Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.3 L+₹3.8 L (9.10%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹45.3 L+₹3.8 L (9.24%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹54.1 L+₹12.6 L (30.4%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹59.4 L+₹17.9 L (43.2%)Rejected-Finance | L5 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | BRITE INDUSTRIES L3 | Mahindra Electric Stores L4 | M/s Vijay Airconditioning Pvt Ltd L1 | somnath engineering corporation L5 | AIRDOT ENGINEERING L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supplying testing and commissioning of following, VRF air conditioning system, outdoor unit (ODU) complying OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 43 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on angle iron frame or suitable foundation connected to the system in approved manner complete of the following capacity VRF Out door unit complete all as spd and directed by Engr-in-Charge:- | ||||||||
| 1.01 | 44 HP (20+24) Note- if this specific breakup is unavailable in the market, the final selection of the outdoor unit configuration will be determined by the Engineer-in-Charge during the approval stage, ensuring compliance with project requirements and technical feasibility. | 1 | Job | 9,85,000 ₹9,85,000 | 12,50,000 ₹12,50,000 | 10,50,000 ₹10,50,000 | 11,25,750 ₹11,25,750 | 9,60,000 ₹9,60,000 Lowest |
| 1.02 | 30 HP (15+15) Note- if this specific breakup is unavailable in the market, the final selection of the outdoor unit configuration will be determined by the Engineer-in-Charge during the approval stage, ensuring compliance with project requirements and technical feasibility. | 1 | Job | 7,55,000 ₹7,55,000 | 9,00,000 ₹9,00,000 | 7,10,000 ₹7,10,000 Lowest | 8,75,000 ₹8,75,000 | 7,48,000 ₹7,48,000 |
| 2.00 | Supply, installation, testing and commissioning of VRF based ceiling suspended 4 Way cassette room/indoor unit (IDU-Large size) of nominal cooling capacity 3 TR having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. arrangements. IDU with drainage fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh airport etc. suitable to operate on 1-phase, 230 V, 50HZ, AC supply complete. The quoted rate includes the initial filling of refrigerant gas and compressor gas (if applicable) , any core cuttings required for copper pipe/drainage/communication cable, suitable size drainage pipe, all as deemed necessary by the contractor. | 24 | Each | 52,500 ₹12,60,000 | 60,000 ₹14,40,000 | 50,000 ₹12,00,000 Lowest | 58,000 ₹13,92,000 | 51,000 ₹12,24,000 |
| 3.00 | Supplying, laying, testing & commissioning of appropriate nominal refrigerant copper pipe (Soft drawn/hard drawn) of suitable sizes as per OEM standards along with necessary supports with OEM approved thickness elastomeric nitrile rubber insulations.Core cutting to be included | 722 | RM | 1,300 ₹9,38,600 | 2,000 ₹14,44,000 | 900 ₹6,49,800 Lowest | 2,450 ₹17,68,900 | 1,470 ₹10,61,340 |
| 4.00 | Supplying and installation of high-pressure grade required size copper connection Y joints/refnet complete erected on wall ceiling with supports/raceways, Nitrile rubber insulation etc. with brazing and testing for leakages confirming the normal operation of the VRF air conditioning system | 26 | SET | 4,000 ₹1,04,000 | 4,000 ₹1,04,000 | 4,500 ₹1,17,000 | 4,800 ₹1,24,800 | 3,750 ₹97,500 Lowest |
| 5.00 | Supply, fixing and commissioning of refrigerant joint Branch distibutors between Outdoors complete with nitrile rubber insulation, supporting etc.. complete as required. | 5 | SET | 6,000 ₹30,000 | 4,000 ₹20,000 Lowest | 4,816 ₹24,080 | 15,000 ₹75,000 | 5,900 ₹29,500 |
| 6.00 | Providing & fixing of Rigid UPVC pipe complete with fittings, supports as per specifications and duly insulated as per standard engineering practice of closed cell nitrile rubber insulation in surface/recess i/c cutting the wall in case of recess making good the same etc. as reqd by Engr-in-charge. | 250 | RM | 280 ₹70,000 | 150 ₹37,500 Lowest | 258 ₹64,500 | 150 ₹37,500 Lowest | 220 ₹55,000 |
| 7.00Supplying & fixing powder coated MS 2 mm thick cable tray along with suitable copler plate, suitable size runner, threaded rod, fastner duly fixed to wall/roof along with all cable try fittings such as Tee, Reducers, bends etc all as directed by EIC of the following size :- | ||||||||
| 7.01 | 300 mm width X 50 mm depth X 1.6mm thickness | 90 | RM | 780 ₹70,200 | 600 ₹54,000 Lowest | 700 ₹63,000 | 750 ₹67,500 | 760 ₹68,400 |
Tender Value
₹46.2 L
EMD Value
₹92,500
Closing Date
14 Aug 2025, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8611 SPECIAL REPAIRS/ RENEWAL OF VARIABLE REFRIGERANT FLOW (VRF) ACS IN REPLACEMENT OF BER ACS AT BANQUET/ EXAMINATION HALL (APRAMEYA) ALONG WITH OTHER CONNECTED ACCESSORISES AT AFMC UNDER GE (CENTRAL) PUNE
2025_MES_720912_1
8611 SPECIAL REPAIRS/ RENEWAL OF VARIABLE REFRIGERANT FLOW (VRF) ACS IN REPLACEMENT OF BER ACS AT BA
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹92,500
Yes
24 Sept 2025
17 Jul 2025
16 Aug 2025
17 Jul 2025
14 Aug 2025
31 Jul 2025
Amount
Supplying testing and commissioning of following, VRF air conditioning system, outdoor unit (ODU) complying OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 43 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on angle iron frame or suitable foundation connected to the system in approved manner complete of the following capacity VRF Out door unit complete all as spd and directed by Engr-in-Charge:-
Supply, installation, testing and commissioning of VRF based ceiling suspended 4 Way cassette room/indoor unit (IDU-Large size) of nominal cooling capacity 3 TR having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. arrangements. IDU with drainage fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh airport etc. suitable to operate on 1-phase, 230 V, 50HZ, AC supply complete. The quoted rate includes the initial filling of refrigerant gas and compressor gas (if applicable) , any core cuttings required for copper pipe/drainage/communication cable, suitable size drainage pipe, all as deemed necessary by the contractor.
Supplying, laying, testing & commissioning of appropriate nominal refrigerant copper pipe (Soft drawn/hard drawn) of suitable sizes as per OEM standards along with necessary supports with OEM approved thickness elastomeric nitrile rubber insulations.Core cutting to be included
Supplying and installation of high-pressure grade required size copper connection Y joints/refnet complete erected on wall ceiling with supports/raceways, Nitrile rubber insulation etc. with brazing and testing for leakages confirming the normal operation of the VRF air conditioning system
Supply, fixing and commissioning of refrigerant joint Branch distibutors between Outdoors complete with nitrile rubber insulation, supporting etc.. complete as required.
Providing & fixing of Rigid UPVC pipe complete with fittings, supports as per specifications and duly insulated as per standard engineering practice of closed cell nitrile rubber insulation in surface/recess i/c cutting the wall in case of recess making good the same etc. as reqd by Engr-in-charge.
Supplying & fixing powder coated MS 2 mm thick cable tray along with suitable copler plate, suitable size runner, threaded rod, fastner duly fixed to wall/roof along with all cable try fittings such as Tee, Reducers, bends etc all as directed by EIC of the following size :-
300 mm width X 50 mm depth X 1.6mm thickness
150 mm width X 50 mm depth X 1.6mm thickness
Providing and fixing of 2 core 1.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication indoor and out door as per manufacture standard between indoor unit/outdoor unit controllers inside building in existing steel/PVC Conduit, on surface/existing channel, i/c making connection etc as reqd
Supplying and Laying of XLPE insulated, PVC sheathed Copper conductor 1.1 KV grade armoured U.G.Cable of following sizes on surface in existing cable traylin existing pipe/ in surface/recess etc. of size 4 core x 10 Sq.mm Copper Cable Armourd all as directed by EIC.
Supplying and making end termination with brass compression gland and pvc sheathed / XLPE aluminium/copper conductor cable of size 4 Core x 10 sqmm , 1.1 KV grade.
Supplying and fixing suitable size PVC/FRP weather proof enclosure outdoor type on surface/ racess along with MCB 63 Amp four pole (three phase and neutral ), 415 volts, residual current circuit breaker (RCCB 63 Amp) having a sensivity current 100 mA complete with connections, testing and commissioning etc. including indoor unit power point also
Dismantling of existing UNSV AC's 3 TR Window/Split/Cassete AC along with connected items and deposite to AGE E/M store Yard for further disposal.
AIRDOT ENGINEERING (BID ID -3386383)
BRITE INDUSTRIES (BID ID -3386378)
Mahindra Electric Stores (BID ID -3392942)
somnath engineering corporation (BID ID -3393686)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .