Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.4 LAdmitted-Finance | -33.39% | ₹6.4 L | L1 | Admitted-Finance |
| 2 | L2₹8.0 L+₹1.6 L (24.8%)Admitted-Finance | -21.41% | ₹8.0 L+₹1.6 L (24.8%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | A.K.CONSTRUCTION CO. L1 | SOLAR WINGS TECHNOLOGIES L2 |
|---|---|---|---|---|---|
| 1.00 | (Non-Bsr)P&F top mounting circular ring made out from OEM fabricated hot dipped galvanised M.S.circular ring (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles in circle shape of 2 mtr length duly attached/welded with four nos. of support G.I. pipe of 48.3 mm dia to housing pipe made out of 88.9 mm dia 450 mm long G.I. pipe with 3 no. of tightning bolt. complete circular shape top ring bracket having arrangement to fix 6 nos. of LED flood light. | 3 | Each | 2,970 ₹8,910 Lowest | 18,000 ₹54,000 |
Tender Value
₹9.6 L
EMD Value
₹19,260
Closing Date
17 Aug 2026, 6:00 pmClosed
EXECUTIVE ENGINEER LIGHT
JAIPUR NAGAR NIGAM PANDIT DEENDAYAL UPPADHYAY BHAWAN LALKOTHI TONK ROAD JAIPUR
INSTALLATION OF 9 METER HIGH MAST LIGHT AT 1. SARANADUNGAR STAND NEAR TEJAJI TEMPLE, 2. BAWDI MAIN STAND, 3. MANSHARAMPURA MAIN STAND AND 16 METER HIGH MAST LIGHT AT 4. MANSHARAMPURA, NEAR SHRI GWALIA BABA TEMPLE. YEAR 2026-27
2026_DLB_584536_1
11 EXECUTIVE ENGINEER LIGHT
Open Tender
Electrical Works
Percentage
90 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹500
ONLINE PAY IN JAIPURMC WEBSITE
₹19,260
Yes
24 Aug 2026
8 Aug 2026
18 Aug 2026
8 Aug 2026
17 Aug 2026
8 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (63.1)Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | Set. | 3,734 | - |
| 2 | (53.1)Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 3 | (53.1.6)2 x 2.5 sq.mm | - | Mtr. | 63 | - |
| 4 | (42.32)SITC of Cutting back up surface up to 2 Mtr. Depth by digging by Bogie including all layers of crust for laying pipe line etc. and making good to original condition (excluding cost bitumen) | - | Mtr. | 428 | - |
| 5 | (60.2)Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 6 | (60.2.4)16.0 Sq. mm | - | - | - | - |
| 7 | (60.2.4.3)4 core | - | Mtr. | 238 | - |
| 8 | (55.1)Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 9 | (55.1.1)Single pole MCB (With B/C curve tripping Characteristics) | - | - | - | - |
| 10 | (55.1.1.2)6 A to 32 A rating | - | Each | 192 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
EPROC11XENLIGHT.pdf
Tender Documents • 4.96 MB
BOQ_1038306.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .