| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 CrAdmitted-Finance PLAT NO 943 54TH STREET T V S COLONY ANNANAGAR WEST EXTENSION CHENNAI PIN 600 101 | CHENNAI | CHENNAI | TAMIL NADU | 600101 | ₹11.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.3 CrAdmitted-Finance B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | ₹11.3 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Eco Protection Engineers Pvt Ltd L1 | R K ENGINEERS SALES LTD L2 |
|---|---|---|---|---|---|
| 1.00 | TRANSMISSION PIPELINES
EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc.,
In all soils mixed with boulders of 30cm size upto and exclusive of disintegrated rock, 0 to 2 Mts. Depth | 2,667.46 | Cum | 85 ₹2.7 L | 176 ₹5.5 L |
| 2.00 | EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc.
In disintegrated rock, soft rock, soft shale and medium hard rock comprising of lime stone, sand stone, hard shale, schiest, fissured rock without resorting to blasting. 0 to 2 Mts. Depth | 762.13 | Cum | 103 ₹92,629.28 | 426 ₹3.8 L |
| 3.00 | EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc.
In Hard Rock by Chistelling 0 to 2 Mts. Depth | 381.07 | Cum | 189 ₹84,986.23 | 1,569 ₹7.1 L |
| 4.00 | Providing, erecting and removing casurinapole barricading using poles of 7.5 to 10 cms. dia and 1.5 m height above ground fixed vertically at intervals of 2.0 to 2.5 mtr. c/c and horizontally at 0.5 mtr above ground level, including fixing poles in the ground level for a minimum depth of 0.3mtr. and tied with coir rope firmly including cost and conveyance of all materials, labour, lead and lift charges and complete- Two tier barricading. | 3,550 | RMT | 27 ₹1.1 L | 75 ₹3.1 L |
| 5.00 | Refilling of available earth around pipelines, in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering all lead and lift including cost of all labour including consolidation by mechanical means approved by Engineer in charge, when earth is at suitable moisture content with desired field density upto 95% maximum dry density (modified heavy proctor test) for restoration of roads without settlement including HOM of machineries, complete. (The contractor shall take care while consolidating the earth, so that, pipes laid are not damaged due to mechanical compaction and shall restore the damaged pipes at his own cost, in case of damage). | 4,377.83 | Cum | 22 ₹1.1 L | 109 ₹5.6 L |
| 6.00 | Providing Murrum/ gravel bedding for the pipe line trenches using approved granular material of size less than 25mm (murrum) including watering and consolidation by punners to required density etc., complete with all lead and lifts, as per specification and as directed by the Engineer in charge. Bedding of Water pipes. for Bedding of Water pipes. | 532.5 | Cum | 220 ₹1.4 L | 261 ₹1.6 L |
| 7.00 | Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting Water bound Macadam Surface | 216.11 | Cum | 546 ₹1.4 L | 906 ₹2.3 L |
| 8.00 | Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting Asphalt road | 360.19 | Cum | 568 ₹2.4 L | 943 ₹4.0 L |
| 9.00 | Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting of cement concrete Road | 86.45 | Cum | 1,094 ₹1.1 L | 1,090 ₹1.1 L |
| 10.00 | Disposing off the excess Excavated Earth of all types upto distance mentioned below by vehicle including loading,unloading, with all lifts,labour,HOM of machinary etc. complete 1.0 to 2.0 Km | 4.56 | Cum | 169 ₹909.36 | 140 ₹753.31 |
Tender Value
₹9.1 Cr
EMD Value
₹13.7 L
Closing Date
11 Aug 2022, 3:00 pmClosed
Registrar
IISc Bangalore
Water Supply System Rehabilitation Works Smart Pumping Station Phase II in IISc Bangalore
2022_IISC_700566_1
IISc/Tender-CIV-04/2022-23
Open Tender
Civil Works - Water Works
730 days
IISc CCMD
As per tender Document
2 documents required · 2 mandatory
₹10,000
Registrar
₹13.7 L
Ms Teams Online
14 Nov 2022
14 Jul 2022
12 Aug 2022
15 Jul 2022
11 Aug 2022
20 Jul 2022
18 Jul 2022
Amount
TRANSMISSION PIPELINES EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc., In all soils mixed with boulders of 30cm size upto and exclusive of disintegrated rock, 0 to 2 Mts. Depth
EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc. In disintegrated rock, soft rock, soft shale and medium hard rock comprising of lime stone, sand stone, hard shale, schiest, fissured rock without resorting to blasting. 0 to 2 Mts. Depth
EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc. In Hard Rock by Chistelling 0 to 2 Mts. Depth
Providing, erecting and removing casurinapole barricading using poles of 7.5 to 10 cms. dia and 1.5 m height above ground fixed vertically at intervals of 2.0 to 2.5 mtr. c/c and horizontally at 0.5 mtr above ground level, including fixing poles in the ground level for a minimum depth of 0.3mtr. and tied with coir rope firmly including cost and conveyance of all materials, labour, lead and lift charges and complete- Two tier barricading.
Refilling of available earth around pipelines, in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering all lead and lift including cost of all labour including consolidation by mechanical means approved by Engineer in charge, when earth is at suitable moisture content with desired field density upto 95% maximum dry density (modified heavy proctor test) for restoration of roads without settlement including HOM of machineries, complete. (The contractor shall take care while consolidating the earth, so that, pipes laid are not damaged due to mechanical compaction and shall restore the damaged pipes at his own cost, in case of damage).
Providing Murrum/ gravel bedding for the pipe line trenches using approved granular material of size less than 25mm (murrum) including watering and consolidation by punners to required density etc., complete with all lead and lifts, as per specification and as directed by the Engineer in charge. Bedding of Water pipes. for Bedding of Water pipes.
Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting Water bound Macadam Surface
Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting Asphalt road
Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting of cement concrete Road
Disposing off the excess Excavated Earth of all types upto distance mentioned below by vehicle including loading,unloading, with all lifts,labour,HOM of machinary etc. complete 1.0 to 2.0 Km
Disposing off the excess Excavated Earth of all types upto distance mentioned below by vehicle including loading,unloading, with all lifts,labour,HOM of machinary etc. complete 2.0 to 3.0 Km
Road Reinstatement of Asphalt and concrete roads after leak attending with earth work excavation of compacted oil depositing on bank with alllead and lifts including danger lighting and barricading. Providing, laying, spreading and compacting graded stones aggregate as per wet mix macadam specifications. Applying tack coat on granular base such as WBM and WMM surface hot bitumen primer at 4 kg per 10 sqm, heating bitumen in layer to be laid with boiler fitted with spray set of 300 mm thickness. Above laid with bituminous concrete or M20 concrete premixed with bituminous binder at 5.4 to 5.6% of mix and filler, to achieve the desired compaction to give minimum of 45 mm thickness compacted. The work shall be carried as per leak repair manual and includes all kinds of materials disposing off the excess excavated earth with all lead and lifts by vehicle including loading, unloading, labour, HOM of machinery etc. in a complete manner.
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320 kgs, with 20 mm and down size graded granite metal coarse aggregates @ 0.69 cum and fine aggregates @ 0.460 cum,with super plasticisers @ 3 liters confirming to IS 9103-1999 reaffirmed-2008, machine mixed,concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for Thrust Blocks & Anchor Blocks etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. For Thrust Blocks & Anchor Blocks
Providing, supplying and fabricating of TMT Steel (Fe 500 Grade ) reinforcement of all sizes, for R.C.C. work including straightening, cutting, bending, hooking, lapping and/or welding wherever required, placing in position, tieing with binding wire and anchoring to adjoining members wherever necessary complete as per design (laps and wastages shall not be meassured and paid) including cost of materials, labour , HOM of machinery complete as per specifications. No-KBS 4.6.3 (120.36 kg/Cum). .... For Thrust Blocks & Anchor Blocks
Providing and laying Ductile iron pipes of class-K9 conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches and jointing of pipes to be measured and paid for separately) Note: In sewerage projects for internal cement mortal lining (CML) of DI pipes, if High Alumina Cement (HAC) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement (SRC), the cost of pipes may be increased by 5-6% from the prices listed above. 100 mm Dia DI K-7 Class
Providing and laying Ductile iron pipes of class-K9 conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches and jointing of pipes to be measured and paid for separately) Note: In sewerage projects for internal cement mortal lining (CML) of DI pipes, if High Alumina Cement (HAC) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement (SRC), the cost of pipes may be increased by 5-6% from the prices listed above. 150 mm Dia DI K-9 Class
Providing and laying Ductile iron pipes of class-K9 conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches and jointing of pipes to be measured and paid for separately) Note: In sewerage projects for internal cement mortal lining (CML) of DI pipes, if High Alumina Cement (HAC) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement (SRC), the cost of pipes may be increased by 5-6% from the prices listed above. 200 mm Dia DI K-9 Class
Providing and laying Ductile iron pipes of class-K9 conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches and jointing of pipes to be measured and paid for separately) Note: In sewerage projects for internal cement mortal lining (CML) of DI pipes, if High Alumina Cement (HAC) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement (SRC), the cost of pipes may be increased by 5-6% from the prices listed above. 300 mm Dia DI K-7 Class
Hire charges for 2 HP dewatering pumps to bail out water at leaking pits inclusive of hire charges, cost of fuel, transportation charges, operator charges etc, complete. (per day of 8 hrs shift)
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia 22.5 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia 45 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia 90 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) DI Flanged Spigot
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) DI Flanged Spigot All Socketed DI Equal Tees 100 mm x 100 mm x 100 mm
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 150 mm Dia 22.5 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 150 mm Dia 450 Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 150 mm Dia 900 Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 150 mm Dia DI Flanged Spigot
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 150 mm Dia Double Socket with flanged Branch DI un-equal Tees 150 mm x 150 mm x 100 mm
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 150 mm Dia All Socketed DI Equal Tees 150 mm x 150 mm x 150 mm
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 200 mm Dia 22.5 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 200 mm Dia 45 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 200 mm Dia 90 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 200 mm Dia DI Flanged Spigot
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 200 mm Dia Double Socket with flanged Branch DI un-equal Tees 200 mm x 200 mm x 100 mm
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 200 mm Dia All Socketed DI Equal Tees 200 mm x 200 mm x 200 mm
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 300 mm Dia 22.5 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 300 mm Dia 45 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 300 mm Dia 90 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 300 mm Dia DI Flanged Spigot
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 300 mm Dia Double Socket with flanged Branch DI un-equal Tees 300 mm x 300 mm x 100 mm
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 300 mm Dia All Socketed DI Equal Tees 300 mm x 300 mm x 300 mm
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Soc-Spigot Fittings upto 400mm 22.5 degree Bend
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Soc-Spigot Fittings upto 400mm 45 degree Bend
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Soc-Spigot Fittings upto 400mm 90 degree Bend
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Flanged Spigot upto 400 mm
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. Double Socket with flanged Branch DI un-equal Tees upto 400 mm x 400 mm x 100 mm
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. All Socketed DI Equal Tees upto 400 mm x 400 mm x 400 mm
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 100 mm PN 1.6 for line Isolation Purpose
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 150 mm PN 1.6 for line Isolation Purpose
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 200 mm PN 1.6 for line Isolation Purpose
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 300 mm PN 1.6 for line Isolation Purpose
Supply,installation,testing & Commissioning of Tamper Proof Triple Function Single/Double chamber Kinetic Air Valve MOC: Body & Top Cover:Ductile Iron Gr. GGG40/ GGG-50, Float/Balls: SS 304,Cover Bolts: SS316, Gaskets & Seals:EPDM with Epoxy powder coating (EP-P) shall be provided inside and outside with colour blue RAL 5005 Flange Ends.All the valves should be with Electro static power coating both inside and outside with pocket less body passagewith all necessary mounting stub mating flanges,bolts & Gaskets, cost of necessary mating flanges,bolts & Gaskets shall be inclusive(1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation.) 80 mm PN 1.6 on Pumping main for Air release valve arrangement
Integration of Exisitng Pipes Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores). Note : Only 75% rate shall be payable till satisfactory hydraulic testing is given. 100mm
Integration of Exisitng Pipes Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores). Note : Only 75% rate shall be payable till satisfactory hydraulic testing is given. 150mm
Integration of Exisitng Pipes Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores). Note : Only 75% rate shall be payable till satisfactory hydraulic testing is given. 200mm
Integration of Exisitng Pipes Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores). Note : Only 75% rate shall be payable till satisfactory hydraulic testing is given. 300mm
DISTRIBUTION PIPELINES EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc., In all soils mixed with boulders of 30cm size upto and exclusive of disintegrated rock, 0 to 2 Mts. Depth
EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc. In disintegrated rock, soft rock, soft shale and medium hard rock comprising of lime stone, sand stone, hard shale, schiest, fissured rock without resorting to blasting. 0 to 2 Mts. Depth
EXCAVATING FOR PIPE LINE TRENCHES OF REQUIRED WIDTH by manual means including dressing sides, ramming of bottoms, providing barricading, danger lighting, shoring, strutting, dewatering, etc. In Hard Rock by Chistelling 0 to 2 Mts. Depth
Providing, erecting and removing casurinapole barricading using poles of 7.5 to 10 cms. dia and 1.5 m height above ground fixed vertically at intervals of 2.0 to 2.5 mtr. c/c and horizontally at 0.5 mtr above ground level, including fixing poles in the ground level for a minimum depth of 0.3mtr. and tied with coir rope firmly including cost and conveyance of all materials, labour, lead and lift charges and complete- Two tier barricading.
Refilling of available earth around pipelines, in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering all lead and lift including cost of all labour including consolidation by mechanical means approved by Engineer in charge, when earth is at suitable moisture content with desired field density upto 95% maximum dry density (modified heavy proctor test) for restoration of roads without settlement including HOM of machineries, complete. (The contractor shall take care while consolidating the earth, so that, pipes laid are not damaged due to mechanical compaction and shall restore the damaged pipes at his own cost, in case of damage).
Providing Murrum/ gravel bedding for the pipe line trenches using approved granular material of size less than 25mm (murrum) including watering and consolidation by punners to required density etc., complete with all lead and lifts, as per specification and as directed by the Engineer in charge. Bedding of Water pipes. for Bedding of Water pipes.
Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting Water bound Macadam Surface
Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting Asphalt road
Cutting road surface for pipeline trenches and disposing off the excavated stuff as directed by the Engineer including barricading, danger lighting etc., in the following classifications. Cutting of cement concrete Road
Disposing off the excess Excavated Earth of all types upto distance mentioned below by vehicle including loading,unloading, with all lifts,labour,HOM of machinary etc. complete 1.0 to 2.0 Km
Disposing off the excess Excavated Earth of all types upto distance mentioned below by vehicle including loading,unloading, with all lifts,labour,HOM of machinary etc. complete 2.0 to 3.0 Km
Road Reinstatement of Asphalt and concrete roads after leak attending with earth work excavation of compacted oil depositing on bank with alllead and lifts including danger lighting and barricading. Providing, laying, spreading and compacting graded stones aggregate as per wet mix macadam specifications. Applying tack coat on granular base such as WBM and WMM surface hot bitumen primer at 4 kg per 10 sqm, heating bitumen in layer to be laid with boiler fitted with spray set of 300 mm thickness. Above laid with bituminous concrete or M20 concrete premixed with bituminous binder at 5.4 to 5.6% of mix and filler, to achieve the desired compaction to give minimum of 45 mm thickness compacted. The work shall be carried as per leak repair manual and includes all kinds of materials disposing off the excess excavated earth with all lead and lifts by vehicle including loading, unloading, labour, HOM of machinery etc. in a complete manner.
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320 kgs, with 20 mm and down size graded granite metal coarse aggregates @ 0.69 cum and fine aggregates @ 0.460 cum,with super plasticisers @ 3 liters confirming to IS 9103-1999 reaffirmed-2008, machine mixed,concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for Thrust Blocks & Anchor Blocks etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification no. KSRB 4.1, 4.6.., For Thrust Blocks & Anchor Blocks
Providing, supplying and fabricating of TMT Steel (Fe 500 Grade ) reinforcement of all sizes, for R.C.C. work including straightening, cutting, bending, hooking, lapping and/or welding wherever required, placing in position, tieing with binding wire and anchoring to adjoining members wherever necessary complete as per design (laps and wastages shall not be meassured and paid) including cost of materials, labour , HOM of machinery complete as per specifications. No-KBS 4.6.3 (120.36 kg/Cum). .... For Thrust Blocks & Anchor Blocks
Providing fusion welding Jointing for HDPE Pipes Grade PE-80/ PE-100 conforming to IS 4984-1995, of specified dia. etc. for: HDPE Grade PE80 Pipes 90 mm dia
Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 25 mm nominal OD Pipe
Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 40mm nominal OD Pipe
Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 50mm nominal OD Pipe
PVC SPECIALS AS PER IS 10124/1982 Part-II Providing PVC specials for fixing of water meter horizontally. 25mm PVC Couplers (Mould) BIS 7834/1975 Part VI
PVC SPECIALS AS PER IS 10124/1982 Part-II Providing PVC specials for fixing of water meter horizontally. 25mm PVC Elbow (Mould) BIS 7834/1975 Part VI
PVC SPECIALS AS PER IS 10124/1982 Part-II Providing PVC specials for fixing of water meter horizontally. 25mm PVC Equal tee (Mould) BIS 7834/1975
PVC SPECIALS AS PER IS 10124/1982 Part-II Providing PVC specials for fixing of water meter horizontally. 25mm PVC End Cap
Providing and laying Ductile iron pipes of class-K7 conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc., and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches and jointing of pipes to be measured and paid for separately) Note: In sewerage projects for internal cement mortal lining (CML) of DI pipes, if High Alumina Cement (HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement (SRC), the cost of pipes may be increased by 5-6% from the prices listed above. 100 mm Dia DI K-7 Class
Hire charges for dewatering pumps to bail out water at leaking pits inclusive of hire charges, cost of fuel, transportation charges, operator charges etc, complete. (per day of 8 hrs shift)
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia 22.5 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia 45 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia 90 degree Bend
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia DI Flanged Spigot
Supply, delivery of DI push on specials & conforming to as per IS 9523: 2000 and as directed by the Engineer. (Note : The Rates are inclusive of all taxes, duties & transportation charges) 100 mm Dia All Socketed DI Equal Tees 100 mm x 100 mm x 100 mm
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Soc-Spigot Fittings 100 mm 22.5 degree Bend
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Soc-Spigot Fittings 100 mm 45 degree Bend
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Soc-Spigot Fittings 100 mm 90 degree Bend
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. DI Flanged Spigot 100 mm
Fixing CI / DI specials of mechanical jointing of different sizes after setting into the pipe line system, including cleaning, introducing rubber gasket to proper alignment and lightening with bolts and nuts. The cost includes transportation of materials, tools and plants etc. The CI / DI mechanical specials with bolts, nuts, washers and rubber gaskets etc. will be supplied free of cost by the Board. All Socketed DI Equal Tees 100 mm x 100 mm x 100 mm
Supply and Delivery of Resilent seated soft sealing Sluice valves with body, bonnet of ductile iron of grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/ IS 14846-2000 / DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS. 80 mm PN 1.6 for line Isolation Purpose
Supply and Delivery of Resilent seated soft sealing Sluice valves with body, bonnet of ductile iron of grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face dimensions as per BS 5163-89/ IS 14846-2000 / DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS. 100 mm PN 1.6 for line Isolation Purpose
Integration of Exisitng Pipes Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline,irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores). Note : Only 75% rate shall be payable till satisfactory hydraulic testing is given. 80mm
Integration of Exisitng Pipes Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores). Note : Only 75% rate shall be payable till satisfactory hydraulic testing is given. 100mm
ELECTRIC ACTUATOR VALVES Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 100 mm PN 1.6 Rating
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 150 mm PN 1.6 Rating
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. 200 mm PN 1.6 Rating
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter for ON & OFF operation. 100 mm PN 1.6 Rating
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter for ON & OFF operation. 150 mm PN 1.6 Rating
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter for ON & OFF operation. 200 mm PN 1.6 Rating
Manufacturing, providing, transporting, rolling, lowering, laying & Jointing, testing, commissioning of MS specials confirming to IS 7322 : 1985 with latest amendments, perfect linking and welding of joints to correct position including cost and conveyance of materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589 :2001 with latest amendments for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with inside & outside lining two coats of food grade epoxy painting of approved make with minimum 250 micron, thick over one coat of food grade epoxy primer of approved make with minimum of 50 micron thick or only for outside 25 mm thick coating in CM 1:3 by providing 50 x50 mm weld mesh including loading and unloading of pipes for the following category to suit PSC/MS/CI/AC/DI/PVC pipes. The rates are inclusive of all taxes and duties. The weight of the MS shell only be considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer (Contractor will make his own arrangements for procuring water for testing). For bends, Tee pieces,Reducers & Flanges & Blank Flanges upto & inclusive of 500mm dia of pipe
VALVE CHAMBERS Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications and drawings with all lead for following depth Flow meter Valve chamber (200-300mm dia pipe) 0 to 1.5 m depth (100% Ordinary Soil)
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications and drawings with all lead for following depth Flow meter Valve chamber (200-300mm dia pipe) 1.5 to 3 m depth (60% Ordinary Soil)
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications and drawings with all lead for following depth Flow meter Valve chamber (200-300mm dia pipe) 1.5 to 3 m depth (40% hard Soil)
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications and drawings with all lead for following depth Flow meter Valve chamber (80-150mm dia pipe) 0 to 1.5 m depth (100% Ordinary Soil)
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications and drawings with all lead for following depth Flow meter Valve chamber (80-150mm dia pipe) 1.5 to 3 m depth (60% Ordinary Soil)
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications and drawings with all lead for following depth Flow meter Valve chamber (80-150mm dia pipe) 1.5 to 3 m depth (40% hard Soil)
Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. Specification. No. KBS 2.9 Backfill
Providing and laying in position plain cement concrete of Mix 1:3:6 with OPC @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.69 cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications. PCC Flow meter Valve chamber (200-300mm dia pipe)
Providing and laying in position plain cement concrete of Mix 1:3:6 with OPC @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.69 cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications. PCC Flowmeter Valve chamber (80-150mm dia pipe)
Providing and laying in position reinforced cement concrete of design Mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels, and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM curing, complete but excluding cost of reinforcement as per specifications. RCC Flow meter Valve chamber (200-300mm dia pipe)
Providing and laying in position reinforced cement concrete of design Mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels, and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM curing, complete but excluding cost of reinforcement as per specifications. RCC Flowmeter Valve chamber (80-150mm dia pipe)
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM complete as per Specifications. Specification No. KBS 4.6.3 Steel Flow meter Valve chamber (200-300mm dia pipe)
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM complete as per Specifications. Steel Flowmeter Valve chamber (80-150mm dia pipe)
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as per specifications. Shuttering Flow meter Valve chamber (200-300mm dia pipe)
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as per specifications. Shuttering Flowmeter Valve chamber (80-150mm dia pipe)
Providing cast iron footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 Flow meter Valve chamber (200-300mm dia pipe)
Providing cast iron footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Flowmeter Valve chamber (80-150mm dia pipe)
CI Manhole cover with frame 610x455 mm size (38kgs)
FOR 70,000 LITRES UG SUMP AT CD MESS Earthwork excavation by manual means for foundation of buildings, water supply sanitary lines and electrical conduits etc., either in pits or in trenches 1.50m and above in width, in soil not exceeding 1.5m including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from the edges of excavation with lead upto 50m including breaking of clods complete as per specifications. -in ordinary soil 0 to 1.5 m depth
Earthwork excavation by manual means for foundation of buildings, water supply sanitary lines and electrical conduits etc., either in pits or in trenches 1.50m and above in width, in soil not exceeding 1.5m including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from the edges of excavation with lead upto 50m including breaking of clods complete as per specifications. -in ordinary soil 1.5 to 3 m depth
Earthwork excavation by manual means for foundation of buildings, water supply sanitary lines and electrical conduits etc., either in pits or in trenches 1.50m and above in width, in soil not exceeding 1.5m including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from the edges of excavation with lead upto 50m including breaking of clods complete as per specifications. -in ordinary soil 3m to 4.5m depth
Loading and Unloading of Stone Boulder / Stone aggregates /Sand/ Kanker / Moorum. Placing tipper at loading point, loading with front end loader,dumping, turning for return trip, excluding time for haulage and return trip complete as per specifications.
Disposing off the excess excavated Earth of all types upto a distance mentioned below by vehicle including loading, unloading, with all lifts, labour,HOM of machinery etc. complete. - lead upto 5km
Compaction of original ground by mechanical means including filling in depression occuring during rolling including cost of all labour, HOM complete as per specifications.
Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregates @0.465cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM curing complete as per specifications.
Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-30
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Reservoir base slab
Providing and removing centering, shuttering, strutting, propping etc. and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttesses, plinth and string courses cost of all materials, labour complete as per specifications. Level from 0.00 to 3.50m
Providing and removing centering, shuttering, strutting, propping etc. and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttesses, plinth and string courses cost of all materials, labour complete as per specifications. Level from 3.50 to 4.50m
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications. 0 to 5 mts
Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Providing and filling polysulphide rubberised sealing compound or equivalent (Sealant Type A) in a groove of size 15 mm x 20 mm deep at contraction joints including forming groove as specified on drawing for Ground level reservoir.
Providing and fixing 225 mm wide and minimum 6 mm thick continuous PVC waterstops of approved quality at contraction and expansion joints as per manufacturer's instructions at all levels for Ground level reservoir.
Providing and finishing external walls in two coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. Reservoir
Providing and laying 500 gauge polyethylene sheet of approved make and quality on blinding layer and wherever specified as directed by Engineer, for Ground level reservoir.
Providing and fixing slip-strip (1 mm thick PVC sheet) of approved quality or equivalent at junction between top of wall and bottom of roof slab in two layers as directed by Engineer, for Ground level reservoir.
Providing and fixing 150 mm diameter cast iron air ventilators as per design & shape indicated in drawings over roof slab of all reservoirs with mosquito proof jali etc complete. Market Rate
Providing and laying M15 grade plain concrete in screed for required level above roofs to specified slope with coarse aggregate of size 10 mm downgraded, including formwork and compacting with a hand rammer, curing, finishing, etc. complete.
Providing and filling polysulphide rubberised sealing compound or equivalent (Sealant type B) in a groove of size 25 mm x 20 mm deep at expansion joints including forming groove as specified on drawing for Ground level reservoir.
Providing and laying water proof course, 100mm thick average, including compaction, laying to slope, curing etc complete as per specifications.
FOR 30,000 LITRES UG SUMP AT U-BLOCK Earthwork excavation by manual means for foundation of buildings, water supply sanitary lines and electrical conduits etc., either in pits or in trenches 1.50m and above in width, in soil not exceeding 1.5m including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from the edges of excavation with lead upto 50m including breaking of clods complete as per specifications. -in ordinary soil 0 to 1.5 m depth
Earthwork excavation by manual means for foundation of buildings, water supply sanitary lines and electrical conduits etc., either in pits or in trenches 1.50m and above in width, in soil not exceeding 1.5m including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from the edges of excavation with lead upto 50m including breaking of clods complete as per specifications. -in ordinary soil 1.5 to 3 m depth
Loading and Unloading of Stone Boulder / Stone aggregates /Sand/ Kanker / Moorum. KSRRB M100-1 : Placing tipper at loading point, loading with front end loader,dumping, turning for return trip, excluding time for haulage and return trip complete as per specifications.
Disposing off the excess excavated Earth of all types upto a distance mentioned below by vehicle including loading, unloading, with all lifts, labour,HOM of machinery etc. complete. - lead upto 5km
Compaction of original ground by mechanical means including filling in depression occuring during rolling including cost of all labour, HOM complete as per specifications.
CONCRETE AND ALLIED WORKS Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregates @0.465cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM curing complete as per specifications.
Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-30
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Reservoir base slab
Providing and removing centering, shuttering, strutting, propping etc. and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttesses, plinth and string courses cost of all materials, labour complete as per specifications. Level from 0.00 to 3.50m
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications. 0 to 5 mts
Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Providing and filling polysulphide rubberised sealing compound or equivalent (Sealant Type A) in a groove of size 15 mm x 20 mm deep at contraction joints including forming groove as specified on drawing for Ground level reservoir.
Providing and fixing 225 mm wide and minimum 6 mm thick continuous PVC waterstops of approved quality at contraction and expansion joints as per manufacturer's instructions at all levels for Ground level reservoir.
GENERAL BUILDING WORKS Providing and finishing external walls in two coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications.Reservoir
Providing and laying 500 gauge polyethylene sheet of approved make and quality on blinding layer and wherever specified as directed by Engineer, for Ground level reservoir.
Providing and fixing slip-strip (1 mm thick PVC sheet) of approved quality or equivalent at junction between top of wall and bottom of roof slab in two layers as directed by Engineer, for Ground level reservoir.
Providing and fixing 150 mm diameter cast iron air ventilators as per design & shape indicated in drawings over roof slab of all reservoirs with mosquito proof jali etc complete. Market Rate
Providing and laying M15 grade plain concrete in screed for required level above roofs to specified slope with coarse aggregate of size 10 mm downgraded, including formwork and compacting with a hand rammer, curing, finishing, etc. complete.
Providing and filling polysulphide rubberised sealing compound or equivalent (Sealant type B) in a groove of size 25 mm x 20 mm deep at expansion joints including forming groove as specified on drawing for Ground level reservoir.
Providing and laying water proof course, 100mm thick average, including compaction, laying to slope, curing etc complete as per specifications.
PUMP HOUSE FOR CHEMICAL SCIENCES Excavation Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications.
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications. 1.5-3m
PCC Providing and laying in position plain cement concrete of mix 1:3:6 with OPC @ 220kgs, with 20mm and downsize graded granite metal coarse aggregates @0.69cum and fine aggregates @0.56cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.
Formwork Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for columns, pillars, piers, abutments, post and struts, square/rectangular/polygon in plan including cost of all materials, labour complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications.0-5mts
RCC Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-25
Steel (CRS Bars) Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Concrete Block Wall Providing and constructing non load bearing wall with cement concrete solid blocks with compressive strength not less than 35 Kg/Sqm with cement mortar 1:4 (Jamp, closer block) with blocks of size 40x10x20 cms(lxbxh) confirming to IS:2185/1965 in superstructure including cost of materials, labour charges, scafolloding, curing complete as per specifications.
Plastering Providing 12mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing 20mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Painting Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
Providing and finishing external walls in two coats with waterproof paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials, labour complete as per specifications
Flooring Providing and laying M-15 cement concrete flooring 60 mm thick with metallic concrete hardner topping, under layer of 45mm thick M-15 cement concrete using broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt), including finishing, cost of materials, labour, curing, complete as per specifications.
Doors Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. 7.17.1 -do- using aluminium section anodized to 12 - 15 microns.
Windows &Ventilators Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. With 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS- do- using aluminium section anodized to 12 - 15 microns.
Rolling Shutter Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM complete as per specifications. Shutter size 3mx2.8 m
Water proofing at top of roof Providing and laying six courses water proofing treatment with bitumen felt over roof consisting of first, third and fifth courses of blown and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses of roofing felt Type -2 grade-I (fibre based self finish bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface, excluding grading but including cost of materials, labour complete as per specifications.
Providing & laying boulders including cost of labour complete as per specifications.
PUMP HOUSE FOR 500 ROOMS LADIES HOSTEL Excavation Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications.
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications. 1.5-3m
PCC Providing and laying in position plain cement concrete of mix 1:3:6 with OPC @ 220kgs, with 20mm and downsize graded granite metal coarse aggregates @0.69cum and fine aggregates @0.56cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.
Formwork Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for columns, pillars, piers, abutments, post and struts, square/rectangular/polygon in plan including cost of all materials, labour complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications.0-5mts
RCC Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-25
Steel (CRS Bars) Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Concrete Block Wall Providing and constructing non load bearing wall with cement concrete solid blocks with compressive strength not less than 35 Kg/Sqm with cement mortar 1:4 (Jamp, closer block) with blocks of size 40x10x20 cms(lxbxh) confirming to IS:2185/1965 in superstructure including cost of materials, labour charges, scafolloding, curing complete as per specifications.
Plastering Providing 12mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing 20mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Painting Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
Providing and finishing external walls in two coats with waterproof paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials, labour complete as per specifications
Flooring Providing and laying M-15 cement concrete flooring 60 mm thick with metallic concrete hardner topping, under layer of 45mm thick M-15 cement concrete using broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt), including finishing, cost of materials, labour, curing, complete as per specifications.
Doors Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. 7.17.1 -do- using aluminium section anodized to 12 - 15 microns.
Windows &Ventilators Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. With 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS- do- using aluminium section anodized to 12 - 15 microns.
Rolling Shutter Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM complete as per specifications. Shutter size 3mx2.8 m
Water proofing at top of roof Providing and laying six courses water proofing treatment with bitumen felt over roof consisting of first, third and fifth courses of blown and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses of roofing felt Type -2 grade-I (fibre based self finish bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface, excluding grading but including cost of materials, labour complete as per specifications.
Providing & laying boulders including cost of labour complete as per specifications.
PUMP HOUSE FOR CVH Excavation Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications.
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications. 1.5-3m
PCC Providing and laying in position plain cement concrete of mix 1:3:6 with OPC @ 220kgs, with 20mm and downsize graded granite metal coarse aggregates @0.69cum and fine aggregates @0.56cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.
Formwork Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for columns, pillars, piers, abutments, post and struts, square/rectangular/polygon in plan including cost of all materials, labour complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications.0-5mts
RCC Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-25
Steel (CRS Bars) Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Concrete Block Wall Providing and constructing non load bearing wall with cement concrete solid blocks with compressive strength not less than 35 Kg/Sqm with cement mortar 1:4 (Jamp, closer block) with blocks of size 40x10x20 cms(lxbxh) confirming to IS:2185/1965 in superstructure including cost of materials, labour charges, scafolloding, curing complete as per specifications.
Plastering Providing 12mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing 20mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Painting Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
Providing and finishing external walls in two coats with waterproof paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials, labour complete as per specifications
Flooring Providing and laying M-15 cement concrete flooring 60 mm thick with metallic concrete hardner topping, under layer of 45mm thick M-15 cement concrete using broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt), including finishing, cost of materials, labour, curing, complete as per specifications.
Doors Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. 7.17.1 -do- using aluminium section anodized to 12 - 15 microns.
Windows &Ventilators Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. With 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS- do- using aluminium section anodized to 12 - 15 microns.
Rolling Shutter Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM complete as per specifications. Shutter size 3mx2.8 m
Water proofing at top of roof Providing and laying six courses water proofing treatment with bitumen felt over roof consisting of first, third and fifth courses of blown and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses of roofing felt Type -2 grade-I (fibre based self finish bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface, excluding grading but including cost of materials, labour complete as per specifications.
Providing & laying boulders including cost of labour complete as per specifications.
PUMP HOUSE FOR MGH Excavation Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications.
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications. 1.5-3m
PCC Providing and laying in position plain cement concrete of mix 1:3:6 with OPC @ 220kgs, with 20mm and downsize graded granite metal coarse aggregates @0.69cum and fine aggregates @0.56cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.
Formwork Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for columns, pillars, piers, abutments, post and struts, square/rectangular/polygon in plan including cost of all materials, labour complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications.0-5mts
RCC Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-25
Steel (CRS Bars) Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Concrete Block Wall Providing and constructing non load bearing wall with cement concrete solid blocks with compressive strength not less than 35 Kg/Sqm with cement mortar 1:4 (Jamp, closer block) with blocks of size 40x10x20 cms(lxbxh) confirming to IS:2185/1965 in superstructure including cost of materials, labour charges, scafolloding, curing complete as per specifications.
Plastering Providing 12mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing 20mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Painting Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
Providing and finishing external walls in two coats with waterproof paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials, labour complete as per specifications
Flooring Providing and laying M-15 cement concrete flooring 60 mm thick with metallic concrete hardner topping, under layer of 45mm thick M-15 cement concrete using broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt), including finishing, cost of materials, labour, curing, complete as per specifications.
Doors Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. 7.17.1 -do- using aluminium section anodized to 12 - 15 microns.
Windows &Ventilators Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. With 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS- do- using aluminium section anodized to 12 - 15 microns.
Rolling Shutter Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM complete as per specifications. Shutter size 3mx2.8 m
Water proofing at top of roof Providing and laying six courses water proofing treatment with bitumen felt over roof consisting of first, third and fifth courses of blown and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses of roofing felt Type -2 grade-I (fibre based self finish bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface, excluding grading but including cost of materials, labour complete as per specifications.
Providing & laying boulders including cost of labour complete as per specifications.
PUMP HOUSE FOR S block Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications.
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications. 1.5-3m
Providing and laying in position plain cement concrete of mix 1:3:6 with OPC @ 220kgs, with 20mm and downsize graded granite metal coarse aggregates @0.69cum and fine aggregates @0.56cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for columns, pillars, piers, abutments, post and struts, square/rectangular/polygon in plan including cost of all materials, labour complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications.0-5mts
Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-25
Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Providing and constructing non load bearing wall with cement concrete solid blocks with compressive strength not less than 35 Kg/Sqm with cement mortar 1:4 (Jamp, closer block) with blocks of size 40x10x20 cms(lxbxh) confirming to IS:2185/1965 in superstructure including cost of materials, labour charges, scafolloding, curing complete as per specifications.
Providing 12mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing 20mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
Providing and finishing external walls in two coats with waterproof paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials, labour complete as per specifications
Providing and laying M-15 cement concrete flooring 60 mm thick with metallic concrete hardner topping, under layer of 45mm thick M-15 cement concrete using broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt), including finishing, cost of materials, labour, curing, complete as per specifications.
Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. 7.17.1 -do- using aluminium section anodized to 12 - 15 microns.
Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. With 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS- do- using aluminium section anodized to 12 - 15 microns.
Rolling Shutter Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM complete as per specifications. Shutter size 3mx2.8 m
Providing and laying six courses water proofing treatment with bitumen felt over roof consisting of first, third and fifth courses of blown and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses of roofing felt Type -2 grade-I (fibre based self finish bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface, excluding grading but including cost of materials, labour complete as per specifications.
Providing & laying boulders including cost of labour complete as per specifications.
Pump House For U Block Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications.
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, staking the excavated soil clear from edges of excavation with lead upto 50m after breaking of clods complete as per specifications. 1.5-3m
Providing and laying in position plain cement concrete of mix 1:3:6 with OPC @ 220kgs, with 20mm and downsize graded granite metal coarse aggregates @0.69cum and fine aggregates @0.56cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for columns, pillars, piers, abutments, post and struts, square/rectangular/polygon in plan including cost of all materials, labour complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications
Providing and removing centering, shuttering, strutting, propping etc and removal of form work for flat surface such as suspended floors, roofs, landing, balconies and likes thickness upto 200 mm including cost of all materials, labours, complete as per specifications.0-5mts
Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., for all super structure works with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).Ready mixed Cement concrete M-25
Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications.TMT bars Fe 500
Providing and constructing non load bearing wall with cement concrete solid blocks with compressive strength not less than 35 Kg/Sqm with cement mortar 1:4 (Jamp, closer block) with blocks of size 40x10x20 cms(lxbxh) confirming to IS:2185/1965 in superstructure including cost of materials, labour charges, scafolloding, curing complete as per specifications.
Providing 12mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing 20mm Thick cement plaster in single coat with cement mortar 1:4 including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
Providing and finishing external walls in two coats with waterproof paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material free from mortar drops and other foreign matter cost of materials, labour complete as per specifications
Providing and laying M-15 cement concrete flooring 60 mm thick with metallic concrete hardner topping, under layer of 45mm thick M-15 cement concrete using broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement hardner consisting of mix 1:2 (1 cement hardner mix : 2 granite metal 10mm nominal size) by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt), including finishing, cost of materials, labour, curing, complete as per specifications.
Doors Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred corners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM complete as per specifications. 7.17.1 -do- using aluminium section anodized to 12 - 15 microns.
Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. With 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS- do- using aluminium section anodized to 12 - 15 microns.
Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM complete as per specifications. Shutter size 3mx2.8 m
Providing and laying six courses water proofing treatment with bitumen felt over roof consisting of first, third and fifth courses of blown and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses of roofing felt Type -2 grade-I (fibre based self finish bitumen felt) and sixth and final course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface, excluding grading but including cost of materials, labour complete as per specifications.
Providing & laying boulders including cost of labour complete as per specifications.
CIVIL REHABILITATION WORKS Thermal Pump House (27 x 27 x 3.5) Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications.
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
TPS Sump (1 L Capacity - 8Ø & 4m Depth)_Tank No 1 Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
TPS Sump (1 L Capacity - 8Ø & 4m Depth)_Tank No 2 Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
Main Pump House OHT Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - do- with primer
Lift charges: The above rates are applicable for Ground floor. An additional rate of Rs. -------- per floor for painting works of exterior walls only may be added for every additional floor. STAGING I
Lift charges: The above rates are applicable for Ground floor. An additional rate of . Rs. -------- per floor for painting works of exterior walls only may be added for every additional floor. STAGING II
Lift charges: The above rates are applicable for Ground floor. An additional rate of Rs. -------- per floor for painting works of exterior walls only may be added for every additional floor. STAGING III
Lift charges: The above rates are applicable for Ground floor. An additional rate of Rs. -------- per floor for painting works of exterior walls only may be added for every additional floor. STAGING IV
Lift charges: The above rates are applicable for Ground floor. An additional rate of Rs. -------- per floor for painting works of exterior walls only may be added for every additional floor. WALL, BASE SLAB, CEILING
Scaffolding charges : An additional rate of Rs. -------- for painting works of exterior walls only maybe added for every additional floor. STAGING I
Scaffolding charges : An additional rate of Rs. -------- for painting works of exterior walls only maybe added for every additional floor. STAGING II
Scaffolding charges : An additional rate of Rs. -------- for painting works of exterior walls only maybe added for every additional floor. STAGING III
Scaffolding charges : An additional rate of Rs. -------- for painting works of exterior walls only maybe added for every additional floor. STAGING IV
Scaffolding charges : An additional rate of Rs. -------- for painting works of exterior walls only maybe added for every additional floor. WALL, BASE SLAB, CEILING
New Girls Hostel Sump ( 10.36 x 5.48 x 3.96) Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
New boys Hostel Sump ( 13 x 11 x 3.1) Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
C Mess Sump ( 12m Dia & 4M height) Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
R Block Sump ( 8m Dia & 4M height) Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
KSRB 24-1 : Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
Aero Space Sump( 20 x 6 x 4) Clearing grass and removal of rubbish by manual means and stacking outside the periphery of the area cleaned complete as per specifications. MORTH Specification No. 201
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 0 - 600mm
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions / pit, labour charges complete as per specifications. MORTH specification clause 201/ Chapter 2 600mm to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. KSRRB M200-12.3. –do– C. Prestressed / Reinforced cement concrete grade M-20 above.
Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches, including cost of material, labour, complete as per specifications. Specification No.KBS Sqm 7.00
Providing and laying cement concrete M30 using 20mm and down size granite coarse aggregates and fine of ready mixed concrete for R.C.C. works laid in 15 cms thick layers and well compacted including vibrating, curing etc., with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges).
Providing TMT steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. - do- TMT bars Fe 500
Providing 12mm thick cement plaster in single coat with cement mortar, to ceiling including rounding off corners wherever required smooth rendering, including providing and removing scaffolding, cost of materials, labour, curing etc., complete as per specification. KSRB15-3.13 : – do – cement mortar 1:3
Providing and finishing external walls in one coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. do- with primer
Cleaning RCC sump tanks and RCC overhead tanks with mechanical dewatering including removal of sludge, mud, dirt, algea etc and cleaning the wall surface of tanks using high pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling surfaces and UV treatment, including removing of sludge etc., using suitable coconut broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs, dewatering using motor with portal arrangement, hose pipe etc., complete including all safety measures.
Providing and applying water proofing to concrete surfaces using crystalline capilary water proofing system at 1 kg per sqm for concrete surfaces (confirming to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer based cementatious coating. This crystalline water proofing compound in powder form shall be mixed with water at 3:1 ratio (3 Powder : 1 Water) at the time of application. (Water retaining Structures)
ELECTRICAL ITEMS WORK HE Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 200 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
10HP / 7.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 10 HP/7.5kW motor, 16A TP, 11-16A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 10 HP / 7.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (4 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
1.1kV Cables Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx6 sq.mm, (For 10 HP Motors)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 2Cx2.5 sq.mm, (for 1-Ph Loads, PLC, UPS)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 10 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCC & 10HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc. 12 SWG (Lighting and Receptacles & Motorised Valves)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
P' Block Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
1HP / 0.75kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 1 HP/075kW motor, 2.5A TP, 1.6-2.5A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (1 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx2.5 sq.mm, Al, XLP Arm. Cables (For 1.0 Hp Motor)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 1.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Lighting, and 1.0 HP Motor)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
Physical Sciences Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 200 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
10HP / 7.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 10 HP/7.5kW motor, 16A TP, 11-16A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 10 HP / 7.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (4 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
1.1kV Cables Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx6 sq.mm, (For 10 HP Motors)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 2Cx2.5 sq.mm, (for 1-Ph Loads, PLC, UPS)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 10 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCC & 10HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc. 12 SWG (Lighting and Receptacles & Motorised Valves)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB)Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
New Chemical Sciences Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 125 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
10HP / 7.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 10 HP/7.5kW motor, 16A TP, 11-16A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 10 HP / 7.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (4 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
1.1kV Cables Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx6 sq.mm, (For 10 HP Motors)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 2Cx2.5 sq.mm, (for 1-Ph Loads, PLC, UPS)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 10 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCC & 10HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc. 12 SWG (Lighting and Receptacles & Motorised Valves)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
CVH Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
5HP / 3.7kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 5 HP/ 3.7kW motor, 10A TP, 6.3-10A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (2.5 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx2.5 sq.mm, Al, XLP Arm. Cables (For 5.0 Hp Motor)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal on 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 1.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Lighting, and 1.0 HP Motor)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
MGH Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
5HP / 3.7kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 5 HP/ 3.7kW motor, 10A TP, 6.3-10A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (2.5 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx2.5 sq.mm, Al, XLP Arm. Cables (For 5.0 Hp Motor)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 1.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Lighting, and 1.0 HP Motor)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
U' Block Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
2HP / 1.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 2 HP/ 1.5kW motor, 4A TP, 2.5-4A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (1 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx2.5 sq.mm, Al, XLP Arm. Cables (For 5.0 Hp Motor)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 2.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Lighting, and 2.0 HP Motor)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
S' Block Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
2HP / 1.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 2 HP/ 1.5kW motor, 4A TP, 2.5-4A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (1 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx2.5 sq.mm, Al, XLP Arm. Cables (For 5.0 Hp Motor)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 2.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Lighting, and 2.0 HP Motor)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
CD Mess Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
5HP / 3.7kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 5 HP/ 3.7kW motor, 10A TP, 6.3-10A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (2 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx2.5 sq.mm, Al, XLP Arm. Cables (For 5.0 Hp Motor)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 5.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Lighting, and 5.0 HP Motor)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
A' Type Pump House 500 Room Ladies Hostel MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
10.0 HP Starter Panels (Submersible) Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 10 HP/7.5kW motor, 16A TP, 11-16A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 10 HP / 7.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (4 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
LV Cables Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 3Cx6 sq.mm, (For 10 HP Motors)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 2Cx2.5 sq.mm, Al, XLPE Arm. Cables (for 1-Ph Loads, PLC, UPS)
Aluminium conductor Three core, XLPE / PVC insulated & armoured cable 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 5.0 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCB DB & 10 HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
500 Room Ladies Hostel MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 400 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
7.5HP / 5.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 7.5 HP/5.5kW motor, 13A TP, 9-13A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 7.5 HP / 5.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (4 kVAR) -
3.0HP / 2.2kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 3.0 HP/2.2kW motor, 6.3A TP, 4-6.3A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceablefixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (2 kVAR) -
1.5HP / 0.75kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 1.5 HP/0.75kW motor, 2.5A TP, 1.6-2.5A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceablefixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (1 kVAR) -
7.5HP / 5.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 7.5 HP/5.5kW motor, 13A TP, 9-13A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 7.5 HP / 5.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (2.5 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
1.1kV Cables Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx6 sq.mm, (For 7.5 HP Motors)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx2.5 sq.mm, (For 3 Hp & 1.5 HP Motor)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 2Cx2.5 sq.mm, (for 1-Ph Loads, PLC, UPS)
6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCC & upto 10HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc. 12 SWG (Lighting and Receptacles & Motors of 5 HP and below)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
Biological Sciences Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 125 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
7.5HP / 5.5kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 10 HP/7.5kW motor, 13A TP, 9-13A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 7.5 HP / 5.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (2.5 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
1.1kV Cables Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx6 sq.mm, (For 7.5 HP Motors)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 2Cx2.5 sq.mm, (for 1-Ph Loads, PLC, UPS)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 7.5 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCC & 7.5HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc. 12 SWG (Lighting and Receptacles & Motorised Valves)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
Old Aerospace Pump House MCC Panel Incomer Side: Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 200 Amps 35kA, FOUR POLE
Supplying and fixing of Shunt trip suitable for MCCB CBCT.
Supplying, fixing and wiring Earth Leakage Relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy
20HP / 15kW Motor Outgoing Feeder Motor Protection Circuit Breaker (Overload + Short circuit protection) suitable for 10 HP/7.5kW motor, 32A TP, 24-32A overload relay, with Conforming IS/IEC 60947-1, IS/IEC 60947-2, IS/IEC 60947-4-1.
Supplying fully Automatic Star-Delta 10 HP / 7.5kW starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor (6 kVAR) -
Other Outgoing Feeder Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32A TPN MCB
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16A DP MCB (for lighting, PLC, UPS, 1-Ph circuits)
Supplying and fixing Miniature Circuit Breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 32 A 3P+E-FP Industrial Plug & Socket, suitable for flush mounting
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
1.1kV Cables Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 3Cx6 sq.mm, (For 20 HP Motors)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 2Cx2.5 sq.mm, (for 1-Ph Loads, PLC, UPS)
Supplying & fixing of PVC/XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For 20 HP Motors)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (for 1-Ph Loads, PLC, UPS)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 1.5 sq mm Copper lugs (for PLC operation)
Earthing Supplying and running of GI strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI (MCC & 20HP Motor)
Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc. 12 SWG (Lighting and Receptacles & Motorised Valves)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Lighting Supply, installation, testing & commissioning of Light Luminares complete with: a) All accessories including mounting for fully functioning of fixture (Indoor & Outdoor). b) Earthing of fittings. c) Lamp of suitable wattage. Lighting Luminaries Indoor Lighting: 18W/20W, 1700 lumens, T5, 120.360mm length LED with extruded polycorbonate / white powder coated slim box made of CRCA sheet tube light fixture, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (Part 5/ Sec 1)..2012 a) Makes: Phillips / GE / Crompton / Wipro / Bajaj / Havells / VIN / Renesola b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
LED Driver as per IS 15885 (Part 2 / Sec 13)..2012 with input line voltage 120.36V-270V AC, 50Hz with surge protection more than 2.5 KV, IP20, suitable for 12 / 18 W LED down lighter with 2 Years Warranty.
LED Street Light - 70W
Fixing of Fittings Fixing all types & all capacities fluorescent/ CFL fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76 " twin twisted PVC insulated wires.
Supplying and Fixing of 32mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall usingsuitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Point wiring (for Normal lighting system controlled directly by MCBs from LDB) Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for light point & ceiling fan circuits, LDB to modular switch box with a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 4-5 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc. c) Superior quality 4 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 6A one way switch on existing modular switch plate. e) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 1.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) i) Wiring upto 5M primary length.
Primary Point wiring for sockets a) Heavy gauge PVC Open conduit pipe 40mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws b) Surface / flush mounting 6-8 way unbreakable PVC modular box suitable for mounting modular switch plates.The box should be firmly/surface/flush mounted after due groove cutting in brick / cc wall, fixing including necessary rawl plugs, Machine/NF screws etc c) Superior quality 8 module modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwws, bolts nuts etc., complete on the existing metal / PVC box. d) Modular 16A one way switch & 6/16A universal socket on existing modular switch plateon e) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) f) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) ii) Wiring upto 10M primary length.
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Short point (not exceeding 3m)
Secondary Light point (from above primary light point to subsequent points controlled on same circuit. Wiring from 1st light point to next light points) a) Heavy gauge PVC Open conduit pipe 32mm dia and 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using WF screws. b) Wiring for lighting/power circuit using 4 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For Phase & Neutral) c) Wiring for lighting/power circuit using 2.5 sq.mm PVC insulated 1100V grade, copper conductor single core cable in open system of wiring. (For earthing) Medium point above 3m and up to 6m
Miscellaneous Supply of suitable Nylon Cable Ties
Supplying Electrical rubber mat tested to 22kV, with grooved ISI mark, 1.82 x 0.91 x 0.021m
Supplying rubber gloves of 15KV conforming to IS
Supplying fire extinguisher with connected accessories complete, water CO2 type 4.5 litres
Supplying and fixing of danger board made out of MS sheet metal with two coats of non corrosive enameled paint
Other Micellaneous Items 1.1kV Cables Supplying & fixing of Cables 3Cx4 sq.mm, Al, XLP Arm. Cables (For Motorised Valves)
Supplying & fixing of Cables 6Cx1.5 sq.mm, Cu Control Cable (for PLC operation)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm (upto 3Cx16 sq.mm & 4Cx10 sq.mm)
Supplying and erecting crimpling type aluminium lugs conforming to IS suitable for cable as below evenly crimped with high pressure tool and connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner. upto 16 sq mm (For Motorised Valves)
Earthing Supplying and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas.spacers etc. 12 SWG (Mot. Valves)
Supplying fixing and wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40 mm dia 2.9 thick GI pipe 2.5 meter long buried in a pit. The pit should be filled with equal proportion of salt charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12.2mm dia
Miscellaneous Supply of suitable Nylon Cable Ties. Supply of Saddle / Clamps suitable for fixing 3 Core 4 Sqmm Cable.
MECHANICAL ITEMS WORKS Spare Pumps R-block Providing, erecting and giving test of Centrifugal Monoblock pump set conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. 5.0 HP at R-block
C-mess Providing, erecting and giving test of Centrifugal Monoblock pump set conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. 7.5 HP at C-mess
HE pump house Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. Submersible monoblock Pump set (with Bronze / Stainless steel(CF8M) Impeller) Horizontal / Vertical - up to 3 stages (Motor with water lubricated bearing to accept entire hydraulic thrust) 10HP at HE Pump House
KV school PH Providing, erecting and giving test of Centrifugal Monoblock pump set conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. 7.5 HP at KV school PH
S-block Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. Submersible monoblock Pump set (with Bronze / Stainless steel(CF8M) Impeller) Horizontal / Vertical - up to 3 stages (Motor with water lubricated bearing to accept entire hydraulic thrust) 3 HP at S-block
E Block PH Providing, erecting and giving test of Centrifugal Monoblock pump set conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. 5.0 HP at E Block PH
DI Altitude Control and Flow Control Valve (PN10/16) DI Altitude Control and Flow Control Valve (PN10/16) with the function to ensure that water in tank does not exceed a certain level and the same time not allow flow rate to exceed set point. The Hydraulic Valve trim connection shall have two metal points, one for Altitude control and Flow-rate control function. The valve shall use an orifice plated on downstream side to limit the flow rate. The set level can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Altitude Control and Flow Control Valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 389.406-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 153.408, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of SS 304 for altitude pilot as per standard parts according to DIN EN 12 266-1, the stainless steel 316 of orifice plate and dimension of orifice as per the flow rate set point, all the external control tubing of SS 304 / copper / reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve / speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing. Note: Supply of valves includes 5 years warranty 50 mm
DI Altitude Control and Flow Control Valve (PN10/16) with the function to ensure that water in tank does not exceed a certain level and the same time not allow flow rate to exceed set point. The Hydraulic Valve trim connection shall have two metal points, one for Altitude control and Flow-rate control function. The valve shall use an orifice plated on downstream side to limit the flow rate. The set level can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Altitude Control and Flow Control Valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 389.406-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 153.408, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of SS 304 for altitude pilot as per standard parts according to DIN EN 12 266-1, the stainless steel 316 of orifice plate and dimension of orifice as per the flow rate set point, all the external control tubing of SS 304 / copper / reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve / speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing. Note: Supply of valves includes 5 years warranty 80 mm
DI Altitude Control and Flow Control Valve (PN10/16) with the function to ensure that water in tank does not exceed a certain level and the same time not allow flow rate to exceed set point. The Hydraulic Valve trim connection shall have two metal points, one for Altitude control and Flow-rate control function. The valve shall use an orifice plated on downstream side to limit the flow rate. The set level can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Altitude Control and Flow Control Valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 389.406-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 153.408, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of SS 304 for altitude pilot as per standard parts according to DIN EN 12 266-1, the stainless steel 316 of orifice plate and dimension of orifice as per the flow rate set point, all the external control tubing of SS 304 / copper / reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve / speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing. Note: Supply of valves includes 5 years warranty 100 mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 389.406-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 153.408, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing. Note: Supply of valves includes 5 years warranty 50 mm
INSTRUMENTATION AND CONTROL WORKS SCADA System for Water Supply distribution Network Supply, Installation, Testing and Commissioning of Programable Logic Control, 32 Bit, Non Redundant
Supply, Installation, Testing and Commissioning of Digital Input Module- 16 Channel
Supply, Installation, Testing and Commissioning of Digital Output Module- 16 Channel
Supply, Installation, Testing and Commissioning of Analogue Input Module- 8 Channel
Supply, Installation, Testing and Commissioning of RS 485 Module
Supply, Installation, Testing and Commissioning of Ethernet Switch, Minimum 8 port, Managed Network Switch
Supply, Installation, Testing and Commissioning of Fiber Optic Converter
Supply, Installation, Testing and Commissioning of 10" Color HMI
Supply, Installation, Testing and Commissioning of UPS System, Minimum 1 KVA
Supply, Installation, Testing and Commissioning of PLC Panel that includes Fabrication, Internal wiring, MCB, Space Heater, Hooter, Accept/ Reset/ Emergency Push Button, Plug-Socket, Relay Card, Light with Door Switch, Cooling Fan, Terminal Block, Cable Channel and all required hardware to complete the PLC System
Service of Programming/ System Integration for PLC, HMI and SCADA System, System Integration for each pumping station along with Central SCADA System
Supply, Installation, Testing and Commissioning of Industrial Grade Workstation (Computer System), 8GB RAM, 1 TB Storage Size, Intel Core i5/ i7 (Workstation model), Screen Size 22"/ 21.5", Display Resolution- 1920 x 1080, ASCII keyboard and Optical Mouse (preferred Wireless), DVD R/W Drive along with Original OS Paper License or CD & antivirus Paper License or CD
Supply, Installation, Testing and Commissioning of UPS‐5 KVA with one hour backup along with SMF batteries and connection cables, 230 V AC O/P and any other items required to complete the system
Supply, Installation, Testing and Commissioning of 2 Ton Air Conditioner with copper tube and Inverter based design with 5 year warranty
Supply, Installation, Testing and Commissioning of A4/ A3 colour laser network printer
Supply, Installation, Testing and Commissioning of Computer console suitable for mounting Computer System and printer
Supply, Installation, Testing and Commissioning of Revolving chairs
Supply, Installation, Testing and Commissioning of PLC Programming Software (license with lifetime validity)
Supply, Installation, Testing and Commissioning of SCADA Run Time Software (license with lifetime validity)
Supply, Installation, Testing and Commissioning of SCADA Development Software (license with lifetime validity)
Supply, Installation, Testing and Commissioning of Ethernet Switch, Minimum 16 port Managed Network Switch, WAN Router with VPN support and Firewall, Cabinet to complete all network solution for data communication
Supply, Installation, Testing and Commissioning of LED/ LCD Dash Board (SMART TV-55") along with necessary controller, hardware and accessories & mounting of Equipment, with communication cable to display entire network of pumping station, trends, reports, alarms etc.
Supply, Installation, Testing and Commissioning of Ethernet Cables CAT 6 ( For PLC to HMI and Ethernet Switch to computer, Ethernet Switch to PLC Communication)
Supply, Installation, Testing and Commissioning of FO Cables (For FO Converter to FO Converter Communication)
Supply, Installation, Testing and Commissioning of 3C X 1.5 sq. mm Armoured Copper Cables for Powering the PLC Panel (per metre)
Supply, Installation, Testing and Commissioning of 1P X 1 sq. mm Armoured Copper Cables for Communicating signal from Instruments to PLC panel (per metre)
Supply, Installation, Testing and Commissioning of 5P X 1 sq. mm Armoured Copper Cables for Communicating signal from MCC Feeder to PLC panel (per metre)
Supply, Installation, Testing and Commissioning of Instrument Cable tray- 100 X 50 mm along with cover, fastner, nut -bolts etc to complete the Cable tray work
Supply, Installation, Testing and Commissioning of Instrument Earthing System- Copper Earthing Electrode along with Earthing Copper Cable (Green/ Yellow)- 4 Sq.mm
Field Instrumentation OLD AEROSPACE PUMP HOUSE Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 4.5 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary Size: 150 mm dia
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 200 mm dia
U BLOCK PUMP HOUSE Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, s tub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of magnetic type Level Switch for the Overhead Tank, High Level & Low Level sensing - (2 point contact)with necessary instrumentation cabling,glands with suitable stub, flange, bolting and canopy arrangement for hook-up, as applicable and necessary. ( 0 - 3 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 100 mm dia.
S BLOCK PUMP HOUSE Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of magnetic type Level Switch for the Overhead Tank, High Level & Low Level sensing - (2 point contact)with necessary instrumentation cabling,glands with suitable stub, flange, bolting and canopy arrangement for hook-up, as applicable and necessary. ( 0 - 3 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 50 mm dia.
HE PUMP HOUSE Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of magnetic type Level Switch for the Overhead Tank, High Level & Low Level sensing - (2 point contact)with necessary instrumentation cabling,glands with suitable stub, flange, bolting and canopy arrangement for hook-up, as applicable and necessary. ( 0 - 3 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 100 mm dia.
500 Room Ladies Hostel Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of magnetic type Level Switch for the Overhead Tank, High Level & Low Level sensing - (2 point contact)with necessary instrumentation cabling,glands with suitable stub, flange, bolting and canopy arrangement for hook-up, as applicable and necessary. ( 0 - 3 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 100 mm dia.
CHEMICAL SCIENCES Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr)
CVH Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr)
MGH Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr)
R' Block Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr) - For Ramanujam
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: . 25 mm dia. (flow Range 40 to 80 m3/hr) - For Kaveri
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr) - For 'M' Block
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr) - For 'N' Block
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr) - For 'R' Block
Bharani Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 25 mm dia. (flow Range 40 to 80 m3/hr) - For Bharani
Rohini Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: . 25 mm dia. (flow Range 40 to 80 m3/hr) - For Rohini
Phyical Sciences Supply, Installation, Testing and Commissioning of magnetic type Level Switch for the Overhead Tank, High Level & Low Level sensing - (2 point contact)with necessary instrumentation cabling,glands with suitable stub, flange, bolting and canopy arrangement for hook-up, as applicable and necessary. ( 0 - 3 m)
Bilogical Sciences Supply, delivery at site and fixing of magnetic type Level Switch for the Overhead Tank, High Level & Low Level sensing - (2 point contact)with necessary instrumentation cabling,glands with suitable stub and flange and bolting arrangement for hook-up, as applicable and necessary. ( 0 - 3 m)
AEROSPACE Supply, Installation, Testing and Commissioning of Ultrasonic type Level Indicating Transmitter with necessary instrumentation cabling, glands with suitable Canopy, stub, flange and bolting arrangement for hook-up as applicable and necessary. (0 - 3.5 m)
Supply, Installation, Testing and Commissioning of Electromagnetic Flow Indicating Transmitter (full bore type) with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, canopy, as applicable and necessary. Size: 100 mm dia
Electromagnetic Flow Indicating Transmitters Supply, installation, Testing and Commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within +/- 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 153.408. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, SS 316 Round Head Electrodes with connections and wiring harness capable of submerged or buried operation with IP68 Protection. Earthing shall be with grounding rings. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. Size: 25 mm dia.
Supply, installation, Testing and Commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within +/- 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 153.408. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, SS 316 Round Head Electrodes with connections and wiring harness capable of submerged or buried operation with IP68 Protection. Earthing shall be with grounding rings. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. Size: 50 mm dia.
Supply, installation, Testing and Commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within +/- 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 153.408. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, SS 316 Round Head Electrodes with connections and wiring harness capable of submerged or buried operation with IP68 Protection. Earthing shall be with grounding rings. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. Size: 80 mm dia.
Supply, installation, Testing and Commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within +/- 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 153.408. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, SS 316 Round Head Electrodes with connections and wiring harness capable of submerged or buried operation with IP68 Protection. Earthing shall be with grounding rings. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. Size: 100 mm dia.
Supply, installation, Testing and Commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within +/- 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 153.408. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, SS 316 Round Head Electrodes with connections and wiring harness capable of submerged or buried operation with IP68 Protection. Earthing shall be with grounding rings. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. Size: 150 mm dia.
Supply, installation, Testing and Commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within +/- 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 153.408. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, SS 316 Round Head Electrodes with connections and wiring harness capable of submerged or buried operation with IP68 Protection. Earthing shall be with grounding rings. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. Size: 200 mm dia.
Supply, Installation, Testing and Commissioning of Communication Cable between Flow Meter to PLC Panel, 1P X 1 sq. mm Armoured Copper Cables
Supply, Installation, Testing and Commissioning of Power Cable between PLC panel to Flow meter, 3C X 1.5 sq. mm Armoured Copper Cables for Powering the Flow Meter (per metre)
Supply & installation of MS Bolts and Nuts
Supply & installation of Rubber Insertion Sheet 3 Ply R.I. Sheet
Supply & fixing of MS flanges of required size for installation of flowmeters (upto 500mm dia pipes)
Smart Water Meter for Residential Purpose Supply, Installation, Testing and commissioning of water meter with pulser (1 LTR/ REED Pulse & 4 mtr Cable), Y Type Strainer, Data logger with converter module, Water meter prefabricated Box, Inlet and outlet pipe/ elbow, tee along with isolation valve. Dataloger input : Pulse output and Datalogger output: RS 485 modbus. Pulse ouput of water meter will connect to dataloger and dataloger output will connect to PLC Panel through RS 485 modbus output. Size: 25mm Dia
Supply, Installation, Testing and commissioning of water meter with pulser (1 LTR/ REED Pulse & 4 mtr Cable), Y Type Strainer, Data logger with converter module, Water meter prefabricated Box, Inlet and outlet pipe/ elbow, tee along with isolation valve. Dataloger input : Pulse output and Datalogger output: RS 485 modbus. Pulse ouput of water meter will connect to dataloger and dataloger output will connect to PLC Panel through RS 485 modbus output. Size: 40mm Dia
Supply, Installation, Testing and commissioning of water meter with pulser (1 LTR/ REED Pulse & 4 mtr Cable), Y Type Strainer, Data logger with converter module, Water meter prefabricated Box, Inlet and outlet pipe/ elbow, tee along with isolation valve. Dataloger input : Pulse output and Datalogger output: RS 485 modbus. Pulse ouput of water meter will connect to dataloger and dataloger output will connect to PLC Panel through RS 485 modbus output. Size: 50mm Dia
Supply, Installation, Testing and commissioning of water meter with pulser (1 LTR/ REED Pulse & 4 mtr Cable), Y Type Strainer, Data logger with converter module, Water meter prefabricated Box, Inlet and outlet pipe/ elbow, tee along with isolation valve. Dataloger input : Pulse output and Datalogger output: RS 485 modbus. Pulse ouput of water meter will connect to dataloger and dataloger output will connect to PLC Panel through RS 485 modbus output. Size: 80mm Dia
Supply, Installation, Testing and commissioning of water meter with pulser (1 LTR/ REED Pulse & 4 mtr Cable), Y Type Strainer, Data logger with converter module, Water meter prefabricated Box, Inlet and outlet pipe/ elbow, tee along with isolation valve. Dataloger input : Pulse output and Datalogger output: RS 485 modbus. Pulse ouput of water meter will connect to dataloger and dataloger output will connect to PLC Panel through RS 485 modbus output. Size: 100mm Dia
Communication Cable between Datalogger to PLC Panel, 1P X 1 sq. mm Armoured Copper Cables
Service of Water Meter Data Integration to PLC/ SCADA System and necessary support and service for Graphics designing/ Report Generation etc.
Canopy for Field Instruments Fabricating supplying and mounting MS box made out 14 SWG CRCA sheet, suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be paint with anticorrosive color processed with 7 tanks powder coating treatment and finally finished with approved colour etc., complete. Size: 30cmx50cm
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron 50x50x6mm and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
R K ENGINEERS SALES LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
PhaseIIdrawings.pdf
Additional Documents • 27.45 MB
BOQ_737102.xls
BOQ • 1.18 MB
FinalphaseIITD.pdf
Tender Documents • 1.56 MB
Download all tender documents and submit your bid