Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.6 CrAccepted-AOC | ₹10.6 Cr | 1 | Accepted-AOC being lowest tender |
| 2 | 2₹10.7 CrRejected-Finance | ₹10.7 Cr | 2 | Rejected-Finance Not Being lowest tender |
| 3 | 3₹10.8 CrRejected-Finance | ₹10.8 Cr | 3 | Rejected-Finance Not Being lowest tender |
| 4 | 4₹11.0 CrRejected-Finance | ₹11.0 Cr | 4 | Rejected-Finance Not Being lowest tender |
| 5 | 5₹11.5 CrRejected-Finance | ₹11.5 Cr | 5 | Rejected-Finance Not Being lowest tender |
Tender Value
Refer Docs
EMD Value
₹8.7 L
Closing Date
6 Mar 2021, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone
PROVN OF DEFICIENT SAILORS MD ACCN (40 DUs) AT CHANAKYA BAGH NEW DELHI UNDER GE (P) WEST DELHI CANTT-10
2020_MES_402347_2
CEDZ-26 of 2020-2021
Open Tender
Civil Works
630 days
Delhi Cantt
MES contractor enlisted in MES under class S cat a ihaving deposited Standing Security of Rs11.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
9 documents required · 9 mandatory
₹3,000
Yes
₹8.7 L
Yes
26 Mar 2021
18 Feb 2021
8 Mar 2021
18 Feb 2021
6 Mar 2021
20 Feb 2021
Amount
INTERNAL WATER SUPPLY
S & F 15 mm bore angular stop valve, half or quarter turn, cast copper alloy chromium plated all as specified and directed. Make : CERA or equivalent
S&F 15mm bore health faucets fancy type chromium plated ABS body with 1 meter SS braided conection pipe complete all as specified and directed. Make : CERA or equivalent
INTERNAL ELECTRIC SUPPLY
S&F VTPN DB's 415 Volts, IP-43, with MCCB 63 AMP, 4 pole as incommer, 4 way with 200 Amps rated copper bus bar double door type complete all as directed by Engineer-in-charge.
Supply & fix Metal and glass decorative wall lights 1X 20 Watt complete all as directed. Make : Philips cat no. 30762 Delite or equivalent in Bajaj/ Surya/ CG
S&F Decorative box type fitting with end caps pre wired for LED tube light fittings 16 watts with side holder, accessories and including connecting up with twin twisted flexible copper conductor cable of size 23/0.0076 from ceiling rose to light fittings complete including LED lamp all as specified and as directed. (Make : CG Cat No DMLN1LT8-16, LTT8-16 or equivalent in Havells/Bajaj)
All as per Srl item No 7 here-in-before but LED lube light 8W (mirror light)
M&L Lamp holder, insulated body, with back plate suitable for batten/angle fitting including 10 watt LED lamp Complete all as directed by Engineer-in-charge.
Supply & fix Round surface mounted LED flat panel fitting 1X18 watt, PDC aluminium housing and PMMA diffuser makes it a robust luminaire complete all as directed. Make : CG cat no.LCDSPLN-R-18-CDL or equivalent in Bajaj/ Surya/ Philips
All as per Srl item No 10 here-in-before but LED 1x6watt
M & L Exhaust Fan 200 mm Sweep, 240 Volt, AC 50 HZ , PVC body , heavy duty including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.(Make: Havels cat no Ventil Air-DX WHT/BLK or equivelent in CG,Bajaj)
M & L Exhaust Fan 300 mm Sweep, 240 Volt, AC 50 HZ , Metal body, heavy duty including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.
S&F Ceilling fan 1200 mm sweep, 230 volt, 50 HZ, BEE 5 star rating, BLDC with remote control complete all as specified and directed.
Supply, install, commissioning and testing busbar trunking 4 pole air isulated busbar, 3 phase 4 system (3P+N) of copper busbar 300 Amp 25X6 mm 36 KA including with all accessories like Elbow, Flange End & hanger anchor bolt with MS angle support, busbar trunking enclosed shall be made of 1.5 mm thick aluminium, GI strip 25X4 with sadldless and fitting screws etc for eathing, 12KV impluse withstand & IP 54 with piug in point and IP-55 without plug in point with IP-55 busbar trunckimg enclosure shall provide a protection not less than IP-55 for feeder element & for distribution elements IP-55 as per IEC-529 with multilayer PET Class -F insulation, temprature rise of 55 deg centigrate over an ambient of 40 deg C as per IEC/EN60439-1&2
S & F Tap off box including MCB TPN complete all connection 63 Amp capacity with MCB TPN 63 Amp, 10 KA all as directed by Engineer-in-charge.
Supply & fix AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all asspecified and directed.
S&F end feed unit with provn of and including MCCB 4 pole 320A suitable for copper bus bar trunking of 300Amp, 3 Phase and earthing strip complete all as specified and directed.
S&F MCB single pile & neutral 16 Amps 240V 10KA repturning cap, 'B' curve complete all as specified and directed
Supply and Fix HOT press moulded SMC Meter box of inside dimensions 250x150x155 mm with hinged doors and all accessories required for fixing 01 nos single phase digital electronic meter complete all as specified and directed. Make ; Sintex cat part No. :GS-MB-2525
S&F environment friendly energy saving surface mounted Bulk head fittings luminaries with 10W LED lamp complete all as specified and directed.
AREA DRAINAGE
S&F steel fibre reinforcement concrete (SFRC) cover of medium duty 70-75mm thick with perforated holes 50mm dia and set in CM 1:6 complete all as specified and directed
SEWAGE DISPOSAL
M&L for RCC Septic tank (conventional type) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 250 users complete all as directed and specified.
EXTERNAL WATER SUPPLY
Providing and laying of NP3 class R.C.C Hume pipe (IS-458) with mortise - tension jointed with cement and with RCC collar to cover and overlap the joints laid to correct levels below ground of size 300 mm dia. For underground hydrant pipe at road crossings.
M&L for extension of existing CI/MS header of 100/150/200 mm dia bore in position for insertion of one no 'Tee'/ CI special of required size and bore, connecting piece/flanged of suitable bore and connection complete for making ringmen.
Supply, installation, testing & commissioning of Horizontal mounted end suction spit casing Electric Motor driven Pump set of capacity 2280 LPM at 70 Mtrs head with synchronous speed of 1500 RPM suitable for automatic operation ,high efficiency with bronze impeller , TEFC motor , with ERW pipe Class C of 150 mm dia suction pipe , foot valve, ERW pipe Class C 150 mm dia delivery pipe up to MS Header with NRV and butterfly valve,common base frame , foundation bolts etc complete as specified along with Electrical/Control panels, power and control cabling ,cable trays, and all accesories as specified and as shown on drawings and complying to specifications, drawings, relevant standards and authority regulations..
Supply , laying jointing testing ductile iron pipe with spigot socketed ends class K-9 conforming to IS 8329 with inside cement mortar lining laid in trenches of 100mm bore size all as specified and directed by Engineer-in-charge.
Supply , laying jointing testing ductile iron pipe with spigot socketed ends class K-9 conforming to IS 8329 with inside cement mortar lining laid in trenches of 80mm bore size all as specified and directed by Engineer-in-charge.
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning of Compact Sub Station of 11 KV/433 Volts with 315 kVA Cast Resin Transformer, consisting of HT panel, LT panel inside GI sheet steel enclosure with all interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications detailed below :-
Outdoor Enclosure Outdoor type enclosure having modular construction of 1.5/2mmGalvanised Sheet Steel. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23D degree of protection for Transformer compartment. The enclosure exterior shall be painted with polyurathene paint ( colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement The Compartment illumination lamp with door operated switch shall be provided for each compartment. Interconnection Between HT switchgear & Transformer using XLPE Single core cable & Interconnection between Transformer & LT switchgear using Busbars. Internal earthing connections. All metallic components shall be earthed to a common earthing point. Dimensions: 2330 X 3230 X 2415 mm (W X L X H) or as per the final decision at Site for components to be included in enclosure.
HT Panel:- 11kV, 630A, 25KA/3 sec HT Switchgear consisting of 1 no. fixed type Vacuum Circuit Breaker module for transformer protection. All the live parts, VCB modules , isolators, earth switches must be sealed within robotically welded 3 mm thick single stainless steel tank filled with SF6 gas as insulation having IP67 degree of protection. Each module of the panel should have hinged arc proof cable doors with self interlocking mechanism to the corresponding earth switch and self motorised charged with DC backup and manually operated, all cable terminations shall be from the front, ringcore CTs for protection purposes with self powered microprocessor based numerical 3 O/C & 1 E/F relay, arrangment for connecting incoming cable & outgoing to primary of transformer. Switchgear shall be complete with all connection, Copper bus-bars, cable supports, manometer, voltage indications, mechanical indications for breaker as per IS:13118, 5227, 5463. IEC:265,129, 298, 694, 529.including battery bank with 12 Volts battery mounted outside of VCB and electrical connections.
Transformer 315 KVA , 11KV / 433V ,DYn11, oil type AN cooled transformer alongwith with Off Circuit tap links of rating with three steps - 5% to +7.5% in steps of 2.5 % each.
Interconnection & Earthing Internal factory connections Between HT switchgear & Transformer shall be done using 1Cx3x50Sq.mm XLPE single core cable & Interconnection between Transformer & LT switchgear using Busbars.
LT PANEL OUTGOING 433V LT Indoor panel with Aluminium Busbars , Fabrication using 1.5/2 MM CRCA sheet steel , Ingress protection IP4X , solidally earthed at substation complete with internal wiring, indication lamps etc consisting offollowing switchgear :-
1 no - 630 Amp,433 V, 4P, 50 Hz, 50KA, ACB with microprocessor Release Fix type as Incomer Cum Outgoing.
2 Nos MCCB 400 Amps 4 pole 50 KA for outgoing supply to building panel (01 No Spare)
1 Nos MCCB 125 Amps 4 pole 25 KA for outgoing supply to AMF panel
LT Switchgear should be suitable for termination of 2 run X 3 ½ C X 400 Sq.mm aluminum armored Cable.Qty: 2 sets ( one for incomer from Transformer and other for Alternate
All including excavation, earth work and PCC foundation as required as per manufecturer's recommendations.
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) indoor/outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 800 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 cass protection and made of 3.15mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including probision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following and all internal connections with bus bar trunking :-
(a) INCOMING :
(i) MCCB 4 pole 400 Amps 50 KA rating - 01 No
(iv) CTs with ratio 800/5 class ISI marked - 01 Set of three
(v) LED type indicating lamp (R.Y.B) - 01 Set of three
(b) OUTGOING
(i) MCCB 4 pole 415 volts 300 Amps rating and repturing cap 35 KA - 02 Nos
Supply, installation, testing and commissioning of factory made & tested (incl CPRI test cerfitied) Automatic Power Factor Correction (APFC) (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 ph 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 600 Amps rating installed on pocelian insulator. The panel shall be dust and virmin proof IP65 class of protection and made of 3.15mm CRCA sheet MS and 40x40x6 mm thick angle iron frame work powder coated finish over one coat of red oxide primer outside and two coat of red oxide primer inside, front opening type with provision of cable entry with double door shutter and locking arrangement, internal wiring with PVC insluated solid copper conductor FRLS cable of adequate size not less than 4.0 sqmm. The panel should be suitable for housing in and including the following complete all as specified and directed :-
(i) MCCB 4 pole 400 Amps of rupturing cap 50KA-01 No as incomer.
(iv) CTs with ratio 400/5 class ISI marked - 01 Set of three
(v) LED type indicating lamp (R.Y.B) - 01 Set of three
(vi) MD-XL Double metalized paper (Extra low loss) capacitor for 3 Phase 50 Hz system for permisable non linear load 20% of capacity 50 KVAR-01 No, 25 KVAR-03 Nos, 12.5 KVAR-02 Nos (Total cap 150 KVAR)
M&L for chemical earthing complete with earth electrode made of high tensile low steel circular rods, molecularly bonded with copper on outer surface to meet the relavent indian standards and shall be of the approved make & design. the earth electrode shall confirm IS and of minimum 17 mm dia and minimum 2 mtr long & thickness of copper bonding minimum 250 microns. hole of 100 mm to 120 mm dia shall be augured to a depth of about 2.5 mtr. earth electrode shall be placed into the hole. by penetrating it into the soil gently diving on the top of the rod, so that min. 150 mm of the electrode shall be ibserted in the natural soil/ present soil. earth enchancement material (minimum approx. 20 Kg) shall be filled in to the augured hole in slurry from and allowed to set. after the material get set, the diameter of composite structure (earth electrode + earth enchancement material) shall be of minimum 100 mm dia covering entirelength of the hole. remaining portion of the hole shall be covered by backfill soil/ material. A copper strip of 150mmx25mmx6mm shall be exothermically welded to main earth electrode for taking the connection to the main equi-potential earth bus bar /ICT centre. multi strand single core PVC insulated 10 Sqmm copper cable connecting to main earth electrode. earth enhancement material consist of Graphite and portland cement. Bentonite content shall be negligible. high conductivity & humidity retention capability, non corrosive in nature having low water soiubility but highly hygroscopic. Inspection chamber size of 300x300x300 mm (inside dimension) box (concret / Iron) with smooth finish shall be provided on the top of the pit. A concrete /Iron lid painted black with pulling hooks, shall be povided to cover the earth pit. copper lugs with stainless steel nut and bolts complete all as directed.
S&F of street light pole box of size 200mm x 160mm x 98mm, made of high quality thermosetting plastic polyesterene, dust and jet water proof, chemical/acid corrosion resistantr impact and shock proof IP 65 with internally imbedded gasket (PUR) including 1 No SP MCB 6 Amps alongwith door arrangement and pre-moulded knock out all the sides including back of the base. The box must be fitted with 10 Sqmm stud type terminal 04 Nos including Elmex stud type TB 04 Nos (Make Hensal or equivalent)
Supply, installation, testing and commissioning of indoor type cubicle single panel, 400A ,11 kV, 3 Phase, 50 Hz., metal clad, dead front, floor mounted, vertical isolation, Horizontal drawout, 250 MVA rupturing capacity Vacuum Circuit Breaker Incoming & Outgoings as per the detailed specifications given in tender document including all connections, etc., with POWER PACK door interlocking panel and should be expendable type complete in all respect as per technical specifications and as required and having following:
1 No. 400A, 11kV, 3 Phase, 50Hz., metal clad, dead front, 250 MVA rupturing capacity, Fully Drawout type, Vacuum Circuit Breaker (VCB)
1 set of 11kV/110V, 150VA Potential Transformers with protection MCB
1 Set of Phase indicating lamps with protection MCB
1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED,TRIP CIRCUIT
1 set of 100/5-5A Current Transformer for metering and protection 15 VA burden with class 0.5-1.0 accuracy
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
S & F Aviation obstruction light (Twin) aviation Yellow painted die cast Al alloy housing, red coloured polycarbonate dome and accessories suitable for LED 2x6 watt complete all as specified and directed.
FIRE FIGHTING AND ALARM SYSTEM (E/M)
Supplying, erecting &commissioning following Fire cabinet:- a)Supplying and fixing single headed internal hydrant valve with instantaneous gun metal /SS coupling of 63 mm dia with cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain as required.
b)Providing and installation of 63 mm dia,2 X15 Mtr long rubber lined woven jacketed hose pipe, type- A (Reinforced rubber lined) of IS636-1988 complete with necessary instantaneous spring lock type coupling at the ends to match with landing valve / hose pipe / branch pipe with gunmetal/SS male & female couplings (IS:903:1993)(Make : PADMINI/OMEX/TORRENT)
c)1no gun metal branch pipe with nozzle (63mmx20mm) with Gun metal gate/ ball valve (20mm)
d) Two keys in recess type compartment for break glass
e) Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post Office Red drum and brackets, Conforming to IS 884 with upto date amendments, complete with the following as required. (a) 30 m. long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) Drum and brackets for fixing the equipments on wall, Connections from riser with 25 mm dia stop valve & M.S. Pipe .
f)The double door with frame of size 1000mm X 1650mm made of 16 gauge ,4mm inside glass painted red.
Air Vessel 3m³ capacity having 450mm O.D x 1.5m cylindrical height, made out of 12mm thick Dishend and 10mm thick Shell of I.S:2062 Gr-A/B having dish end welded with shell manufacturing as per Design code I.S:2825, Class II suitable for working pressure 9 Kg/cm², Hydrotested at 21Kg/cm², Joint efficiency 0.85, Radiography longitudinal seam 100%, Circumferential seam 10% spot with all necessary valves & fittings.
Providing ,fixing,testing and commissioning of 12 Zone window type main fire alarm panel for Manual call box, power card rectifier relay for actuation of hooter on respective floor, adjustable timmer, sealed maint free battery 15 AH 24 Volts capable of running minimum of 12 hours with battery charger. LED indicators for fire signal of individual unit. Each fllor shall have a separate relay for actuation of sounder. through tone generator and PA panel. Panel shall also be provided with key operated auto dialer and connection to P&T lines with 4 auto programmed into the panel. complete in all respect as directed.
Supplying, installing and commissioning of fire brigade inlet connection conforming to IS 5290 comprising of 4nos. 63mm dia instantaneous couplings complete with CI non-return valve, CI butterfly valve, connected to 100mm dia. wet riser pipe.
Supplying, installing ,testing and commissioning of MS air cushion tank on top of each riser fabricated from 8mm thick MS plate, 250 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia. valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968.- Terrace floor
Supply and fix Addressable manual call point resettable type
Supply and fix 6 Watt wall mount CD Speaker in accoustically treated box
M&L for wiring with earth wire on surface/recessed with 2x1.5 Sqmm and 1x1.5 Sqmm FRLS copper conductor wire passing through and including suitable size MS conduit. Complete with MS saddle if surface wiring all as directed.
Providing and fixing set of wall mounted signages of Zinc Sulphide Photo luminescent coating on 6mm thick acrylic sheet each of size 15cm x 30cm and consisting of signage on half side and arrow on other half. Each set of signages made separately on each sheet of size 15x30 cm each comprise of "EXIT,STAIRCASE,MANUAL CALL BOX, HYDRANT, EXTINGUISHER
S&F 63mm dia 15 mtr long rubber lined woven jacketed hose pipe type 'A' (RRL) with necessary instantaneous spring long type coupling at the end to match with the landing valve/hose pipe /branch pipe with GM /SS male female coupling complete all as specified and directed.
S&F Hydrant valve double headed comprising of 63mm dia instantaneous coupling complete all as specified and directed.
S&F GM branch pipe 63mm instantaneous inlet male threaded outlet 20mm/15mm bore nozzle long complete all as specified and directed.
S&F hose box made of 18 guage MS sheet 800x600x250mm with double door with 4mm thick glass and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed.
S&F yard hydrant post/stand post 100 mm dia GI/MS both franged type 1.5 mtr height with one No suitable dia butterfly valve complete all as specified and directed.
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos. Make:- Havells (cat part no. LHEBMFP6IZ2W012) or equivalent model in CG/Philips.
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per as Per IS(minimum efficiency class equivalent to IE 2 and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display and car position indicator in car all fixture in SS face plate (both insided/out-side).All Buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) IInbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside the lift car to alert the persons trapped inside they are being rescued.
(j) Provision of governor grooved belt and along with belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator to nearest landing of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door Sensor not less than 74 beam, 2D infra red full length.
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n)Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p)A three Pin plug socket with switch for hand lamp shall be fitted top of the lift car for use by person working there on.
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos. Make:- Havells (cat part no. LHEBMFP6IZ2W012) or equivalent model in CG/Philips.
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per as Per IS(minimum efficiency class equivalent to IE 2 and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display and car position indicator in car all fixture in SS face plate (both insided/out-side).All Buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) IInbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside the lift car to alert the persons trapped inside they are being rescued.
(j) Provision of governor grooved belt and along with belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator to nearest landing of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door Sensor not less than 74 beam, 2D infra red full length.
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n)Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p)A three Pin plug socket with switch for hand lamp shall be fitted top of the lift car for use by person working there on.
DG SET
Supply, installing, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 40 KVA (32 KW),or nearest higher rating 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz to operate at a powers factor of 0.8. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on AVM pads (As per respective Mnufacturer Design ) on a common base frame all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following: -
(a) ENGINE (PRIME MOVER): Diesel engine 1500 RPM of suitable HP as recommended by manufacturer but not less than 52 BHP (at NTP) water cooled, Turbocharged aircooled, 1 x90 AH 12 volts electric battery start, confirming to BS 5514,BS 649 and IS 10000 complete with fly wheel and all standard fittings/ fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauges, water temp gauge, and frequency meter (digital type) (including safety shutdown contents) and also including self starter, dynamo, fuel tank etc.
(b) ALTERNATOR : AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613 / 5000, 3 phase , 415 volts, 4 wire rated line current 45 amps for output PF 0.8, 1500 RPM, insulation class ‘H’ Temprature Reise H @ 40 Deg C; Enclosure IP 23 confirming to IS-4722 / BS-2613 complete with AVR with + 1 % voltage regulation, directly coupled to and match the above engine.
(c) Anti-vibration pads for mounting engine – alternator assembly on the base frame/ plate.
(d) BASE FRAME:One no. MS Fabricated adequately machine Channel Common Base Frame with lifting facility,pre-drilled foundation holes suitable for permanent installation on concrete foundation for direct grouting or on anti-vibration mountings which will be suitable to receive the offered engine and alternator duly coupled through a flexible coupling. A suitable coupling guard shall also be provided
(e) Silencer: Critical Grade and exhaust gas piping system of suitable dia MS pipe of 'B' class of required legth as per CPCB norms with necessary bends, supports and clamps anti vibration mounting inulated with rockwool 50 mm thick with wire mesh and aluminium clading complete all as specified
(f) Fuel tank of 100 Litres/specified by the manufacturer, made of 14 SWG CRCA MS sheet, duly powder coated and provided with float, gauge and fuel float switch.
AMF Panel:-
Fabricating, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 40 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including for following:
MCCB 63 Amps. 4 Pole
(a) 2 Nos over voltage relay, 2 Nos reverse power relay and 2 Nos under voltage relay.
(b)3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
(c) Energy analyzer unit to indicate current voltage frequency power factor and KWH
(d) Indicating lamps for load on mains and load on set
(e)Fuse for instruments
(g) Main supply failure monitor
(h) Supply failure timer
(i)Restoration timer
(j)Control unit with three impulse automatic engine start/ stop and failure to starty lockout
(l) Impulse counter with locking and reset facility
(i) Audio/ Video annunciation for
(ii) High water temperature
(iii) Low lubricating oil pressure
(iv) Engine over speed
(v) Engine fails to start
(vI) Full load/ maximum load warming
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip.
ARBORICULTURE
Supply & planting following trees/plants/shrubs/hedge: in location as shown on drawing and as directed by Engineer-in-charge including preparing composed pit of required size (1.20x1.20x1.20 meter or 0.45x0.45x0.45 meter) as per requirement size in any type of soil applying anti temite treatment, refilling of the pit with compost (menure, sand & sweet earth mixed in (1:1:4) breking clods, ramming & flooding with water filling fine dressing & removal of rubbish, unserviceable material & surplus earth complete all as specified & directed by Engr-in charge. Note : - (i) ATT shall be in form of 200 gms neem cale mixed with each cum of compost followed by ATT chemical (Dursban) applied at 50 ml per liter in 1st watering 30 ltr per pit. Rates for following item include supply & application of manure /sweet earth, ATT chemical, sand, fertilisers and transportation complete. Height of plant is to be measured from ground level.
1.1 Trees
(a) Alstonia Scholaries (i) spacing @10-15' (ii) Ht 5'-6' girth : 8 to 12 cm, Pit size (1.20x1.20 m)
(b) Jacaranda Mimosifolia (i) Spacing @ 8-10' (ii) Ht 5'-6' girth : 2 to 4 cm, Pit size (0.45x0.45)
(c) Gold Mohar (i)Spacing @ 10-15 (ii) Ht 5'-6' girth : 8 to 12 cm, Pit size (0.45x0.45m)
(d) Plumeria Alba (i) Spacing @ 10-15' (ii) Ht 6'-7' girth : 8 to 12 cm, Pit size (1.20x1.20 m)
(e) China Orange (i) Spacing @ 10-15 (ii) Ht 3'-4' girth : 8 to 12 cm, Pit size (1.20x1.20 m)
1.2 Shrubs
(a) Budha Velly Bamboo
(b) Ficus panda
(c) Galphimia glauca
(d) Plumbego
(e) Ficus Rajnold
(f) Largestonia Indica
(g) Bauhinia Alba
(h) Tabormontana Verigata
(j) Acleefa
(k) Eranthimum
(l) Galphimia glauca
(m) Calliandra
(n) Tecoma Gaun Chauri with height 3'-5'
(a) Cycus Palm with Height 2'-3'
(b) Cycus Circinalis height 3'-4'
(c) Lonila with height 2'-3'
(d) Phoenix Palm with height 3'-4'
1.4 Ground Covers (Hedge)
(a) Golden duranta with height 9"
(b) Clerodendron Inermi with height 6"
(c) Iresine with height 9"
(d) Opiopoghum with height 9"
Maintenance of all plants, shrubs, Hedges, grass etc for a period of 06 month after date of completion by employing 3 (three) skilled Gardener per day to ensure healing up keep,of watering plant, pour manure, carryout periodic tilling and use pesticides, cutting grass and removing unwanted grass & plants at work site. Note :- (i) During the period any plant, shrubs, grass etc is found dead, not true to name or size as specified or not in satisfactory growth plat of approved size & shape shall be replaced by the contractor. (ii) If contractor fail to comply above points the work will be carried out through other agency and amount will be recovered from the earnest money and 10% of reserved money (10% of contract amount will be kept for guarantee period. (iii) Supply & application of manure, sweet earth sand, ATT Chemical & pesticides etc, Fertilisers etc are included in the quoted unit rate during Maintence period.
HOT WATER SUPPLY
Supply and fix water heater storage type, electric, capacity 25 Ltrs, BEE 5 star rated.complete including grouting of nuts bolts etc and PVC connection for inlet and outlet supply complete all as specified.
Description of Work / Item(s)
Amount
Total amount of Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Road, Path, and Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (Compound Wall, Fencing and Gate) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (Rain Water Harvesting System) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of Sch 'A' Section X (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of Sch 'A' Section XI (Fire Fighting including Fire Alarm System (E/M) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (Lightening Protection) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Total amount of Sch 'A' Section XIII (Demolition and Dismantling) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIII)
Total amount of Sch 'A' Section XIV (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIV)
mahinder pal and co
Global Enterprises
M P TYAGI ENGINEERS AND CONTRACTORS
AMIT ASSOCIATES
GANGA INFRABUILD PVT LTD
M/S ALPHA CONSTRUCTIONS
City Promoter and Buildwell Pvt. Ltd.
mahinder pal and co
AMIT ASSOCIATES
City Promoter and Buildwell Pvt. Ltd.
M/S ALPHA CONSTRUCTIONS
GANGA INFRABUILD PVT LTD
GOYALA INFRA PROJECTS PVT LTD.
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid