| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 CrAccepted-AOC STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹25.2 Cr Quoted ₹26.2 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹28.0 CrRejected-Finance | ₹28.0 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹28.8 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹28.8 Cr | L3 | Rejected-Finance Other than lowest |
Tender Value
₹23.5 Cr
EMD Value
₹15 L
Closing Date
24 Jun 2025, 6:00 pmClosed
Chief Engineer Bathinda Zone
Headquarters Chief Engineer Bathinda Zone Military Engineer Services PIN- 900484 C/o 56 APO
DEMOLITION AND RECONSTRUCTION OF BLDG NO P 9 TO P 14 SINGLE OR LIVING ACCN AT BIKANER MILITARY STATION
2025_MES_707153_1
84469 CE BTZ/BKN/TOKEN-06 OF 2025-26
Open Tender
Civil Works
365 days
GE (P) Bikaner
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (P) Bikaner
₹15 L
Yes
HQ Chief Engineer Bathinda Zone
26 Jul 2025
8 May 2025
26 Jun 2025
8 May 2025
24 Jun 2025
10 Jun 2025
8 May 2025 - 12 Jun 2025
22 May 2025
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Part - I
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Part - II
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Part - III
Lump sum price worked out by the tenderer for “ROAD, PATH AND CULVERT WORKS" as listed in Schedule ‘A’ Part - IV
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS" as listed in Schedule ‘A’ Part- V
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Part- VI
Lump sum price worked out by the tenderer for “SECURITY FENCING WORKS" as listed in Schedule ‘A’ Part - VII
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Part- VIII
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Part- IX
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES AND CENTRAL HOT WATER SUPPLY WORKS" as listed in Schedule ‘A’ Part - X
Lump sum price worked out by the tenderer for “DEMOLITION/DISMANTLING WORKS" as listed in Schedule ‘A’ Part - XI
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Part - XII
Sch 'A' Part- XIII, MISCELLANEOUS ITEMS
Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
-do- all as per srl No. 14 above but for one three pin switch socket outlet 5 Amps on the independant borad
-do- all as per srl No. 14 above but one three pin switch socket outlet 5 Amps on the same borad
-do- all as per srl No. 14 above but one light point controlled by two way switches
Material and labour for concealed Point wiring for one socket outlet 15/20 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate).
Supply only modular switch 6Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular switch 6Amps, piano flush type, single pole, two way complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular switch 16Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular socket outlet 2 in 1, 6Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular socket outlet 5 in 1, 16Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator (suitable properly match with the new BLDC fan), 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified and as directed by Engr-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Supply and fixing TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material flush/surface mounting with copper Bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, IP-54 protection and provision and including MCCB 4 pole 100 Amp, 16 KA as incomer and MCBs as outgoing, dust and vermin proof complete as per IEC 61439-3 complete all as specified and as directed by Engineer-in-charge. Note- MCB for outgoing shall be measured and paid seperately.
Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 40 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SP 6 to 32 Amp with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve complete all as specified and as directed by Engineer-in-charge.
Supply and fixing blanking plate of plastic suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for submain wiring comprising single core, 2 Runs of 4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 20mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) Aluminium housing & Integrated Electronic driver (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6500K (m) CRI : more than 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED tube light fitting polycarbonate housing 1 x 10 Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6500K (l) CRI : more than 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED lamp 1x9 watt including PVC holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by Engineer-in-Charge
Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED tube light fitting with inverter battery suitable for 20 watt, with backup of minimum 03 hours, autocut off feature at full charge, high lumen 100 lumen/watt complete fitting with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 40mm bore CPVC long handle valve complete all as specified and as directed by Engineer-in-charge.
Supply & fixing CP Bib tap fancy type long nose with wall flange, suitable for 15 mm bore pipe screwed both ends for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in- charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series).
Supply & fixing 15mm bore stop valves or angle cock, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in- charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series)
S&F 15mm bore two-way angle cock with flange chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions complete all as specified and as directed by Engineer-in- charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series)
S&F single lever concealed diverter incl bath spout & shower complete all as specified and as directed by Engineer-in- charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series)
Supply & fixing 15mm bore Pillar taps, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in- charge. (Make: Jaquar(continental series)/Hindware (contessa plus series)/Cera (ocean series)
Supply and fixing health faucet fancy type, brass CP including SS tube 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.
Supply, installing, commissioning and testing Water Cooler fully stainless steel (anti corrosive pre coated body), electric driven single phase having approx storage capacity of 40 Ltr and nominal cooling capacity of 40 Ltr per hour energy efficient compressor & Eco friendly refrigerant R-134a, with float valve and inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
S & F evaporative air coolers (desert coolers) as per IS 3315: 2019, minimum air capacities 4000 cum per hour, sump tank capacity 80 litres, cooling efficiency not less than 65%, maximum power consumption 280 watts, plastic body, noise level not more than 65 dBA at 1 m distance complete all as specified and as directed. Note: (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. (b) Serial Number as issued by Engr-In-Charge of cooler and GE Office name shall also be written on cooler with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with wall mounting bracket complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
(a) S & F split type Heat Pump water with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 1.5/2.0 HP, hermetically sealed with environmental friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 150 to 200 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 6.0 kW and rated power input of not more than 1.3 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre. Qty- 01 No. (b) S & F pressure pump having SS-304 impellers driven pump having flowof 5000 LPH and head to 30 mtr with all accessories coupled to motor. 1/3 phase 2900 RPM with 24ltrs of pressure vessel having working arrangement (1W). Qty- 01 Set. (c) S & F water heater, having capacity of 455 ltrs with blue diamond glass lined puff injected insulated tank having capacity of 455 ltrs, having glass coated electric heating elecments to avoid any scaling and 50 mm foam insulation. Heating tank should have the electrical elements of atleast 6 KW in total and should be glass lined. Qty- 01 Set. NOTE: (i) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (ii) Heat pump should have a user friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump.
M&L for 100mm thick moorum/bajri filling for road side berms spread and levelled and rammed including watering complete all as specified and as directed by Engineer-in-charge.
Supply and laying/fixing 60 mm thick (M-35 grade) precast interlocking tile/paving block factory casted using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
M&L for RCC Type B-1, 1:2:4 (using 20 mm graged crushed stone aggregate) as in drain wall and floor of any depth and width including necessary form work complete all as specified and directed. Note : Reinforcement bars shall be measured and paid separetly.
Supply and laying DWCPE (SN8) drain pipes 160 (OD)/150 mm nominal bore pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope including packing under and haunching against the side of pipe, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch
Supply and fixing factory made precast cover slab made of steel fibre reinforced concrete (SFRC), medium duty, 100 kN breaking load, in any shape and size (square /rectangular/ circular), 75 mm thickness, minimum M 30 grade of concrete, conforming to IS 12592: 2002 complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing DI fitting upto 150 mm bore pipe line (K-12), confirming to IS : 9523-2K, for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed by Engineer-in-Charge. Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer.
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Construction of brick masonary valve pit chamber size 45 X 45 X 70 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto 7.5 mtr length, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for boring of holes under main road pavement, hard standing or any other situation by manual mean for accommodate 40mm to 100mm bore GI tube (light grade) in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GI pipe and cable shall be measured and paid separately)
Supply and laying DWCPE (SN8) drain pipes outer dia 63 mm and inner dia 50 mm, as per IS-16098 (Part-II), laid in trenches for cable protection, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch
Supply and laying DWCPE (SN8) drain pipes outer dia 120 mm and inner dia 103 mm pipe as per IS-16098 (Part-II), laid in trenches for cable protection, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable tube rod removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable tube light fitting any type and wattage or CFL fittings anytype and wattage alongwith luminaries removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable DBs any type by necessary cutting, chases including disconnection of incoming and outgoing etc removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable MCCB/Isolator/MCBs etc removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable submain wiring etc removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable earthing anytype including earthwire etc removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable fan regulator etc removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable ceiling fan complete with blades, nut bolts, rubber reel, capacitor etc removing materials to AGE E/M store for keeping in safe custody complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable LT XLPE UG cable any size etc removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable CI pipe 150/100mm dia from trenches and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable CI fittigs 150/100mm dia from trenches and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable sluice valve 150 mm and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable GI tubing 80 mm from trenches/floor etc and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable gate valve 50mm from existing valve pit and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Taking down old unserviceable gate valve 25mm from existing valve pit and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Demolition of old unserviceable valve pit any size and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engineer-in- charge.
Subtotal
ASHISH JINDAL BUILDERS PVT. LTD. (BID ID -3326072)
SOOD ASSOCIATES PVT LTD (BID ID -3326437)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid