Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.3 L+₹4.3 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
8 Oct 2020, 6:00 pmClosed
GE E/M Lucknow.
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR / MAINT OF E/M WORKS AND B/R WORKS IN SUB STATION BUILDING INCLUDING DG SET INSTALLATION BUILDING AT VARIOUS LOCATIONS IN THE AREA OF AGE EM EXT(ELECT) UNDER GE E/M LUCKNOW.
2020_MES_375175_1
GE/EM/LKO/EXT(ELECT)/T-47 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Lucknow Cantt.
Class D and above and category a(i) and b(i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow.
₹98,000
Yes
5 Jan 2021
5 Sept 2020
10 Oct 2020
5 Sept 2020
8 Oct 2020
19 Sept 2020
Amount
M&L taking down old interlocking tiles from existing position and staging on site after segragating the serviceable tiles for reuse at site etc complete all as specified and directed by Engineer-in-Charge.
Refixing the serviceble interlocking tiles complete all as specified and directed by Engineer-in-Charge.
M&L for cutting the tree branches any type / shape / thick, over the building/near the building /sorrounding the installation etc complete all as specified and directed by Engineer-in-Charge.
M&L for moorum filling in floors or paving, laid in layers n.exc 15 cm thick levelled and rammed incuding watering etc complete all as specified and directed by Engineer-in-Charge.
M&L for surface dressing n exc 15mm deep etc complete all as specified and directed by Engineer-in-Charge.
M&L for hard core of broken stone aggregate n exc 20mm deposited spread and levelled in layers n exc 10cm thick electric sub station complete all as specified and directed by Engineer-in-Charge.
M&L for hard core of broken stone or boulders gauge n exc 63mm deposited spread and levelled in layers n exc 10cm thick watered and rammed to a true surface in electric sub station etc complete all as specified and directed by Engineer-in-Charge.
Taking out the existing RCC duct cover from yard duct and cleaning the duct manualy such mud earth, vegetable roots and other materials obatain from ducts and deposited the material as directed place and refixing the duct cover complete all as specified and directed by Engineer-in-Charge.
M&L for type D2 1:4:8 (40 mm graded aggregate) cement concrete in foundation and mass concrete for bricks foundation etc complete all as specified and directed by Engineer-in-Charge.
M&L for bricks work with sub class B bricks straight or curved on plan exc 6m means radius built in cement mortar 1: 6 etc complete all as specified and directed by Engineer-in-Charge.
M&L for type B1 1:2:4 (20 mm graded aggregate) for providing cement concrete in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courese strin course, lacing course string courses lacing courses, parapets, and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement plaster 1:6 on fair faces of bricks work or concrete surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for 1 cm thick lime spreading the surface of earth before laying of moorang at electric sub station etc complete all as specified and directed by Engineer-in-Charge.
M&L for surface excavation n.exc 30 cm deep and averaging 15 cm deep getting out soft/loose soil etc complete all as specified and directed by Engineer-in-Charge.
M&L for broken stone or boulders with hard core of gauge not exc 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick cement concerete type C2 1:3:6 (40mm graded aggregate) complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed or bedding layers of mortar 15 mm thick for laying floor finishes in 1:4 cement plaster etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete tiles 20cmx20cmx20mm thick machine pressed set jointed and pointed in neat cement slurry in floors and cut and polished with gray cement and pigments etc complete all as specified and directed by Engineer-in-Charge.
M&L for type B0 1:2:4 (12.5mm graded aggregate) for providing cement concerte in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth course string course, lacing course string courses lacing courses, parapets, and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
Dismantling post or struts (wood/steel or rcc) any section incl taking out embedded portion and making good distrubed on normal ground in concrete, brick works masonary complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling fencing wire mesh any type complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) each n exc 0.5 cum getting out returing filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm in soft soil etc complete all as specified and directed by Engineer-in-Charge.
M&L for type C2 1:3:6 (40 mm graded aggregate) cement concrete in foundation and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
S&F rolled mild steel such as MS angle 65x65x6mm and MS plate iron 40x6mm cut to required length fixed independently including all necessary drilling, bolts or riveting etc and similar works complete all as specified and directed by Engineer-in-Charge and conforming to grade Fe 410-S.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or squre nut exc 5 cm long but n.exc 10cm long dia of neck in 11 to 15mm etc complete all as specified and directed by Engineer-in-Charge.
M&L for preperation new steel surface any description over 10 cm in width or girth not other wise decribed and painting with two coat of synthetic enamelled paint over a one coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge.
Supply only chain link MS galvanised fencing 50x50mm mesh (10 guage) GI wire etc complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing incl line wire any mesh size and type to any type of standards rails straining bolts etc incl provision of binding wire etc complete all as specified and directed by Engineer-in-Charge.
S&F galvanised 2 stranded steel barbed wire with 2.24mm dia barbed with 2 mm dia barbs at 75 mm spacing and straiing and fixing to any type of standard rails strain-ing bolts, incl securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured etc complete all as specified and directed by Engineer-in-Charge.
Dismantling concrete of any description and any position not otherwise specifically provided for cement concrete and cement concrete is reinforced etc complete all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement concrete type B1 (1:2:4 ( 20 mm graded aggregate ) in landing, cover slabs ( for main hole) chullah,hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc complete all as specified and directed by Engineer-in-Charge.
M&L TMT bar 6mm to 8mm dia Gde I IS-432 (Part-I) and over cut to length, bends to shape required incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge.
S&F Fe 290 (Gde E-165) chequered plates 6mm thick, channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachement etc complete all as specified and directed by Engineer-in-Charge.
M&L for Fe 290 (Gde E-165) compound griders and stanchions, lattice dirders, aerial masts, staging for water tanks and the like incl caps, bases, splices etc built up from two or more beam or channels sections or angles with plates incl all lattice bars stiffeners gusset plate etc complete all as specified and directed by Engineer-in-Charge.
Cleaning the sub station / transformer / two / four pole structure around 5 m radious in every month duly taking down unwanted material/grass/vegetable roots/small tree etc complete all as specified and directed by Engineer-in-Charge.
Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
All as per Sl item no.36 above but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
All as per Sl item no.36 but for one socket outlet point on same the baord with other switches.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
S&F switch piano flush type single pole, one way 5 Amps 240 ISI marked etc complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 3 pin 5 A flush type ISI marked 240 volts ISI marked etc complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination 2 in 3 pin 5 and 15 Amps flush type ISI marked universal suitable for 240 volts etc complete all as specified and directed by Engineer-in-Charge.
M&L for ceiling rose with three terminal as per relevant IS complete all as specified and directed by Engineer-in-Charge.
Supply only decorative box type fitting with blue colour end cap for LED tube 20 watt luminaire for 230 volt AC incl LED tube 20 watt complete all as specified and directed by Engineer-in-Charge. Make:- C&S cat part No.LTDC01220WLED/WD/CG cat part No.DMLN1LT8-16 equivalent in Havells / PHILLIPS
Supply only decorative box type fitting with blue colour end cap for LED tube 10 watt luminaire for 230 volt AC incl LED tube 10 watt complete all as specified and directed by Engineer-in-Charge. Make:- C&S cat part No.LTDC01210WLED/WD/Crompton Cat part No LCL-10-CDL or equivalent in Havells / PHILLIPS
S&F stepped type fan electronic fan regulator flush type ISI marked on the existing fenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed by Engineer-in-Charge. Make Legrand cat part No 507641 or equivalent in L&T / Schnieder
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way TPN suitable for MCB DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incoming and out going controlling circuit of capacity 6-32 Amp breaking capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incoming and out going controlling cercuit of capacity 40-63 Amp breaking capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incoming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacity etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB triple pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacity etc complete all as specified and directed by Engineer-in-Charge.
M&Lfor sub main wiring with two single core, 6.0 sqmm + 1x6.0 sqmm earth wire, PVC insulated,ISI marked, unsheathed, 1100 volts grade multistranded copper conductor FRLS cable drawn into and including suitable size non metalic rigid pvc conduit (ISI marked) concealed/surface with all accessories and including one single core pvc insulated multistranded unsheathed 1100 volts grade copper conductor FRLS cable as earth wire of the following size complete all as specified and directed by Engineer-in-Charge.
S&F LED flood light 150 watt IP66 high power flood light with pressure die cast aluminium housing complete all as specified and directed by Engineer-in-Charge. (Ballast Pen) Make C&S Model No LTEFI150WHPLED or equivalent approved by GE
S&F decorative post top lantern for 360 C indirect light resistant to impact and corrosion, Glare free and better uniformity IP-65 protection miliky version with all accessoreis complete all as specified and directed by Engineer-in-Charge. Make C&S model No LTGL30-24X1HPLED or equivalent PHILLIPS/HAVELLS
Supply only digital earth resistance tester with measuring range 0-20 Ω and higher resolution range 0-200Ω and 0.1 at 0-2000Ω accuracy ± 1% supplied complete with test leads, spikes and simplified measurement probe, instruction manual, shoulder belt and batteries provided as standard and also measures earth voltage upto 200V with accuracy ±2% complies with EN/IEC 61010-1 CATEII 300V etc complete all as specified and directed by Engineer-in-Charge. Make- Creative tools/stanlay .
Supply only clamp on earth resistance tester based on loop resistance principle that provides earth resistance measurements without any auxililary spike electrodes or unhooking ground earth wire the equipment simply has to be obtain earth resistance value with high accuracy the unit also measures leakage clamp on earth/ground resistance meaurement upto 0.010-1000 Ω, acuracy 0.1 to 0.99 ohm : 1% 1-49.9 ohm 1.5% also meausre current leakage upto 20 Amp with all accessories as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge. Make- crative tools/Stanlay or equivalent approved by GE
Supply only Manualy operated insulation tester with test voltage 5 KV, measuring range 0-250GΩ accuracy ±5% operating temp -15 t0 55 deg C with 80% relative humiditywith all accessories as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge.
Supply only digital insulation tester with test voltage 5 KV, measuring range 0-250GΩ accuracy ±5% operating temp -15 t0 55 deg C with 80% relative humidity with all accessories as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge. Make-Creative tools/Stalay.
Supply only digital multimeter with true RMS measurement complying to IEC 61010 and over load categories CAT-III 1000 V and CAT IV rate 600 V, provides measurement of eletrical parameters incl DCV up to 1000 V, ACV upto 750 V, AD/DC current upto 10 A, resistance upto 60 ohms , Capacitance upto 4000Uf, frequancy upto 10MHz, RS232 cable for computer connectivity etc all accessories as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge.
Supply only rubber mat 12 mm thick suitable for 33 KV and out door type in Old and New MRS with all accessories as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge. Make : JYOTI
Supply only engineering helmet with all accessories (Blue colour) as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge.
Supply only hand gloves suitable for 33 KV line(Red colour) with all accessories as per manufacturer norms etc complete all as specified and directed by Engineer-in-Charge.
Supply only rubber boot 9 Nos suitable for 33 KV line with all accessories (full pvc dual density high ankle gum boots (12 " height ) complete all as specified and directed by Engineer-in-Charge.
Renewal of existing earthing (GI plate earthig) with provision of new layers of charcoal and salt all as specified in electrical plate No 3 of SSR Part-I, including cleaning of existing GI earth plate, strip/wire etc and connecting with new bolts, nuts and washers complete and testing on completion in all respect complete all as specified and directed by Engineer-in-Charge. Note: - Excavation, PCC for earth pit and cover, watering pipe, funnel with wire mesh, earth lead and protection pipe shall be measured and paid separately.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/ loose soil for foundation, trench of cables, pipes etc or for shaft, wells, manholes n exc 10 Square Metre on plan and getting out including trimming the sides and forming bottom surfaces to required levels, complete all as specified and directed by Engineer-in-Charge.
All as per item No 66 above but depth exceeding 1.5 and not exceeding 3 metres
Returning, filling in and including spreading, levelling, watering and well ramming in layers n. exe 25 cm each in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing in excavated material to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
S&F in repair CI funnel made as specified in SSR Part -I electrical plate No 3 fixed with fixed with GI pipe of watering by welding or threading etc complete all as specified and directed by Engineer-in-Charge.
S&F galvanised steel tubing 15 mm bore light grade with all fittings in earthing for watering the earth including taking down of old steel tubing complete all as specified and directed by Engineer-in-Charge.
S&F galvanised iron strip as earth continuity conductor or main earthing lead fixed to walls or burried in ground of size 32x6 mm complete all as specified and directed by Engineer-in-Charge.
M&L for pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, earth pit cover as per existing size including necessary formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Earth pit chamber PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle as specified in SSR 2009 Part I Electrical Plate No 3 incl taking out brocken pits and deposited as directed place and marker made out of 1.6 mm thick ms plate (30x30 cm size,welded with 12 mm dia round ms bar incl painting with one coat of red oxide primer and two coat of synthetic enameld paint and writing the earth pit no and result as directed hight letter etc complete all as specified and directed by Engineer-in-Charge.
M&L for earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI Strip 32x6mm by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 5 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment / substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap / granite/ Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Note : (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperatly . (iii) Test result should be less than 1 ohms or satisfaction of user.
Supply and fixing fire retardant electric insulation synthetic mat INSULATICA 2000" for 33 KV 3.0 mm thick +10% conforming to BIS DOC No ETD -02 (5231) P dt 2003. meeting requirement of IS 3043, IS: 5216 (Part 1,2,3) IS : 8437 and IEC 479 pub-1 IEC 61111 & 61112 tested for brake down strength tensile /elongation ageing properties. Insulation resistance, affects of acid , alkaline, Diesel & transformer oil, leakage current test fire test etc. having min width of 1000m + 20 mm complete as required suitable and using adhesive and allied chemical and scaling of all joints and border ends and fixing decorative taps the installed sheet complete all as specified and directed by Engineer-in-Charge.
Supply and fixing fire retardant electric insulation synthetic mat INSULATICA 2000" for 11 KV 3.0 mm thick +10% conforming to BIS DOC No ETD -02 (5231) P dt 2003. meeting requirement of IS 3043, IS: 5216 (Part 1,2,3) IS : 8437 and IEC 479 pub-1 IEC 61111 & 61112 tested for brake down strength tensile /elongation ageing properties. Insulation resistance, affects of acid , alkaline, Diesel & transformer oil, leakage current test fire test etc. having min width of 1000m + 20 mm complete as required suitable and using adhesive and allied chemical and scaling of all joints and border ends and fixing decorative taps the installed sheet complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium self supporting stool type folding ladder 12' made out of AL C section and steps of AL corrugated tubing provided with AL plate form fitted with hing and rubber pads at lower bottom complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair heavy duty exhuast fan 600 mm, 900 rpm turbo force model single phase incl all accessories as per manufacturer norms and unserviceable fan deposited in MES store yard etc complete all as specified and directed by Engineer-in-Charge. Make -HAVELLS/USHA/ORIENT/BAJAJ
Supply and fix in repair heavy duty exhuast fan 450mm, 900 rpm turbo force model single phase incl all accessories as per manufacturer norms and unserviceable fan deposited in MES store yard etc complete all as specified and directed by Engineer-in-Charge. Make -HAVELLS/USHA/ORIENT/BAJAJ
M&L rewinding of exhaust Fan of 600/450mm sweep/1200/1400 mm sweep ceiling fan of any make with super enameled copper wire (gauge/weight of copper coils shall be same as per existing dismantled fans), including varnishing incl replacement of capcitor and 3 core cable from ceiling rose to connector of equipment complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair ceiling fan 1200mm sweep with all accessories as per manufacturer norms and unserviceable fan deposited in MES store yard etc complete all as specified and directed by Engineer-in-Charge. Make- HAVELLS/USHA/ORIENT/BAJAJ
Supply flood light 30 watt LED flood light energy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power LED as light source suitable for highlighting architectural feature or area lighting also lighting also suitable to rough services/ installation incl taking down old one etc complete all as specified and directed by Engineer-in-Charge. Make-Havells cat part No. JETAQUANTOPLUSEFLP30WLED757SYMLENS or equivalent approved by GE.
S&F LED Driver suitable for LED Light fittings 36 to 45 watt any height etc complete all as specified and directed by Engineer-in-Charge. MAKE-as per sample make-C&S/Crompton/Havells/PHILLIPS.
Supply only LED Driver suitable for LED Light fittings 100 watt any height etc complete all as specified and directed by Engineer-in-Charge. MAKE-as per sample make-C&S/Crompton/Havells/PHILLIPS
Supply only LED Driver suitable for LED Light fittings 120/150 watt any height etc complete all as specified and directed by Engineer-in-Charge. MAKE-as per sample make-C&S/Crompton/Havells/PHILLIPS
S&F lead acid battery suitable for solar light 12 volts,110 AH with lead acid suitable for solar light include initial charging (MAKE-EXIDE/AMRON) including connection and testing incl taking down old one complete all as specified and directed by Engineer-in-Charge & approved by GE.
M&L for taking down solar light from pole and refixing the same after repair and also incl minor repair complete all as specified and directed by Engineer-in-Charge Note. Driver and cable will be measured and paid respectively.
Ajanta Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .