Loading…
Loading…
Tender Value
₹6.7 Cr
EMD Value
₹13.3 L
Closing Date
31 Aug 2026, 3:00 pm5d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
TRD
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments'' in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.Note: - As per JPO Note No. JBP/W/R/T-14 dated 16.09.2022 for tenders, a condition stating that "Non submission of Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet by the tenderer shall result in summarily rejection of his / their bid" shall be introduced and tender cases shall be dealt accordingly. However, cases may arrive such as the tenderer may have submitted Annexure VI B or Information in Similar format, but not audited balance sheets, or otherwise, or have submitted audited balance sheets for incomplete years, but not submitted information in Annexure VIB etc. in such cases, Tender committee may decide to ask for audited balance sheet or Information as per annexure VIB (as the case may be) from chartered accountant. If the information is not received timely, tender committee may deal the case accordingly.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (a) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (b) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (c) One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Note: -Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
1. "Tenderer should have experience on operation & maintenance of LV side voltage 25kV or above at substations/switching stations executed for Railways/Central/State Governments/or Central/State Government's PSUs." Or2. "Tenderer should have experience in erection, testing & commissioning/modification of traction substations/switching stations involving 25/33/66/132/220 KV or above. "Or3. Any work of augmentation of capacity of sub-station/ supply & erection of capacitor banks/ overhauling or repairing or rehabilitation or commissioning of PSI equipment /Traction Transformers/ Auxiliary Transformers/Circuit Breakers/ Interrupters/ Relays & control panels etc. with experience of executing works under power block in any railways which should include activities planned for execution of work.Or4. Combination of above 1 to 3.(Authority- WCR Electrical HQ letter No. WCR/L/03/2275 dated 09.07.2020).
5 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are instructed to kindly peruse the contents of attached document "Special Conditions of Letter of Credit as Mode of Payment" before exercising the option of payment through letter of credit as mode of payment.
(i)For participating in tender for an electrical nature of work, the contractor shall have to possess valid Electrical License of appropriate voltage issued by any State Government under clause 45 of compliance of rule of Indian Electricity rules 1956 or as amended from time to time. Electrifications of 11 KV and above including OHE, "A" class electrical contractor license is essential. (ii) The license can be possessed with one of the partners or in his own name if sole proprietor. Firm should submit a self-attested copy of the electrical contractor license along with the offer, otherwise, the offer will be summarily rejected.
Outsourcing of PSI Maintenance activities for 2 years over Jabalpur division.
JBP-TRD-Tender-2026-12~WCR
JBP-TRD-Tender-2026-12
Open
Works - General
24 Months
Jabalpur, Madhya Pradesh
₹0
₹13.3 L
7 Aug 2026
7 Aug 2026
17 Aug 2026
289 items across 7 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,54,36,925.62 | ||
| — | 560.00 | — | — | ||
| Maintenance of power transformer-Monthly. | — | — | — | 12,57,379.2 | |
| — | 56.00 | — | — | ||
| Maintenance of power transformer-Half yearly. | — | — | — | 1,56,796.64 | |
| — | 56.00 | — | — | ||
| Maintenance of power transformer-Yearly. | — | — | — | 2,45,140 | |
| — | 560.00 | — | — | ||
| Maintenance of HV CB-Monthly. | — | — | — | 2,97,102.4 | |
| — | 56.00 | — | — | ||
| Maintenance of HV CB-Half yearly. | — | — | — | 1,45,908 | |
| — | 56.00 | — | — | ||
| Maintenance of HV CB-Yearly. | — | — | — | 1,78,332.56 | |
| — | 112.00 | — | — | ||
| Maintenance of HV double pole isolator-Half yearly. | — | — | — | 1,42,969.12 | |
| — | 112.00 | — | — | ||
| Maintenance of HV double pole isolator-Yearly. | — | — | — | 2,15,303.2 | |
| — | 336.00 | — | — | ||
| Maintenance of HV CT-Quarterly. | — | — | — | 2,32,972.32 | |
| — | 112.00 | — | — | ||
| Maintenance of HV CT-Yearly. | — | — | — | 1,56,884 | |
| — | 112.00 | — | — | ||
| Maintenance of HV lightening arrestor-Yearly. | — | — | — | 1,56,884 | |
| — | 1620.00 | — | — | ||
| Maintenance of LV CB-Monthly. | — | — | — | 8,59,539.6 | |
| — | 162.00 | — | — | ||
| Maintenance of LV CB-Half yearly. | — | — | — | 1,87,596 | |
| — | 162.00 | — | — | ||
| Maintenance of LV CB-Yearly. | — | — | — | 4,22,091 | |
| — | 738.00 | — | — | ||
| Maintenance of LV CT-Quarterly. | — | — | — | 5,52,348.72 | |
| — | 246.00 | — | — | ||
| Maintenance of LV CT-Yearly. | — | — | — | 3,44,584.5 | |
| — | 106.00 | — | — | ||
| Maintenance of LV lightening arrestor-Yearly. | — | — | — | 92,158.52 | |
| — | 270.00 | — | — | ||
| Maintenance of 25 kV single pole isolator-Half yearly. | — | — | — | 3,44,657.7 | |
| — | 270.00 | — | — | ||
| Maintenance of 25 kV single pole isolator-Yearly. | — | — | — | 5,59,912.5 | |
| — | 354.00 | — | — | ||
| Maintenance of PT-Quarterly. | — | — | — | 2,45,452.98 | |
| — | 118.00 | — | — | ||
| Maintenance of PT-Yearly. | — | — | — | 1,65,288.5 | |
| — | 5060.00 | — | — | ||
| Maintenance of Interrupter (BM/BX)-Monthly. | — | — | — | 32,77,665.6 | |
| — | 506.00 | — | — | ||
| Maintenance of Interrupter (BM/BX)-Half yearly. | — | — | — | 5,85,948 | |
| — | 506.00 | — | — | ||
| Maintenance of Interrupter (BM/BX)-Yearly. | — | — | — | 13,18,383 | |
| — | 56.00 | — | — | ||
| Maintenance of capacitor bank including series reactors-Quarterly. | — | — | — | 68,901.28 | |
| — | 28.00 | — | — | ||
| Maintenance of capacitor bank including series reactors-Half yearly. | — | — | — | 78,398.32 | |
| — | 28.00 | — | — | ||
| Maintenance of capacitor bank including series reactors-Yearly. | — | — | — | 1,43,393.6 | |
| — | 2840.00 | — | — | ||
| Maintenance of 110V, 40Ah/150 Ah/200Ah lead acid battery & battery charger including DC distribution box-Fortnightly. | — | — | — | 24,00,680.4 | |
| — | 426.00 | — | — | ||
| Maintenance of 110V, 40Ah/150 Ah/200Ah lead acid battery & battery charger including DC distribution box-Quarterly. | — | — | — | 14,13,468 | |
| — | 142.00 | — | — | ||
| Maintenance of 110V, 40Ah/150 Ah/200Ah lead acid battery & battery charger including DC distribution box-Yearly. | — | — | — | 34,15,881 | |
| — | 28.00 | — | — | ||
| Yearly maintenance of buried rail system. | — | — | — | 7,83,719.72 | |
| — | 28.00 | — | — | ||
| Yearly maintenance of cable trench cleaning of TSS. | — | — | — | 2,35,238.36 | |
| — | 138.00 | — | — | ||
| Yearly gantry maintenance of TSS/SP/SSP. | — | — | — | 22,53,484.8 | |
| — | 138.00 | — | — | ||
| 100% extra for Yearly gantry maintenance under OHE block. | — | — | — | 22,53,484.8 | |
| — | 3058.00 | — | — | ||
| Yearly maintenance of earthing stations. | — | — | — | 8,14,773.52 | |
| — | 316.00 | — | — | ||
| Quarterly checking of hot spot by thermal imaging camera. | — | — | — | 3,86,727.12 | |
| — | 7176.00 | — | — | ||
| Housekeeping of TSS/SP/SSP/OHE-PSI Depot. | — | — | — | 46,02,758.16 | |
| — | 3352.00 | — | — | ||
| Quarterly maintenance of auxiliary transformer (5/10/25/50KVA). | — | — | — | 37,35,871.04 | |
| — | 1272.00 | — | — | ||
| Quarterly Maintenance of CLS panel. | — | — | — | 7,08,847.44 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocument2026-12PSImaintenance.pdf
ATTACHMENT
GCC-April-2022.pdf
ATTACHMENT
AdvancecorrectionslipNo1to10ofGCC2022_compressed.pdf Advance Correction Slip No 1 to 10
ATTACHMENT
AdvanceCorrectionSlipNo11toIRGCC2022_compressed1.pdf Advance Correction Slip No 11
ATTACHMENT
AdvancecorrectionslipNo1to10ofGCC2022_compressed.pdf
ATTACHMENT
AdvanceCorrectionSlipNo11toIRGCC2022_compressed1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].