Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-Finance 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | L1 | Accepted-Finance Admitted | |
| 2 | L2₹7.9 L+₹15,378.40 (2.00%)Accepted-Finance 3 6 753 A GENERAL ELECTRICALS REFRIGERATION 3 6 753 A HIMAYATHNAGAR ST NO 14 40 HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | L2 | Accepted-Finance Admitted | |
| 3 | L3₹8.1 L+₹40,478.40 (5.25%)Accepted-Finance 1 1 315 10 BAPU NAGAR CHIKKADPALLY HYDERABAD 500 020 | HYDERABAD | HYDERABAD | TELANGANA | 500020 | L3 | Accepted-Finance Admitted | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically not qualified | |
| 5 | Rejected-Technical 6 SECOND FLOOR MAHATHMA GANDHI STREET THORAIPAKKAM CHENNAI KANCHIPURAM TAMIL NADU 600097 | CHENNAI | TAMIL NADU | 600097 | - | Rejected-Technical Technically not qualified |
| Sl No | Description | Qty | Unit | General Electricals and Refrigeration L2 | ETA Engineering Pvt Ltd L1 | SHAKTI POWER LINES L3 |
|---|---|---|---|---|---|---|
| 1.001) The estimated amount is inclusive of GST. 2) The Bidder should quote basic rates exclusive of GST and quote GST percentage separately. GST should be revised from time to time. | ||||||
| 2.00 | Supply, installation, testing and commissioning of 5 star rating 1.5 TR Inverter Split Air Conditioner with Inverter rotary compressor, copper condenser & filled with Eco Green Refrigerant / Non CFC and other accessories complete including dismantling of old Split AC unit and core cutting etc. as required (Item inclusive of copper piping from outdoor unit to indoor unit approx 3m). | 20 | Each | 36,000 ₹7,20,000 | 35,358 ₹7,07,160 Lowest | 36,500 ₹7,30,000 |
| 3.00 | Supplyng & fixing of 4 KVA Voltage Stabilizr suitable for 1.5 TR Split Air Conditioner including inter connections, testing, and commissioning etc. as required. | 20 | Each | 2,500 ₹50,000 | 2,258 ₹45,160 Lowest | 2,711 ₹54,220 |
| 4.00 | Providing & fixing of MS readymade powder coated angle iron stand for mounting AC outdoor unit etc., as required. | 10 | Each | 800 ₹8,000 | 553 ₹5,530 Lowest | 600 ₹6,000 |
| 5.00 | Supply & laying of 3 core 2.5 sq.mm copper conductor PVC insulated wire i/c inter connections etc as required. | 25 | Rmt | 150 ₹3,750 | 172 ₹4,300 | 84 ₹2,100 Lowest |
| 6.00 | Supply & laying the following size of Rigid PVC pipe for drainage on surface i/c clamping etc as required ¾” PVC pipe. | 25 | Rmt | 200 ₹5,000 | 84 ₹2,100 | 25 ₹625 Lowest |
| 7.00 | Providing and fixing extra copper piping with insulation beyond initial 3 Mtr length for 1.5 Ton Split AC unit ¼ inch & 5/8 inch | 20 | Rmt | 1,100 ₹22,000 | 879 ₹17,580 Lowest | 1,101 ₹22,020 |
| 8.00 | Supplying & fixing 20 amps, 240 volts, SPN Industrial type, socket outlet, with 2 pold and earth, metal enclosed plug top along with 20 amps “C” Curve, SP, MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. | 15 | Each | 1,800 ₹27,000 | 1,270 ₹19,050 | 1,059 ₹15,885 Lowest |
| 9.00 | Less: Credit for dismantled old split AC unit (Indoor & Outdoor) under buy back. | 20 | Each | 2,500 ₹-50,000 | 1,525.42 ₹-30,508.4 | 1,000 ₹-20,000 Lowest |
Tender Value
₹10.1 L
EMD Value
₹20,153
Closing Date
24 Sept 2025, 3:00 pmClosed
Executive Engineer A/C
University Works Department, Admin Bldg., UoH, Gachibowli, Hyd 500 046
Supply, Installation, Testing and Commissioning of 1.5 ton capacity split ac units in various blocks at Lake View Guest House Building in University of Hyderabad campus
2025_UoH_876704_1
UH/ENGG/UWD/2025-26/
Open Tender
Electrical Works
Item Rate
30 days
University of Hyderabad, Hyderabad
Please refer as per tender document
7 documents required · 7 mandatory
₹0
₹20,153
Yes
13 Oct 2025
10 Sept 2025
25 Sept 2025
10 Sept 2025
24 Sept 2025
10 Sept 2025
10 Sept 2025 - 24 Sept 2025
Amount
1) The estimated amount is inclusive of GST. 2) The Bidder should quote basic rates exclusive of GST and quote GST percentage separately. GST should be revised from time to time.
Supply, installation, testing and commissioning of 5 star rating 1.5 TR Inverter Split Air Conditioner with Inverter rotary compressor, copper condenser & filled with Eco Green Refrigerant / Non CFC and other accessories complete including dismantling of old Split AC unit and core cutting etc. as required (Item inclusive of copper piping from outdoor unit to indoor unit approx 3m).
Supplyng & fixing of 4 KVA Voltage Stabilizr suitable for 1.5 TR Split Air Conditioner including inter connections, testing, and commissioning etc. as required.
Providing & fixing of MS readymade powder coated angle iron stand for mounting AC outdoor unit etc., as required.
Supply & laying of 3 core 2.5 sq.mm copper conductor PVC insulated wire i/c inter connections etc as required.
Supply & laying the following size of Rigid PVC pipe for drainage on surface i/c clamping etc as required ¾” PVC pipe.
Providing and fixing extra copper piping with insulation beyond initial 3 Mtr length for 1.5 Ton Split AC unit ¼ inch & 5/8 inch
Supplying & fixing 20 amps, 240 volts, SPN Industrial type, socket outlet, with 2 pold and earth, metal enclosed plug top along with 20 amps “C” Curve, SP, MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Less: Credit for dismantled old split AC unit (Indoor & Outdoor) under buy back.
General Electricals and Refrigeration (BID ID -3284587)
SHAKTI POWER LINES (BID ID -3287939)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .