Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 01 BOKAKHAT UDAYNAGAR GOLAGHAT ASSAM 785612 | GOLAGHAT | ASSAM | 785612 | Admitted-Finance |
| 2 | Admitted-Finance WARD NO 2 KALYANPUR CNB COLLEGE ROAD BOKAKHAT GOLAGHAT ASSAM 785612 | GOLAGHAT | ASSAM | 785612 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 131 JANGALPUR ROAD AIRPORT GATE NO 3 3 NO MOTILAL COLONY 24 PARGANAS N KOLKATA 700081 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700081 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
14 Aug 2024, 11:00 amClosed
Sarmistha Dutta 9435152517
Numaligarh Refinery Limited
Electrical Renovation Job of Warehouse Building at NRL Site
2024_NRL_819400_1
OC17000183/SAR
Open Tender
Electrical Works
Works
365 days
Numaligarh Refinery Limited
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹96,000
Yes
4 Oct 2024
1 Aug 2024
15 Aug 2024
1 Aug 2024
14 Aug 2024
1 Aug 2024
Amount
MCCB , MCB and DBs
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required -100 A,30KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required -125 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required -250 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required -250 A,50KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, in bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 6way,Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 8 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. : Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. : Single pole and neutral
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required : Double pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required : Triple pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required : 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required : 63 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 40 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.: 63 A
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
ITC of Exhaust Fans
ITC of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. : Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supply of Flood Lights (Kindly refer SOR for detailed description)
LED High Bay Light ,100 Watt
LED Flood Light , 100 Watt
Non-FLP/WP Well Glass LED Luminaire with ceiling mounted clamp (Kindly refer SOR for detailed description)
SITC of Electrical Panels
Supply of Type-1 Feeder Pillar. For detailed specification kindly refer Annexure-1
Installation, testing and commissioning of feeder pillars including all civil works for foundation(M20 grade) required for placing the feeder pillar, two nos of earthing, etc.
Steel structure jobs
Supply, fabrication and installation of MS base frames, supports for switchgear, and brackets for miscellaneous electrical equipment, cable and cable tray support out of rolled MS sections, pipes, plates etc. including shot blasting, welding, bolting, riveting, supply of necessary anchor bolts and grouting etc., supply of paint and applying one coat of anti-rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. Drawings will be provided after site handover after PO placement. (Any item weighing up to 1 kg. or less shall neither be measured nor paid).
Earth Pit ( Kindly refer SOR for detailed description)
Earth Pit & GI Pipe Electrode
Wiring and Earth Strip ( Kindly refer SOR for detailed description)
Wiring for light nos/ fan nos/ exhaust f
2X4sqmm FRLS PVC IC condtr
2X2.5sqmm + 1X2.5sqmm earth wire
2X4sqmm + 1X4sqmm earth wire
2X6sqmm + 1X6sqmm earth wire
SF 25mm PVC conduit
SF 32mm PVC conduit
SF 40mm PVC conduit
DLP Trunking
10 SWG GI Wire-Supply
8 SWG GI Wire- Supply
25 x 6 mm earth strip laying
10SWG GI-Wire Laying
8SWG GI-Wire Laying
Painting & Letter Writing
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: one or more coats on old work
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/steel works
Letter writing, number writing & marking direction of flow in equipment, panels and any other locations of various sizes(48",32",20",18", 16",12'',10",8", 4'' & 2" etc) with enamel paint as directed by EIC including supply of enamel paints and arrangement of scaffolding as required.
Supply and application of approved high quality enamel painting(double coating),preparation of surfaces as specified including rubbed down, touchup of primer or scrapping wherever required including tools and tackles, PPEs for safe work and supervision etc to complete the work in all respect as per specifications , drawings & direction of EIC.
Supply of Junction Boxes ( Kindly refer SOR for detailed description)
TPN JB : 310mm(L)x210mm(W)x116mm(D)
TPN JB : 200mm(L)x160mm(W)x116mm(D)
SITC of Area & Boundary Lighting ( Kindly refer SOR for detailed description)
Supply of 9M Octagonal pole
Supply of 1 M Standard DA(Double arm)
Supply of 1 M Standard SA(Single arm)
LED street light 72 to 75 watt
ITC of street light pole
M/S Nityananda Borah
LAHON BANIJYIK ENTERPRISE
BRAHMAPUTRA ENGINEERING AND INFRASTRUCTURE PRIVATE LIMITED
B.R.Construction
MAHESH KUMAR GULATI
EASTERN POWER ENGINEERING
Break Magnate
M/S N K CONSTRUCTION
OM ENTERPRISE
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .