Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance | L1 | Accepted-Finance Documents verified in order | |
| 2 | L2₹2.5 L+₹2,950 (1.20%)Accepted-Finance G 1 186 CHIRAG AHUJA G 1 186 UTTAM NAGAR UTTAM NAGAR DELHI 110059 UDYAM DL 11 0014734 | WEST DELHI | DELHI | 110059 | L2 | Accepted-Finance Documents verified in order | |
| 3 | L3₹2.5 L+₹3,068 (1.25%)Accepted-Finance | L3 | Accepted-Finance Documents verified in order |
Tender Value
₹2.4 L
Closing Date
19 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh C S Rao, IDSE,EE,Garrison Engineer
Military Engineer Services GE AF Adampur
Misc Work
2020_MES_367030_1
3073/012/E3
Limited
Miscellaneous Works
Works
30 days
GE AF Adampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
26 Aug 2020
6 Aug 2020
21 Aug 2020
6 Aug 2020
19 Aug 2020
6 Aug 2020
30 days
1. Maint,servicing , cleaning of window type room AC 1.5 Ton capcity at site cleaning of equipment and blower for removing dust checking the wiring, running capcitor, starting relay, overlaod relay, thermostat switches, condenser motor, blower/condenser fan rectification of fault, connecting and testing on oad all as directed by Engineer-in-Charge Job -10 2. Maint, serviing, cleaning fo split type AC 1.5/2 Ton capcity at site clearning of equipment with blower for removing dust checking the wiring, running capcitor, starting relay, overlaod relay, thermostat switches, condenser motor, blower/condenser fan rectification of fault, connecting and testing on oad all as directed by Engineer-in-Charge Job -10 3. Disconnecting, cutting and taking out unsericeable sealed unit compressor of Window/Split type AC any capcity, any make & model and fitting/fixing of serviceable sealed unit compressor brought against item Ser No 01 & 02 here in after soldering, welding, brazing as reqired and inclding charging of refrigeration gas and oil in the exchanged compressor, making electric and mechanical connections installlations of air conditioner at site and testing on oad complete all as specified and directed Job -07 4. Provn of clean exchange of unserviceable compressor removed against serial item No 5 here-in-before with serviceable compressor for window/split type AC 1.5 Ton capcity complete all as specifed Job - 07 5. Rewinding of blower motor of window/split air conditioner, water coller and refrigerattor of anyh capcity, make and model with lsuppper enamelled copper winding wire of adequate size and guage, varnishing, drying, packing with insulation paper including repalcement of GM bushses/bearing, fixing and testing on load complete all as specified and directed Job - 07 6. Starting relay suitlable for 1.5 Ton capcity split/window type air conditioner having contact rleay lper pole 22V - 163V, torque 75, including taking out the old unserviceable rleay complete all as specified and directed. Nos - 10 7. Thermostatt siwtch for 1.5 Ton Capacity window type room AC including taking out the old unserviceable switch complete all as specified and directed Job - 10 8. Blower motor suitable for split type AC 1.5 Ton includin dismantling the old unserviceable blower motor complete all as specified and directed No -2 9. Replacement of Air filter suitable for window type AC 1.5 Ton capcity all as per samle and directed by Engr-in-charge, Nos - 10. 10 Running capacitor 32 to 45 MFD including taking out the old unserviceable capacitor complete all as specified and as directed Nos - 07 11. Dismantling of indoor unit of split type AC 1.5 Ton from existing position of relocating at other location making good disturbed surface of wallby providing brick works, plactering colour washing so as to match with the colour of the existing wall and all necessary arrangement all as specified and directed Nos - 06 12. Dismantling of outdoor lunit of split tyhpe AC 1.5 Ton cap from existing position, for relocating at other location making good disturbed surface of wall by providing brick works, plastering colour , washing so as to match with the coloour of the existing wall and all necessary arrangement all as specified and directed Nos - 06 13. Copper pipe 5/8" with sleeves (6RM for each AC) RM - 36 14. Copper pipe 1/4" with sleeves (6 RM for each AC), RM - 36 15. Cost of FR,PVC cable insulated sheathed flexible 3 core coppper conductor size 2.5 Sqmm Make - Plaza (5 RM for each AC , RM - 30 16. Cost PVC Pipe 15mm dia (5 RM for each AC) RM - 30 17. Cost of Gas R-22 (2 Kgs for each AC) Kgs 12 18. Labour charges for laying of PVC cable, wrapping of PVC pipe welding/brazing of copper pipe/filling of gas fixing of drain/taesting of split type AC Job - 06 Note:- Less credit of material Rs 3500/- Job is Guarranted for 01 year (Complete Job -01Only)
Ahuja International
Rajan Refrigerations & Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .