Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹16.9 L+₹9,468.99 (0.56%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹17.9 L+₹1.1 L (6.35%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹18.1 L+₹1.3 L (7.66%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹18.6 L+₹1.7 L (10.3%)Rejected-Finance 123 2 H 16 ACHARYA PRAFULLA CHANDRA ROAD MANICKTALLA KOLKATA WEST BENGAL 700006 | KOLKATA | WEST BENGAL | 700006 | 5 | Rejected-Finance Not L1 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Lucknow
229 MG Road
SPL REPAIR TO BLDG No P 07 AT USMAN ROAD UNDER GE WEST LUCKNOW
2022_MES_504612_2
CWE/LKO/W/T-76 OF 2021-2022
Open Tender
Civil Works
Item Rate
120 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE W LUCKNOW
₹42,000
Yes
22 Feb 2022
3 Feb 2022
18 Feb 2022
3 Feb 2022
17 Feb 2022
12 Feb 2022
60 days
Amount
M & L for moulded chequered cement concrete tiles 250mm x250mm x 10-12 mm thick,with grey cement and pigments set, jointed and pointed in neat cement slurry including 15 mm thick screed in CM 1:4 for receiving tiles complete all as specified and directed.
S&F in repair 'E' board 600x600x4mm thick white prelaminated reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick GS sheet and of size 24x32x300mm abd soaced at 1200mm centers securely fixed to be structural soffits by approved hangers at 1200 mm maximum centrers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug level and justers and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall, Flush fitting of 1200mm long cross tee (with double stiching) to be interlocked between main runners at 600mm center to from 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm dodules to be formed by fitting 600mm long cross tee centrally between the 1200mm cross tee. Tee, perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture insturction.Make-Everest/Diamond
M & L for 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 including demolition of existing brick work complete all as specified and directed.
M&L for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depression of scrapped surfaces with putty and applying two coats of oil bound distemper over and incl.1mm thick birla white wall care putty complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed.
M&L 3.5 mm thick aluminium composite panel (ACP) of any shade fixed with required EPDM rubber/snap beads and screws etc to aluminium frame work complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation and getting out in soft/loose soil etc. (including cutting of roads) or for shafts, wells, cesspits, manholes and sewage lines, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth complete all as specified and directed.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc including necessary formwork complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces, finished even and fair complete all speciified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc,complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and directed.
Removal of excavated soils to a distance not exceeding 50 metres and depositing where directed at a level n exc. 1.5 metre above the starting point complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub bases of floors and pavings etc. finished even and fair without using extra cement complete all as specified and directed.
M&L for Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
S & F for MS TMT bars 10 mm dia and over, cut to length, bent to shape required incl cranking bending spirally for hooping for column hooking ends and binding with and incl mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F for MS TMT bars 5mm to 10 mm dia and over , cut to length, bent to shape required incl cranking bending spirally for hooping for coloumn hooking ends and binding with and incl mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for form works rough finished surfaces of concrete side of concrete foundation, footing, bases of columns raft and raft beams sides and sofits if any of foundation and plinth beams and similar work flat ,vertical complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts ,columns etc complete all as specified and directed.
M&L for form work to sides and soffits of beams lintel band and the like complete all as specified and directed.
M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded stone agg) as in foundation, footings complete all as specified and directed.
M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded stone agg) in columns, pillars, piers, posts and struts etc complete all as specified and directed.
M & L for Reinforced cement concrete M-25 design mix (using 20 mm graded stone agg) in beam cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed.
S&F Framed work such as grills,gratings, etc.. with ends of shouldered and/or riveted,or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework or and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
S&F 1.25mm thick steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete push pull or manual type complete all as specified and directed.
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
M & L for preparation of new decorated surfaces of wall applying two coat of cement base paint over cement primer complete all speciified and directed.
M &L for preparation of steel surfaces of any description over 10cm in width or girth not otherwirse described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Material and labour 12mm thick toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required including patches fitting with floor door spring and long handle 2 Nos and locking device etc of make Ozone complete all as specified and directed.
M & L for cleaning of all loose dirt and dust from roof surfaces including taking down existing roof treatment and applying roof treatment as under (a) 10 mm thick plastering in CM (1:3) using 100 % coarse sand on roof / parapet walls with WPC @ 3 % by weight of cement. (b) Applying a coat of bitumenous primer conforming to IS-3384-1986 @ 0.40 ltrs/Sqm on prepared surfaces and allow to dry. (c) Supply and laying of 3mm thick (Minimum) polymeric water proofing membrane weighing not less than 3 Kgs/Sqm. (d) Appling one coat of aluminium paint over top laid polymeric surfaces. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed to be included in the quoted rates.
Taking down carefullycopper/aluminium point wiring (light, fan, socket or power) complete with fitting such as switches, sockets ceiling rose sketch light fittings etc, and making good the disturbed surface of walls and floors etc as directed.
M & L for following point wiring complete with 1.5 sqmm PVC insulated stranded copper conductor single core FRLS cable drawn through and including rigid non metalic PVC conduit 20 mm dia, ISI marked with concealed conduit wiring including cutting chases and making surface good to match, pressed steel terminal boxes not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer, plastic laminated top sheet cover 3 mm thick of required size and colour for housing switches and sockets, 1.5 sqmm PVC insulated (green insulation) copper conductor earth continuity FRLS cable drawn with wiring and connected to common earth dolly complete all as specified and directed.
One light/fan point controlled by one switch
One socket outlet point 5 Amp on an independent board
One socket outlet point 5 Amp on the same board
All as per item 34 here in before but using 2.5 Sq mm PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board.
S&F switch piano flush button single pole one way 5 Amp 240 volt complete all as specified and directed.
The same as item 36 here in before but using 15 Amps.
S & F socket outlet flush type multipurpose 2 in 1 , 3 pin 5 and 15 Amp, 230 volts complete all as specified and directed.
S & F socket outlet flush type 5 pin 5 Amps 240 volts complete all as specified and directed.
S & F ceiling rose surface bakelight two to three terminal complete all as specified and directed.
S&F fan regulator electronic, step up socket type, 230 volt and conection complete all as specified and directed.
Supply and Fixing wall/surface mounting luminaires integrated LED Batten 20 W, 6000 K,100 lumens/watt, 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements all as specified and directed. Make Phillips Smart brite cat no BN 021 LED 22S 6500 PSU GR/SI or Havells Endura linear neo cat no enduralinear neo BS22WLED865SPCWH/ Bajaj LED batten BCLAB 20W WH LED P
S&F in repairs of recess mounting type square/ round LED 12W, 3000/6000 K, downlighter all as specified and directed. Make:- Havells/ Philips/ Bajaj
S&F in repair super bright LED (2X2), 34/36/42 W, warm light 3000/4000 K recess mounting with high efficient LED source all as specified and directed.Make Philips cat part no.: RC383B LED36S 4000 PSU OD WHPIR/Havells Pluto Neo Panel cat no PLUTONEO2X2PLR34WLED840S/ Bajaj SKYLUX GZI SERIES -RECESSED cat no BZRSQL 36W GZINW
S&F 70 W flood light LED fitting Warm/day cool as required, IP 65 protection with high power LED complete with including provn of flexible three core cable from ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts and bolt complete all as specified and directed . Make: HAVELLS Jeta quanto plus with cat Part No. JETAQUANTOPLUSFLP30WLED757SYMLENS/ C&S Orion 1.0 with cat Part No.(LTEFI 30W HP LED)/ PHILIPS (ESSENTIAL SMARTBRIGHT FLOOD) with cat Part No. BVP161LED30CW/NW/WW PC WB
Supply and fixing modular type power unit with socket plug top and MCBs with four pin and one pin for earth plug and socket complete with and including one single pole MCB 20 Amp complete all as specified and directed. Make:- Havells/C & S/ Legrand.
S&F in repairs double door VTPN 4 way suitable for 4 pole MCCB 63-100A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated busbar, inter connection link, cable ties, earth bar etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and directed. Make: Legrand/Hager/Schneider Note: MCCB & MCB to be measured and paid seprately under respective items.
S&F in repairs MCCB 63-100 Amps 415 volts, 4 pole 16 KA breaking capacity complete all as specified and directed. Make: Legrand/Hager/Schneider
S&F in replacement sheet metal enclosure for DB’s when MCB, to be used, SPN,12 ways 240 volt with 200 Amps rated bus bar made out of 16 Gauge sheet steel double door complete all as specified. Make: Legrand/Hager/Schneider.
S&F MCB SPN 40 to 63 Amp 240 volts 10 KA breaking capacity complete all as specified and directed. Make: Legrand/Hager/Schneider
S&F MCB SP 6 to 32 Amp 240 volts 10 KA breaking capacity complete all as specified and directed.
M&L for two single core PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit complete all as specified and directed. (PVC Conduit and accessories shall be deemed to be included in the quoted rate)
M&L for two single core PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6.0 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit complete all as specified and directed. (PVC Conduit and accessories shall be deemed to be included in the quoted rate)
M & L of Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 print and as directed.
M/S Reliance Construction
M/S KAUSHIK CONSTRUCTION
M/S S.B. Singh and Sons
S S TRADING CO
M/S SWATI CONSTRUCTION
M/S S S A ASSOCIATES
acchyut trading company
Sanjay Traders
M/S S&R Construction
M/s Vatsh Raj and co
Spectrum Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .