Amount
Waterproofing Work & Expansion Joint Work
Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, having 80% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and as per direction of Engineer-in-Charge.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under: Joint strength in longitudinal andtransverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: (with 5 years service guarantee).
Removal of old Tarfelt i/c disposal as directed by Engineer in charge irrespective of lead and lift to the approved municipal dumping ground outside university premises.
Dismantling tiled roofing with battens boarding etc. complete including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead
Providing and fixing on roof pressed clay tile (Mangalore tile) 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete
P/L on roof pressed clay tile ridge (mangalor tile) 20mm nominal thickness and of approved pattern on steel frame work complete
fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.
Providing and fixing in position bitumen impregnated fibre board conforming to IS:1838 including cost of primer, sealingcompound in expansion joints.
Providing and filling gap in expansion joint between RCC/ Stone/Ceramic tiles/Granite/Marble by providing silicon sealant over backer rod of approved quality weather sealant as per drawing and direction of engineer in charge up to 25mm width & 12 mm depth.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around.
Providing and fixing sheet covering over expansion joints with iron screws as per design. 200mm wide.
Providing and Fixing of sky lights consisting of Multi cell/tight cell Polycarbonate Panel System of approved colour, 16 mm thick (minimum) having uniform in color with an integral Tight-Cell core constructed not to exceed 4mmx4mm in a cross section, Vertical Standing Seam manufactured at both sides of the panel. Snap-on connector to interlock the panels shall have a grip- lock double tooth locking mechanism to ensure maximum uplift capabilityand shall be of same color as that of panel.Panel shall be factory sealed/end welded panels with additional End?cap/Aluminium U- Profile (mill finish) for ends. Panel shall be co-extruded with special anti- glare compound and UV protected. The full system shall be fitted on MS purlins perpendicular to direction of sheeting with purlin spacing as specified by Manufacturer. The rate includes cost of all the operations, labour and all materials and tests (as applicable) involved such as bolts nuts and screws etc. and labour for cutting bending to required profile, necessary scaffolding, hoisting in position etc. for proper completion of the work etc. complete as per specification drawings and direction of Engineer in charge. Finished surface area of roofing fixed over steel tubular structure shall be measured for payment. 10mm thick
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials to the approved municipal dumping ground outside the premises as directed by EnC
Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent waterabsorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 50 mm thick.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .