| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.4 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹49.7 L+₹7.6 L (17.9%)Rejected-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹51.3 L+₹9.2 L (21.9%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹51.3 L+₹9.2 L (21.9%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | 4 | Rejected-Finance Not being the lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹47.4 L
EMD Value
₹94,160
Closing Date
7 Nov 2023, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
COMPREHENSIVE MAINTENANCE OF FIRE FIGHTING SYSTEM WATER DISTRIBUTION PIPELINES PUMPS VALVES, PANELS WITH CONNECTED ACCESSORIES AT RCI TECHNICAL AREA ZONE-I UNDER GE I RND RCI HYDERABAD
2023_MES_623585_1
8892
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE I R AND D RCI
MES enlisted Class D category a ii and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹94,160
Yes
25 Jan 2024
17 Oct 2023
9 Nov 2023
17 Oct 2023
7 Nov 2023
31 Oct 2023
Amount
S&F in repairs, gun metal Hydrant landing valve of size 63mm, single head outlet with hose coupling adaptor of size 63mm size instantaneous spring locks arrangements and blank cap complete as per IS-5290 type 'A' all as specified and directed.
All as per item No 1 but for type 'B', double head outlet. Make for item No 1 & 2 : ALLIED/ NEW AGE INDUSTRIES / SAFEX / NITIN /KARTAR/WINCO
S&F in repairs, stand post made out of mild steel pipe of size 80mm dia heavy grade of 1.2m height and providing necessary flanges at both ends suitable for fire hydrant single out let including flanged reducer and other fittings suitable for stand post with necessary welding to existing pipe including earthwork in any type of soil complete all as specified and directed.
S&F in repairs, cotton synthetic fibre reinforced rubber line of size 63mm dia 15m length conforming to IS 636 with male and female couplings conforming to IS 903 duly housed in fire hose box complete all as specified and directed.
S&F in repairs, hose box of size 750 x 600 x 250mm outdoor type made out of 1.2mm thick mild steel sheet with frosted glass doors, lock and key arrangement including stand for the hose box made out of 80mm dia medium grade mild steel pipe, 1.50m height, welded at top and bottom with 6mm mild steel plate, duly embedded in PCC 1:2:4 type B1 using 20mm graded stone aggregate and painted as per fire code, the hose box shall be installed near the hydrant by providing 2 Nos of cotton synthetic fibre reinforced rubber line of size 63mm dia 15m length with male and female couplings duly housed in fire hose box complete all as specified and directed.
S&F in repairs, 63mm dia water monitor with gun metal nozzle conforming to IS 8442 complete all as specified and directed.
Complete removal of existing paint from existing fire hydrant stand post of any size and type at vaious location of RCI and applying two coats of synthetic enamel paint over a coat of primer as per colour code including writing 8cm size letters in white colour (FIRE) complete all as specified and directed.
All as per item No 7 above but for Hose boxes
Supply, laying welding, fixing, leak proof testing and commissioning of 200mm bore, medium grade mild steel ERW pipes conforming to IS 3589 with bitumen wrap coating over the external surface of the pipe including necessary specials/fittings and taking down old unserviceable pipe complete all as specified and directed. Note: Excavation and earthwork will be measured and paid seperately.
All as per item No 9 above but for 150mm bore of pipe
All as per item No 9 above but for 100mm bore of pipe but conforming to IS 1239
All as per item No 9 above but for 80mm bore of pipe but conforming to IS 1239 Make for item No 09 to 12: TATA, JINDAL, PRAKASH
Supply, install, test and commissioning of 200mm bore CI Sluice Valve in repairs, Class PN-1.6, both ends flanged and drilled type with stainless steel spindle including wheel, suitable rubber gasket for flanged joints, ISI marked, including provision of necessary jointing materials nuts and bolts, washers etc., complete all as specified and directed.
All as per item No 13 above but 150mm bore Sluice Valve.
All as per item No 13 above but 100mm bore Sluice Valve.
All as per item No 13 above but 80mm bore Sluice Valve. Make for item No 13 to 16: KIRLOSKAR, LEADER, L&T, ZOLOTO, KARTAR
Supply and fixing Danfoss Pressure switch Model No KP36 regulation range 2 to 14 bar pe complete all as specified and directed
Supply and fixing 4 Sqmm 2 core FR PVC Copper Conductor including casing caping all as specified and directed
Supply and fixing PVC Fire Hydrant Coupling Ring washers of size 63mm
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., forming bottom surfaces to required slope/gradient where pipe are laid and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for Bailing out the water from the semi underground static water tank of 1,35,000 litres capacity without causing any interruption to regular water supply system and cleaning the walls, roof and floor thoroughly by using scrapper and removing the deposited scales/ fungus/ sludge/dirt etc and removing the same out of site, cleaning thoroughly with water and bleaching powder and finally with chlorine solution for complete anti bacterial disinfections including writing date of cleaning on the black back ground with white synthetic enamel paint complete all as directed.
M&L, Construction of brick masonry valve chamber, 1000 x 1000 x 1000mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40mm graded stone aggregate 150mm thick, 100mm wide offsets alround over 100mm thick hard core, brick masonry walls built in CM 1:6, 50mm thick coping and floor in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, finished even and smooth, rendering 15mm thick in cement mortar 1:4, finished even and smooth without using extra cement internally and externally upto 150mm below GL including top of floor including excavation earthwork in any type of soil, 3mm thick mild steel sheet cover fixed on 40mmx40mmx6mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handles and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50m etc., complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I and as directed.
Disconnecting electrical connection from the centrifugal pump motor main housing of 40 HP capacity and taking out from the installed position, transporting for repairs/ servicing to an approved workshop and transporting back after carrying out repairs, servicing/overhauling, assembling, installing in its original position and connecting up all electrical connections, testing and commissioning complete all as specified and directed. Note: 1) Unit rate quoted shall be deemed to be include the cost of packing materials. 2) Spares replaced will be measured and paid for separately as Supply only.
All as per item No 26 above but 25HP Pumpset.
All as per item No 26 above but 15HP Pumpset.
Disconnecting water and mechanical connection from the impeller and casing of centrifugal pumpset of 40 HP capacity and taking out from the installed position, transporting for repairs/servicing to an approved workshop and transporting back after carrying out repairs, servicing/ overhauling, assembling, installing in its original position and connecting up all mechanical and water connections, testing and commissioning complete all as specified and directed. Note: 1) Unit rate quoted shall be deemed to be include the cost of packing materials. 2) Spares replaced will be measured and paid for separately as Supply only.
All as per item No 29 above but 25HP Pumpset.
All as per item No 29 above but 15HP Pumpset.
Cutting and taking out the burnt out winding from the stator carefully, cleaning the stator from the deposits of burnt copper and carbon using necessary cleaning agent and applying slot insulation with Melinex paper and rewinding the stator with super enamelled copper wire of same guage and same number of turns as that of existing carefully and tying the winding free from induction vibrations and bring the winding to operate on 415 volts three phase AC supply of 50 Hz, preheating in oven and applying the insulating varnish and post heating for attaining proper insulating strength for Pump motor of capacity 40HP complete all as specified and directed.
All as per item No 32 above but 25HP Pumpset.
All as per item No 32 above but 15HP Pump motor.
Supply only DE bearing of 40HP pump motor as that of existing make and model including applying bearing grease complete all as specified.
All as per item No 35 above but 25HP Pump.
All as per item No 35 above but 15 HP Pump.
Supply only impellor of 40HP pump motor as that of existing make and model including applying grease complete all as specified.
All as per item No 38 above but 25HP Pump.
All as per item No 38 above but 15HP Pump.
Supply only pump shaft for 40HP pumpset as that of existing make and model including applying grease complete all as specified.
All as per item No 41 above but 25HP Pump.
All as per item No 41 above but 15 HP Pump.
S&F in repairs, fully automatic Star Delta Starter in sheet steel enclosure with single phase protection feature, max motor output at 415voltst3 phase of 40HP, complete all as specified and directed.
S&F in repairs, fully automatic Star Delta Starter in sheet steel enclosure with single phase protection feature, max motor output at 415volts 3 phase of 25HP, complete all as specified and directed. Make for item No 44 to 45: L&T , Seimens , CG
omsai thermax engineers
S.S.ENGINEERING CORPORATION
Universal refrigeration and Engineering Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .