Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹94.9 L
EMD Value
₹1.9 L
Closing Date
27 Oct 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VISHWNATH KHICHI
ED - Karnal
Replacement of LAN and EPABX system install in Judicial Court Complex Karnal
2025_HRY_478272_1
2025CA2402EC 62CE 4202 9B04 D9A40E025B06665BAR
Open Tender
Civil Works
Works
90 days
Karnal
2 documents required · 2 mandatory
₹5,000
₹1.9 L
Yes
30 Oct 2025
15 Oct 2025
28 Oct 2025
16 Oct 2025
27 Oct 2025
16 Oct 2025
16 Oct 2025 - 18 Oct 2025
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer Electrical Division PWD B&R Br., Karnal
Name of Work: Replacement of LAN and EPABX system install in Judicial Court Complex Karnal
DNITRs. 94.95 Lakhs
Name of the Bidder/ Bidding Firm / Company :
Sl. No. HSR Items / Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] BI01010001010000000000000515BI0100001113 15750 Metre 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
2 [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] BI01010001010000000000000515BI0100001114 3850 Metre 2 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
3 Supply and Laying of 50 Pair multicore Telephone cable conductor size 0.51mm bright annealed copper conductor PVC insulated and shealed in existing pipe / Channel etc. (excluding the cost and laying of pipe / channel) and making necessary connection complete in all respect . Make:- Delton / Shalimar / Polycap/ Phenolex. BI01010001010000000000000515BI0100001115 180 Metre 3 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
4 SITC IP-PBX with Configuration, User expandable up to 94 Ports Lines with Following Configuration: - 40 Analog Users 8 digital users The system should support ISDN PRI - 01 04 Analog Trunks 01 Operator Console. a) Remote Maintenance Facility b) Web Based management software c) Call Accounting Software-01 d) DISA and DOSA Facility e) Wall / Rack Mountable System f) Call Control Server / Application should be equipped with Intel / Pentium Based Processer including cost of all material and Labour required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work Make : Avaya /Siemens /MATRIX BI01010001010000000000000515BI0100001116 1 Each 4 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
5 SITC of 2 KVA UPS with 30 min backup on line with Suitables 26 AH batteries. (Makes:-Amersol / Microtek / Elnova) BI01010001010000000000000515BI0100001117 29 Each 5 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
6 Supply, Installation, Testing and commissioning of KTS PHONE with wide LCD display, soft keys with LED status indication navigation keys show name facility for direct dialing feature keys like: message, configration, emergency Misc. etc. Make -Alcatel/ AVAYA/ MATRIX BI01010001010000000000000515BI0100001118 2 Each 6 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
7 Supply, Erection testing and Commissioning of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port, Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks which should be toolless termination. Should have rear cable management shelf metallic powder coated. Make: RandM,/Molex/D-Link BI01010001010000000000000515BI0100001119 29 Each 7 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
8 S/E/T/C of UTP Cat-6 information outlet Make and Model: RandM/Dlink/Molex BI01010001010000000000000515BI0100001120 550 Each 8 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
9 S/E/T/C of Push Button Telephone Desktop model CLI, flash , redial complete in all respect. Make :-Beetel BI01010001010000000000000515BI0100001121 73 Each 9 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
10 S/E/T/C of multicore 20 Pair Telephone cable conductor size 0.51mm bright annealed copper conductor PVC insulated and shealed in existing pipe / Channel etc. (excluding the cost and laying of pipe / channel) and making necessary connection complete in all respect . Make:- Delton / Shalimar / Polycap/Phenolex. BI01010001010000000000000515BI0100001122 275 Metre 10 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
11 S/E/T/C of Face plate (Single / Dual) Make and Model: RandM/Dlink/Molex BI01010001010000000000000515BI0100001123 625 Each 11 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
12 S/E/T/C of 50 Pair IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities BI01010001010000000000000515BI0100001124 6 Each 12 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
13 S/E/T/C of Telephone Jack of MK make. BI01010001010000000000000515BI0100001125 75 Each 13 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
14 S/E/T/C of 20 Pair IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities BI01010001010000000000000515BI0100001126 2 Each 14 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
15 Supply Installation Testing and Commissioning of Wall mounted 9U enclosure of dimension600W X9UX500D with front sheet steel glass door, top and bottom cCover with cable entryprovision, integrated side walls,1 pair of 19` angles with wall mounting provision, captivehardware(pack of 20) complete in all respect upto entire satisfaction Engineer in charge ofworks. Make COMRACK/Dlink/Valrack. . BI01010001010000000000000515BI0100001127 29 Each 15 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
16 Supply Installation Testing and Commissioning of 6 core mm fiber cable (per meter) complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer - in - charge of the work. Make : Dlink / Molex / RandM BI01010001010000000000000515BI0100001128 1400 Metre 16 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
17 Supply Installation Testing and Commissioning of 2 Core Power Cable 1.5 sqmm. complete in all respects up to the entire satisfaction of the Engineer-in-charge of work Make: Finolex / Polycab / Havells BI01010001010000000000000515BI0100001129 650 Metre 17 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
18 Supply Installation Testing and Commissioning of 12F, 1U, LC, LIU Loaded with Pigtails, Splice tray, Couplers as per specification complete in all respects up to the entire satisfaction of Engineer-in-charge of work Make: Dlink / Molex / RandM BI01010001010000000000000515BI0100001130 29 Each 18 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
19 Supply Installation Testing and Commissioning of PATCH CORD LC-LC SM DUPLEX Lenth- 3mtr.As per specification complete in all respects up to the entire satisfaction of the Engineer-in-charge of work Make: Dlink / Molex / RandM BI01010001010000000000000515BI0100001131 60 Each 19 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
20 Supply Installation Testing and Commissioning of 1G SFP module as required (For All Switches) complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: Zyxel / Cisco / Nexxus BI01010001010000000000000515BI0100001132 60 Each 20 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
21 Supply Installation Testing and Commissioning of 24 Port Access Switch with 24x 1G Base-Tand 4x1G SFP Slots Console port 1 Console port 1 Primary power internal 1 fan Switch capacity with all ports (full duplex) 56 Gb/s Switch frame rate @ 64 byte packet 41.7 Mpps System power consumption: • Idle • 100% traffic all ports Operating temperature Operating temperature 0°C to 50°C (32°F to 113°F Storage temperature -20°C to 60°C (-4°F to 140°F) Fixed 1RU chassis 24 RJ 45 10/100/1G BaseT, 4 SFP (1G) uplink ports. Fan-less complete in all respects up to the entire satisfaction of the Engineer-in-charge of work. Make: Zyxel / Cisco / Nexxus BI01010001010000000000000515BI0100001133 29 Each 21 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
22 Supply Installation Testing and Commissioning of 24 port Core Switch (L3 switch) with 16x10G SFP plus with 8 Multi-Gigabit combo(100M/1G/2.5G/5G/10G) RJ-45/SFP and 4 100M/1G/2.5G/5G/10G Ethernet (RJ-45) with minimum switching capacity of 560 Gbps and forwarding rate: 416 mpps, 8 GB RAM, , should support stacking up to 4 switches with stacking bandwidth of 160Gbps. It should have Dual Power Supply, AC voltage: 90 to 260V (auto-ranging), Tri-authentication: MAC- based, web-based and IEEE 802.1x, Access Control Lists (ACLs) based on layer 3 and 4 headers, , Static Routing, RIPv2, OSPFv2, ,, Built-in CPU protection against malicious attacks, Switch should be EU RoHS compliant,.Operating temperature range: 0°C to 50°C (32°F to 113°F) Derated by 1°C per 305 meters (1,000 ft), Certification:CE, FCC ,LVD, BSMI Stacking cables and associated accessories will be provided with switch complete etc. as required Make: Zyxel / Cisco / Nexxus BI01010001010000000000000515BI0100001134 1 Each 22 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
23 Supply Installation Testing and Commissioning of PVC Cable Manager finger duct type completes the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. Make: Legrand / Corning /Comrack BI01010001010000000000000515BI0100001135 29 Each 23 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
24 Supply Installation Testing and Commissioning of UTP cat 6 Mounting 3 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM BI01010001010000000000000515BI0100001136 550 Each 24 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
25 Supply Installation Testing and Commissioning of UTP cat 6 Mounting 7 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM BI01010001010000000000000515BI0100001137 550 Each 25 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
26 Supply Installation Testing and Commissioning of 42U, 800w x 1000d, 19` Comms equipment rack with front 19` rails and dual 8 to 12-outlet PDUs, and mesh-screen front and rear lockable doors, ventilated top cover with cable glands complete the job in all respects up to the entire satisfaction of Engineer-in-charge of work Make: HiveNetwork / Comrack / Netrack BI01010001010000000000000515BI0100001138 1 Each 26 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
27 Supply , installation, testing and commissioning of 30 KVA Online UPS with 30 Minutes power Backup with( 32 No. Battery of suitable Ah Rating) with necessary MS stand for batteries and UPS) all necessary accessories civil electrical works and peripheral items. Make:- MICROTEK / ELNOVA / EATON BI01010001010000000000000515BI0100001139 1 Each 27 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
28 Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. 2 pair Telephone wire BI01010001010000000000000515BI0100001140 2850 Per Metre 28 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.29 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_556232.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .