Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.2 L+₹1.5 L (9.13%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Mar 2022, 6:00 pmClosed
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR MAINT OF STP NO 1,2,3,4 AND 5 AND CHEMICAL FOR STP UNDER AGE E and M JAIPUR
2022_MES_510928_1
GE/J-63/2021-22
Open Tender
Civil Works
Item Rate
270 days
Jaipur
As per NIT
5 documents required · 5 mandatory
₹500
GE Jaipur
₹40,000
Yes
31 Mar 2022
28 Feb 2022
29 Mar 2022
28 Feb 2022
27 Mar 2022
14 Mar 2022
28 Feb 2022 - 13 Mar 2022
Amount
Cleaning of treated water undergroud water storage sump of capacity 50,000 Gln at STP 1, 2, 3, 4 & 5 by specialized water tank clean " TANK CLEAN" process as under :- Note 1 :- All workers will wear mask and carry all necessary T&P for protection and smooth working before start cleaning process. The contractor will take prior permission from Engineer-in-charge in written before starting work and will brief all aspect i.e Date and time of cleaning start and completion so that suitable arrangment may be made to supply water during cleaning process. Contractor will depute manpower in such manner that water supply time do not hamper. (a) Mechanized dewatering and scrubbing the surface of floor and wall till removal of dirt, sendiments, fungus and the stains and cleaning, removal of sludge and shifting as directed. (b) High pressure cleaning. (c) Soak the dirt and sendiments by Vacuum cleaning. (d) Anti bacterial spray on all dimensions inside tank. (e) M&L for marking date of cleaning on tank by using synthetic enemal paint, font design and letter size will be as directed by Engineer-in-charge. (2) Sludge/dirt and other sand debries etc will thrown out to place as directed by Engineer-in-charge. (3) Each STP shall be measured and paid as one Job, If contractor failed/delayed after intimation for cleaning of each plant, penalty @ 20000/- shall be recoverd from his dues and contractor's claim on this account shall not be entertained.
Removing silt ( mud) from sewage pump well at STP 1,2,4&5 (depth 7.5 meter, dia 8.5 meter) and cleaning the bottom portion and sides of pump well by using man power at equal intervel of 6 months from date of commencement of contract, Proper cleaning of sewage tank by following method complete all as mentioned in item No 3.
Removing silt ( mud) from sewage pump well at STP 3 Queens Road (size depth 7.5 meter, dia3.5 meter covered with RCC roof and wall) and cleaning the bottom portion and sides of pump well by using man power at equal intervel of 6 months from date of commencement of contract, Proper cleaning of sewage tank by following method complete all as mentioned below:- Note for item No 2 and 3 :- (a) All workers should be experienced for sewage pump well cleaning and necessary safety equipments including mask and other T&P for workers should be arranged by contractor before start cleaning process. (b) The contractor will take prior permission from engineer in charge in written before starting work and will brief all aspect i.e. Date and time of cleaning start and completion so that suitable arrangement may be made. Contractor will supply T&P and manpower in such manner that cleaning should be done without hampering sewage system. Note -(1) Sludge/dirt and other sand debries etc will thrown out to place as directed by Engineer-in-charge. (2) If contractor failed/delayed after intimation for cleaning of each plant, penalty @ Rs 30000/- shall be recoverd from his dues and contractor 's claim on this account shall not be entertained.
Proper cleaning of RCC stilling chamber, RCC fine bar screen I&II, RCC Grit chamber I&II, RCC Oil and grease chamber, Equalization tank, MBBR tank I&II, Flocculator, Tube settler, CCT, RCC Filter feed tank, RCC slurry/ sludge sump by experienced workers with safety equipments and T&P items required for cleaning of all above said parts of sewage treatment plant of 05 Nos at equal intervel of 01Month from date of commencement of contract complete all as mentioned below:- (a) By mechanised dewatering and scrubbing the surface of floor, wall till removal of dirt, sediments and cleaning sludge removal and shifting as directed. (b) The contractor will take prior permission from engineer in charge in written before starting work and will brief all aspect i.e. Date and time of cleaning start and completion so that suitable arrangement may be made. contractor will supply T&P and manpower in such manner that cleaning should be done without hamper sewage system. Note - (1) Sludge/dirt and other sand debries etc will thrown out to place as directed by Engineer-in-charge. (2) If contractor failed/delayed after intimation for cleaning of each plant, penalty @ Rs 35000/- shall be recoverd from his dues and contractor 's claim on this account shall not be entertained.
M&L for rectification of leakage from 50mm HDPE bore pipe line by cutting & replacement of defective HDPE pipe and refixing the same after cleaning and by connecting with old line with and including necessary fittings HDPE welding (Hot plate welding) for old & new pipe including necessary exacavation & earth work as required complete all as specfied and directed .
M&L for rectification of leakage from 100mm HDPE bore pipe line by cutting & removing 1 meter pipe length of pipe, and refixing the same after cleaning and connecting with old line by providing necessary fittings such as suitable sockets & do HDPE welding (Hot plate welding) for old & new pipe for connecting complete including necessary exacavation & earth work as required for making it serviceable complete all as specfied and directed .
M&L for rectification of leakage from 150mm HDPE bore pipe line by cutting & removing 1 meter pipe length of pipe,and refixing the same after cleaning and connecting with old line by providing necessary fittings such as suitable sockets & do HDPE welding (Hot plate welding) for old & new pipe for connecting complete including necessary exacavation & earth work as required for making it serviceable complete all as specfied and directed .
M&L for rectification of leakage from 250mm HDPE bore pipe line by cutting & removing 1 meter pipe length of pipe, and refixing the same after cleaning and connecting with old line by providing necessary fittings such as suitable sockets & do HDPE welding (Hot plate welding) for old & new pipe for connecting complete including necessary exacavation & earth work as required for making it serviceable complete all as specfied and directed .
Dismentling of centrifugal/ monoblock pump set after disconnecting from power mains & pipe line of capacity 5 HP, 3 phase, 415 volts 50 Hz, AC of make ' Kirloskar" from foundation and dismantling for overhauling repair including replacement of unservicable part oiling , greasing, reinstalling and connecting with suction / discharge line with correct alignment by replacing gland studs and making complete electric connection including testing complete after carring out repairs if any under item No 11.02 to 11.04 complete all as specified and directed. (Note- spare parts required for replacement shall be measured and paid separetaly as supply only and cost of taking out old & fixing new if any ordered for item No 9.02 to 9.04 shall be deemed to be included in quoted rate of this item)
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only stainless steel pump shaft as per existing make.
supply only Gun metal impeller with neck key, distance bush as per existing make.
supply only ball bearing as per existing number and as per existing make.
M&L for Dismantling the non clogging sewage pump ( 5.0 to7.5 HP ) from foundation including electric and mechanical connection and taking out from 10 mtr deep sewage well with chain pulley block and instalation, reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer - in- Charge. Make :Crompton Greaves Ltd, KSB (Note- spare parts required for replacement shall be measured and paid separetaly under item No. 10.02 as supply only and cost of taking out old & fixing new if any ordered for item No 10.02 shall be deemed to be included in quoted rate of this item) (a) Replacement Oil seal. (b) Replacement of Oil. (c) Replacement of hanging chain of suitable size.
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only ball bearing NDE and DE as per existing numbers. Make - NDE/DE or equivalent as approved by GE.
M&L for Dismantling the non clogging sewage pump ( 12.5 HP ) from foundation including electric and mechanical connection and taking out from 10 mtr deep sewage well with chain pulley block and instalation, reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer - in- Charge. Make :Crompton Greaves Ltd, KSB (Note- spare parts required for replacement shall be measured and paid separetaly under item No. 11.02 as supply only and cost of taking out old & fixing new if any ordered for item No 11.02 shall be deemed to be included in quoted rate of this item) (a) Replacement Oil seal. (b) Replacement of Oil. (c) Replacement of hanging chain of suitable size.
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only ball bearing NDE and DE as per existing numbers.
M&L for Dismantling the non clogging sewage pump (3/4 HP ) from foundation including electric and mechanical connection and taking out from 10 mtr deep sewage well with chain pulley block and instalation, reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer - in- Charge. Make :Crompton Greaves Ltd, KSB (Note- spare parts required for replacement shall be measured and paid separetaly under item No. 12.02 as supply only and cost of taking out old & fixing new if any ordered for item No 12.02 shall be deemed to be included in quoted rate of this item) (a) Replacement Oil seal. (b) Replacement of Oil. (c) Replacement of hanging chain of suitable size.
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only ball bearing NDE and DE as per existing numbers. Make - NDE/DE or equivalent as approved by GE.
Dismentling of centrifugal/ monoblock pump set after disconnecting from power mains & pipe line of capacity 7.5 to 15 HP, 3 phase, 415 volts 50 Hz, AC of make ' Kirloskar" from foundation and dismantling for overhauling repair including replacement of unservicable part oiling , greasing, reinstalling and connecting with suction / discharge line with correct alignment by replacing gland studs and making complete electric connection including testing complete after carring out repairs if any under item No 13.02 to 13.04 complete all as specified and directed. (Note- spare parts required for replacement shall be measured and paid separetaly as supply only and cost of taking out old & fixing new if any ordered for item No 13.02 to 13.04 shall be deemed to be included in quoted rate of this item)
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only stainless steel pump shaft
supply only Gun metal impeller with neck key, distance bush
supply only ball bearing as per existing number.
Dismentling of centrifugal/ monoblock pump set after disconnecting from power mains & pipe line of capacity 25 HP, 3 phase, 415 volts 50 Hz, AC of make ' Kirloskar" from foundation and dismantling for overhauling repair including replacement of unservicable part oiling , greasing, reinstalling and connecting with suction / discharge line with correct alignment by replacing gland studs and making complete electric connection including testing complete after carring out repairs if any under item No 14.02 to 14.04 complete all as specified and directed. (Note- spare parts required for replacement shall be measured and paid separetaly as supply only and cost of taking out old & fixing new if any ordered for item No 14.02 to 14.04 shall be deemed to be included in quoted rate of this item)
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only stainless steel pump shaft
supply only Gun metal impeller with neck key, distance bush
supply only ball bearing as per existing number.
Dismentling of filter press pump set /Gear box motor after disconnecting from power mains & pipe line of capacity 1.5 HPto 2 HP , 3 phase, 415 volts 50 Hz, AC from foundation and dismantling for overhauling repair including replacement of unservicable part oiling , greasing, reinstalling and connecting with suction / discharge line with correct alignment by replacing of gear road/pin and making complete electric connection including testing complete after carring out repairs if any under item No 15.02 to 15.05 complete all as specified and directed. (Note- spare parts required for replacement shall be measured and paid separetaly as supply only and cost of taking out old & fixing new if any ordered for item No 15.02 to 15.05 shall be deemed to be included in quoted rate of this item)
Transportation of motor to contractor's work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent IS standard/ manufacturers recommendation as directed by EIC.
supply only set of gear box as per existing model.
supply only neck key, distance bush
supply only ball bearing as per existing number.
supply only fan belt as per existing number.
M&L for taking out & servicing of existing Air blower (Make -Everest,) of capacity 488 CUM/Hr from authorised service centre of Everest company with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer - in- Charge.(Note- spare parts required for replacement shall be measured and paid separetaly as supply only and cost of taking out old & fixing new if any ordered for item No 16.01 to 16.04 shall be deemed to be included in quoted rate of this item) (a) Replacement of Oil seal. (b) Replacement of locking arrangement of pully. (c) Replacement of belt. (d) Replacement of gland packing with oil and greasing.
supply only Air filter suitable for above modelstainless steel pump shaft
supply only ball bearing (Make- SKF)
supply only set of rotor with hub as per existing model.
supply only set of gear with hub as per existing model.
Taking out & rewinding the existing burnt blower motor 20 HP, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally contractors workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge super enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings,Remetalling of armature shaft and turning on lathe to give proper size for bearing fittings,Replacement of terminal plate and reinstalling at the installation and testing, commissioning etc complete. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the EIC. Old unserviceable copper retrieved will be property of contractor
Supply & fix in repair PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 6 Sqmm 3 core of with PVC conduit of size 25mm dia for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete all as specified and directed.
Supply & fix in repair 3 pole power Contactor type- MNX 9 of AC3 9Amp, 415V, 50 Hz.
Supply & fix in repair Contactor type- MNX 32 of AC3 32Amp, 415V, 50 Hz
Supply & fix in repair front mounting add on aux contact block MNX A2, 1NO+1NC, 415V, 50 Hz of Make- L&T,Havells,Siemens, C&S, Legrands,Schneider or equivelent
Supply & fix in repair control relay(Auxiliary contactors) type- MX0 22E(2NO + 2NC), 415V of Make- L&T, ABB, AE, Siemens.
Supply & fix in repair Miniature circuit breaker three pole (TP) C curve of capacity 6 Amp to 32 Amp 415V
Supply & fix in repair Miniature circuit breaker Four pole (FP) C curve of capacity 40 Amp to 63 Amp 415V
M & L for testing of treated water ( STP 1,2,3,4&5) from Regional govt approved test Lab or NABL accredited Lab approved by Garrison Engineer.The undermentioned test should be carried out by each treated water sample and their characteristics will be as under:- (i) Biochemical oxygen demand (BOD) < 10 mg/litre (ii) chemical oxygen demand (COD) < 150 mg/litre (iii) Total suspended solids (TSS) < 10 mg/litre (iv) Dissolved oxygen (DO) > 5 mg/litre (v) PH should be 6.5 to 8.5 (vi) Residual chlorine > 0.5 mg/litre or more (vii) Outlet coliform < 100 counts/100ml Note :- (i) The frequency of all test should be once in a month at equal interval. (ii) PH and residual chlorine shall be tested on daily basis in the presence of JE E/M /AGE E/M. PH meter and chlorine testing kit shall be provided by the contractor and cost of which shall be deemed to be included in above quoted rates.
M&L for rectification of leakage( Priming system) from GI 15/20 mm size bore pipe line by cutting defective GI pipe by connecting with old line with and including necessary fittings such as socket & union,Nipple,gate valve including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
S&F in repair of old U/S gland packing of valves/pump set of any sizes/capacity complete with neoprene rubber gasket ,jointing material and nuts/bolts/washer of suitable size complete all as specified and directed.
S&F in repair CI foot valve ISI marked with all fittings of size 100 mm dia
M&L for cutting of existing pipe and making arrengment for insertion of and including new ARV of following size with double chamber IS-14845 along with necessary accessories and necessory excavation and earth work as required for 100 mm bore, class PN 1.6 complete all as specified and directed.
All as per item No 29 here in before but 150 mm bore, class PN 1.6
S&F in repairs Electro magnetic Diaphragm pump Model V-12 having a capacity of 6.0 LPH at maximum injection pressure of 3.5 Kg/ cm2 complete with PP head, fittings, footvalve, Antisyphon valve and suitable to operate on 230 V/Single Phase/ 50 Hz AC supply including connecting to pipe line including testing complete as directed by EIC.
Servicing/overhauling of sludge cake Machine make Sachin Filtech pvt ltd after disconnecting from pipe by authorised manufacture company, opening and checking of various components and proper cleaning and greasing / oiling incd if any spare parts required for repair and fuctioning of machine incl replace compnay approved cloth as required each machine and PVC handle ,knob,gear etc shall be deemed to be included in quoted rate of this item and testing of machine after repair complete and making sluge brick/roll all as directed by Engr in charge.
Labour only for checking the serviceability of different spares/ component/ parts of the starter and motor pump set/ panel of any capacity at any site complete all as directed by Engr-in-charge
Supply and fix in repair of fully automatic star delta starter 10 HP (MUG-10) comprising of combo volt and ammeter single phase preventor, over load relay and timer housed in MS sheet power coated enclosure up to 10 HP Capacity complete all as specified and directed.
Supply and fix in repair of starter 5 HP (MR-G3) comprising of combo volt and ammeter, over load relay in MS sheet power coated enclosure complete all as specified and directed.
Providing daily area cleaning/sweeping of preimises of following STP including cutting out green vegetation, roots, bushes, Tree branches, picking polythene and other unwanted material from the installation area and maintaining the ground surrounding the installation and removing the same out side the defence area as directed by Engr in charge. The approx area of installation kept clean all as under. STP No 1 - 6000 Sqm
All as per item No 35.01 here in before but STP No 02 - 4900 Sqm
All as per item No 35.01 here in before but STP No 3 - 6100 Sqm
All as per item No 35.01 here in before but Raw sump Hameed Vihar 3000 Sqm
All as per item No 35.01 here in before but STP No 4 -8000Sqm
All as per item No 35.01 here in before but STP No 05 - 12000 Sqm Note :- for item no 35.01 to 35.06 (i) if contractor fail is the clean the area of installation that recovery @ 5000 per Job shall be recovered from his dues and contractors claim on this account shall not be entertained. (ii) Contractor shall provide required T&P like as (Broom, Axe,saw,bucket etc) (ii) Area will be maintained throughout the contract peroid from the date of commencement to date of completion and the payment will be made at once only.
M & L for CI Butterfly valve 100 mm dia, ISI marked,complete with all fittings/accessories, required for fixing complete all as specified and directed
M&L for water high pressure gauge including socket welded to measure pressure in the delivery pipe 0-150 Psi Kg / Cm2 Make - FE/BIG/ Guru, RAMCO
Earthing complete with glavanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanised earth lead strip 25 x 4mm size by means of nut , bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 40 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber , recessed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Pt-I 2009 print, complete all as specified & directed (Pannel Earthing) Note : Location/Site given by Engr in charge
Taking out Non clog sewage lifting pump set of Cap 5 to 12.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with pipe from the sewage collection well and removeing mud, plastic ,cloth,poleythen ,stone etc complete and testing then lowering the same after cleaning complete all as specified and directed
Taking out old unserviceable PVC bio filter media filling and M&L PVC bio filter media filling for MBBBR as per exisiting size all as directed by Engr in charge.
Material and labour for fabrication of retro-reflectroised sign board of size exceeding 0.90 Sqm as per IRC : 67 made of encapsulated lens type reflective sheeting, fixed over aluminium sheet 1.5 mm thick of required size duly written with the matter as directed in blue colour mounted on angle iron/MS pipe support complete and including grouting the sign board in Brick work, plastered and white wash on all exposed surfaces or in PCC 1:2:4 type B-2 using 40 mm graded stone aggregate complete all as directed by Engineer - in -Charge.Note – (i) Angle Iron frame work, PCC, brick work, plastering and white wash shall be measured and paid for separately under appropriate item of Schedule 'A'(ii) Retro reflective sheet and letters shall be ASTM 4956 type 3 of high intensity grade of make:- 3M Grade 3870/Kiwalite 22000/Avery Dennison Series 6200
Material and labour for mild steel frame work confirming to Fe-290 (Gde E-165) of sign boards made of M S Angle iron or MS square or round pipe of suitable thickness and size as directed duly painted with two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as directed and specified by Engineer-in-charge. Note :- The surface of angle iron coming in contact with PCC/Brick work shall be painted with two coats of bituminous paint and rate quoted for above item shall be deemed to inclusive of same.
S & F for rotational moulded polyethylene water cantainer 500 Litres capacity ( cylindrical vertical with lid ),double layer, ISI marked, fixed in position with PP head, fittings, footvalve, Antisyphon valve ,end block plate including connecting to pipe line as suitable length including testing complete as directed by EIC.
S & F for rotational moulded polyethylene water cantainer 100 Litres capacity (cylindrical vertical with lid ),double layer, ISI marked, fixed in position with PP head, fittings, footvalve, Antisyphon valve ,end block plate including connecting to pipe line as suitable length including testing complete as directed by EIC.
Providing /fabrecation in replacement of Fire point stand made out of angle iron 40x40x5mm thick and canopy roof made out of MS sheet 22 gauge thick incl provision for hanging 03 buckets fill with sand including 02 nos fire extingusher a/b/c type incl PCC foundation ,Pick axe, belcha complete sample drg approved by engr in charge before fabrication
Supplying, laying, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends with jointing materials conforming to IS 8329/2000 standard length , of k7 specification with out zinc coating laid in trenches, under floor,road etc of following dia sizes including taking out old UNSV HDPE/PVC pipe :- 150 mm Make -Jindal ltd/Electrosteel Casting Ltd/Tata Metalinks
All as per item No 47.01 here in before but 100 mm
M&L ductile iron fittings, IS-1538 marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle / radius and straight connecting pieces, but all ends flanged, size of pipe upto 150 mm bore, complete all as specified.
Excavation & earth work in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft and loose soil including trimming of sides and bottom of trenches complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers n.exc 25cm thick each in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M & L for 3- layer PP-R (Polypropylene Random Copolymer) concealed pipes SDR 7.4 PN 16 UV stabilised and antimicrobial fusion welded having thermal stability for sewage treated water supply and including all types required fittings with PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed of the following sizes :- 75 mm dia Note : Wall thickness of pipe shall be as per IS 1580 (Make- ZINDAL/ SFMC / KANHA PLASTIC PVT LTD)
All as per item No 52 here in before but 50 mm dia
All as per item No 52 here in before but 25 mm dia
All as per item No 52 here in before but 15 mm dia
Disconnecting exisitng LT over heated or burnt cable terminal / joint at panel / feeder pillar & LT cable of any size cutting out over heated/ burnt/ unserviciable portion of cable, stretching/ opening cable to suitable required length etc and fixing aluminium lugs / joint material and suitable nuts bolts & washer etc all as direeted by Engr-in-charge
Supply and fix of flex board of water installation and Machine specification board size 45CM x 60CM fix on front each and every equipment ,machiney specification given by engr in charge
Supply of UCTECH -01 ( liquid floculant ) using for the de- established colloidal particales together to form large aggregates of Sewage water ,dozing 2.5 kg/50 ppm per day (for two times ) and using at the time of peak water flow in a Settling Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -02( liquid coagulant )using for neutralizing the non - settleable particles & allow to form clumps of Sewage water ,dozing 2.5 kg/50 ppm per day (for two times ) and using at the time of peak water flow in a Settling Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -04 ( liquid disinfectant ) using for deal with bacterial problem and make fare color of water ,dozing 4 kg/80 ppm per day (for two times ) and using at the time of peak water flow in a Holding Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -03( liquid deodprizer ) using for stop biological fouling in working zone and make odorless water to provide healthy environment of Sewage water ,dozing 3 kg/60 ppm per day (for three times ) and using at the time of peak water flow in a CollectionTank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
Supply of UCTECH -07 (Nutrient chemical ) using for maintain the pH in 7-8 range to sustain quality of water as per pollution control norm of water , dozing 5 kg in a week (for two times ) and using at the time of peak water flow in a Aeration Tank complete all as specified and directed. Make : Urveeka Chemteck Pvt Ltd, or euivalent make as approved by GE
M& L preparing old steel surfaces and applying one coat of synthetic enamel paint as per existing colour such as( pipe line, filter tank and pump etc) including marking of arrow sign and name in capital letter with black synthetic enamel paint the following equpt each STP (i) Treated pump -02 Nos (ii) Filter feed Pump-02 nos (iii) Air blower -02 Nos (iv) Press filter motor -02 Nos (v) Suction/discharge line (vi) filter -02 nos
S&F 1.25 meter length of GI 20mm dia size medium grade pipe as tapping point pipe by providing 20mm dia bore gate valve with excavation of earth & refilling complete for trenches of size 2.0 x 1.0 x 1.0 meter for existing pipe line dia by proper punching for water tapping & connected with suitable saddle/clamp of size 25 x 3 mm with nut bolts & accessories complete & in PCC (1:3:6), type C1, using 20mm graded stone aggregate for stand post of size 200 x 200 x 300mm testing & commissioning on water pressure complete as directed by EIC.
S&F in replacement air pressure pipe as per existing size approx 6mtr long for connection filter press pump machine incl connection fitting , clamp ,nozel etc including testing complete as directed by EIC.
Schedule of Credit
S.R.Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .