| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ok |
| 2 | Accepted-Technical | Accepted-Technical ok |
Tender Value
₹29.4 L
EMD Value
₹58,800
Closing Date
13 Jul 2026, 2:00 pmClosed
XEN Electrical Division No. 1 Shimla
The Executive Engineer Electrical Division No-I, HPPWD, Kasumpti, Shimla-
Construction of Indoor Auditorium Building at Nahan, District Sirmour HP SH Providing 70 KW Solar Photovoltaic power Plant thereof
2026_PWD_137843_1
Electrical Division-I dated 01.07.2026
Open Tender
Electrical Works
Percentage
180 days
SHIMLA
As per bidding Document
12 documents required · 12 mandatory
₹1,500
₹58,800
12 Aug 2026
1 Jul 2026
14 Jul 2026
1 Jul 2026
13 Jul 2026
1 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,installation,testing and commissioning of on grid solar photovoltaic power plant conforming to MNRE specifications as amended, consisting of Mono/ Polycrystalline silicon solar cells, net metering facility necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required. | 70,000 | Per Watts | 42 | ₹29,40,000 |
| 1.01 | Solar Photovoltaic Module of capacity 330Wp or above,manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%.PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity,which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. | - | - | - | - |
| 1.02 | Power Conditioning Unit (PCU) of 350-800 V DC input voltage range and 400 V AC, threephase, 4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%,total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid voltage frequency. | - | - | - | - |
| 1.03 | Data Monitoring system complete with accessories. | - | - | - | - |
| 1.04 | Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands,lugs and other accessories etc. as required. | - | - | - | - |
| 1.05 | Lightning and surge voltage protection. | - | - | - | - |
| 1.06 | Connections & inter connections by supplying & fixing required size XLPE insulated copper conducter 1.1 KV grade armoured power and control cables between solar modules,main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc as required. | - | - | - | - |
| - | Conditions:- | - | - | - | - |
| - | The work shall be carried out according to CPWD General Specifications. | - | - | - | - |
| - | The work shall be completed to the entire satisfaction of the Engineer-in-charge. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.46 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.80 MB
BOQ_204063.xls
BOQ • 0.31 MB
DeclarationNEW.pdf
Additional Documents • 0.01 MB
SBD_1_70KVASolarAuditoriam.pdf
Tender Documents • 3.93 MB
Corrigen07.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .