Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
12 Mar 2021, 1:00 pmClosed
HEAD ELECT AND MAINT
AERONAUTICAL DEVELPMENT AGENCY BANGLORE P.B NO. 1718, VIMANAPURA POST BANGLORE-560017
PROVISION OF UPS POWER, RAW POWER SUPPLY AND AIR CONDITIONING UNITS FOR PROPOSED RIG FACILITY FOR LCA AF MK1 A AT CANTEEN 2nd FLOOR BUILDING -ADA HQ
2021_DDRD_423401_1
0751/36/0900/ADA/ELECT/POWER
Open Tender
Electrical and Maintenance Works
Turn-key
90 days
ADA
Please refer tender documents
8 documents required · 8 mandatory
₹0
Exempted
15 Apr 2021
19 Feb 2021
13 Mar 2021
19 Feb 2021
12 Mar 2021
19 Feb 2021
19 Feb 2021 - 5 Mar 2021
Supply and laying of 4 core 95 sq mm PVC insulated Aluminium armoured, 1.1 KV grade underground cable in wall/trenches/above false ceiling/ducts by using GI clamps, fixing accessories etc. (Sl. No.1 of Annexure-1)
Providing cable end termination for the above 4 core 95 sq mm PVC U G cable using copper lugs, brass cable glands, etc as per standard practice. (Sl. No.2 of Annexure-1)
Supply, Install, Test and commissioning of LT panel board indoor type Fabricated Out of 2mm Thick CRCA sheet double door complete with powder coating with seven tank process mounted on M.S angle Iron frame, duly grouted with Anchor fasteners reqd. with following:- It should be accommodate 1 no. of 100 amps 4 pole MCCB for main incoming control and 3 Nos of MCB i.e 63A 4pole - 3 Nos. with proper copper bus-bar & neutral link/ cable link with lugs including the Volt meter, Ammeter, Indicators and termination etc., The Rate should be including Supply of 100 A MCCB – 1 no. & 63 A MCB - 3 Nos. fixing of panel board on floor by using anchor fasteners with labour charges complete in all respect. (Sl. No.3 of Annexure-1)
Supply and laying of 4 core 10 sq mm PVC insulated Copper armoured, 1.1 KV grade underground cable in wall/ trenches / above false ceiling/ducts by using GI clamps, fixing accessories etc. (Sl. No.4 of Annexure-1)
Providing cable end termination for the above 4 core 10 sq mm PVC U G cable using copper lugs, brass cable glands, etc as per standard practice. (Sl. No.5 of Annexure-1)
Supply, Erection, Testing & Commissioning of Distribution Board of MDS make comprising of :- 63 amps 3 phase 4 pole MCB, for main control – 1no. 32 amps 3 phase 4 pole MCB 2 - nos. 25 amps 3 phase 4 pole MCB 1 - no 10 amps 3 phase 4 pole MCB – 1 no. housed in suitable MCB Distribution board. (DB shall be Double Door System). The rate shall be taken including MCB cost. (For Radar system UPS Power) (Sl. No.6 of Annexure-1)
Supply and fixing on wall metallic standard DB of 3 phase - 4 pole MCB controlled by 5 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- a. 3 phase, 32 Amps 4pole MCB rating - 1 no. b. 3 phase, 25 Amps 4pole MCB rating - 1 no. c. 3 phase, 10 Amps 4pole MCB rating - 1 no. (5 pin industrial socket & top - Cutler hammer make). (For 3 phase, 50 Hz UPS power supply of Radar system). (Sl. No.7 of Annexure-1)
Supply and fixing on wall metallic standard DB of 3 phase - 4 pole MCB controlled by 5 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- a. 3 phase, 32 Amps 4pole MCB rating.. (5 pin industrial socket & top - Cutler hammer make). (For 110 Volts, 3 phase, 400 Hz power supply of Radar system) (Sl. No.8 of Annexure-1)
Supply, Erection, Testing & Commissioning of Distribution Board of MDS make comprising of 1 No. 63 amps 4 pole MCB, for main control & 4 Nos of 3 phase 4 pole MCB i.e. (20 amps) housed in suitable MCB Distribution board. (DB shall be Double Door System). The rate shall be taken including MCB cost. (For Radar system Raw Power) (Sl. No.9 of Annexure-1)
Supply and fixing on wall metallic standard DB of 3 phase - 4 pole MCB controlled by 5 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- 3 phase, 20 Amps 4pole MCB rating. (For Raw power supply RADAR SYSTEM) (Sl. No.10 of Annexure-1)
Supply, internal - wiring & installation of 03 Nos. of 6/16A power socket out let controlled by 10/20 amps single pole MCB housed in PVC boxes & 5A indicator switch, fixed at table top level as required by client. (8 module switch plate with box, white colour). UPS power supply should be tapped from 2 x 60 KVA UPS DB . (Sl. No.11 of Annexure-1)
Supply and fixing on wall metallic standard DB of 1 phase - 2 pole MCB controlled by 3 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- 1 phase, 20 Amps 2 pole MCB rating. (UPS power supply should be tapped from 2 x 60 KVA UPS DB) (Sl. No.12 of Annexure-1)
Supply, internal - wiring & installation of 01 No. of 16A power socket out let controlled by 16 amps single pole MCB housed in PVC boxes fixed at table top level as required by client. (3 module switch plate with box, white colour). UPS power supply should be tapped from 2 x 60 KVA UPS DB (Sl. No.13 of Annexure-1)
Supplying and drawing of sub mains circuit from main panel to distribution panel / boards located in individual UDB, using FRLS Multi-strand copper conductor of following specified sizes of 1100/660 V, FRLS insulated wires drawn in 2 mm thick 2” PVC conduits/casing n capping & its accessories. The rates shall include running of 660/250 V, grade FRLS insulted earth wire. a. 2 x 4 sq mm + 1 x 2.5 sq. mm FRLS wire in above false ceiling or wire race ways. Supply & Installation (Sl. No.14 of Annexure-1)
Supply and laying of 4 core 10 sq mm PVC insulated Copper armoured, 1.1 KV grade underground cable in wall/ trenches / above false ceiling/ducts by using GI clamps, fixing accessories etc.. (Sl. No.15 of Annexure-1)
Providing cable end termination for the above 4 core 10 sq mm PVC U G cable using copper lugs, brass cable glands, etc as per standard practice. (Sl. No.16 of Annexure-1)
Supply, Erection, Testing & Commissioning of Distribution Board of MDS make comprising of:- 3 phase 32 amps 4 pole - MCB, for main control – 1no. 1 phase 1 pole 10A MCB - 3 nos. 3 phase 4 pole 16 A MCB – 1 no. 3 phase 4 pole 25 amps – 1no. housed in suitable MCB Distribution board. (DB shall be Double Door System). The rate shall be taken including MCB cost.(For EW system DB - UPS Power) (Sl. No.17 of Annexure-1)
Supply, internal - wiring & installation of 03 Nos. of 6/16A power socket out let controlled by 10/20 amps single pole MCB housed in PVC boxes & 5A indicator switch, fixed at table top level as required by client. (8 module switch plate with box, white colour). (For EW system UPS power supply) . (Sl. No.18 of Annexure-1)
Supply and fixing on wall metallic standard DB of 3 phase - 4 pole MCB controlled by 5 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- a. 3 phase, 16 Amps 4pole MCB rating. (5 pin industrial socket & top - Cutler hammer make). (UPS power supply of for EW system). (Sl. No.19 of Annexure-1)
Supply and fixing on wall metallic standard DB of 3 phase - 4 pole MCB controlled by 5 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- a. 3 phase, 10 Amps 4pole MCB rating. (5 pin industrial socket & top - Cutler hammer make). For 110 Volts, 3 phase, 400 Hz power supply of RWR system. (Sl. No.20 of Annexure-1)
Supply, Erection, Testing & Commissioning of Distribution Board of MDS make comprising of 1 No. 63 amps 4 pole MCB, for main control & 3 Nos of 3 phase 4 pole MCB i.e. (20 amps) housed in suitable MCB Distribution board. (DB shall be Double Door System). The rate shall be taken including MCB cost. (For EW system DB - Raw Power). (Sl. No.21 of Annexure-1)
Supply and fixing on wall metallic standard DB of 3 phase - 4 pole MCB controlled by 5 pin industrial socket and plug top, with internal control wiring etc., complete in all respect as under :- a. 3 phase, 20 Amps 4pole MCB rating. (Raw Power) (5 pin industrial socket & top - Cutler hammer make). (For 3 phase, 50 Hz UPS / Raw power supply of Radar system). (Sl. No.22 of Annexure-1)
Supplying and drawing of sub mains circuit from main panel to distribution panel / boards located in individual UDB, using FRLS Multi-strand copper conductor of following specified sizes of 1100/660 V, FRLS insulated wires drawn in 2 mm thick 2” PVC conduits/casing n capping & its accessories. The rates shall include running of 660/250 V, grade FRLS insulted earth wire. a. 2 x 4 sq mm + 1 x 2.5 sq. mm FRLS wire in above false ceiling or wire race ways. Supply & Installation. (Sl. No.23 of Annexure-1)
Supplying and drawing of sub mains circuit from main panel to distribution panel / boards located in individual UDB, using FRLS Multi-strand copper conductor of following specified sizes of 1100/660 V, FRLS insulated wires drawn in 2 mm thick 2” PVC conduits/casing n capping & its accessories. The rates shall include running of 660/250 V, grade FRLS insulted earth wire. b. 4 x 4 sq mm + 1 x 2.5 sq. mm FRLS wire in above false ceiling or wire race ways. (R Y B N color coded wires is to be used). Supply & Installation. (Sl. No.23 of Annexure-1)
Supplying and drawing of sub mains circuit from main panel to distribution panel / boards located in individual UDB, using FRLS Multi-strand copper conductor of following specified sizes of 1100/660 V, FRLS insulated wires drawn in 2 mm thick 2” PVC conduits/casing n capping & its accessories. The rates shall include running of 660/250 V, grade FRLS insulted earth wire. c. 2 x 2.5 sq mm + 1 x 1.5 sq. mm FRLS wire in above false ceiling or wire race ways. Supply & Installation. (Sl. No.23 of Annexure-1)
Supply, erection, testing and commissioning of copper plate earth station conforming to IS 3043 complete with 600 x 600 x 3.15 mm thick copper plate, 40 mm dia. GI pipe of 2.5 mtrs length, watering funnel, charcoal, salt etc. including excavation, refilling and consolidating complete.) . (Sl. No.24 of Annexure-1)
Construction of masonry chamber for the earth pit including 2’ x 2’ cast iron top cover with frame embedded in the masonry work, marking on the chamber & painting etc, complete with neat cement finish. (Sl. No.25 of Annexure-1)
Supply and fixing on wall/wooden partition, 40 mm x 3.15 mm copper tape using suitable Bakelite bus-bar supports with brass bolt, nuts, screws with washers at every 2’ interval for fixing the copper earth strips. (Sl. No.26 of Annexure-1)
Supply & fixing of ¾” PVC pipe or ¾” casing and capping with all connecting accessories including of .51 mm Two pair twin core communication cable RJ 11 Roset – box,, with testing, termination etc. Make : Finolex, Anchor, Universal, CCI, L& T. (Sl. No.27 of Annexure-1)
Supply & fixing of 18 watts 1’ x 1’ size LED fitting including point wiring with necessary fixing accessories. (Sl. No.28 of Annexure-1)
Supply, Installation, Testing and Commissioning of 20 KVA / 20 KW, Input 3 phase 4 wire, Output 3 phase 4 wire, 415 volts, 50 Hz, Insulated Gate Bi-Polar Transistor based technology with 12 pulse characteristics (PWM technique) / IGBT Rectifier True Online (Pure Sine Wave) of 20 KVA / 20 KW with built in Isolation Transformer including Static and Manual by-pass mode with all productive safety devices etc., complete. Battery: S M F Battery Bank • Suitable capacity MCB with SC, OC and UV protection. • Supply of Battery bank in the scope of work. • Backup period – 30 minutes. The application of this UPS unit is for Frequency Converter load and able to withstand initial surge current. (Sl. No.29 of Annexure-1)
3 TR Slim line (vertex) Floor Mounting Type Split A/c unit: Supply of 3 TR floor mounting Slim Line (Vertex) type Split Air-conditioner unit including mounting frame for outdoor unit with Electrical control components complete with accessories like indoor unit, outdoor unit & codeless remote control with accessories etc., Detailed specification of 3 TR Slim line (vertex) Floor Mounting type Split A/c unit: Cooling capacity: 36000 (BTU/ HR) Compressor : Scroll Compressor unit, Refrigerant : Eco-friendly/ R-407C Blower motor : 3 phase, 430 volts, 50 Hz. Noise Level : 44 DB (A) Automatic Air Swing: Air Flow CFM – 1250, Timer / Quiet operation LCD display corded/ Remote control panel (Sl. No.1 of Annexure-2)
Supply & Laying of suction & Discharge pipe Size 5/8" soft drawn copper for suction & 3/8" soft drawn copper pipe for discharge to inter connect indoor & outdoor unit of 3 TR Slim line (Vertex) Air conditioners with necessary Vidoflex insulation. (Sl. No.2 of Annexure-2)
Installation Charges of the above Vertex A/c by inter connecting the suction & liquid pipe line, laying, Charges includes pressure testing, topping of gas, fixing the indoor unit, fixing the outdoor unit on the frame & Glass cutting work with necessary support & clamp & commissioning the units completed in all respect. (Sl. No.3 of Annexure-2)
Supply and Laying of 2.5 sq mm 5 core PVC Flexible copper cable through PVC pipe to individual A/C indoor unit to outdoor unit including necessary fixing accessories. (Sl. No.4 of Annexure-2)
Supply and fixing of 3Phase, 4pole, 32A Industrial Socket 1No. Control with 32A, 4Pole MCB, housed in metallic box with plug Top.. (Sl. No.5 of Annexure-2)
Supply and fixing of 4" PVC (BOX Type) casing & capping for routing copper piping and drain piping. (Sl. No.6 of Annexure-2)
Supply and laying of 4 core 2.5 Sq.mm PVC insulated armoured cable with copper conductor, laying on above false ceiling/ cable duct/ cavity flooring/ race way by using standard fixing accessories including cable termination by using brass gland, lugs etc., (Sl. No.7 of Annexure-2)
Re-installation of existing 2TR Air-conditioning unit of Outdoor unit & inter connecting the copper pipe line from outdoor unit to indoor unit with necessary Vidoflex insulation with required size 1” P.V.C pipe for drainage, 5 core control cable & power cable including gas charging, testing & commissioning complete in all respect. The rates should be including the following materials. • Copper pipe – 65 mtrs. • Control cable – 67 mtrs. • Drain pipe – 34 mtrs. • Power cable – 60 mtrs. . (Sl. No. 8 of Annexure-2)
M/s STAR ELECTRICALS
Lucky Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .