| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹7.8 L+₹11,537.60 (1.50%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹9.2 L+₹1.5 L (19.3%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/S A Q ENTERPRISES L1 | M/S JIWANRISAM SERVICES PRIVATE LIMITED L2 | YATTOO ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and fix of bracket for street light fitting made out of 40 mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with two coat of red oxide primer and one finishing coat with aluminium paint complete all as spd and directed. | 40 | Each | 250 ₹10,000 | 200 ₹8,000 Lowest | 350 ₹14,000 |
| 2.00 | Supply, fixing and testing of 45 W LED street Light luminaire after taking down UNSV street light and deposited to MES Yard, shall be made up of Pressure Die Cast aluminum housing IP 66 efficient protection with heat resistant toughened glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed | 40 | Each | 1,950 ₹78,000 | 800 ₹32,000 Lowest | 2,300 ₹92,000 |
| 2.01Note for Item No 2 :- a). SMPS based Driver with lower THD (<10 )shall be potted anti-vibration types. b). LM-79 and LM-80 test report with 1 Lakh burning hours SMD LED life from NABL lab shall be provided. c). CRI (Colour Rendering Index) of fixture shall be > 70. d). CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. e). System Lumen Efficacy shall be > 140 Lm/W. f). 10 KV separate Surge Protection and short circuit and over voltage protection shall be provided as a part of fitting. g). 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. h). Lenses shall be Modular Type. j). PCB used shall be MC PCB type. k). The defect liability period of LED light shall be 02 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. l). CA No. shall be written on each fitting before installation. m). The name of manufacturer to be embossed on the fitting. n). The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover. | ||||||
| 3.00 | S&F three core Aluminium conductor PVC insulated cable of size 6 sqmm FR multistranded 1100 volts grade complete all as directed by Engr-in-charge. | 150 | RM | 45 ₹6,750 Lowest | 80 ₹12,000 | 48 ₹7,200 |
| 4.00 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays. | 172.8 | Cum | 90 ₹15,552 Lowest | 100 ₹17,280 | 99 ₹17,107.2 |
| 5.00 | Excavation in trenches in any type of soil n. exc. 1.5 m in width and exc. 1.5 m but n. exc. 3 m in depth and getting out all as required for laying of cables, foundation filling of poles or stays. | 1.08 | Cum | 150 ₹162 Lowest | 8,000 ₹8,640 | 150 ₹162 Lowest |
| 6.00 | Returning filling, in including spreading, leveling, watering and well ramming in layers not exc 25 cm each all as required. | 12.08 | Cum | 30 ₹362.4 Lowest | 750 ₹9,060 | 30 ₹362.4 Lowest |
| 7.00 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point. | 161.8 | Cum | 30 ₹4,854 Lowest | 100 ₹16,180 | 30 ₹4,854 Lowest |
| 8.00 | Material and Labour for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. | 1.08 | Cum | 3,000 ₹3,240 Lowest | 7,500 ₹8,100 | 3,000 ₹3,240 Lowest |
| 9.00 | Material and Labour for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. | 9.4 | Cum | 3,000 ₹28,200 | 1,500 ₹14,100 Lowest | 2,500 ₹23,500 |
Tender Value
₹9.7 L
EMD Value
₹19,300
Closing Date
4 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) CIF(K)
AGE(I) CIF (K) Shalateng C/o 56 APO
PROVN OF SECURITY/ PERIMETER LIGHTS FROM MAIN GATE TO POST NO. 06 ALONGWITH UG CABLE AND CONNECTED ACCESSORIES AT HQ 10 SECT RR AT PATTAN AND SPL REPAIR/ REPLACEMENT OF SUBMAIN WIRING AND TPN DB OF BLDG NO. P425 AND P425A AT SHARIFABAD MIL
2025_MES_717956_1
AGE (I) CIF (K) - 40/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Shalateng
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
AGE(I) CIF(K)
₹19,300
Yes
19 Sept 2025
2 Jul 2025
6 Aug 2025
2 Jul 2025
4 Aug 2025
16 Jul 2025
Amount
Supply and fix of bracket for street light fitting made out of 40 mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with two coat of red oxide primer and one finishing coat with aluminium paint complete all as spd and directed.
Supply, fixing and testing of 45 W LED street Light luminaire after taking down UNSV street light and deposited to MES Yard, shall be made up of Pressure Die Cast aluminum housing IP 66 efficient protection with heat resistant toughened glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed
Note for Item No 2 :- a). SMPS based Driver with lower THD (<10 )shall be potted anti-vibration types. b). LM-79 and LM-80 test report with 1 Lakh burning hours SMD LED life from NABL lab shall be provided. c). CRI (Colour Rendering Index) of fixture shall be > 70. d). CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. e). System Lumen Efficacy shall be > 140 Lm/W. f). 10 KV separate Surge Protection and short circuit and over voltage protection shall be provided as a part of fitting. g). 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. h). Lenses shall be Modular Type. j). PCB used shall be MC PCB type. k). The defect liability period of LED light shall be 02 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. l). CA No. shall be written on each fitting before installation. m). The name of manufacturer to be embossed on the fitting. n). The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
S&F three core Aluminium conductor PVC insulated cable of size 6 sqmm FR multistranded 1100 volts grade complete all as directed by Engr-in-charge.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays.
Excavation in trenches in any type of soil n. exc. 1.5 m in width and exc. 1.5 m but n. exc. 3 m in depth and getting out all as required for laying of cables, foundation filling of poles or stays.
Returning filling, in including spreading, leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Material and Labour for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Material and Labour for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Material and Labour for PCC 1:2:4 (nominal mix) type B-1 (using 20mm graded crushed stone aggregates) as in coping of pole complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, punning sand upto 18 cm thickness all as specified and directed.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
Supply & fix in trenches or fixed to wall/pole or passing through pipe LT XLPE cable 1100 volts grade heavy duty, armoured, extruded insulation on alumn conductor multistand of any size upto 16 Sqmm 4 core all as specified and directed.
Material and labour for GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
M&L for paint of new steel tubular pole of 9 Mtr height without removing accessories .Painting the pole with two coat of alternative green and white strips of 30cm each upto 1.5 Mtr height from coping /ground level using synthetic enamel paint. Marking of the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying two coat of alumn paint, complete all as specified and directed.
Supply and erecting of new true vertical position steel tubular swaged poles of 9 metres long, type 410 SP-31 complete with cast iron base plate,clamps, bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality green and white colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer all as specified & directed by Engineer-in-Charge. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
M&L for Earthing complete with galvanised steel earth plate electrode 600mmx600mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specified and indicated complete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected, complete all as specified & directed. Note:- 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in the unit rate quoted by the contractor. 2. Soil should be free fromstone, boulders, aggregate, gravels etc
Supply & fix junction box of size 260x160x250mm made out of 3.15 mm thick CRCA sheet powder coated front door openable with fixing arrangement by nut and bolts including 63 Amp having four No of aluminium bus bar mounted on epoxy based post insulators and drilled holes for including MCB SP 6 Amps-01 No all as required and fixed to poles using MS clamp of size 32x6mm and including nuts, bolts and washers connected electrically complete all as required at site.
S&F sheet metal enclosure factory made (double door) shutter type for DB SPN, 240 volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar complete.
S&F Distribution board iron clad TPN DB , double door with IP -43 1K -09 Protection suitable for MCB as incomer and MCB as outgoing 415 Volt 3 phase 50 C/s 6 way, complete with appropriate size copper bus bar complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-charge. Note : MCB's will be measured and paid seperately under relevent items.
S&F in replacement MCB SPN 40 to 63 Amp, type "C" 10KA, 240 Volts.
S&F MCCB 100 Amps, 36 KA, 415 Volts, 4 pole, fixed type with enclousure A FRAME, Adjustable thermal & magnetic setting ICS =100%, complete all as specified.
M&L for sub main wiring with two single core FRLS , PVC insulated , stranded , unsheathed cable copper conductor with size 10 Sqmm and drawings through & including non metallic PVC conduit concealed in wall including earth continuity conductor of size 10 Sqmm PVC unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Enginner-in-charge
Note :- An amount of Rs. Rs 8,800.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S JIWANRISAM SERVICES PRIVATE LIMITED (BID ID -3367252)
YATTOO ENTERPRISES (BID ID -3382169)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .