The GM P and P PP
Office of the GM P and P PP
Overhauling of Boiler pressure parts of 250 MW thermal power plant of unit8
2025_DPL_841223_1
WBDPL/PP/T/GM(PP)- 12013(12)/14/2025/BMD/E/040
Open Tender
Miscellaneous Works
Item Rate
365 days
Office of the GM P and P PP
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹3.1 L
Office of the GM P and P PP
23 Jul 2025
2 May 2025
29 May 2025
2 May 2025
26 May 2025
6 May 2025
5 May 2025
Amount
(A)BOILER PRESSURE PART WORK:
Supply &Fitting of scaffolding at Furnace zone, PLSH By Couplok scaffolding.
Scaffolding of FSH, RH, LTSH & Economizer.
Cleaning of furnace (Boiler first pass), PLSH, FSH & RH zone by HP water jet.
Cleaning of LTSH, Economiser, Pent house including roof, roof top, inside pent house accumulated ash, Dog House, Dead chamber, all Boiler area Buck stay including duct area inside & outside.
Boiler External cleaning from pent house elevation to zero meters by air & fire water. (Upto Coal Feeder Building including fans duct,ccp APH)
Arrangement & Assistance for Furnace Gas tightness test.
Hanger & Supports checking of critical pipings including air and flue gas duct area up to ID Fan (excluding ESP) & Boiler Buck stay checking.
DE metering of pressure parts ,Area to be covered: Furnace tubes at soot blower, burner mouth area & gooseneck area, LTSH, Economiser, Steam cool wall, manhole areas, FSH, RH,Screen tubes etc.
a) Removal, fabrication & fitting of guard tube for Screen tube,scw, LTSH, Economiser, furnace wall.
b) Removal, fabrication & fitting of Cassette baffle for, LTSH, Economiser
Lifting & refitting of LTSH coil including terminal joints, and hanger tube joint.
DP test of stub joints
Insert in furnace wall tube.(including radiography)
Insert in LTSH ,Economiser,SCW tube. (including radiography)
Insert in FSH, PLSH, RH tube(including radiography)
Insert in screen tube (including radiography)
Deposition of weld metal on Boiler tubes, stubs, doors, headers etc.
Radiography of erection welding joints (single shot)
Skin casing welding.
Servicing for safety valves & Trevi test and actual popping of Drum-3, SH-2,RH-5 safety valves
Safety valve seat cutting
Servicing of soot blower safety valve.
Lifting & refitting of ECO coil including terminal joints
Stress relieving for pressure parts welding joint.
Roof loose tube proper clamping.
Fabrication of different size cold bends.
Economiser header stub joint replacement.
LTSH inlet header stub joint replacement.
Overhauling of Boiler Drum and drum internals.
Fins welding
Pressure parts area Miscellaneous job.
LTSH coil replacement.
Boiler Inspector Sundry expenses (other than fees)
MAGNETIC PARTICLE TEST (MPT)
Servicing of Man holes of boiler
Servicing of Peep holes of boiler
Hiring of reciprocating pump for departmental & inspector hydro test at 250kg/cm2
(B) INSPECTION & REPAIR OF PENT HOUSE, DEAD CHAMBER & DOG HOUSE:
Inspection & Repair of pent house, dead chamber & dog house.
(C1) HIGH PRESSURE VALVE SERVICING:
Overhauling of HP valve size above 25 mm & up to 50 mm (class 2500 & 3000)
Overhauling of HP valve size above 50 mm & up to 100 mm (class 2500 & 3000)
Overhauling of HP valve size above 100 mm & up to 200 mm (class 2500 & 3000)
Overhauling of HP valve size above 200 mm (class 2500 & 3000)
Overhauling of pneumatic operated Spray control valve
Overhauling of Manual Operated spray control valve
(C2) HP VALVE ACTUATOR CLEANING,GREASING & TIT-BIT MAINTENANCE:
Servicing of Valve Actuator, size up to 50mm
Servicing of Valve Actuator, size above 50mm &upto 200 mm
Servicing of Valve Actuator, size above 200mm &upto 350 mm
(D)REFRACTORY:
Removal re-application of refractory
(F) BURNER SYSTEM (COAL & OIL BURNERS, WIND BOX, SADC, BURNER TILT WORK,BURNER ISOLATING GATE)
Coal Burner Servicing/Replacement
Oil Burner servicing/ replacement
SADC, Burner tilt Servicing & Wind box repairing.
Burner Isolating gate servicing
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .