Purchase of Lab Equipments for EEE Department
2026_DoTE_695600_1
3806/A4/2026
Limited
Electrical Goods/Equipments
Item Wise
GPTC, Usilampatti
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Yes
19 Aug 2026
19 Aug 2026
3 Sept 2026
19 Aug 2026
2 Sept 2026
19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | 3 Phase Auto Transformer Starter
SPECIFICATIONS :
3-phase variable autotransformer
Input: 415 V
Output: 0–470 V AC (continuous)
Current: 15 A
Copper wound, carbon brush type
Heavy duty toroidal/core construction
Mounted in powder coated MS/CRCA enclosure
Front panel mounted voltage control knob with scale indication
Proper insulated terminals provided
Floor/bench mounted type suitable for laboratory use
Input/Output terminal arrangement provided
MCB/Fuse protection provided
Proper earthing terminal provided
Ventilation arrangement for heat dissipation | 1 | No | - | - |
| 1.02 | Star Delta Starter Interfacing Kit
Supply: 3-phase, 415 V AC, 50 Hz
Motor Compatibility: 3 HP to 5 HP induction motor, 3 Contactors:
Main contactor
Star contactor
Delta contactor
Thermal overload relay
Timer (adjustable star–delta transition, Control Voltage: 12 V /
24 V DC (isolated)
Interface type:
Relay-based isolation)
Push buttons (Start/Stop), Automatic mode (timer-based), Phase
indication lamps (R, Y, B)
Star mode indicator
Delta mode indicator
Overload/fault indication, Overload protection (thermal relay)
Short-circuit protection (MCB/MCCB)
Phase failure / phase sequence protection (recommended)
Electrical interlocking (Star ↔ Delta) | 1 | No | - | - |
| 1.03 | DoL starter Interfacing kit
Starter Type: DOL starter
Supply: 3-phase, 415 V AC, 50 Hz
Motor Compatibility:
1 HP to 3 HP induction motor
Components:
Contactor (AC-3 duty)
Thermal overload relay
Push buttons (Start/Stop),Control Voltage: 12 V / 24 V DC
(isolated),ON/OFF status indicators
Fault indication (overload trip)
Phase indication lamps,Overload protection (thermal relay)
Short-circuit protection (MCB/MCCB), Wiring diagram displayed
on panel | 1 | No | - | - |
| 1.04 | Conveyor Arrangement with Siren
Input Supply : 12 V DC / 24 V DC / 230 V AC, 50 Hz
Control Mode : Manual / Automatic operation using PLC
Conveyor Arrangement with geared DC motor provided
Proximity sensor provided for object detection
Start and Stop push buttons provided
Audio siren indication provided
PLC based control and sequencing operation provided
Mini conveyor setup suitable for laboratory demonstration
Geared DC motor driven conveyor mechanism
Smooth belt movement with roller arrangement | 1 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.08 MB
BOQ_836391.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].