| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹37.7 L+₹4.7 L (14.3%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹40.3 L+₹7.3 L (22.2%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than Lowest |
Tender Value
₹47.8 L
EMD Value
₹95,680
Closing Date
8 Mar 2023, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
MISC WORKS OF AC PLANT AND OTHER INSTALLATION UNDER GE(U) PM DELHI CANTT-10
2023_MES_580286_1
GE(U)/PM/D-70/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DELHI CANTT
MES contractor enlisted under class D category a (i) b (i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹95,680
Yes
31 Mar 2023
10 Feb 2023
10 Mar 2023
10 Feb 2023
8 Mar 2023
22 Feb 2023
Amount
Section-I Dismantled of brick masonry work built in Cement mortar or cement lime mortar complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class except "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. (Note: old serviceable bricks obtained from item No 01 here-in- before shall be re-used)
Removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing of rubbish complete all as specified and directed.
Taking down cement or cement lime plaster , any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. (Note :- Complete removal surface to be verified by Engn-in-Charge before apply next treatment)
M&L for 12 MM thick plaster on brickwork or concrete surface of wall (Internal Surfaces) finished even smooth complete all as specified and directed by Engr-in-charge.
M&L for 15 MM thick plaster on brickwork or concrete surface of wall (External surfaces) using WPC finished even smooth complete all as specified and directed by Engr-in-charge(Note: WPC shall be paid seperately).
M&L for 5 MM thick plaster on ceiling surface finished even smooth complete all as specified and directed by Engr-in-charge.
M&L for Preparation of new plastered surface of walls & apply two coat of cement base paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings & apply three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & apply two coats of dry distemper, white or tinted over 1mm thick wall care putty complete all as specified and directed Make-Asian/Berger/Nicholson
Excavation in trenches in soft/loose soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation, etc, for pipes, walls, cesspits, manholes, pier holes, cables etc and getting out complete all as specified and directed.
Returning, filling in, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed
Removal of excavated soil to a distance exceeding 250m and not exceeding 500m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M&L for Cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified & directed.
M&L for Brick work with sub class’B’ well burnt bricks (best quality), having compressive strength of 100 kg/Sq cm straight or curved on plan exc 6m mean radius built in cement mortar 1:4 & pointed flush in the same mortar as the work proceeds incl demolition of old bricks, complete all as specified & directed.
Demolition of cement concrete in ground floor and paving n.exc 15CM thickness (below or above ground level) complete all as specified & directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site etc complete all as specified & directed.
M&L for Brick work with sub class’B’ bricks having compressive strength of 100 kg/Sq cm straight or curved on plan to any radious in half brick thick walls built in cm 1:4 and pointed flush in same mortar incl demolition of old bricks complete all as specified & directed.
S&F Red sand stone jali 40mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. including dismantling of old Jali and removing atleast 1.5 KM away from MoD land complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) in benching, coping etc including weathering slightly rounded or chamfered angles including necessary form work, complete all as specified and directed.
Supply only integral water proofing compound. (Make - Pidilite / Super Aquacem / Fosroc / Dr. Fixit)
S&F factory made SFRC (Steel fibre reinforcement concrete ) manhole cover medium duty M-25 grade,75mm thick with SFRC frame of clear size exc. 0.35 Sqm but n.exc 0.90 Sqm, provided with provision of two lifting hooks welded at appropriate location, complete all as specified & directed.
Cutting in existing manholes (150mm to 300mm dia) for connecting new drains ,making good to pipe and rendering cutting out existing benching for and forming branch channel,and reforming benchingas required.
M&L for 200mm nominal size Double wall corrugated HDPE pipes stiffness class SN 8 high density,polyethylene pipe resistent to chemicals,easy and light weighted,long living,low friction,flexible,sun resistant pipe and laid in trenches incl demolition of old pipes complete all as specified and directed. Make :- Finolex / Supreme / Astral / Prince.
Dismantling floor, hearth or wall including cement mortar bedding (but not backing), removing servicable complete all as specified and directed.
M&L for vitrified ceramic light shade tiles 10mm thick (Square) polished, area of each tile n exc 0.36 Sqm (size 600x600mm), in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. Make :- Johnson / Marbonite / Kajaria / Somany / Bell Granite.
M & L Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match laid over 20mm thick avg screed bed in CM 1:6 over 25 mm thick PCC 1:2:4 (use 12.5mm graded Aggregate) complete all as specified and directed. Make :- Johnson / Kajaria / Somany
M & L Coloured/printed Glazed ceramic tiles 350 x 250 x 7mm / 450 x 350x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match. Over 10 mm thick screed in CM 1:3 complete all as specified and directed. Make :- Johnson / Kajaria / Somany
M & L Glass Mosaic tiles 3mm thick , laminated plain coloured, marbled mosaic or mottled finish of size not less than 20mm X 20mm, laid with approved rubber based adhesive in vertical surfaces etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match laid over 10mm thick avg screed bed in CM 1:3 complete all as specified and directed. Make :- M/s Nitco / Duracrete / Mayur
S&F CPVC pipe 20mm external dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including dismantling old GI pipes complete all as specified and directed. Make :- Finolex / Supreme / Ashirvad.
S&F in repairs vitreous China Squatting pan 'Orrisa' pattern size 580x440mm white with integral foot rest, incl. CI floor trap( long nose) 'P' or 'S' trap, 100mm bore complete all as specified. ( Make :-Cera/Prayag/Parryware). Make :- Cera / Hindware / Parryware (1st Quality)
S&F in repair vitretious china wash down water closet pan (padestal pattern (excluding flushing cistern but including flush pipe and pvc sheet cover white). (Make :- Cera / Hindware / Parryware (1st Quality).
Supply and fixed in repair 10 Ltrs capacity PVC valveless symphonic action type flushing cistern white low level with inlet, ball valve float handle including bracket and Supply only Flush pipe of polyethylene of low or high density or PVC,32mm bore as per existing for low level cistern complete all as specified and directed.(Make: Cera/Hindware/Parryware)
Supply and fix in repair rotational moulded polythene, two layers, water storage tank 500 Ltrs capacity, closed top, cylindrical, hoisted and fixed in position including , 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight 20mm-210 gms.). Make :- Sintex / Polycon / Rotex, Make for ball valve :- Leader / Prayag / Parryware.
Supply and fixing in repair PVC connection 15mm size with PTMT nuts of length 600mm.
S & F in repair 15mm bore Stop valves, cast copper alloy, screwed down ,high pressure, with crutch or butterfly handles,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make :- Jaypee / Zoloto / Prayag Polymer.
S&F in repair 15 mm bib taps, cast copper alloy with chromium plated, crutch or butterfly handle screwed down, screwed for iron pipe and fixed complete. Make :- Jaquar / Kohlar / Marc / ESS ESS
S & F in repair 15mm bore angle stop valve ,cast copper alloy with chromium plated, , high pressure screwed for iron pipe or for unions and fixed. Make :- Jaquar / Kohlar / Marc / ESS ESS
Taking down PVC pipe of any size of any description with fittings complete all as specifed and directed. (Note:Prior approval to be obtain from Engineer-in-Chrage for taking down pipes)
S&F for 110mm bore PVC (SWR) 2pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete all as specified and directed by Engineer-in-charge. (Make: Finolex/Astral/Supreme/Ashirwad)
All as per ser item No 41 above but laid in trench or in floor. (Make: Finolex/Astral/Supreme / Ashirwad)
S&F for 110mm bore PVC (SWR) Gully Trap setting / jointed with solvent cement complete all as specified and directed. (Make :- Finolex / Supreme / Ashirvad).
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed. (Make :- Finolex / Supreme / Ashirvad).
S&F in repair for 75mm bore PVC pipes single socketed with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete all as specified and directed.(Make: Finolex/Astral)
All as per ser item No 45 above but laid in trench or in floor. (Make: Finolex/Astral/Supreme)
S&F in repair for 75mm bore PVC bends/junction any radius complete all as specified and directed.(Make: Finolex/Astral/SKF) .
S&F in repair PVC (SWR) floor trap,plain with grating 75mm bore including jointing in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
Material and labour framed work as in door or gates of angle or other section complete drilled for fixing sheeting with all fitting and fixture complete all as specified and directed.(Fe-410-W(Gde-E-250 quality-A) (used for window also)
Taking down door/window/ventilator frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) all as specified.
Taking down door/window frames with shutters exc 1.50 sqm but not exc 4.00 sqm each (without taking off shutters from frame) all as specified.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each.
S&F steel window with side hung shutter including box type hinges with steel handle and steel peg stay complete with glazing bar and including 12mm dia square bar for guard bars @ 125c/c horizontally complete all as specified and directed.
All as per item No. 54 above but without glazing bars and grill.
S&F powder coated(minimum thickness of powder coating 50 micron) aluminium for three track window and aluminium section weighing more than 0.4kg/Rm of sliding members incl all necessary fittings and fixtures, jointing cleats, rubber packing etc complete all as specified and directed. (Make of Alumimium Section : Hindalco / Indal / Jindal)
S&F powder coated aluminium frame for windows, ventilators and sliding tracks, beading for grill with one or more rebates including joining cleat for fixing etc. complete all as specified and directed (min thickness of powder coating 50 micron). (Make of Alumimium Section : Hindalco / Indal / Jindal)
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. (Make of Alumimium Section : Hindalco / Indal / Jindal)
S&F solid PVC door frame of size 50 x 47mm made out of 5mm wood grain printed PVC sheet re-inforced with MS square tube, supplying and fixing in opening as per manufacturers instructions drawings and specifications complete all as specified and directed. (Make :- M/s Rajshri Plastiwood Ltd,M/s Sintex Industries Ltd. and M/s Dura Plast extrusion)
M&L for framed work as in door/vent/CB chowkats of angle or other section, frame work for chajja with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering and including cutting brick for hold fast. confirming to Fe 410-W (Gde-E-250) quality 'A' including necessary welding complete all as specified and directed.
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded pre-laminated PVC sheet having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined suitable PVC sheet beading and joined together with solvent cement and provision of partially louvered frame supply and fixing in the frame at site. Complete all as per specification & sample kept in GE office and as directed. (Make :- M/s Rajshri Plastiwood Ltd,M/s Sintex Industries Ltd. and M/s Dura Plast extrusion)
S&F Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated as directed by Engineer-in-Charge.
S&F gauged skelton door shutter IInd class hard wood 35 mm thick rebated and prepared to received glass, gauge etc (without sash bars) edges of forming plain,chamfered or rounded fitted with mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I section 8,clause 8.24(a) etc.complete all as specified and directed.
S&F 35mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 18mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides as shutter of cupboard complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples/stainless steel wire stapple with screws complete all as specified and directed.
M&L painting two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces exc 10mm girth including preparation of new surfaces complete all as specified and directed. (Make :- Asian Paints / Nerolac Paints / Berger Paint / Jenson & nicholson Paints)
M&L painting two coats of synthetic enamel paints over a coat of pink primer on wooden surfaces of girth exc 10CM, including preparation of surfaces. complete all as specified and directed. (Make :- Asian Paints / Nerolac Paints / Berger Paint / Jenson & nicholson Paints)
S&F 100 mm long stainless steel butt hinges medium weight fixing with stainless steel screw complete all as specified and directed.
S&F 75mm long butt hinges medium weight cold rolled MS to pressed steel/angle iron frames complete all as specified and directed.
S&F 150mm long aluminum anodized barrel tower bolt of extruded section complete all as specified and directed.(Make :- Jindal / Crown / Classic).
S&F 125mm long aluminium handles cast type anodised ISI Marked (Make :- Jindal / Crown / Classic).
S&F 250mm long MS sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F hasp and staple size 75mm safety type, aluminium anodised, including bolt to hinge plate and fixed with screws all as specified.
M&L for Steel work in tubular trusses/ parapet railing including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. Complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour as approved by GE having tensile strength of 550Mpa as in roof covering, ridge, fixed with self tapping screws complete all as specified & directed. (Make :- Tata / JSW / Essar).
S&F pre-painted galvatume aluminium zinc coated GI based plain steel sheet or machine moulded profile ridge/corrugated steel sheet ridge 0.50 mm thick of any colour as approved by GE having tensile strength of 550Mpa as in roof covering, ridge, fixed with self tapping screws complete all as specified & directed. (Make :- Tata / JSW / Essar).
M&L for machine pressed chequered cement concrete glossy tiles 25 mm thick set jointed and pointed in neat cement slurry in floors with gray cement and pigment including 15 mm thick screed bedding layer in cm 1:6 including demolition of old tiles and removing debrish beyond MOD land complete all as specified and directed. (Make :- M/s Ultra tile/Nitcol Pavit / Mehitab tiles).
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames, glazed with oil putty or fixed with beads. Complete all as specified and directed.
S&F Sheet glass, 3mm thick ordinary quality, and glazing with oil putty in squares, not exceeding 0.50 sqm in each pane complete all as specified and directed. (Make :- Saint Gobin / Modi guard / Atul glass Industries).
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified & directed
Demolition of mud phuska on roof slabs, any thickness incl cleaning of roof surfaces and removing the debris upto the distance exc. 1.00 Km but n. etc1.5 Km complete all as specified and diected
Scrapping of old tar fell roof treatment over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface ( buy mechanical means like grinder etc ) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (Using 20mm graded stone aggregate) 40mm thick on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed (Note :- Rate of WPC shall be included in this unit rate)
M&L for water proofing treatment in following stages:- 1. Rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed. 5. Final coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over APP membrane. Over this layer stone dust @ 0.50 Kg/Sqm shall be applied uniformly.
M&L for providing cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) in roof ,kerb,mud slope rounder or chamfered on edges coping kerb water tough and like incl weathering ,slightly roundered or chamfered angles and thtroating directed incl necessary formwork complete all as specified and directed.
S&F in repairs Aluminum (Die cast body) hydraulic door closer regulated designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width complete all as specified and directed. (Make :- Universal / Everest / Godrej).
Dismantling boarding any description fixed any position with nails complete all as specicified.
S&F Insulated PVC wall lining consisting of PVC Insulatd wall paneles having expandd polstyrene(EPS) to 2mm thick plain coloured PVC sheet 40 mm thick insulated pvc wall lining duly fitted into the wall as per specification and drawing as directed. (Make :- Armstrong / Neel Kamal / Marblex tiles)
S&F MS mortice lock vertical type size 100mm 4 levers complete all as specified and directed. (Make :- Godrej / Horrison / Link / Johnson).
Section-II Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. Notes for Ser Item No 92 & 93 :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
Supply only 15mm bore PVC pipe medium grade inluding fittings. (Make:- Prayag/ Supreme/ Prince.)
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2/4 TR as directed by Engr-in-Charge.
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for indoor of inverter type split AC of capacity 1.5/2 TR as directed by Engr-in-Charge.
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for outdoor of inverter type split AC of capacity 1.5/2 TR as directed by Engr-in-Charge.
Supply only Starting capacitor 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only condenser motor 1/3 HP suitable for window type AC double shaft. (Make-AUE/Crompton Greaves/Cool Master.)
Supply only Starting Relay 1622. (Make:- Hytechh/ Renutrol/ Sri Ram/Microtech.)
Supply only Running capacitor 36 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Thermostat switch 2059/2064/2054. ( Make :- Indfoss/ Renutrol/Godrej).
Supply only copper filter double capilary pencil type.
Supply only regulator knob suitable for 1.5TR/2.0TR capacity AC.
Supply only flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. ( Make -Polycab/Kalinga Premium/Plaza). Note for item No 94 to 108:- Materials of item Nos 94 to 108 to be incorporated in item Nos 92 & 93 here-in-before.
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-134A/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG/Godrej). Note :- Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
ditto- all as per item No. 109 above but window type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG/Godrej)
ditto- all as per item No. 109 above but spilt type Air Conditioner of Capacity 2 TR. (Make:- Emerson /Tecumseh/ LG/Godrej).
ditto- all as per item No. 109 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG/Godrej).
Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.)
ditto- all as per item No 113 above but spilt/window type Air conditioner of capacity 2 TR.
Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete set suitable for 1.5 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/Carrier/Voltas.)
ditto- all as per item No. 115 above but spilt type Air Conditioner of capacity 2 TR. (Make:- LG/Carrier/Voltas.)
Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified & as directed by Engr-in-Charge. (Make:- Nepoleon/ Commander/Camipro/Skoda.)
ditto- all as per item No. 117 above but spilt type Air Conditioner of capacity 2 TR. (Make:- Nepoleon/ Commander/Camipro.)
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)} {Notes :-(i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T / C & S)
Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps iincluding taking down old unservisible metal clad socket complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T / C & S).
Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Material and labour for detecting leakages of gases in window type/ split type AC unit of capacity 1.5/ 2TR at any location, checking the leakages of gas and rectify the leakages by brazing of copper tubes testing and commissioning complete all as specified & as directed by Engr-in-Charge.
Supply and filling refrigerant gas R-22/R-410A/R-32/ R-134A in window type /Split Type AC unit of capacity 1.5/2TR, Deep Freezer, Refrigerator, Water Cooler of any capacity complete in satisfactory working condition. (Make : Mefron/ Floron/ Refron.)
Supply and fixing in repairs of front grill 1.5 TR capacity window type AC approved make complete all as specified & as directed by Engr-in-Charge.
Supply and fixing in repairs of front grill 2 TR capacity window type AC approved make complete all as specified & as directed by Engr-in-Charge.
Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and directed by Engr-in-charge. (Make:- As per sample) (Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.)
ditto- all as per item No. 127 above but split/ window type Air Conditioner of Capacity 2 TR.
Supply & fixing in repairs heavy duty copper pipe of size 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- MALASIA/CEMIPRO/ DIAMOND/STAR)
ditto- all as per item No. 129 above but copper pipe of size 12mm (1/2") dia/ bore.
ditto- all as per item No. 129 above but copper pipe of size 15mm (5/8") dia/ bore.
Supply and fixing of out door stand for Split AC/ Desert cooler of any capacity made up of angle iron frame of any size grouting on wall or floor as directed and applying of two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including taking down old unserviceable one complete all as specified and directed.
Supply & fixing in repair Indoor Air blower motor for Split type AC 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Supply & fixing in repair Window AC air blower motor for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Supply & fixing in repairs Window AC condenser fan blade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
Supply & fixing in repairs Split AC Condenser fan blade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
Supply & fixing in repairs running capacitor of 2.5 MFD capacity complete all as directed. (Make- USHA/EPCOS/KELTRON)
Supply & fixing in repairs running capacitor of 4 MFD capacity complete all as directed. (Make- USHA/EPCOS/KELTRON)
Supply & fixing in repairs running capacitor of 6 MFD capacity complete all as directed. (Make- USHA/EPCOS/KELTRON)
Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as directed by Engr-in-Charge. (Make-LG/Blue Star/Voltas)
Supply & fixing in repairs plastic louvers (Front panel) for Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge.
Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as directed by Engr-in-Charge. {Note:- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set (ii) Supply & filling of refrigerant gas shall be measured and paid under relevent item.}
M&L for 4 mm thick plywood of grade BWR, type BB including necessary fixing accessories and taking down old one and applying two coat of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified & as directed. (Make:- Century/ Dura/ Green ply/ Kitply.)
Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:-Suitable for Voltas/Carrier/LG/ Hitachi/ Blue Star)
ditto- all as per item No. 145 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
Dismantling the evaporator/cooling coil of window type Air Conditioner of capacity 1.5/ 2TR, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing the same complete all as specified & as directed by Engr-in-Charge.
ditto- all as per item No. 147 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable contactor for split type AC of capacity 1.5 TR/ 2.0TR, supply and fixing new contactor single phase suitable for split type AC complete all as specified and directed by Engineer-in-charge.
Disconnection and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete all as specified and directed by Engineer-in-charge.
Disconnection and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete all as specified and directed by Engineer-in-charge.
Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge.
Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC invertor Type of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge.
Dismantling and removing defective burnt blower unit motor of capacity 1.5/ 2.0 TR of any make of window type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and directed by Engineer-in-charge.
Dismantling and removing defective burnt blower unit motor of capacity 1.5/ 2.0 TR of any make of indoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and directed by Engineer-in-charge.
Dismantling and removing defective burnt blower unit motor of capacity 1.5/ 2.0 TR of any make of outdoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs of blower fan blade of indoor unit for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
Supply and fixing in repair GI Sheet Tray Suitable for Window/ Split Acs of any capacity as per Sample as directed by Engr-in-Charge
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply only following new spare parts of Water cooler unit of capacity 40/80 to 60/120 Ltrs :-
Starting relay suitable for 40/80 , 60/120 Ltr. (Make: Sri Ram/Renutrol/Micro Tech / Hytechh).
Running Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
Running Capacitor 10 MFD . (Make:- Usha/Epcos/Keltron)
PVC flexible drain Hose pipe 40 mm. (Make :- PRAYAG/SUPREME/PRINCE)
Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP . (Make: Tipcon/ Usha/Epcos/Keltron)
Over load protector device for 60/120 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
Over load protector device for 40/80 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
Tharmostat switch. (Make: Indfoss/Renutrol/Godrej.)
Self closing chromium plated push taps for water cooler Capacity 40/80,60/120 Ltr. (Make: Usha/Prayag/ Cera/ Essco) Note for item No 161.01 to 161.09 :- Materials of item No 161.01 to 161.09 to be incorporated in item No 160 here-in-before
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 60/120 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vaccum on the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG/Godrej).
ditto- all as per item No. 162 above but Water cooler of capacity 40/80 Ltrs.
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120 Ltr and supply and fixing of new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves / Cool Master)
All as per item No. 164 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs.
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all as specified & as directed.
Dismantling the evaporator/cooling coil of water cooler capacity 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified & as directed by Engr-in-Charge.
Cleaning & removing the existing paint of Water Coolers capacity 60/120 & 40/80 Ltrs by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour as approved by E-in-Charge.
Taking up or down steel tubing and connections and removing off site 15mm bore of pipe complete all as specified and as directed.
Spply and fixing galvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor for water cooler complete all as specified and as directed. (Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
Supplying and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions complete all as specified and as directed. (Make :- ESCCO/ CERA/PARAY WARE/HIND WARE)
Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff/Supreme/Prince).
Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
Disconnecting from mains and taking down for servicing of Refrigerator/Deep freezer of Capacity 165/180/195/310/330/450 and 500 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
Thermostat switch with Knob.( Make :- Indfoss/ Renutrol/Godrej).
Starting relay 1/6 H.P. Open type with O.L.P. ( Make :- Renutrol/ Sri Ram/ Microtech/Hytechh).
Starting relay 1/8 H.P. open type with O.L.P. ( Make :- Renutrol/ Sri Ram/ Microtech/Hytechh).
Copper filter single capilary pencil type.
Vegetable tray PVC for 165 to 330 Ltr capacity ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.).
Defrost tray for refrigerator capacity 165 to 330 Ltr ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.).
PVC ice tray flexible.( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Refrigerator bottle shelf for 165 to 330 ltr capacity ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Waste water tray suitable for different type of Refrigerator. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Freezer door for 165/180/195 Ltr capacity. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Freezer door for 280/300/330 Ltr capacity. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Door Lock for refrigerator 165 to 330 ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Door switch for refrigerator 165 to 330 ltrs . ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Interior light fittings with bulb. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Door handle suitable for 165 to 330 Ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Refrigerator Glass shelves of capacity 165/180/195 Ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.) Note for item No 176.01 to 176.17 :- Materials of item No 176.01 to 176.17 to be incorporated in item No 175 here-in-before
Disconnecting from mains and taking down the unserviceable compressor unit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacity alongwith test certificate from manufacturer including supply of the refrigerant gas R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. (Make :Tecumseh/LG/Godrej/Emerson). Note :- The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
All as per item No. 177 above but following capacity of Refrigerator:-
Refrigerator 280/300/310/330 Ltrs capacity.
Deep Frteezer 400 Ltrs capacity.
Deep Freezer 500 Ltrs capacity.
Taking out unserviceable evaporator /freezer from the refrigerator & supply & fixing evaporator/freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltr with freezer frame and door including connection, complete all as specified & as directed. (Make - Whirlpool/Godrej/Kelvinator/LG/Sumsung.)
ditto- all as per item No. 179 but capacity of the refrigerator 165 to 195 Ltrs capacity.
Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height / floor and refixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs wood wool pad approximate weight 800 - 900gms of size 24” sweep desert cooler as per existing complete all as specified and directed.
ditto- all as per item No 183 above but approximate weight 700 - 800gms and 20” sweep.
Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- Bajaj/ Crompton/ Khaitan.)
Supply and fixing in repairs of exhaust fan motor copper wounded having 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton/ Cool master.)
Supply and fixing in repairs of desert cooler copper wounded kit fan motor of capacity 90 Watt complete all as specified & as directed. (Make Khaitan/ USHA/ Crompton Greaves/Bajaj.)
Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
Supply & fixing in repairs GI wire mesh for desert cooler pad (Set of Three).
Supply & fixing in repairs PVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed. (Make:- Prayag/ Supreme/ Prince).
Supply & fixing in repairs PVC elbow for desert cooler of suitable size complete all as specified & as directed.
Supply & fixing in repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
S&F in repairs flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. ( Make -Polycab/Kalinga Premium/Plaza).
S&F in repairs desert coolers fan blade of 18 inch sweep of plastic body complete all as specified & as directed..
ditto- all as per item No 194 here-in-before but 20 inch sweep.
Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed.
S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Section - III Dismantling/opening up existing ceiling fan size of 1200 mm sweep, taking out all burnt/damaged windings insulating materials & cleaning internally as well as externally, rewinding the fan motor with super enamelled copper wire as per existing size/specification, replacement of complete insulating materials, varnishing drying up, cleaning & greasing of bearing/buses using new grease, reassembling and testing and transporting back to site and refixing to original position. The rates quoted by the contractor shall deemed to include replacement of defective slip pin and roller rubber if worn out and connecting wire of 3 core 1.5 Sqmm pvc flexible copper wire upto 1.0 mtr complete all as specified & as directed.
Ditto- all as per item No 202 here-in-before but exhaust fan size 450 mm sweep.
Ditto- all as per item No 202 here-in-before but exhaust fan size 230/300 mm sweep.
Ditto- all as per item No 202 here-in-before but wall mounted fan 300 mm sweep.
Taking down connecting and dismantling of ceilings fans including fan blades, down rod, coupling, decorative caps, condenser housing, stator and rotor for inspection and replacement of defective parts complete all as specified including complete overhauling/greasing reassembling and testing to achieve satisfactory performance, refixing after repair complete all as specified and directed by Engineer-in-Charge for the following stated below as (a) & (b) :- Note (a) Spare parts required shall be measured and paird separeately as supply only under relevant items of this schedule hereinafter (b) Painting shall be measured & paid separeately (c) Material required for overhauling such as grerase, oil, etc shall deemed to be included in rate quoted. Ceiling fan of sweep 1200mm/1400mm
Complete all as item No 206 above but exhaust fan of size 450mm size sweep.
Complete all as item No 206 above but exhaust fan of size 230/300mm size sweep.
Supply only capacitor (ISI marked) 4 mfd Make : Asian/Crompton Greaves/usha/Havell/ Bajaj
Supply only capacitor (ISI marked) 2.5 mfd Make : Asian/Crompton Greaves/usha/Havell/ Bajaj
Supply only rubber bush for capactitor (as per Sample)
Supply only split pin (as per sample)
Supply only rubber reel (as per sample)
Supply only shackle for ceiling fan with nut and bolts (ISI marked)
Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge
Supply only fan blade suitable for 1200/1400mm sweep complete all as specified & as directed. (Make- As per sample)
Supply only exhaust fan blade suitable for 230/300/450mm sweep complete all as specified & as directed. (Make- As per sample)
Supply only ball bearing/bush for exhaust fan/celing fan of any size complete all as specified and as directed. (Make : TATA/NBC/SKF) Note for item No 209 to 218:- Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate of Item No 206, 207 & 208 here- in- before.
Material and labour for preparing ceiling fan surfaces for painting by removing/cleaning dust and deposited material and apply one coat of white enamelled paint by spray to fan blades, body and down rod, canopy of ceiling fans complete all as specified and as directed
Taking out unserviceable ceiling fan and deposit to MES store, supply and replacement with ceiling fan 230V, 50 Hz, AC 1200 Sweep, min air delivery CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod along with steel wire ropw for additional safety in ceiling fan with all allied accessories and connecting up with three core 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed by Engr-in-Charge Make : Crompton/Havells/Bajaj/Polycab
Taking down deteriorted louvres and supplying and fix new louvers fixed type made out of 16SWG GI sheet with machine pressed cut for horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x 3mm flat iron based size of 45cmx45cm complete all as specified and directed by Engineer-in-Charge
Material and labour for preparing exhaust fan of any size surfaces for painting by removing/cleaning dust and deposited material and applying one coat of grey enamelled paint by spray to exhaust fan body, blades and louvrs complete all as specified and as directed by Engr-in-Charge
Cutting hole in existing concrete or brick wall suitable for fixing 300mm/450mm sweep exhaust fan making good the hoel including proper internal plaster work and surfaces finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge
Taking out unserviceable exhaust fan and deposit to MES store, supply and replacement with exhuast fan, 3/4 blade heavy duty double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connection as required at site with flexible copper cable complete all as specified and directed by Engr-in-Charge Make : Crompton/Havells/Bajaj/Polycab
Supply & Fixing in repair of LED recessed mounting square slim LED down lighter 36 Watt for AS/GB/POP ceiling 2'x2' size complete with internally prewired and connecting up with twin core flexible copper conductor cable of suitable size including takng down of old unserviceable one complete all as specified and directed. (Make : Havells /Phillips / Surya Roshni Ltd / Bajaj/Crompton.)
Taking down carefully existing surface/concealed unserviceable copper/Aluminium point wiring (light, fan socket or power) complete with fittings such as switches, ceiling rose, lamp holder, regulators, sockets, F/Tube/Sketch light fittings, wooden terminal box, plastic laminated sheet cover, from Teak Wood batten including Teak Wood batten or PVC conduits complete all as specified & as directed.
M & L for point wiring using 1.50 sqmm size FRLS, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size FRLS stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly for one light / Fan / exhaust fan / Bell point controlled by one, one way switch complete all as specified & directed by Engr-in-Charge. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST)
All as per item No. 227 above but for one 5 pin 5/6 Ampere socket outlet point controlled by one, one way switch on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No. 227 above but for one 5 pin 5/6 Ampere socket outlet point controlled by one, one way switch on independant board complete all as specified and directed by Engr-in-Charge.
M & L for point wiring for one 15/16 Ampere socket outlet independent point using 2.50 sqmm FRLS size (Nominal cross sectional area), PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade concealed (not less than 25 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm FRLS size stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed. (Make of cable:- NICCO/FINOLEX/RR KABEL/HAVELL'S/POLYCSuitable color code of wire must be ensure for phase / neutral / earth).
Supply & Fixing in repair socket out let 2 in 1, 3/5 Pin, 15/16 Ampere, 230V AC, flush type complete all as specified and as directed. (Make : Anchor / Cona / Kinjal / Havells)
Supply & Fixing in repair ceiling rose, 3 phase, PVC / polycarbonate, surface type, 65mm x 50mm, insulated body, three terminals complete all as specified and as directed. (Make : Anchor / Ess Ess Kay / Havells/ Cona)
Supply & Fixing in repair modular switch one module, 15/16 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand / Indo Asian (Glint))
Supply & Fixing in repair of modular socket outlet (two module) 5/6 amps, 2 in 1, 2 & 3 pin combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand/ Indo Asian (Glint) )
Supply & Fixing in repair of modular socket out let (two module), 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Amp combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Crabtree / Legrand / Indo Asian (Glint))
Supply & Fixing in repair of electric ding dong bell, 230 volt AC, single pole, complete all as specified and as directed by Engineer-in-Charge. (Make :- Anchor / Cona / Wipro / Bajaj/Havells)
Supply & Fixing in repair of flush type bell push, 5 Amps complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Kinjal / Havells)
Supply & Fixing in repair of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed. (Make : Anchor / Ess Ess Kay / Plaza / Havells)
Supply & Fixing in repair of stepped type 5 steps 100 watts electronic fan regulator flush type on the existing phenolic laminated sheets etc as required all as specified and as directed. (Make : Anchor / Havells / Usha / Crompton / Bajaj)
Supply & Fixing in repair of Modular Fan regulator step type, 1 Module size complete all as secified and as directed. (Make: Havells / Legrand/ Crabtree/ Anchor)
Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed.
Material and labour for sub main wiring with two runs of single core 4.0 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC Conduit (heavy grade) of 20mm dia or more dia with all fittings and accessories surface type including one run 4.0 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed by Engr-in-Charge. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST) Note : (a) Two run of 4.00 sqmm copper cable and one run of 4.00 sqmm copper cable (earth wire) alongwith PVC conduit measured as one unit length. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Suitable colour code of wire shall be maintained for phase / neutral / earth).
Material and labour for sub main wiring with two runs of single core 6.0 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC Conduit (heavy grade) of 20mm dia or more dia with all fittings and accessories surface type including one run 6.0 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed by Engr-in-Charge. Make of cable : RR Kable / Plaza / Finolex / Havells / Polycab. Make of Conduit : Finolex / ICL / Ess Ess Kay / Indo American Electricals. Note : (a) Two run of 6.00 sqmm copper cable and one run of 6.00 sqmm copper cable (earth wire) alongwith PVC conduit measured as one unit length. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Suitable colour code of wire shall be maintained for phase / neutral / earth).
Material and labour for sub main wiring with two runs of single core 10.0 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC Conduit (heavy grade) of 25 mm dia or more dia with all fittings and accessories surface type including one run 10.0 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST) Note : (a) Two run of 10.00 sqmm copper cable and one run of 10.00 sqmm copper cable (earth wire) alongwith PVC conduit measured as one unit length. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Suitable colour code of wire shall be maintained for phase / neutral / earth).
Supply & fixing retrofit LED lamp 7 watt complete all as specified and directed Make : Bajaj/Havells/Phillips/Cromption/Wipro
Supply and fixing in repairs modular White cover plate with frame, 3 module size as per site requirement complete all as specified and as directed. (Make : Anchor / Cona / Crabtree / Legrand)
Supply and fixing in repairs modular White cover plate with frame, 4 module size as per site requirement complete all as specified and as directed. (Make : Anchor / Cona / Crabtree / Legrand)
Supply and fixing in repairs modular White cover plate with frame, 6 module size as per site requirement complete all as specified and as directed. (Make : Anchor / Cona / Crabtree / Legrand)
Supply and fixing in repairs modular White cover plate with frame, 8 module size as per site requirement complete all as specified and as directed. (Make : Anchor / Cona / Crabtree / Legrand)
Supply and fixing in replacement of modular metal flush box, 1.6 mm thick, 4 module,mounting in the wall for fitting cover plate with frame on switch/socket complete all as specified and as directed. (Make : Anchor / Cona / Crabtree / Legrand)
Supply and fixing in replacement of modular metal flush box 1.6 mm thick, 6 module,mounting in the wall for fitting cover plate with frame on switch/socket complete all as specified and as directed. (Make : Anchor / Cona / Crabtree / Legrand)
Supply and fixing in repairs PVC Gang Box suitable for one No 15 Amps Switch and Socket complete all as specified and as directed. (Make : Presto Plast/Pressfit/Polyplast.)
Supply and fixing in repair of PVC casing & caping of size 20 mm inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples,PVC Rawal Plugs, saddles, etc including making surface good as original by plastering and whitewash/ colour/ distemper etc including taking down old unserviceable one complete all as specified and as directed. (Make: Finolex/ Plaza/ Kalinga/ Supreme/ Bajaj/ Prince)
Supply and fixing switch piano, flush type, ivory finish 5/6 Ampere single pole, one way complete all as specified and as directed. (Make : Anchor / Cona / Kinjal / Havells)
Supply and fixing socket out let 2 in 1, 3/5 pin, 5/6 Ampere, 230V AC, flush type complete all as specified and directed. (Make : Anchor / Cona /Kinjal / Havells)
Supply and fixing switch piano, flush type, ivory finish 15/16 Ampere single pole, one way complete, all as specified and as directed. (Make : Anchor / Cona /Kinjal / Havells)
Supply and fixing modular switch one module, 5/6 Amp, one way, 230 volts AC complete all as specified and directed. (Make : Anchor / Cona / Crabtree / Legrand / Indo Asian (Glint)).
Supply and fixing Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver LED tube light fitting 20 watt including LED tube, 230 volt complete all as specified and directed. (Make :Havells cat part No LUMILINEBS9WLED830SPCWH or equivalent model of make Phillips / Surya Roshni Ltd / Bajaj/ Crompton Greaves/ C & S Electric)
Supply and fixing Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver LED tube light fitting 9 watt including LED tube, 230 volt complete all as specified and directed by Engr-in-charge. (Make :Havells cat part NoLUMILINEBS9WLED830SPCWH or equivalent model of make Phillips / Surya Roshni Ltd / Bajaj/ Crompton Greaves/ C & S Electric) Note for Item no 84 to 90: Labour charges for replacement of materials shall deemed to be included in unit quoted rate of Item No 83 here- in- before.
M & L for cutting channels, grooves or rebates exc 15 cm but n exc 30cm girth and trimming surface and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and as directed.
Supply and fixing in repair MCB Metalica Distributition board, Double door, concealed flush to wall for mounting MCBs, factory made , conforming to IS : 13032 fabricated out of CRCA sheet not less than 1.20 mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar. DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature , between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified , the DBs shall be of IP 42 protection class for the following complete all as specified and as directed.
TPN 4 way, 415 Volts TPN Metalica Distribution Board. (Make- L & T/Legrand/ Siemens/ ABB/ Schneider)
SPN 12 way, 230 Volts SPN Metalica Distribution Board. (Make- L & T/Legrand/ Siemens/ ABB/ Schneider)
SPN 8 way, 230 Volts SPN Metalica Distribution Board. (Make- L & T/Legrand/ Siemens/ ABB/ Schneider)
SPN 4 way, 230 Volts SPN Metalica Distribution Board. (Make- L & T/Legrand/ Siemens/ ABB/ Schneider)
Supply and fixing in repairs miniature circuit breaker (MCB) single pole and neutral 240 volts, 40 Ampere current rating, 'C' curve, 10 KA breaking capacity complete all as specified and directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T).
Ditto all as per item No 266 above but for SPN 6 to 32 Amps current rating.
Ditto all as per item No 266 above but for SP 6 to 32 amps current rating.
Ditto all as per item No 266 above but for 'B' curve SP 40 Amps current rating.
P S TRADERS
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .