Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
20 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR/MAINT OF OVER HEAD LT LINES TO UG CABLE AT GURDEEP ENCLAVE AND NEARBY OFFICERS QUARTERS AREA AT FARIDKOT MIL STN
2025_MES_732144_1
CA NO CWE SGNR/TOKEN-69 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE FARIDKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE FARIDKOT
₹1 L
Yes
22 Sept 2025
22 Sept 2025
21 Oct 2025
22 Sept 2025
20 Oct 2025
6 Oct 2025
Supply and laying XLPE insulated armoured heavy duty electric cable 400 Sqmm 3.5 core with aluminium conductor Multi standard cable 1100 volts grade in trenches ducts, pipe on walls, poles complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 240 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 185 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 150 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 70 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 50 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 35 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 25 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 01 here-in-before but 16 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, install testing and commissioning CPRI approved weather and vermin proof LT feedar pillar box ACB 630A factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all as specified and directed and consisiting of following :- (a) Aluminium bus bar of 600 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) MCCB 400 Amps 4 Pole 50 KA, 415 V - 01 No. for incoming. (c) MCCB 315 Amps 4 Pole 50 KA, 415 V - outgoing (d) MCCB 250 Amps 36 KA, 415 V - 02 for outgoing . (e) Street light timer with contactors- 01 set (f) Digital mutifunction meter for indicating of current, voltage with necessary CTs etc - 01 No (g) LED type indicator lamp Red/Yellow/Blue colour-01 set (h) Necessary internal wiring with copper conductor incl lugs and thimbles.
Supply, install testing and commissioning CPRI approved weather and vermin proof LT feedar pillar box (Panel board) factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all specified and directed and consisiting of following :- (a) Aluminium bus bar of 400 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) MCCB 315 Amps 4 Pole 36 KA, 415 V - 01 No for incoming. (c) MCCB 63 Amps 4 pole16 KA, 415 V - 12 for outgoing . (d) SPN 40 Amp 10 KA 415 Volt 4 Pole -02 Nos (e) 3 phase digital timer switch with contactors for auto switch on-off of street lights- 01 Set (f) Digital mutifunction meter for indicating of current, voltage etc with necessary CTs - 01 No (g) LED type indicator lamp Red/Yellow/Blue colour-01 set (h) Necessary internal wiring with copper conductor incl lugs and thimbles.
Supply, install testing and commissioning CPRI approve dweather and vermin proof LT feedar pillar box (Panel board) factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all specified and directed and consisiting of following :- (a) Aluminium bus bar of 500 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) MCCB 250 Amps 4 Pole 36 KA, 415 V - 01 No for incoming. (c) MCCB 63 Amps 4 pole 16 KA, 415 V - 8 for outgoing 01 Spare (d) SPN 40 Amp 10 KA 415 Volt 4 Pole -02 Nos (e) 3 phase digital timer switch with contactors for auto switch on-off of street lights- 01 Set (f) Digital mutifunction meter for indicating of current, voltage etc with necessary CTs - 01 No (g) LED type indicator lamp Red/Yellow/Blue colour-01 set (h) Necessary internal wiring with copper conductor incl lugs and thimbles.
Supply, install testing and commissioning CPRI approved weather and vermin proof LT feedar pillar box (Panel board) factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all specified and directed and consisiting of following :- (a) Aluminium bus bar of 600 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps for incoming. (c) MCCB 630 Amps 4 Pole 36 KA, 415 V - 01 No for outgoing . (d) MCCB 315 Amps 4 Pole 36 KA, 415 V - 01 No for outgoing . (e) MCCB 100 Amps 4 pole 16 KA, 415 V - 04 for outgoing . (f) Digital mutifunction meter for indicating of current, voltage etc with necessary CTs - 01 No (g) LED type indicator lamp Red/Yellow/Blue colour-01 set (h) Necessary internal wiring with copper conductor incl lugs and thimbles.
Supply, install testing and commissioning weather and vermin proof LT feedar pillar box (Panel board) factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all as specified and directed and consisiting of following :- (a) Aluminium bus bar of 450 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) MCCB 315 Amps 4 Pole 35 KA, 415 V - 01 No. for incoming. (c) MCCB 160 Amps 25 KA, 415 V - 04 for outgoing . (d) MCCB 63 Amps 16 KA, 415 V - 05 for outgoing (e) SPN 40 Amp 10 KA 415 Volt 4 Pole -02 Nos (f) 3 phase digital timer switch with contactors for auto switch on-off of street lights- 01 Set (g) Digital mutifunction meter for indicating of current, voltage etc with necessary CTs - 01 No (h) LED type indicator lamp Red/Yellow/Blue colour-01 set (j) Necessary internal wiring with copper conductor incl lugs and thimbles.
Supply, install testing and commissioning weather and vermin proof LT feedar pillar box ACB 630 Amp factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all as specified and directed and consisiting of following :- (a) Aluminium bus bar of 600 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) MCCB 630 Amps 4 Pole 35 KA, 415 V - 01 No. for incoming. (c) MCCB 315 Amps 35 KA, 415 V - 01 for outgoing (d) MCCB 63 Amps 16 KA, 415 V - 11 for outgoing. (e) SPN 40 Amp 10 KA 415 Volt 4 Pole -02 Nos (f) 3 phase digital timer switch with contactors for auto switch on-off of street lights- 01 Set (g) Digital mutifunction meter for indicating of current, voltage etc with necessary CTs - 01 No (h) LED type indicator lamp Red/Yellow/Blue colour-01 set (j) Necessary internal wiring with copper conductor incl lugs and thimbles.
Supply, install testing and commissioning weather and vermin proof LT feedar pillar box (Panel board) factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand stand of height not less then 2.5 Feet from AGL with earth work PCC fountation and other connected items complete all as specified and directed and consisiting of following :- (a) Aluminium bus bar of 450 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator (b) MCCB 315 Amps 4 Pole 36 KA, 415 V - 01 No. for incoming. (c) MCCB 63 Amps 25 KA, 415 V - 9 for outgoing . (d) SPN 40 Amp 10 KA 415 Volt 4 Pole -02 Nos (e) 3 phase digital timer switch with contactors for auto switch on-off of street lights- 01 Set (f) Digital mutifunction meter for indicating of current, voltage etc with necessary CTs - 01 No (g) LED type indicator lamp Red/Yellow/Blue colour-01 set (h) Necessary internal wiring with copper conductor incl lugs and thimbles.
Each Job
Taking down/ out unserviceable UG Cables of any cross sectional area of any descriptions, laid in trenches and/or fixing with walls/poles complete all as specified and directed.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of LT any size and setting a side complete all as specified and as directed.
Dismantling/ taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed.
Dismantling insulators any type, any size complete all as specified & directed.
S&F in repair of factory made epoxy polyester powder coated distribution board VTPN 4 way (MCCB DB) double door (IP-43 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for TPN as incommer and outgoing MCBs as required at site complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed. NOTE :- (a) MCCB and MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply and fix in replacement of unserviceable MCCB 63 Amp 4 pole 16 KA 415 volts, Fixed thermal and fixed magnetic release setting complete all as specified and directed.
S&F in repair of MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying pipes and getting out in soft/loosse soil all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified and directed.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 77 mm, minimum inside dia 63 mm conforming to IS 16205 (Part 24) : 2017 complete all as specif
ied and as directed.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 90 mm, minimum inside dia 76 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 120 mm, minimum inside dia 103 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 complete all as specified and directed and testing on completion.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I) including taking out old existing earthing complete all as directed.
Supply and fixing of hot press moulded SMC (Sheet Moulding Compound) junction box of inside dimention 210 mm x 190mm x 95mm including 4 Nos aluminium stud terminal of suitable size and one no MCB SP 2.5 amps and fixed on pole with clamps, bolts and nuts with pole complete with two coat of synethictic enamel paint powder coated as provided by manufacturer all as specified and directed.
S&F PVC insulated multi stranded copper conductor cable 1.5 sqmm two core and making connections of street light complete all as specified and directed.
M&L for repositioning of street lights on pole by replacing necessary clamp with nuts and bolts complete all as specified and directed.
S&F in replacement LED street light 60 watt with aliminium housing toughned glass IP-66 weather protection complete all as specified and directed.
S&F GI Pipe 80mm bore light grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed .
Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed.
S&F GI Pipe 50mm bore light grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed .
Material and labour for cable route path indicators made out of precast PCC mark LT cable 1100 V having PCC pillar of size 700mmx220mmx80mm, embedded 300 mm below ground level with PCC 1:3:6 (Type C1 using 20mm above ground level incl colour paint above ground level complete excavation and earth work complete all as specified& directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_819730.xls
BOQ • 0.32 MB
Tender_69.pdf
Tender Documents • 0.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .