Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 309 SKYLARK BUILDING 309 SKYLARK BUILDING 60 NEHRU PLACE NEW DELHI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Finance |
| 3 | Admitted-Finance PUNE | PUNE | MAHARASHTRA | 410301 | Admitted-Finance |
Tender Value
₹94.5 L
EMD Value
₹1.9 L
Closing Date
17 Jul 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR IISER PUNE
IISER Pune Dr homi Bhabha road pune 411008
Augmentation of the Electrical distribution and UPS power for first floor HPC room, Main building IISER Pune
2023_IISRP_759455_1
13/ IISER/PUNE/2023 24
Open Tender
Electrical Works
Works
120 days
IISER PUNE
As per NIT
3 documents required · 3 mandatory
₹1,180
DIRECTOR IISER PUNE
₹1.9 L
9 Oct 2023
27 Jun 2023
18 Jul 2023
27 Jun 2023
17 Jul 2023
27 Jun 2023
Amount
Please note that Quoted rates are inclusive of taxes,labor,transportation, royaltie etc. Nothing Extra shall be paid separtely.
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 3.5 Core x 300 Sqmm Armoured Aluminium (A2XFY) Cable. (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having Copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 4c x 16 sqmm armoured copper cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having Copper conductor XLPE insulated sheathed,unarmoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 4c x 16 sqmm flexiable copper cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 3.5 Core x 150 Sqmm Armoured Aluminium (A2XFY) Cable. (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 4c x 25 sqmm armounred copper cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having copper conductor XLPE insulated sheathed,un armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 6 c x 6 sqmm copper flex cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having copper conductor XLPE insulated sheathed, un armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 1 x 70 sqmm copper flex cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having copper conductor XLPE insulated sheathed, un armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 1 x 95 sqmm copper flex cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having copper conductor XLPE insulated sheathed, un armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 1 x 120 sqmm copper flex cable (Approved make : Polycab /Finolex / RR Kabel )
Supplying LT cable having copper conductor XLPE insulated sheathed, un armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part−II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer−in charge. Supply of cable 1 x 6 sqmm copper flex cable (Approved make : Polycab /Finolex / RR Kabel )
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. ( Above 185 sq. mm and upto 400 sq. mm )
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. ( Above 185 sq. mm and upto 400 sq. mm )
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. ( Above 185 sq. mm and upto 400 sq. mm )
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. ( Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. ( Upto 35 sq. mm (clamped with 1mm thick saddle) )
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. ( Upto 35 sq. mm (clamped with 1mm thick saddle) )(Approved make : Polycab /Finolex / RR Kabel / Havells / KEI )
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. ( Above 95 sq. mm and upto 185 sq. mm )
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray / into existing pipe / on surface / open ducts as required. ( 6 sqmm flexible cable ) .
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray / into existing pipe / on surface / open ducts as required. ( 70 sqmm flexible cable ) .
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray / into existing pipe / on surface / open ducts as required. ( 95/120 sqmm flexible cable ) .
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 3/4 X 300 sq. mm (70mm) ) ( Approved make : Dowells / CI / Electrowerke )
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 4 X 16 sq. mm (28 mm) ) ( Approved make : Dowells / CI / Electrowerke )
Supplying and making end termination with PVC gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 4 X 16 sq. mm copper flex cable (28 mm) )( Approved make : Dowells / CI / Electrowerke )
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 3/4 X 150 sq. mm (50mm) ) ( Approved make : Dowells / CI / Electrowerke )
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 4 X 25 sq. mm (28 mm) ) ( Approved make : Dowells / CI / Electrowerke )
Supplying and making end termination with PVC gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 4 X 6 sq. mm copper flex cable (20 mm) ) ( Approved make : Dowells / CI / Electrowerke )
Supplying and making end termination with PVC gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 70 sq. mm copper flex cable (28 mm) ) ( Approved make : Dowells / SMI / CI / Electrowerke )
Supplying and making end termination with PVC gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 95/120 sq. mm copper flex cable (35 mm) )( Approved make : Dowells / CI / Electrowerke )
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) Suitable for MCCB incomer . ( 4 way (4 + 12), Double door ) ( Approved make : MK / Legrand / Schneider )
Supply and installation of MCCB enclosuser box with 250 A 4 pole 36 kA MCCB having required accessories, mouting , handle etc as complete, enclosuer should be suitable for termination of 3.5 c x 300 sqmm cable at both end of MCCB. Duly painted and having wall mounting arrangment . cable entery top and bottom, as complete.
Supplying and fixing 63 A, 415 V, TPN In dustrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 63 A "C"curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. ( Approved make : MK / Legrand / Schneider )
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required. ( Triple Pole ) ( Approved make : MK / Legrand / Schneider )
Supply, installation, testing and commissioning of 125 A, MCCB , 4 pole, 36kA , Microprocessor based into existing DBs as complete with all accessories. ( Approved make : MK / Legrand Schneider )
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, IP rating IP 66 / 67 ,5 pin with 4 pole and earth, metal enclosed plug top alongwith 32 A "C"curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. ( Approved make : MK / Legrand / Schneider )
Supplying and fixing 32 A, 230 V, SPN In dustrial type socket outlet,with 2 pole and earth, metal enclosed plug top alongwith 32 A "C"curve, DPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. ( Approved make : MK / Legrand / Schneider )
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required. ( FP MCB 63 A ) ( Approved make : MK / Legrand / Schneider )
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. ( 150 mm width X 50 mm depth X 1.6 mm thickness ) ( approved make : Storrax / Skaber / Profab )
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as reauired. ( 150 mm width X 50 mm depth X 1.6 mm thickness ) ( Approved make : Storrax / Skaber / Profab )
Supply, installation, testing and commissioning of Chemical earthing using electrode of size 76 mm minimum diameter, minimum 03 meter long and connected with 50x5 mm copper internal strip, material of conustruction COPPER, complete with existing excavation / bore, civil work for chamber, cast iron cover size 450 x 450 mm, with backfill compound as requred to fill earth pit up to mark. the earth resistance shall be as per IS 3043 ( Approved make : Yash Earthing / true power / fast electrode / Maxwell Earthing )
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre lonq etc. with charcoal/ coke and salt as required.
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre lonq etc. with charcoal/ coke and salt as required.
Supplying and laying 12 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
Supply, installation, testing and commissoning of UPS & Battery rack 100KVA rating UPS with ,15Min battery backup , with static & manual bypass Input Voltage: 3 Ph 415 Volts, ±10% Output : 3 -Phase-415Volts 4w 50 Hz ±1% , .( Note :- 100KVA UPS Dimesions 900X 900x2000mm Rack Size :- 1100x1000x2000mm UPS Make :- As per approved make list attached). Scope of work includes Supply, installation, testing , commissioning, shifting, transport, labour and final testing of UPS with its all accessories including isolation transformer, power links, cables, switchgears with enclosuer etc as complete to make it functional. Installation should be done by Engineer of authorised service dealer or manufacture of said UPS. Related information should be submiited to IISER Pune in advance for approval. Any charges payable to the UPS agency will be borne by the contractor. Detailed specifications of UPS is attached with tender document. Please refer Volume II . Page no. 87 for Scope of work and technical specifications. ( Approved make : a) Novature / Eaton / Vertive ) UPS
Supply of Surface Mounted 2'X2' , 36 / 40 W LED Luminaire Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire.Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 - 13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. ( Approved Make : Wipro / Crompton / Philips )
Supply of Recessed Mounted 2'X2' , 36 / 40 W LED Luminaire Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire.Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 - 13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. ( Approved Make : Wipro / Crompton / Philips )
ERECTION for Recessed/Surface Mounted 2'X2' , 36 / 40 W LED Luminaire incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( Approved make : MK Honeywell / Legrand )
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. ( 1 run of cable ) ( Approved Make : D-Link / Legrand / Polycab )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm ( Approved Make : Precision / DIAMOND / polycab )
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At field side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In −charge. Nothing extra shall be paid separately. ( Approved Make : D-Link / Legrand / Polycab )
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At Rackside side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In −charge. Nothing extra shall be paid separately. ( Approved Make : D-Link / Legrand / Polycab )
Excavation of the cable trenches in PCC, RCC with breaking of wall etc , including getting out the excavated soil and disposal of excavated soil / debries etc as directed within a lead of 50 metres.
HPC UPS incoming RAW PANEL : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO−9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) : HPC UPS incoming RAW PANEL : ( Approved make : CPRI Approved ) (LT panel accessories deatils enclosed asper annexure 1 volume II Page no 85) 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto−manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947−2IEC 947−26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. : HPC UPS incoming RAW PANEL : ( Approved make : CPRI Approved ) (LT panel accessories deatils enclosed asper annexure 1 volume II Page no 85)
AC PANEL : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO−9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) :1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto−manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947−2IEC 947−26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 300 sqmm alrmould cable for each feeder. : AC PANEL : ( Approved make : CPRI Approved ) (LT panel accessories deatils enclosed asper annexure 1 volume II Page no 85
UPS OUTGOING PANEL : Supply, installation, testing and commissioning of LT panel as per following specifications. Drawing, SLD, GA, BOM & specifications should be submitted to IISER Pune for approval before manufactureing of panel.Supply, installation, testing and commissioning of 3 phase, 4 wire, 415 KV, 0.8 PF, 50 HZ panels. The fabrication shall be made with 14 SWG cold rolled sheet with M/C pressing, powder coated. The surface shall be rigorously treated for derusting in 7 tank process with dephosphating & paintingwith at least 2 coats of approved paint. The panel shall be totally enclosed metal clad type with double gasketting with rubber/ resin lining. The panel shall be having control directory pasted inside the panel. The panel shall be mounted on existing trench/ floor & shall have cable entry provision from the top & bottom with suitable alley as the case may be. The panel shall be tested for the same KA rating of the relevant highhest rating of MCCB. All components shall be from ISO-9001 companies and shall have relevant IS/IES approvals without fail. The panel shall be fully interlocked as required. The panel shall include baseframe channel support. ( The single line daigram shall be closely followed) : 1. The panel shall be design as per norms of CEIG/ PWD/ CPWD/ Maharashtra State Electricity Distribution Company Ltd 2. Auxilliary contractor to be provided along with Auto-manual switch where ever required. 3. Ventilators shall be provided for Panels with rated bus bars.4. Al bus earthing shall be provided for all panels.5. Circuit Breakers shall confirm IS 13947-2IEC 947-26. All doors to have double rubber gasket with shutter assembly & door seating frame.7. The UPS outgoing panels shall have neutral busbars double the size of phase.8. All breaker to have breaker manufacturer's factory made Spreaders.9. In any case Aluminium busbar should not be connected directly to breaker without spreaders.10. The control wiring has to be in appropriate size with MCB protection. 11. Irrespective of the Amp. Capacity all breakers shall be connected to the breakers using busbar only.12. All vertical bus bars in bus bar alley shall have bottem supports.13. All panels shall have top entry only.14. Panel earthing strip should come out vertically on top the panel.15. Earthing bus shall be coated to give a look of tin.16. All indication should be proper colour and with protection of MCB.17. All meters should have protetion of MCB.18. Door earthings shall be provided for all doors.19. Suitable for termination of upto 3 1/2 C x 150 sqmm alrmould cable for each feeder. : UPS OUTGOING PANEL : ( Approved make : CPRI Approved )(LT panel accessories deatils enclosed asper annexure 1 volume II Page no 85)
Removing, shifting, transport, storage of existing Utility panel ( size : 2000 x 500 x 2400 mm ). Work includes required labour, hoist, tools and lifting equipments etc. Extrime care should be taken during handling of panel to avoide any accedent.
Removing & Refixing of existing Vertival type DB with its all accessories and MCBs / MCCBs on surface as required. Scope of work includes, shifting , removing, refixing with rewiring of Dbs with existing wires and cable, fixing of MCBs & MCCBs, makeing good as per site condition. Measurement will be done on actual reinstallation of Dbs. Removing, shifting, storage of DBs are in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unserviable. etc complete as per direction of Engineer In-charge. Nothing extra shall be paid separately.
Supply installation testing and commissioning of 2.0 TR/1.8 TR capacity Hiwall type indoor unit with ISEER value of min 4.6 or above with cordless remote control & outdoor unit with copper condenser coil mounted with suitable metal stand with R410 or equivalent green refrigerant gas only with inverter compresoor only, this item includes 3 meter copper pipe also. (Make : Toshiba /Mistubishi / Daikin)
Supplying & fixing of copper refrigerant piping of suitable size for 2.0 TR hiwall air condition units with minimum 9 mm insulation complete from indoor unit to outdoor unit with supports Etc.
Supplying and laying of 3 x 1.5 sq mm PVC insulated copper conductor flexible cable.
Supplying & fixing 25/32 mm size PVC drainage pipe with insulation i/c cutting the wall, finishing etc. as reqd.
Supply and installation of M.S. stand for 2.0 tr hiwall air condition outdoor units
BBP Electricals
Nikom Infrasolutions Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .