Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-Finance Accepted being L1 | |
| 2 | L2₹47.7 L+₹7.8 L (19.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹49.0 L+₹9.0 L (22.6%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.5 L+₹9.6 L (23.9%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.9 L+₹9.9 L (24.7%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Jan 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
REPAIR MAINT OF SUB STATION POWER HOUSE AND EXTERNAL ELECTRIC SUPPLY AT CERTAIN LABS UNDER GE I RD EAST BANGALORE
2022_MES_568677_1
8321
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I RD East Bangalore
D b (ii)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹94,000
Yes
6 Jan 2023
12 Dec 2022
4 Jan 2023
13 Dec 2022
2 Jan 2023
26 Dec 2022
13 Dec 2022 - 20 Dec 2022
Amount
Supply and refilling of SF6 (Sulfur hexaflouride gas ) for 66 KV SF6 outdoor circuit breaker to cool and Quench the arc on opening of circuit transmission class discharge capacity of 69KV for normal operation to maintain the desired pressure in SF6 and RMU as per OEM design and testing the pressure of each SF6 breaker of 66 KV and 11 KV RMU all as specified and directed
Supply & Fix in replacement of 66 KV, 800 Amp copper GOS with insulator in existing structure with necessary aluminum busbar / conductor connection in both sides with suitable clamping arrangements for smooth operation including testing all as directed : Notes Rates quoted by the contractor shall deemed to include for complete testing of insulator and GOS for entire satisfaction of Engr-in- Charge.
Supply and fix in replacement of traffo difference and integrated protection relay including microprocessor relay and display complete for 66 KV SF6 traffo control and relay panel control panel including Trip/Alarm/Out of service/healthy/edit modefollowing display parameter all as specified and directed. Make : Schneider electric Model No- MiCOM P631 or equivallant in C&S/Siemens/ABB
Supply and fix in replacement of outdoor type heat-shrinkable termination joint suitable for all climates, areas, and environments, even severely polluted areas, as well as for all installation conditions, including top feed installation and heat-shrinkable stress control sleeves non-tracking, heat-shrinkable outer insulation water- and corrosion-resistant, of conductor cross section 95-2500 sqmm, diameter over cable insulation 30-86mm, max diameter over outer cable sheath 110 mm creepage distance appx 2300 mm all as per Raychem product description OHVT-72H or equivalent make
Material and labour for maintenance, servicing & Oil Leakage arresting UPTO 250 KVA, 11KV rating, Distribution Transformer, providing necessary gaskets, Oil Seals, cleaning, dusting, decarbonising, tightening loosened parts, including replacing worn out part copper studs, bolts nuts and washers replacing oil Seals, HT bush, gasket including unserviceable coil, replacing of defective minor items such as as and when required complete all as specified and as directed. Note:- The item spare parts oil to be replaced shall be measured and paid separately, However minor items such as GASKET , NUT and bolt shall be deemed to be included in the unit rate. The rates are inclusive of crane charges for lifting and re assembling from the structure.
All as per item No 5 above, but of cap above 250 KVA to 500 KVA , 11 KV rating
All as per item No 5 above, but of cap above 500 KVA to 1000 KVA, 11KV rating
Supply and fix in repair HT bushing rod complete with insulator and packing suitable for out door/Indoor type 63 KVA to 500 KVA, 11KV rating transformers confirming to IS-334 complete with nut bolts brass studs and gasket of synthetic rubber bonded cork sheet all as specified and directed by Engr-in-Charge.
All as per item No- 8 above but of but for cap above 500 KVA and upto 1000 KVA, 11KV rating
Supply and fix in repair LT bushing complete with insulator and packing suitable1100 volt grade complete with nut bolts, brass studs, insulator and gasket etc suitable for 63 to 500 KVA, 11 KV rating out door/Indoor transformer.
All as per item No-10 above, but for above 500 KVA to 1000 KVA, 11KV rating
Notes for item No 05 to 11 : 1. Rates quoted by the contractor shall be deem to include for opening of top plate of transformer/decanning of oil from transformer up the level as per requirement and assemble the same after replacement of bushing rod. 2. Bushing rod shall be replaced at site. transformer will not be allowed to send to workshop at any cost and all bushing replacement work shall be executed at site only.
S&F in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 100 to 315 KVA, 11 KV rating ( 1/2 kgs )transformers complete including connecting with proper rubberized gasket complete all as specified and directed.
S&F in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 500 to 750 KVA, 11 KV rating ( 1 kg) transformers complete including connecting with proper rubberized gasket complete all as specified and directed.
S&F in repair silica gel breather assembly transparent type with first fill of silica gel suitable for 1000 KVA ( 1 kg ) transformers complete including connecting with proper rubberized gasket complete all as specified and directed.
Supply and fix in replacement of silica gel in existing breather assy of any cap of transformer all as specified and directedneider/ABB/L&T ete all as specified and directed.
Material and labour for spray painting of distribution transformer with two coats of synthetic enamel paint of smoke grey colour after neatly cleaning and preparing the surface for spray painting the transformer of the following capacity including writing SM / MES No (5 cm height) with white enamel paint of cap upto 250 KVA, 11KV rating transformer complete all as specified and as directed.
All as per item No 17 above but of cap above 250 KVA and upto 500 KVA, 11 KV rating
All as per item No 17 above but of cap above 500 and upto 1000 KVA, 11 KV rating
M & L for calibration of IDMT relays set of 11KV rating of three through relay test kit inlcuding other required measuring equipment to the site by secondary injection method and testing for proper functioning/tripping systems of relays complete all as specified and as directed. Note : The rate quoted by the contractor is deemed to be included for quarterly checking of relays in VCB/OBC for its proper setting/fuctioning and tripping of VCB/OCB during over load/earth fault.
Supply and fixing of HT current transformer 11 KV rating of capacity 200 / 100 / 5-5 including testing commissioning of through primary injection method with suitable testing kit and also checking the control panel wiring including setting the CT range with relays setting for proper functioning/tripping and taking out old unserviceable CT complete all as specified and as directed.
Supply amd fixing in replacement of moving contact assembly suitable for HT OCB 11 KV 400 Amps to 800Amp OCB including dismantling the old unserviceable moving contact assembly suitable for HT OCB complete all as specified and as directed. Make:as per existing
Supply and fixing in replacement of big and small end bearing of HT 11 KV VCB trolly including replacement of complete locking mechanism with integral spring charging handle for manual spring charge and replacement of closing coil and triping coil 24V DC including replacement of electro magnetic relay, coil rating 230 V, AC of existing sample of make of Crompton greaves/ABB/Schneider.
Supply and fixing in replacement resin encapsulated vacuum interrupter bottles of the same manufacturers as per existing circuit breaker trolley of 11 KV. Make: ABB/Schneider/L&T/CG
Supply and fix in replacement of spring charge universal motor suitable for 11 KV, VCB,working on 230 volt of existing make i.e CG/Schneider/ABB/L&T ete all as specified and directed.
Supply and fixing in replacement of current transformer moulded in epoxy compound with dual ration 50/25/5 Amps complete connection with copper wire including beading as per existing VCB 11 KV at site all as specified and directed by Engr-in charge. Note: Circuit diagram shall be produced by the contractor after fixing the CT in VCB at site. Make: ABB/Schneider/Alstom/crompton.
Supply & Fixing of Tripping coil for 11 KV 400/800 Amp VCB 30/110 V DC including taking out old unserviceable coil complete all as specified and as directed.
Supply & Fixing of Closing coil for 11 KV 400/800 Amp VCB 30/110 V DC including taking out old unserviceable coil complete all as specified and as directed.
Supply & Fix of Master Tripping Relay rating of 24 / 30 / 110 V dc for the existing HT VCB/OCB/RMU 11 KV Panels complete all as specified and as directed, Make: EASUN REYROLLE / C&S
Supply & fix tripping & closing coil with complete assembly for 11 KV SF6 breaker DC 24/30 V 1 including taking out old unserviceable coil assembly, complete all as specified & directed, as per exsiting
Replacement of unserviceable existing make and model IDMT relay numerical non directional over current and earth fault relay with communication feature (RS 485) with full automation system type Argus, LT, Aux voltage 110 volt DC should comprise of the following feature :- (a) Three phase over current and one earth fault (b) High set - low set (c) RS-485 with full communication system (d) Multi characteristic for both over current and earth fault, Make: L&T / SCHNEIDER / SEIMENS / ABB / C&S
Taking down old unserviceable DC power pack, Supply and fix DC power pack, LT, 230 V AC Input & output 110 / 30 V DC for energizing tripping and closing coil installed in VCB/OCB
All as per item No- 34 but 3 way RMU all as specified and directed.
All as per item No- 34 but 4 way RMU all as specified and directed.
All as per item No- 34 but 5 way RMU all as specified and directed.
Supply and fix HT spout bushing for VCB HT 11 KV, busbar side including taking out old unserviceable bushing complete all as specified and directed.
Supply and fix Trip-Neutral-Close (TNC) Switch, fixing with the existing HT VCB/OCB 11 KV Panel for including taking out old unserviceable TNC Switch complete all as specified and as directed. Make: Kaycee
Supply and laying Sealing Compound bitumen for arresting of holes at VCB/OCB/ SF6 Breaker panels 11 KV rating etc
Supply, laying, testing, jointing and commissioning XLPE insulated cable screened PVC bedded, galvanised steelstrip or wirearmoured electric powercable heavy duty with aluminium conductor of size 95 Sqmm 3 core 11000 Volt grade (11 KV earthed) laid in trenches/fixed on poleincluding taking out existing deffective cable . (Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately.
Supply, laying, testing, jointing and commissioning XLPE insulated cable screened PVC bedded, galvanised steelstrip or wirearmoured electric powercable heavy duty with aluminium conductor of size 120 Sqmm 3 core 11000 Volt grade (11 KV earthed) laid in trenches/fixed on poleincluding taking out existing deffective cable . (Note : Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately.
Supply & fixing cable jointing kit for 11 KV grade cable for in door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sq mm including taking out unserviceable joint kit complete all as directed
Supply & fixing cable jointing kit for 11 KV grade cable for in door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 Sq mm including taking out unserviceable joint kit complete all as directed
Supply & Fixing cable jointing kit for 11 KV grade cable for out door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sq mm including taking out unserviceable joint kit complete all as directed
Supply & Fixing cable jointing kit for 11 KV grade cable for out door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 Sq mm including taking out unserviceable joint kit complete all as directed
Supply & Fixing cable jointing kit for 11 KV grade cable for straight through joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sq mm including taking out unserviceable joint kit complete all as directed
Supply & fixing cable jointing kit for 11 KV grade cable for straight through joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 Sq mm including taking out unserviceable joint kit complete all as directed
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 150 Sqmm,Indoor/Outdoor type all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 Sqmm,Indoor/Outdoor type all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil all as directed by Engs-in -charge.
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified all as directed by Engr-in -charge.
Supply and spread soft soil sand duly filtered the sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed.
M & L for un-reinforced pre cast concrete covers class HV type 300mmx 180mm x 40mm size factory made for cable protection complete all as specified and directed.
M & L for filtration of transformer oil through stream line filtration plant for extracting moisture content in the oil and carbon deposits and bringing the di-electric strength not less than 60 KV for one minute with sphere gap of 2.5 mm including checking the value of acidity of oil with a acidity test kit and submitting test report for Die electric strength and acidity of transformer oil before/after filteration complete all as specified and as directed. Note : 1.The contractor should submit the Test sheet for all transformer in which dehydration of transformer oil carried out
Supply and filling of New transformer oil confirming to IS 335-1963 as amended and die electric strength not less than 60 KV for topping up/replacement of unserviceable transformer oil complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried in ground verticallyto a depth not less than 2.25mtrs below normal ground level with top edge of the plate not less than 1.5mtrs below ground level connected to galvanised iron /steel strip of size 32 x 6mm thick by means of bolts, nuts , check nuts and washer made out of ganvanised iron or steel all as shown in electrical plate No-03 of SSR part I and earth strip protected by GI pipe light grade 40mm bore and through test point including necessary earth work and excavation in any type of soil, GI light grade 20 watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab 6mm dia MS bars at 100mm c/c both ways with MS Hooks 6mm dia ms bars etx complete all as specified and directed and testing on completion. Note : GI Strip upto 7.5 Mtr length shall be deemed to include in this items.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and as directed
Material and labour for finding out the cable fault of any size of cable upto 11 KV underground cable (HT and LT and of any capacity of cable with the help of cable fault loacator mounting on vehicle and with nessary disconnection of cable from two ends and making connection by jonting after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessores- (a) Surge Generator with accessories (b) Head Phone(c) Pin Point Set T-505 with accessories(d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor and included in the quoted rate.
Supply and fix in replacement Multi Data Meter, 11 KV, size 96 x 96 mm including taking down the existing one all as specified and as directed. Make: Schneider / L&T / Elmeasure
Supply and fix in replacement Digital Ammeter, 11 KV, size 96 x 96 mm including taking down the existing one all as specified and as directed. Make: Schneider / L&T / Elmeasure
Supply and fix in replacement Digital Voltmeter, 11 KV, size 96 x 96 mm including taking down the existing one all as specified and as directed. Make: Schneider / L&T / Elmeasure
Supply & laying Synthetic Insulating Mat of size 2.00Mtr x 1.00Mtr x 19 mm thick all as specified and directed
Supply and fixing GI pipe light grade 100 mm dia for protection of HT cable under road or on wall all as specified and directed by Engr- in charge.
M&L for cutting of black top cover of existing road up to 1 mtr depth and 60 cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 uptp 30 cm from top of the road surface comple all as directed by EIC.
Supply and fix RED, YELLOW, GREEN, BLUE, AMBER & WHITE LED Indication Lamps Range (24 - 240 V ac/dc) for the existing HT VCB/OCB/RMU 11 KV Panels for including taking out old unserviceable Lamps complete all as specified and as directed
Material and labour for fabricating of sheet metal enclosure made out of 2mm thick CRCA sheet indoor type suitable for mounting Manual draw out ACB of Cap 800 Amp 4 pole 50 KA including aluminium bus bar of suitable size of the ACB 800 Amp including Voltemeter /Ameter including removing of exisrting unservicabel sheet metal enclosure careffuly and making all connection as per existing all as specified and directed by Engr-in- Charge. Notes : Sheet metal enclosure should be CPRI approved.
GURU ENTERPRISES
GS TRADERS
KARTHIK INCORPORATE
Glacier Cooling Solutions Private Limited
Archana Enterprises
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .