc Clamps, Insulators and braces as per REC construction Standard (Material to be supplied by department)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Dismantling of below mentioned poles (Complete Job) with allied accesories and subsequent return of same to the divisional Store at Kathua
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
Replacement of Rotten/crack/weak of below mentioned poles (Job include Transportation from Divisional Store Kathua, dismantling of existing poles and allied material and refixing of the same)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Providing one coat of red-oxide and subsequent two coats of silver (aluminium) paint to the ST Poles before installation or at the time of replacement.
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Transportation from (Divisional Store kathua) and Fixing of P.G Clamps, 4-bolt type
For ACSR Dog Conductor
For ACSR Panther Conductor
Transportation, Laying,stringing ,tensioning and binding of ACSR Conductor including removal of knots for ACSR Conductor of sizes as per REC Construction standard (material to be provided by the department)
ACSR Dog Conductor
ACSR Panther Conductor
Dismantling of old damaged/wornout conductor and its carriage to Divisional Store Kathua
ACSR Dog Conductor
ACSR Panther Conductor
ACSR Rabbit Conductor
Transportation and Erection of 11 KV disc insulators set of 3 nos. with tension fittings (For ACSR Dog/Panther Conductor) including punching of locking pins complete (material to be provided by the department)
Porcelain Type
Polymer Type
Supply and Erection of 11 KV disc insulators set of 3 nos. with tension fittngs (For ACSR Dog/Panther Conductor) including punching of locking pins complete (Material to be supplied by department)
Porcelain Type
Polymer Type
Transportation and Erection of 11 KV disc insulators set of 3 nos. with suspension fittngs (For ACSR Dog/Panther Conductor) including punching of locking pins complete.
Porcelain Type
Polymer Type
Supply and Erection of 11 KV disc insulators set of 3 nos. with Suspension fittngs (For ACSR Dog/Panther Conductor) including punching of locking pins complete (Material to be supplied by department)
Porcelain Type
Polymer Type
Transportation,Installation,Testing and commissioning of 33 KV Pin insulators Polymeric Type Composite pin type insulator (material to be provided by the department)
Replacemet of damaged Disc Insulators
Replacement of damged 33 KV Pin Insulators
Fixing of 33 KV jumper of all sorts .(Material to be Provided by the epartment)
Providing and fixing of Danger plates (6"x8") 4mm Thick, with clamps
Re-fixing of Up-rooted Guys after opening of pits and refilling thereof.
Straightening of Tilted H-Frame (4-Pole Structure) after dismantling hardware material and refixing of the same after straightening.
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Providing and fixing of Anti climbing devices with clamps
Fabrication and fixing of Cross arms channel Iron(100x50x50x6mm)/50x50x6 Braces of angle Iron(65x65)as per site Requirement.with subsequent provision/application of one coat of red-oxide and two coats of silver (aluminium) paint to give even shade (Material other than paint to be Provided by the Department)
Extensive Branch cutting of trees coming in the coridor/close proximity of various 33 KV line of Sub-Division. The job includes removal of branches etc with subsequent disposal of below mentioned 33 kV lines Pertaining to Sub Transmission Sub Divison-III, Billawar
33 kV Lines of Sub-Division Billawar
Cement bottoming of poles of different type/length (1:2:4 mix) as per REC standards (from the base of the pole with planting depth of 1/6 th of the height of the pole)
Transportation, Laying of guard netting across the roads (Material to be supplied by the department)
Providing and fixing of Galvanised spiral Earthing (in a separate pit) of 8 SWG, G.I wire of 115 turns including fixing to the poles
Transportation and Fixing of 33 KV Galvanised Stay Set Complete (Material to be provided by the department)
Supply, transportation, Fixing installation testing and commissioning of 33 KV isolator with earthing blade (Pipe Type as per latest BIS Standard) set by way of replacement of damaged one (heavy duty)
Transportation, Fixing, installation testing and commissioning of 33 KV isolator with earthing blade (Pipe Type as per latest BIS Standard) set by way of replacement of damaged one (heavy duty)
Supply, transportation, Fixing installation testing and commissioning of 33 KV isolator without earthing blade (Pipe Type as per latest BIS Standard) set by way of replacement of damaged one (heavy duty)
Transportation, Fixing, installation testing and commissioning of 33 KV isolator without earthing blade (Pipe Type as per latest BIS Standard) by way of replacement of damaged one (heavy duty)
Tightening of loose/sagged conductor
ACSR Dog Conductor
ACSR Panther Conductor
ACSR Rabbit
Dismantling and re-stringing of conductor after necessary repair/joint
ACSR Dog Conductor
ACSR Panther Conductor
ACSR Rabbit
Dismantling and re-erection of uprooted poles (the Job included dismantling and re-erection of allied material)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Single Pole Supporting Structure) (the Job included dismantling and re-erection of allied material)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Double Pole Supporting Structure) (the Job included dismantling and re-erection of allied material)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Double Pole Tension Structure)(the Job included dismantling and re-erection of allied material)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Three Pole Tension Structure) (the Job included dismantling and re-erection of allied material)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Single Pole Supporting Structure)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Double Pole Supporting Structure)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Double Pole Tension Structure)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Straightening of Tilted poles (Three Pole Tension Structure)
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
09 Mtr PCC Poles
11 Mtr PCC Poles
09 Mtr Rail Pole
11 Mtr Rail Pole
Manual Carriage of Poles
16 Mtr long ST poles
13 Mtr long ST poles
11 Mtr long ST poles
09 Mtr long ST poles
Manual Carriage of Hardware Material per Quinttal including Cross-Arms, braces, clamps, insulators, etc.
Restoration of 33 KV Line damaged due to falling of trees on the Line
Plate type Earthing of Line Isolators (G.I 600mm x 600mm x 6mm, 50mm x 6mm, G.I Flat, Earthing Plate should not be less than 3 Meters)
Routine Maintenance of 33 KV Isolators
Replacement of damaged female contacts of 33 KV Isolators (Material to be provided by the Contractor)
Re-erection of uprooted guys
Tightening of loose guys
Annual Stage Contract for Repair and Maintenance 33/11 KV Receiving Stations falling under the jurisdiction of Sub Transmission Division (JPDCL) for the year 2021-22 or till the next stage contract. The rates provided by the bidder are deemed to be inclusive of all taxes, labour cess, GST, etc. and return of dismantled material to Divisional Stores where ever applicable.
Transportation, Installation, testing and Commissioning of Electronic Relay Overcurrent/Earth Fault by way of replacement of damaged/burnt of the same ratio,type , make and class already installed in the 11 KV panel conforming to IEC -61850 standard and operating voltage 30-36 V DC (Material to be supplied by department)
Supply, Installation, testing and Commissioning of Electronic Relay Overcurrent/Earth Fault by way of replacement of damaged/burnt of the same ratio,type , make and class already installed in the 11 KV panel conforming to IEC -61850 standard and operating voltage 30-36 V DC
Transportation, Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar (50 mm x 12 mm) Including nuts and Bolts.(Material to be supplied by department)
Supply, Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar (50 mm x 12 mm) Including nuts and Bolts.
Transportation, and Replacement of Damaged 11 KV spout Bushing for 11KV VCB Panels of different Make like Electric field, Stelmec , Pascal, Etc (Material to be supplied by department)
Transportation and Replacement of 11 KV Vacuum interupters of different Make Panels like Electric field, Stelmec , Pascal, Etc (Material to be supplied by department)
Transportation and Replacement of 11KV vacuum Interrupters Housing Assembly of different Make Panels like Electric field, Stelmec , Pascal, Etc (Material to be supplied by department)
Providing and Replacement of Tripping Coils/Closing coil 36 V DC of different Make Panels like Electric field, Stelmec , Pascal, Etc (Material to be supplied by the Contractor)
Replacement of Tripping Coils/Closing Coils 36 V DC of different Make Panels like Electric field, Stelmec , Pascal, Etc (Material to be supplied by the Department)
Transportation, Installation, testing and Commissioning of 11 KV CT's Set I/D type cast Resin by way of replacement of damaged one of same ratio amd make already installed in panel for various Make like like Electric field, Stelmec , Pascal, Etc conforming to IEC 60044-1-2000 standard (Material to be supplied by the Department)
Supply and Installation, testing and commissioning of 11 KV CT's I/D type of various types like Electric field, Stelmec , Pascal, Etc (Material to be supplied by the Contractor)
Transportation, Installation, testing and Commissioning of 11 KV PT's Set I/D (11KV/110 V) type cast Resin by way of replacement of damaged one of same ratio and make already installed in panel for various 11 KV Panel makes of various types like Electric field, Stelmec , Pascal, Etc conforming to IEC 60044-1-2000 standard (Material to be supplied by the Department )
Routine Maintenance of 11 kv indoor VCB Panel
Supply,Transportation, Installation, testing and Commissioning of 33 KV CT's Set outdoor type conformong to IEC- 185 and IS 2705(Part 1 to 4) by way of replacement of damaged one of different Ratios
Transportation and Installation, testing and Commissioning of various 33 KV CT (Material to be supplied by department)
Replacement of damaged 33 KV Outdoor CT Set by new one (Material to be provided by the department and lifted from the Divisional Store)
Routine Maintenance of 33 kv outdoor CT Set by of checking of oil level, IR Value, filling of oil if required, arresting of leakage, etc. (Oil to be provided by the Department)
Transportation and Installation, Testing and Commissioning of 66 KV PT , 20 VA, 3P- 66KV/110V√3 outdoor type conformong to IS 3156(Part 1 to 3) by way of replacement of damaged one (Material to be supplied by department)
Supply,Transportation and Installation/Testing and Commissioning of 66 KV PT , 20 VA, 3P- 66KV/110V√3 outdoor type conformong to IS 3156 (Part 1 to 3) by way of replacement of damaged one
Replacement of damaged 33 KV Outdoor PT Set by new one (Material to be provided by the department and lifted from the Divisional Store)
Routine Maintenance of 33 kv outdoor PT Set by of checking of oil level, IR Value, filling of oil if required, arresting of leakage, etc. (Oil to be provided by the Department)
Routine maintenance of 33 KV outdoor VCB by way of tightening of loose nuts and bolts, greasing/lubrication of movable parts, checking the movable alignment of different phases, cleaning of insulating chambers, etc
Replacement of damaged tripping/closing coil (36 V DC) (To be provided by the Contractor)
Repairing/Repalcement of damaged parts of 11 KV VCB's Indoor type (Material to be supplied by Contractor)
Tripping Mechanism
Modification of mechanism
Re-Setting Links
Replacement of operating shaft
Shower Contact
Isolating Sockets
Closing Mechanism (Replacement)
High Tension Spring
Tripping Shaft
Rollers
Latch Assembly
Deco Spray painting
Rectification, realignment and Setting right of 11 KV VCB of different Make Panels like Electric field, Stelmec , Pascal, Etc (Material to be supplied by the Contractor, if any) In case of Malfunctioning/breakdown of Panel
Transportation, Installation, Testing and Commissioning of 11 KV Panels equipments/items by way of replacement of following items (Material to be supplied by department)
Voltmeter 11KV/110V
Ampere meter
LED panel Indicators
Push Button
Master Tripping Relay
HRC fuse with Base -16 Amps
Re-wiring of Panel with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc . In case of burnout due to short circuits/high voltage
Connecting Ribs
Auxilary Switch
Auxillary Relay -30 A
TNC Switch
Trip Circuit Supervision Relay
Electronic Hooter/bell (Replacement)
Annunciator
Antipumping device
Transportation, Installation, testing and Commissioning of various 33 KV VCB Outdoor Type (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of 33 KV C &R Panel of 33 KV Feeder (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of 33 KV C &R Panel of 33/11 KV Power Transformer (Material to be supplied by department)
Replacement of Non-functional 33 KV Outdoor VCB with new one (Material to be supplied by the Department) (The Job includes Transportation, loading, unloading, etc)
Replacement of Non-functional/Defunct C&R Panel of 33 Kv feeder with new one (Material to be supplied by the Department) (The Job includes Transportation, loading, unloading, etc)
Replacement of Non-functional/Defunct C&R Panel of 33/11 KV Power Transformer with new one (Material to be supplied by the Department) (The Job includes Transportation, loading, unloading, etc)
Repairing of 33 KV C&R Panel of transformer
Replacement of Buchol Relay
Replacement of Winding Temperature Indicator
Replacement of Oil Temperature Indicator
Replacement of Master Tripping Relay
Replacement of Auxilliary Relays (3-element type)
Replacement of Closing Trip Switch
Replacement of Tripping/closing coils (Coils to be provided by the Contractor)
Re-wiring of Control Panel with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc in case of damaged of wiring
Deco Spray painting
MW Meter (Replacement)
Energy Meter (Replacement)
Electronic Hooter (Replacement)
HRC fuse with Base -1 Amps
HRC fuse with Base -6 Amps
HRC fuse with Base -16 Amps
LED panel Indicators
Push Button
Annunciator
O/C and E/F relay
Restricted E/F relay
33/11 KV Power Tranformer
Topping of oil including Trasportation from Divisional Store and other routine maintenance
Replacement of 33 KV Bushing including Trasportation
Replacement of 33 KV Bushing Rods including Trasportation
Replacement of 11 KV Bushing including Trasportation
Replacement of 11 KV Bushing Rods including Trasportation
Transportation, Installation and fixing of Bi-Metallic Clamps of Bush Rod
Tap Changer Contact replacement
Tap Changer Contact Repairs
replacement of old Gasket of Bushing (Material to be provided by the Contractor)
replacement of old Gasket of Tap changer(Material to provided by the Contractor)
replacement of old Gasket of Radiators/valves (Material to be provided by the Contractor)
Male contact (Replacement)
Female contact (Replacement)
Dehydration/Filteration of Power Transformer Oil
Winding Temperature Meter with Probe replacement
Repairing of leakage of radiators by way of gas welding
Trasportation and Replacement/Repairing of damaged cooling fans of radiators
replacement of Oil Temperature meter (OTA) (Material to be supplied by the Contractor)
Supply and Replacement of Silica gel (Material to be supplied by the Contractor)
Fresh earthing of transformer/different equipments (Plate Type, 600mm x 600mmx5mm GI, GI flat 50mm x 6mm x 6mm, GI Pipe 50mm dia(ISI marked), the earthing pit should not be less than 3 meters (The job include welding/bolting with the main earth mat)
Installation & commissioning of Power Transformer including assembly fixing of bushes, radiator ,fans(if any), wiring of instrument
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
33 KV isolator
Trasportation, Installation,Testing and Commissioning of 33 KV Isolator (Pipe type) without Earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60168 standard (Material to be supplied by department)
Trasportation, Installation,Testing and Commissioning of 33 KV Isolator (Pipe type) with Earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60168 standard (Material to be supplied by department)
Replacement of old damaged/defunctional of 33 KV Isolator (Pipe type) without Earthing blade with new one (Complete Job) conforming to IEC 60168 standard (Material to be supplied by department)
Replacement of old damaged/defunctional of 33 KV Isolator (Pipe type) with Earthing blade with new one (Complete Job) conforming to IEC 60168 standard (Material to be supplied by department)
Routine maintenace of 33 KV isolator (Pipe type) with earthing blade/without earthing blade
Repairing of 33 KV isolator
female contact
Copper pipe
33 KV Lightning Arrestor
Trasportation, Installation,Testing and Commissioning of 33 KV LA including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60099-4 standard (Material to be supplied by department)
Replacement of damaged 33 KV LA with new one (Material to be supplied by the department)
Eathing Mat
Measurement of earth resistivity, checking of electrical continuity of equipment earthing, tightning of earthing connectors,removal of rust from bolted earth connections and retightning
Installation, testing and commissioning of 2' x 10 mm Copper Bus Bar (Material to be supplied by department)
Transportation and Installation of Enclosure Box for Bus Bar (Material to be supplied by department)
Battery bank and Battery Charger of 36 V
Transportation, Installation, Testing and Commissioning of 36 V automatic battery charger with Float cum Boost Charger (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 200 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment conforming to IEC- 60896 standard (Material to be supplied by department)
Transportation, Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 100 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment conforming to IEC- 60896 standard (Material to be supplied by department)
Repair of Battery Charger of 36 V
Repair of Battery cell of 2V 100AH
Repair of Battery cell of 2V 200AH
Replacement of damaged 2V Battery Cell 100AH/200 AH
11 KV Power cables
Transportation, laying, Testing and Commissioning of 11 KV armoured XLPE power cable conforming to IS 7089(Part-II)-1895 by way of replacement and dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench making roll to safer sideoutside and carriage of same to store and laying in the power cable trench, peeling the cable , fixing the earth clamps and fitting the HS cable kit to both ends, fixing to panel and outgoing structure including testing and commissioning. (Material to be supplied by department)
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Replacement of 11 kv Damaged Cable kit
Transportation, Installation, testing and Commissioning of 11 KV , heat shrinkable cable kit Indoor type conforming to IS 13573/1993 with latest ammmentments if any by way of replacement and dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to panel and outgoing structure.complete job testing and commissioning. (Material to be supplied by department)
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Installation, testing and Commissioning of 11 KV , heat shrinkable cable kit outdoor type conforming to IS 13573/1993 with latest ammmentments if any by way of replacement and dismantling of damaged cable from the outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to outgoing structure.complete job testing and commissioning. (Material to be supplied by department)
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Laying and Fixing of 2-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 4-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 8-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 10-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Laying and Fixing of 12-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 (Material to be supplied by department)
Replacement of damaged 11 kv Post Insulator or providing additional post insulator (Material to be supplied by department)
Replacement of damaged busbar of single conductor of outdoor switch yard (Panther conductor) (Material to be supplied by department)
Replacement of damaged T-clamp/Pad clamp/PG clamp, etc
Routine maintenace of 33/11 KV outdoor switchyard
Replacement of damaged LED bulbs of control room building and switchyard lighting (Material to be supplied by department)
11KV Auxillary Transformer
Topping of oil (Material to be supplied by department)
Replacement of HT/LT bushing(Material to be supplied by department)
Replacement of HT/LT bush rods(Material to be supplied by department)
Replacement of HT/LT bushing gaskets(Material to be supplied by department)
Repair of Auxillary Transformer including dismantling and re-erection after reparing, transportation to the workshop at Phinter/Kathua (Reparing cost of the transformer to be paid by the department)
Installation of Auxillary Transformer (Material to be supplied by department)
Replacement of LT cable 3½ core 120mm² for auxillary transformer (Material to be supplied by department)
Dragging (upto avg. 50 mtr) and rotation if required of Power transformer 66/11 kv
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Loading of Power Transformer to Sub Station Bed/Platform
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Unloading of Power Transformer to Sub Station Bed/Platform
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Supply and installation of new outgoing structures on ST poles 9m with 11 KV isolator (600 Amp Pipe type, CPRI tested), LA Station type and other accessories including plate type earthing
Transportation and Installation/Testing and Commissioning of 11 KV Isolator, 800 A (with/without Earthing blade)conforming to IS 9921/IEC -129 601 standard (Material to be supplied by department)
Replacement of 11KV LA set (Material to be supplied by department)
Fencing of Switchyard with Mesh fencing 2 Mtr. High,angle iron post complete along with cement bottoming of angle posts (Material to be supplied by department)
Providing and fixing of damaged/broken windows panes with fibre sheet of control room
Deweeding of vegetation in outer yard
Removing of Stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation ,levelling of area with existing stone metal
Providing additional stone metal and its carriage and laying in outdoor yard
Repair and maintenance of AC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc including suppply of material.
Repair and maintenance of DC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc
Painting of internal/external walls and roof with approved brand of distemper , doors and window of control room buiding with paint of approved brand like asian paint,nerolac etc including suppply of material.
Fencing of Receiving Station with barbed wire 2 Mtrs High,angle iron post complete with 7 horizontal wires and 2 cross wires along with cement bottoming of angle posts including suppply of material.
Replacement of ceiling fan of control room building (Material to be supplied by the department)
Supply and Spray Painting of Power Transformers as per latest BIS
Supply and Spray Painting of outdoor breakers as per latest BIS
Supply and spray Painting of outdoor CT's as per latest BIS
Supply and Spray Painting of outdoor PT's as per latest BIS
Supply and Spray Painting of Control & Relay Panel as per latest BIS
Supply and Spray Painting of 10 MVA Power Transformer
Supply and Spray Painting of 6.3 MVA Power Transformer
Supply and Spray Painting of 3.15 MVA Power Transformer
Supply and Spray Painting of 1.6 MVA Power Transformer
Whitewashing of Control Room Buildings and Sub Divisional Office (Material to be supplied by the Department)
Cleaning of roof of Control room building as per PWD norms
Construction of foundation of different equipments like 33 KV CT's,33 KV PT's, 33 KV VCB, 33 KV Isolators, etc. (As per the PWD Norms)
Erection of structure of different equipment
Watering of earthing at different Receiving Stations
RAVISUN ELECTRICALS
Patiaya Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .