| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹31.9 L+₹2.6 L (9.05%)Rejected-AOC OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹33.2 L+₹4.0 L (13.7%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹38.1 L+₹8.9 L (30.3%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
19 Jun 2021, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
RENOVATION /ALTERATION OF SECOND FLOOR OF OLD P-8 BUILDING AT CFEES UNDER GE I RND DELHI
2021_MES_442111_1
GE/RND-26/DLI/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class- D, Cat a(i), c(i)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
₹73,000
Yes
8 Jul 2021
11 May 2021
21 Jun 2021
11 May 2021
19 Jun 2021
7 Jun 2021
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing the rubbish out side MoD land complete all as specified & directed.
Demolition in reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (Below or above ground floors) in any position complete all as specified & directed.
M&L for PCC 1:2:4 Type B1 (using 20mm graded stone aggregate) in Coving, weathering, slightly rounded or chamfered angles and throating and similar works complete all as Specified & directed
M&L for Vitrified tiles 9 to 10mm thick (square/rectangular) light shade area of each tile exc. 0.16 Sqm but n.exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over & including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified & directed.
All as per item No 4.00 above but in skirting/dados, in vertical surfaces over and including 9-10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over & including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified & directed.
M&L for glazed ceramic coloured tiles (square/rectangular) 7 mm thick not exceeding 0.16 sqm as in dado/skirting etc over and including 10 mm thick rendering in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M&L Granite (of any type) stone slabs or tiles 18 to 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 20 mm thick cement screed bedding in CM 1:6 including cutting and polishing complete all as specified & directed.
M&L for moulding or rounding, cutting and smooth finishing on edges of Granite tiles etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed
M&L Rendering 15 mm thick in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified & directed.
M&L for preparation of newly plastered surface and applying two coats of oil bound distemper over a coat of chalk whiting on walls complete all as specified and directed.
Complete removal of existing treatment from ceiling (internal/external), walls, fins, chajja etc including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots complete all as specified & directed.
M&L for applying two coats of distemper oil emulsion over a coat of chalk whiting on ceiling complete all as specified & directed.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified & directed.
S&F Anodised aluminium snap grid frame work for false ceiling and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed
S&F 8 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified & directed. Note: Frame work for ceiling shall be measured and paid separately.
Taking down chowkats or frames with shutters ( without taking off shutters from the frame ) area exc 1.50 sqm but not exc 4.00 sqm each complete all as specified & directed.
Taking down steel window or of any descriptions with shutter area n.exc 1.50 sqm each complete all as specified & directed.
S&F Aluminium powder coated anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing powder coating shall be minimum thickness 50 micron complete all as specified and as directed.
S&F Aluminium powder coated anodised door and shutters single or double leaf glazed/pre laminated board exterior quality partly glazed panels fabricated including aluminium anodised beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following :- (a) Aluminium anodised vertical section in shutter 85.00x 44.45 x2.00mm and all as specified. (b) Aluminium anodised top rail & styles shutter section 95.25 x 44.45 x 2.00 mm and all as specified. (c) Aluminium anodised tower bolt 02 Nos in each shutter 200mm long and all as specified. (d) Aluminium anodised handle 02 Nos in each shutter 150mm long and all as specified. (e) Aluminium anodised middle lock rail / bottom rail section 150.00 x 44.45 x 2.65mm and all as specified.
S&F Aluminium powder coated anodised window/ventilator frame section 100x44x2mm fixed with thrust bolt in walls by drilling (any number of leaf) complete comprising the following :- (a) Aluminium anodised shutter 44x44x2mm top rail/bottom rail/sides style and all as specified. (b) Aluminium anodised butt hinges 04 Nos in each window 100mm size and all as specified. (c) Aluminium anodised tower bolt 02 Nos in each shutter 150mm long and all as specified. (d) Aluminium anodised hande 04 Nos in each shutter 150mm long and all as specified. Note: Particle board & glass etc shall be measurred & paid separately.
S&F 50 micron thick podwer coated aluminium grill 6x 45mm thick section 10cm center to center spacing complete with U-channel alround fixed in windows with screws complete all as per specified and as directed.
S&F in repair venetian blind 1st quality with 100mm wide flaps of fibre cloth of approved shade vertical type having tiling and sliding arrangement by means of nylon threads made out of six fixed with aluminium channel powder coated and MS clamps or as per manufactures design / instructions complete all as specified & directed.
Taking down aluminium sliding type door/ swing type door /aluminium partition of any description in any position complete all as specified and as directed.
S&F aluminium powder coated fully glazed /partly glazed and panelled fixed partition and fixed glazing and made out of aluminium section 63.50X38.10X1.60mm including necessary jointing cleats glazing clips rubber packing anodised aluminium beading fixed to walls, floor with PVC rawl plug etc complete all as specified and as directed. Note : Panel board & glass etc shall be measured and paid seperately
S&F 12 mm thick particle board exterior grade with decorative prelaminated both sides of approved shades fixed to aluminium shutters/partitions etc complete all as specified & directed.
S&F 4.8 mm thick Plain sheet glass ordinary quality and fixing by means of glazing pins and rubber beading etc in aluminium partitions etc complete all as specified & directed.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 as in half brick wall complete all as specified & directed.
M & L TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending, spirally for columns hooking ends binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed.
M&L RCC nomial mix type B-2, 1:2:4 (using 20mm graded stone aggregate) as in slabs supported on walls complete all as specified & directed. Note : Reinforcment shall be measured and paid seperately
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces concrete complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube & fixing in opening as per specification & drawing.
S&F factory made solid panel PVC door shutter 30mm thick (style) consulting of frame MS tubes for top or bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20mm with stick in side with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on other side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded sealed to be sides and rails with suitable PVC sheet beading and joined together with solvent cement as per specification and drawing in SSR complete all as specified and as directed.
S&F flush shutters solid core construction 30 mm, with block board core and both sides covered with decorative face veneer with lipping/frame to match complete all as specified & directed.
Taking up or down steel tubing of 15mm internal bore and connections incl cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing of 20mm internal bore and connections complete all as specified and directed.
Taking up or down steel tubing of 25mm internal bore and connections complete all as specified and directed.
M&L for making connection of PP-R distribution branch with PP-R main of 16 to 40mm outer dia of pipe by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
Cutting existing steel tubing of 25mm bore for alterations or additions (Each cut measured ) screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) all as specified and directed.
M&L 20mm outer of 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed.
All as per item ser No 41.00 above but 32 mm
All as per item ser No 41.00 above but 40 mm
Disconnecting existing PVC tank 1000 ltr capacity, setting aside complete all as specified and directed.
S&F rotational moulded polyethylene 3 layer water storage tank of 1000Ltrs capacity (cylindrical) vertical with (closed top) hoisted and fixed in position all as specified and directed.
S&F in repair Gun-metal gate valves, with iron wheel head, screwed both ends for GI pipe 20 mm bore and fixed complete all as specified & directed.
S&F in repairs vitreous China wash hand basin, white flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand complete all as specified & directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white or coloured (excluding fixing bolts flushing cistern and flush pipe) complete all as specified & directed. Note : Seat cover shall be measured & paid seperately
S&F Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
S&F in repairs PVC valveless syphonic action type 10 litre capacity flushing cistern low level white with inlet ball valve float and handle including brackets complete all as specified & directed.
S&F in repair chromium plated soap dish fixed to wall with CP brass screws etc complete all as specified and directed
S&F in repair Towel rail 600mm long, brass chromium plated fixed with chromium plated brass screws and wooden/ plastic cleats (minimum weight 190 gms) complete all as specified & directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm long etc. all as specified and directed.
S&F in repairs 15mm bore brass chromium plated bib taps fancy type with way flange screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified & directed.
S&F in repairs 15mm bore brass chromium plated pillars taps fancy type with way flange screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified & directed.
S&F brass chromium plated toilet paper with flap recessed type holder fixed to walls complete all as specified & directed.
S&F in repairs 15 mm bore Stop valves, brass, chromium plated, fancy type, with long shank and cup (concealed type), high pressure, screwed both ends for iron pipe or for unions complete all as specified & directed.
Dismantling of cast iron pipes, jointed in cement mortar upto 100mm dia of pipe complete all as specified and as directed.
S&F 100mm bore cast iron spun pipes, soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified & directed.
All as per item srl No 60.00 above but 75 mm.
S&F CI 75 mm bore bends (any radius), diminishing pieces or tapers (layers bore measured) complete all as specified & directed.
S&F CI 100mm bore bends (any radius), diminishing pieces or tapers (layers bore measured) complete all as specified & directed.
S&F CI 75 mm bore traps 'P' or 'S' complete all as specified & directed.
S&F CI 100 mm bore traps 'P' or 'S' complete all as specified & directed.
S&F in repairs 140mm floor door stoppers of aluminium alloy body and tounge, anodised with hard drawn steel springs, fixed in floors complete all as specified and directed.
Removing building materials etc outside MoD land, beyond the lead included in the rates, including loading, unloading and stacking at the distance 2 to 3 km complete all as specified and directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 3330mm x 160mm complete all as specified & directed.
M&L for at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 litres hole by drilling 6mm dia hole area downward angle of 45 degree at 150mm center to center and sealing the same complete all as specified & directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified & directed
M&L for Treatment of existing masonary using chemical emulsion @ one ltr per hole at 300mm interval including drilling holes 45 degree and plugging them with cement mortar 1:2 (1 cement :2 coarse sand) to the full depth of hole.complete all as specified & directed
M&L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubing down concrete surfaces with wire brushes cleaning with water allow to dry and appling a layers of Zinc rich epoxy primer as an antirust on all exposed reinforcement followed by a layer of bounding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specefied and applying two layers of guniting over and including steel welded mesh 2 mm dia of wire and appruture 75 mm, total thickness of guniting not exc 40 mm (Avg thickness) in Cement mortar 1:2 using OPC 53 grade cement mixed with polycreate mixture @2% by weight of cement or as per menufacturer instructions and finally applying cement plaster over guniting surface of required thickness to give even uniform and smooth finishes confirming to proper geometrics in cement mortar 1:3 to match and finish the surface as per the existing surfaces as in sides ,soffits of the slabs,chajja,fins,facia, parapets, lintels, columns and beams etc complete including necessary scaffolding ,shuttering,chasing to brick work or RCC members at any hieght up to 06 storied buildings including removal of all small trees/shurbs etc.
Taking down carefully point wiring copper/aluminium (light, fan, socket, and power) complete (including fittings such as switches ceiling roses, pendent regulators sockets except light fitting) and making good the disturbed surfaces complete all as specified and as directed.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm nominal area PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including suitable new GI sunken boxes 2 mm thick, modular frame and cover plate for fixing of modular switches as per required point in that board including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth duly complete including cutting, chasing the surface and then making good the same in CM 1:6 complete all as specified and directed.
All as per item No 74.00 above but for one socket point 3 pin 5 Amp 230 volt flush type on same board.
All as per item No 74.00 above but for one socket point out let 3 pin 5 Amp on independent board.
All as per item No 74.00 above but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor and 2.5 sqmm PVC insulated copper conductor as earth continuity conductor.
S&F modular switch flush type 5/6 Amps 230V AC complete one way.
S&F one switch and socket combination modular type 5 PIN 5 Amp 230 Volts AC Complete all as specified & directed.
S&F one switch and socket combination modular type 5 PIN 15 Amp 230 Volts AC Complete all as specified & directed.
S&F regulator for ceiling fan modular electronic step up/down type 2 module type 120watt- 2module suitable for 1200/1400mm ceiling fan complete all as specified and as directed.
S&F ceiling rose surface type bakelite 65x50mm two to three terminal 230V PVC polycarbonate Complete all as specified & directed
S&F in repair telephone socket jack With shutter RJ-11 complete all as specified and as directed.
Taking down of existing Ceiling/ Exhaust fan of any size & deposited to MES yard and refixing the same after painting with applying one coat of syntehtic enemel paint by spray machine and writting Ser No and MES No with Black colour and testing the serviceability of the fan complete all as specified and directed
S&F in repair of sheet metal enclosure, single pole and neutral with two pin and earth plug and socket complete with one single pole MCB SP,C Curve type of capacity 32 Amp, 10 kA complete all as specified and directed.
S&F in repair wiring for circuit/submain wiring along with earth wire with the 2x4 sqmm+ 1x4 sq mm earth wire of FR LSH PVC insulated copper conductor single core multistranded copper cable in and including concealed conduit pipe 20 mm external dia medium grade including all accessories complete all as specified and as directed
S&F in repair wiring for circuit/submain wiring along with earth wire with the 2x6 qmm+1x6 sq mm earth wire of FRLSH PVC insulated copper conductor single core multistranded copper cable in and including concealed conduit pipe 25 mm external dia medium grade including all accessories complete all as specified and as directed
S&F in repair wiring for circuit/submain wiring along with earth wire with the 4x25 qmm+2x25 sq mm earth wire of FRLSH PVC insulated copper conductor single core multistranded copper cable in and including concealed conduit pipe 40 mm external dia medium grade including all accessories complete all as specified and as directed
S&F in repair LED tube light with fittings & fixture 4 feet, 20 Watt and making all electric connections with three core PVC insulated, PVC sheathed copper conductor flexible cable 1.5 sqmm complete all as specified and directed.
S&F in repair LED luminaire, 2x2,36 W recess mounted pressure die cast aluminium luminaire in powder coated white finish with optimized heat sink for efficient heat dissipation and making all electric connections with 3 crore PVC isulated PVC sheathed copper conductor flexible cable 1.5 sqmm and separate replaceable electronic driver complete all as specified and as directed.
S&F in repair MCB 415 Volts 100 Amps, 10KA 04 pole 'C' series complete all as specified & directed.
S&F in repair MCB 415 volts 63 Amps, 10KA 04 pole 'C' series compete all as specified & directed.
S&F in repair MCB 240 volts 63 Amps, 10KA SPN 'C' series complete all as specified & directed.
S&F in repair MCB 6 Amp to 32 Amp SP 10 KA C' series complete all as specified & directed
S&F in repair MCB distribution board double door horizontal type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating. TPN 8 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 42 - IK 09 protection suitable for incorporation of MCB, including grouting in the wall, cutting & chasing etc complete all as specified & directed.
S&F in repair MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 4 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 42 - IK 09 protection suitable for incorporation of MCB, including grouting in the wall, cutting & chasing etc complete all as specified & directed.
S&F in repair sheet metal enclosure double door SPN 8 way with 240 V rated bus bar Complete all as specified & directed
S&F Exhaust fan 380mm sweep metalic type including louver shutter, AC single phase complete with all accessories making hole on wall to fix the fan & making good the demolished portion in CM 1:6 all as specified and as directed.
S&F rigid non- metallic concealed PVC conduit of size 40mm dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hook necessary T&P etc over the surface/concealed/ wall panel complete all as directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with GI wire 4.00mm by means of nuts, bolts and washers. GI Wire laid in 15mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:- (a) GI wire 4.00mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earting lead fixed to wall or buried in ground or drawn in conduit/pipe fixed on DB or any other indicated situation for loop earthing etc. as required 4mm dia galvanized iron wire complete all as specified and directed.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10%, 50 Hz, AC supply complete with cordless remote control unit ,5 star rating complete comprising of following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stabilizer inclusive in above rate.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , 5 star rating complete comprising of following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising. Compressor with motor,. air cooled copper condenser with fan and motor. unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.2 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stabilizer inclusive in above rate.
S&F in repair single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 32 Amps complete all as specified & directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified & directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed.
Taking down the existing split AC from its position and refixing the same at new or existing position in serviceable condition including gas charging as required and servicing the same all as specified and directed.
M/s Himgiri construction
m/s Kailash Chander
LR Mendiratta and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .