Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-Finance PLOT NO 2 NH 2 NEAR HOTEL ZURICH VILLAGE AGWANPUR OPP DIMOND GROUP CNG PUMP DISTRICT PALWAL HARYANA | PALWAL | PALWAL | HARYANA | L1 | Accepted-Finance Due to higher rates | |
| 2 | L2₹48.2 L+₹6.2 L (14.7%)Rejected-Finance NEAR GONDA RAM CHOWK WARD NO 076 122107 | FARRUKHNAGAR | GURUGRAM | HARYANA | 122107 | L2 | Rejected-Finance Due to higher rates | |
| 3 | L3₹48.5 L+₹6.5 L (15.5%)Rejected-Finance | L3 | Rejected-Finance Due to higher rates | |
| 4 | L4₹50.8 L+₹8.8 L (20.9%)Rejected-Finance C 57A SURYA VIHAR GURUGRAM 122 001 HR | GURUGRAM | HARYANA | 122001 | L4 | Rejected-Finance Due to higher rates | |
| 5 | L5₹59.8 L+₹17.8 L (42.4%)Rejected-Finance | L5 | Rejected-Finance Due to higher rates |
Tender Value
₹57.5 L
EMD Value
₹1.2 L
Closing Date
5 Apr 2022, 5:00 pmClosed
Executive Engineer, Nuh
Executive Engineer, Provincial Division, PWD BNR Branch, Nuh
Construction of road from HNPP road (Jaisinghpur Chowki) to Higher Secondary School at village Chilawali to in Nuh District.
2022_HRY_213911_1
PWD/Nuh/Road/Chilawali/School
Open Tender
Civil Works - Roads
Works
90 days
Nuh
As per bid document
3 documents required · 3 mandatory
₹5,000
Yes
₹1.2 L
Yes
Executive Engineer, Nuh
22 May 2022
22 Mar 2022
6 Apr 2022
22 Mar 2022
5 Apr 2022
22 Mar 2022
28 Mar 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a ead of 50 m. (HSR 4.14.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – C C 1 : 1½: 3 ( 1 Cement: 1 ½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.1.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - C C 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-III) : 8 graded cum stone aggregate 40 mm nominal size). (HSR 6.1.6)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – CC 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). (HSR 6.1.7)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement – CC 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). (HSR 6.14.1)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.15.1)
Centering and shuttering including strutting, propping etc. and removal of form for- Suspended floors, roofs, landings, balconies and access platform. (HSR 6.30.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500 D or more (HSR 6.33.6)
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand). (HSR 7.21.1)
Providing and laying of brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1 :4 ( 1 cement : 4 coarse sand). (HSR 10.33.1)
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (HSR 11.25.1)
Construction of Embankment CBR 8% (for new road) with approved material obtained from borrow pits, including compensation of earth, with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2, as per technical clause 305 of MORT&H specifications. At no place top of sub grade of road shall not be less than 0.90 m above adjoining NSL. NSL for a block of 100m will be worked as mean of 6 levels taken on 20 m center to center length of road. These six levels are at three location on both side one at edge ROW. Other at 5 m and 10 m away from ROW. (Based on HSR 17.6) Note: In case the quantity of earth work calculated with NSL and finished level found to be less than 968.66 cum. Then actual quantity (less than 968.66 cum) will be paid. In case quantity worked out is more than 968.66 cum, then only 968.66 cum will be paid. Excess quantity shall be incidental to work and nothing extra will be paid. Further it shall be ensured that atleast 500 mm of sub grade with earth of CBR 8% shall be constructed at each location. Wherever any cutting of existing subgrade is required on this account excavation as well as handling and disposal of earthwork to accommodate minimum 500mm thick subgrade of minimum 8% CBR shall be carried out by the agency at his own cost. Nothing extra will be paid on this account. Before start of work, L-section shall be got approved from the employer with respect to GTS. However, typical X-section attached at section 5 of DNIT. Note:-No earth work will be allowed to be taken from PWD B&R/ ROW except for surplus earth after approval from Engineer.
Providing & laying 150 mm Granular Sub-Base with Coarse Graded Material - Grading-I (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORT&H specifications. Grading I material (Based on HSR 17.15.1) Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by the engineer.
Providing, laying WBM (G-I) (63 mm to 45 mm with screening Type “A” 75 mm each layer) , spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (Based on HSR 17.23.2) Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by the engineer.
Providing, laying WBM (G-II) (53 mm to 22.4 mm with screening Type “B” 75 mm each layer) , spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (Based on HSR 17.23.2) Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by the engineer.
Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. (HSR 17.69.2)
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand (zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.39.1)
Providing and fixing up to floor four level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) (HSR 6.38.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer. (HSR 11.67.1)
Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work. (HSR 11.71.1)
The Mahi Coop. L and C Society Ltd.
M/s Royale Infratech
SHAURYA CONSTRUCTION
MS Construction Co.
SK Trading Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .