| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹40.8 LAccepted-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹41.6 L+₹77,774.60 (1.90%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹44.2 L+₹3.3 L (8.15%)Rejected-AOC | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹44.6 L+₹3.8 L (9.22%)Rejected-AOC QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹44.9 L+₹4.1 L (10.0%)Rejected-AOC | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
PROVN OF WEAKER SEC IN 02 ESH C VEHICLE SHED TILING SEPTIC TANK AND SOAKAGE WELL AT BIRPUR MIL STN UNDER GE KALUCHAK
2020_MES_405519_1
GE/KC/NIT-60/2020-21
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹90,000
Yes
25 Jan 2021
21 Dec 2020
20 Jan 2021
21 Dec 2020
18 Jan 2021
6 Jan 2021
21 Dec 2020 - 5 Jan 2021
60 days
Amount
Excavation over areas not exc. 1.5m deep in any type of soil and getting out, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Rough excavation n exc 1.50m deep and getting out in any type of soil, complete all as specified & directed.
Rough excavation exc 1.50m deep but not exc 3.0m deep and getting out in any type of soil, complete all as specified & directed.
PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footing; including attached pilasters and buttresses, complete all as specified & directed.
Use & waste of form work to sides of concrete foundation, footings, bases of columns, rafts and raft beamsand similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Demolition of brickwork or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
5mm thick rendering in cement mortar 1:4 over 10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective items.
Supply only integral water proofing compound, complete all as specifed & directed.
Mild steel framed work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified & directed.
Preparation of old decorated steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
6mm thick asbestos cement, corrugated or semi-corrugated sheeting in roof, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
Surface dressing n exc 15cm deep in any type of soil, complete all as specified & directed.
Cutting holes through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar exc. one brick wall and not exc. 2 brick walls built in cement mortar for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required, complete all as specified & directed.
Hard core of gauge n exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
100mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
100mm thick PCC 1:2:4, nominal mix, type B2, using 40mm graded crushed stone aggregate as in flooring, surface finished even and smooth without using extra cement, complete all as specified & directed.
PVC floor dividing strips, 1.5mm thick and 38mm wide, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint of any tint over a coat of primer, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, fixed in retaining wall for weep hole, complete all as specified & directed.
Boulder filling dry, handpacked tightly, as in wire crate apron bunds etc, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper over one coat of alkali-resistant priming paint, complete all as specified.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 200mm, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 150mm, complete all as specified & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:3:6 (Nominal mix) type C-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:3:6 (Nominal mix) type C-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including forming and filling of joints 12mm wide with bituminous filler, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective item.
Construction of soakage well 3.50 internal dia and 4.50m depth including excavation in any type of soil, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing brick honey comb/ solid brick masonry in cement 1:4, RCC (M-25 design mix) cover slab filled with brick bats including intercepting chamber screen chamber and disposal of soil, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5. Note : 1. During excavation if unexpected water is encountered, the same shall be bailed out / de-watered by the contractor mechanically or manually without any extra cost. 2. The excavated surplus soil shall be removed to a distance exceeding 500mtr and not exceeding 1500mtr and deposited where directed by the Engineer-in-Charge.
Construction of Septic Tank for 250 users including excavation in any type of soil, foundation in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) brick work in cement mortar 1:4, RCC (M-25 design Mix) slab including cast iron manhole cover having 6mm plate embedded all around with angle iron frame vent shaft etc, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Machine cut kota stone slab flooring, 20-25 mm thick as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 15mm screed layer in cement mortar 1:6, complete all as specified & directed.
Machine cut kota stone slab, 20-25 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:3, complete all as specified & directed.
100mm thick PCC 1:3:6 (nominal mix), type C-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
15mm thick rendering in cement mortar 1:6 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
Complete removal of existing treatment of any description by washing, rubbing down and stopping of distempered/painted wall surfaces and applying 2mm thick wall care putty primed with alkali resistant primer and painted with two coats of oil bound distemper, complete all as specified & directed.
Screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor finishes, complete all as specified & directed.
Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match, complete all as specified & directed.
75mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of cement base paint, complete all as specified & directed.
Preparation of old painted wooden or wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified & directed.
PCC 1:4:8 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
Rolled mild steel work in main and cross beams, hip and jack rafters; purlins where connected to comman rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel framed work as in plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Rolled mild steel work in roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel framed work as in plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long but n exc 50cm, diametre of neck in exc 12mm but n exc 20mm, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
75mm thick PCC 1:3:6 (nominal mix), type C-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
150mm thick PCC 1:2:4, nominal mix, type B2, using 40mm graded crushed stone aggregate as in floor etc, surface finished even and fair, laid in alternate bays including form work, complete all as specified & directed.
Forming Contraction (Dummy) joints 150mm deep x 10mm wide, filled with sealing compound grade ‘A’, complete all as specified & directed.
MAMTA ENTERPRISES
M/S Sudagar Mal
Hare krishna engineering const.
AJAY GANDOTRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .