Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.7 L+₹9,058.57 (0.49%)Rejected-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.8 L+₹1.2 L (6.42%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹20.1 L+₹1.5 L (8.15%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
21 Feb 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
SPECIAL REPAIRS TO INTERNAL WIRING LIGHT FITTINGS MCBs DBs SERVICE CABLE AT NTG NLC PROVN OF GENERATOR SET 5 KVA LIGHTENING CONDUCTORS GEYSERS AND EXHAUST FANS AT BANSWADI PROVISION OF SPLIT TYPE ACs AND GEYSERS AT DIQA AND SQAE UNDER GE NORTH
2020_MES_319111_1
8426
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BANGALORE
Class E category b (i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹47,000
Yes
16 Mar 2020
28 Jan 2020
22 Feb 2020
28 Jan 2020
21 Feb 2020
10 Feb 2020
28 Jan 2020 - 9 Feb 2020
Amount
Taking down carefully aluminium/ copper wiring / power point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans, bell pushs, bells, regulators etc and making good the disturbed surface of walls, ceiling etc all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core PVC insulated, unsheathed, FRLS multi stranded copper conductor cable 1100 volts grade, conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade, including accessories surface / concealed type wiring run on walls / ceiling including modular terminal boxes of branded manufacturers, concealed mounted / on walls with white modular cover plate with frame of suitable module fixed with cadmium plated iron screws for housing the modular switches, switch socket outlets, fan regulators etc., including 1.5 sq.mm PVC insulated single core multi stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 1.02 above but for one fan point controlled by one switch.
All as per Sl Item No. 1.02 above but for one bell point controlled by one switch.
All as per Sl Item No. 1.02 above but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 1.02 above but for one 3 pin socket out let 5 Amps on same board with other switches.
Point wiring complete with 2.5 sq.mm single core PVC insulated, unsheathed, FRLS multi stranded copper conductor cable 1100 volts grade, conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade, including accessories surface / concealed type wiring run on walls / ceiling including modular terminal boxes of branded manufacturers, concealed mounted / on walls with white modular cover plate with frame of suitable module fixed with cadmium plated iron screws for housing the modular switches, switch socket outlets, fan regulators etc., including 2.5 sq.mm PVC insulated single core multi stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed FRLS multi stranded copper conductor cable 1100 volts grade conforming to IS 694 drawn through existing non-metalic rigid PVC conduit medium grade including modular terminal boxes of branded manufacturers concealed on walls with white modular cover with frame of suitable module fixed with cadmium plated iron screws for housing the modular switches, switch socket outlets, fan regulators etc., of 1.5 sq.mm PVC insulated, FRLS single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 1.08 above but for one fan point controlled by one switch.
All as per Sl Item No. 1.08 above but for one bell point controlled by one switch.
All as per Sl Item No. 1.08 above but for one 3 pin socket out let 5 Amps on independent board.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed FRLS multi stranded copper conductor cable, 1100 volts grade conforming to IS 694 drawn through and including non-metalic rigid PVC casing and capping with accessories surface typerun on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 2.5 sq.mm PVC insulated single core multi stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR SL ITEM NO. 1.02 to 1.12 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring.
Sub main wiring complete with two runs of 6 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade with one run of 6 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit medium grade with conduit accessories including taking down the existing all as specified and as directed. NOTE :- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit for payment purpose.
Sub main wiring complete with two runs of 6 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories including taking down the existing all as specified and as directed. NOTE :- Two runs of cable and one run of earth wire shall be measured as one unit for payment purpose.
LED batten suitable for indoor applications 18/20 Watts, 4 feet with aluminium housing & integrated LED channel with white arcylic cover complete with all accessories all as per Halonix Cat No. HLB-03-20-CW-AL or techno commercially equivalent models specified in PS including taking out old fittings all as specified and directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as per Halonix Cat No. HLB-03-10-CW-AL or techno commercially equivalent models specified in PS including taking out old fittings all as specified and directed.
LED building security light of protection IP -66, system wattage 30 Watt , CCT -5700 K , PF>0.9, etc complete including GI bracket of 1.0 mtr length made out of 40mm dia light grade GI pipe bend to shape, fitted at pole / building with suitable clamps, nuts, bolts and washers including connection with PVC sheathed cable of size 2.5 sq.mm, 3 core all accessories all as per Halonix Cat No. HLSLD-09-30-CWL-R or techno commercially equivalent models specified in PS including taking out old fittings all as specified and directed.
LED lamp of capacity 14/15 watt suitable to fit in angle holder all as specified and directed.
Surface mounted LED square luminaries suitable for indoor application of system wattage 18 /20 watt , CCT 6000 K, luminous efficiancy 100 Lm /watt , PF > 0.9 etc including electrical connecions from ceiling rose with 3 core 1.0 sq.mm PVC sheathed copper conductor cable all as per Halonix Cat No. HLDLS-S06-18-CW or techno commercially equivalent models specified in PS including taking out old fittings all as specified and directed.
Recess mounted LED Luminaire of size 2 'x 2' 36 Watts, white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories all as per Halonix Cat No. HLFPR22-05-36-CW-R or techno commercially equivalent models specified in PS including taking out old fittings all as specified and directed.
Modular switch one way, 6 Amps, one module all as specified and directed.
Bell push, Modular type, 5 Amps one module all as specified and directed.
Modular socket 6 Amps, 2/3 pin, combined two Module all as specified and directed.
Modular type switch 16 Amps two module complete all as specified and directed.
Modular socket 6 /16 Amps 2/3 pin combined two module all as specified and directed.
Lamp holder angular type, PVC / Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
Buzzer, Ding dong AC, 230 volts, single pole all as specified and directed.
Ceiling rose surface PVC/Polycarbonate, isolated body with three terminals all as specified and directed.
Vertical DB, VTPN with MCCB as incomer, 6 ways, double door with provision for TP MCCB 125 Amps, 16 KA as incomer, IP 43 protection, conforming to IS-13032, universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides all as per INDOASIAN OPTIPRO Cat No.811888 or techno commercially equivalent makes in Standard / Legrand/L&T all as specified and directed.
MCB DB, SPN 12 ways, double door, with 200 Amps rated busbar 240 Volts, AC, 50 Hz, IP-43 protection conforming to IS-13032, universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides all as per Indo Asian Optipro Cat No.8119807 or its equivalent in standard/Legrand /L&T all as specified and directed.
MCB DB, SPN 4 ways, double door with 200 Amps rated busbar 240 V, AC, 50 Hz, IP-43 protection conforming to IS-13032, universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides all as per Indo Asian Optipro Cat No.8119807 or its equivalent in standard/Legrand /L&T all as specified and directed.
MCB SPN 240 volts 32/40 Amps complete all as specified and as directed.
MCB single pole 240 volts 5 to 40 Amps complete all as specified and as directed
Taking down ceiling fan / exhaust fan care fully, by disconnecting all electrical connections, dismantling the blades, down rods depeosited the same to MES stores for carryng out repairs or otherwise all as specified and as directed.
Painting of ceiling fans complete, in situ with synthetic enamel paint by one coat of spray painting including filling cavities with filler, after cleaning all dust including writng the fan No etc all as specified and as directed.
Modular type stepped type electronic fan regulator 120 Watt, two module, fixed in repairs all as specified and directed.
Earthing complete with galavnized steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and including galvanized iron wire of 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washer etc made of galavnized iron connected to earthing test point through protection pipe light grade of 20 mm dia all as shown in electrical plate No 3 of SSR Part - I 2009 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C 1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B 1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe of 20 mm dia medium grade, wire mesh and lugs, including test point and cable connected with suitable size copper lugs complete all as specified and as directed.
Exhaust fan 300 mm sweep, heavy duty, metalic body, single phase, 230 Volts, 1400 RPM with louver shutter complete including cutting the existing stone wall, fixing the PVC hume pipe of suitable dia and length fixed inside , finishing properly to match with the exisiting surface, electrical connections from the ceiling rose to fan with three core 1.5 sq.mm sheathed wire including writing the fan no.all as specified and as directed.
Ceiling fan 5 star rated of sweep 1200 RPM including down rod without regulator including electrical connections from ceiling rose to fan motor with three core sheathed wire of suitable size including writing the fan no. all as specified and as directed.
Excavating in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for laying cables/poles etc., and getting out in hard/dense soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
Galvanised iron steel tube, light grade, 40 mm bore pipe with all fittings fixed complete on walls, poles, laid under floors or in trenches as cable protection including necessary clamps, bolts, nuts, etc., all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power LT UG cable with aluminium conductor 1100 volts (earthed) grade of cross sectional area 50 sq.mm 3.5 core including taking down the existing complete all as specified and as directed.
Horizontal trenchless bore drilling using mechanical pneumatic drilling equipment for passing and including provision of HDPE pipe of 80 mm dia suitable for 0.4 Mpa working pressure, as in hard standing, depth range not less than 0.75m and up to 1.0 m and making good to disturbed surface of road/hard standing path all as specified and as directed. NOTE:- unit rate deemed to be incl cost of deposit and taking permission from civil authorities.
Supply, Installation, testing and commissioning 5 KVA silent Diesel engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS : 10001/10002 and alternator as per IS:-13364 complete with foundation (As per OEM design),with AMF control panel with necessary meter and sound proof canopy as per CPCB norms including submission of IEM testing certificate of no load and load test at least 12 hrs complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, burired directly in ground (earth pit less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25 x4 mm as earthing lead by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified and as directed.
All as per Sl Item No. 1.49 above but using with copper plate 600 x 600 x 3.15 mm thick electrode and 20 x 3.15 mm copper strip as earthing lead.
Air termination, single pointed, copper rod 12 mm dia and 300 mm long all as specified and as directed.
Copper strip 20 x 3.15mm with saddles and fixing screws etc as in roof conductors and down conductors above ground level all as specified and as directed.
Test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos of 8mm dia 25 mm long hex.head screws all as specified and as directed.
XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq.mm, 4 core connected with suitable lugs with crimping tool all as specified and as directed.
Switch socket combination 5 Amps /16 Amps, 5 in 1 flush type with fuse & neon indicator all as specified and as directed.
Water heater storage and vertical type, 5 star rated, 230 Volts, 2000 Watts, 25 Litres capacity complete all as per Bajaj Cat pat No. CALDIA (150800) or techno commercially equivalent makes specfied in PS with hot and cold PVC connections (02 Nos) of suitable length complete all as specified and as directed.
15mm dia medium grade Galvanised steel tubing with all fittings and fixed to wall, ceiling or laid in floors etc complete all as directed.
Stop valves, 15mm bore fancy type, cast copper alloy chromium plated concealed type, screwed down, high pressure, with cructh or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
Bib taps, cast copper alloy, fancy type, chromium plated long body, 15mm dia with CP flange fixed with wall flange complete all as specified and as directed.
Cutting and screwing existing steel tubing for alternations or addition suitable for 15 mm dia GI pipe complete all as specified and as directed.
Switch piano flush type, single pole, one way, 5 Amps complete all as specified and as directed.
Ceiling rose, surface type bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed.
Supply, install and testing Hi wall split units indoor/outdoor 1.5 TR capacity, complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating and EER 3.2.complete all as specified and as directed.
Voltage stablizer for automatic operation, single phase, naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with out put voltage stabilized at 230 volts with accuracy + 2.5 % and capacity of 5 KVA complete all as specified and as directed.
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 32 Amps, 230 Volts AC complete all as specifeid and directed.
Sub main wiring complete with two runs of 6 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade with one run of 6 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit medium grade with conduit accessories all as specified and as directed. NOTE :- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit for payment purpose.
MCB DB, TPN 4 ways, double door vertical type, 415 volts with 200 Amps rated busbar for housing of MCCB incoming and MCBs outgoing complete all as specified and as directed.
MCCB 4 pole ,415 volts, 100 Amps, 16 KA complete all as specified and as directed.
Water heater storage and vertical type, 5 star rated, 230 Volts, 2000 Watts, 10 Litres capacity complete all as per Bajaj Cat pat No. 150754 or techno commercially equivalent makes specfied in PS with hot and cold PVC connections (02 Nos) of suitable length complete all as specified and as directed.
Metal clad plug and socket with two pin and earth single pole with 20 Amps MCB, 230 Volts AC complete all as specifeid and directed.
Sub main wiring complete with two runs of 4 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade with one run of 4 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit medium grade with conduit accessories all as specified and as directed. NOTE :- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit for payment purpose.
Vasavi Electricals
H S S ENGINEERS AND CONTRACTORS
RAMSON TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .