Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC DUE TO BEING L1 | |
| 2 | L2₹17.9 L+₹3.4 L (23.9%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹18.0 L+₹3.5 L (24.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹18.4 L+₹4.0 L (27.7%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹19.4 L+₹4.9 L (34.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹41,400
Closing Date
23 Apr 2021, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Special Repair/Replacement of LT Panel and Connected items and Certain E/M items and External Service Under GE Utilities Udhampur
2021_MES_433239_1
GE/U-100/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILTIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹41,400
Yes
20 May 2021
26 Mar 2021
26 Apr 2021
26 Mar 2021
23 Apr 2021
9 Apr 2021
Amount
Taking old unserviceable LT Panel & Supply , installation, testing and commissioning wall mounted type, weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet front openable, double door openable up to minimum 180 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 300 amps for Phases and neutral - 01 set (b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (c) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (d) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. Note :- (i) Size of LT Panel shall not be less then 3' x 2'. The panel should have hanging arrangement on the wall. The cost of complete hanging arrangement & making good the surfaces as per existing one shall deemed to be included in the unit rate quoted for this item.
Taking out the existing unserviceable LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6.3mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
Taking down U/S Garden lights and S & F Garden Light New generation, post top, energy saving, enviromental friendly, long life aesthetically, designed with symmetrical light distribution, spun aluminium landscape luminarie with high power LEDs as light source incl suitable size box and accessories complete all as specified and directed. Make : Wipro CAT No.- LP07-671-XXX-57-CL or Equivalent in Philips/ CG. Necessary Grouting/white washing/ Req. dia of pipe is deemed to be incl. by the Contractor.
Taking down U/S Gate lights and S & F Gate light design with a modern lock using new generation technology in LED to improve your outdoor areas. Shall be pressure die cast aluminium housing with specially designed optics provide uniform light distribution to redifine outdoor and enhance architectural design. Make :Wipro CAT No. LP06-351-XXX-57-XX or Equivalent Philips/ CG. Necessary Grouting/white washing/ Req. dia of pipe required for fixing of gate light is deemed to be incl. by the Contractor.
Taking down U/S LT Cables and Supplying, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed of following sizes:-
120 Sqmm 3.5 Core.
16 Sqmm 2.0 Core.
10 Sqmm 2.0 Core.
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole,stay,laying of cable and pipe etc all specified in any type of soil
Returning and filling in ,including spreading and well ramming in layers n.exc 25 cm all as specified and directed.
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point.
M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate
M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles.
S&F DWC pipe for cable Protection of Sizes 125mmx107mm along with snap fit Coupler, any additional attachments fixing all as specified and directed. Make : Rex Polyextrusion / Turipati
M&L for GI tubing, light grade, 50mm bore including necessary clamps for the protection of the cable ,laid in trenches/under road/path complete all as specified and directed.
M&L for replacement of old unserviceable cable with PVC insulated 2.5 sqmm, single core, multi stranded, copper conductor cable from junction box to street light fitting complete all as specified and directed.
Supply , installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA sheet steel mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply , installation, testing and commissioning of wall mounted support type,weather proof, panel board made out of 3.15 mm thick MS/CRCA steel sheet front side openable, double door openable , lockable / openable by keys from front side having hromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel should have clit/hanging arrangement on the wall. The panel shall be suitable to accomodate the following equiptments :-
(a) Alluminium Bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 300 amps for Phases neutral - 01 set (b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (c) MCB SPN 63 A - 10 Nos Note :- (i) Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint. (ii) Suitable glands shall be provided by manufacturer for of 400 sqmm LT Cable as incomer and outgoing 4 runs of 120 sqmm LT Cable.
M&L for factory made sheet metal LT Panel made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 75X60X30cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 600 Amps suitable for one incoming and 5 out going feeders, mounted on insulators including disconnection of cable from the burnt bus bar and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs all as per existing
S&F straight through joint kit , heat shrinkable type suitable for 35 to 95 Sqmm LT underground cable complete all as directed.
Supply and fix LED Flood Light 120 Watt with powder coated PDC Aluminium body with toughened glass visor, complete with accessories. Make : Wipro CAT No. - LF20-132-060-57-G2 , or equivalent in Philips/ CG
MOHAN LAL AND SONS
proach associates
FANGALIA TRADERS
PREM NATH KHAJURIA AND SONS
BINDRA ENGINEERS AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .